Loading...
RC-0737-2020 t f Office Use Only PRINCIPLE STRUCTURE PERMIT Permit#: �-O9'� r 2020 APPLICATION Permit Fee:$ IDS 20 $'n81.20 Town of Queensbury *Rec. Fee:$ 1109 742 Bay Road,Queensbury, NV 12804 Invoice#: P: 518-761-8256 www .queensburynet 24t 24f �\o P1 Project Location: 15 Luzerne Road — Building # Tax Map #: 309.10-1-97 Subdivision Name: TOWN BD.RESOLUTION 86-2013:$850 recreation fee for new dwelling units: single family, duplexes/two-family, multiplefamily, apartments,condominiums, townhouses,and/or manufactured &modular homes,but not mobile homes. This is in addition to the permit fee(s). CONTACT INFORMATION: • Applicant: - - Name(s): Hayes & Hayes LLC Mailing Address, C/S/Z: 297 Saratoga Road, South Glens Falls NY 12803 f r 1:r' Cell Ph.: ( ) Land Line: 518-792-9142 Email:jamiehayes4@outlook.com k. • • • Primary Owner(s): ! • Name(s): Hayes & Hayes, LLC o Mailing Address, C/S/Z: 297 Saratoga Road, South Glens Falls NY 12803 Cell Ph.: ( ) Land Line: 518-792-9142 • Email:jamiehayes4@outlook.com • Contractor(s): Name(s): Hayes & Hayes, LLC Mailing Address,,C/S/Z: 297 Saratoga Road, South Glens Falls NY 12803 Cell Ph.: ( ) Land Line: 518-792-9142 Email:jamiehayes4@outlook.com • Architect(s)/Enoineer(s): Name(s): Ethan P. Hail - Rucinski Hall Architecture Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Ph.: 518-260-2888 Land Line: 518-741-0268 Email: ephall@nycap.rr.com Contact Person for Building & Code Compliance: Ethan P. Hall Cell#.: 518-260-2888 Land Line: 518-741-0268 Email:ephall@nycap.rr.com Principle Structure Application Revised January 2019 PROJECT INFORMATION: TYPE: ❑ Commercial ® Residential WORK CLASS: ❑ Single-family 0 Two-family ❑ Multi-family (#of units: 0 Townhouse ❑ Business Office ❑ Retail ❑ Hotel/Motel ❑ Industrial/Warehouse ❑ Garage (#of cars_J El Other(describe STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 15T floor: 1,241 VT floor: 2nd floor: 1,265 2nd floor: 3rd floor: Total square feet: Basement(habitable space): 1,098 Total square feet: 3,604 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $_$500,000 2. Proposed use of the building:Two family Residence 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat: ®Gas ❑Oil ElPropane ElSolar ElOther: (Fireplaces need a separate Fuel Burning Appliances&Chimney Application,one per appliance) 5. Are there any structures not shown on the plot plan? OYES ®NO Explain: 6. Are there any easements on the property? DYES 15 NO 7. SITE INFORMATION: a.What is the dimensions or acreage of the parcel? 3.47 acres b. Is this a corner lot? DYES El NO c. Will the grade be changed as a result of the construction? ®YES ❑NO d. What is the water source? ®PUBLIC ❑PRIVATE DWELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? Sewer Principle Structure Application Revised January 2019 DECLARATION: I. I acknowledge that no construction shall commence prior to issuance of a valid building permit and work will be completed within a 12 month period. 2. If the work is not completed by the 1year expiration date the permit may be renewed, subject to fees and department approva I. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I understand that I/we are required to provide an as-bui It survey by a licensed land surveyor of all newly constructed facilities priorto issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ethan P. Hall —Architect\Agent for the Applicant SIGNATURE: Ciao A 7Vall DATE: 27 Nov 2020 Principle Structure Application Revised January 2019 mmmmmmim anrvmoi mim U IIII� i P4l S I' fi, ( Ti 0 I111 518.832.9213 1 ryan@clearvuinspections.com 1 18 Blackberry Lane,Queensbury,NY 12804 Hayes& Hayes LLC 297 Saratoga Road South Glens Falls, NY 12803 jdogbrown19777@yahoo.com ClearVU Inspections, performed a one-point airtightness, blower door test on the single family dwelling located at 24AJames Place,Queensbury, NY,to determine the air changes per hour on Wednesday, November 13,2024.The dwelling was depressurized and the testing procedure performed as per IECC- R402.4.1.2. Test conditions were as follows: Fan location - Back Door 350'above sea level 655 CFM50 42°F outside air temperature 60°F inside air temperature Pre-Test Baseline Building Pressure -3.7 Pa -50.0 Pa testing pressure TEC DG-1000& Model 3 Fan Altitude Correction Factor=(1+(.000006 x altitude))x CFM50 = n/a Results:( 655 CFM50 x 0.981 x 60 Minutes)/ 14,256 cubic feet) _ 2.704 ACH50 IECC-R402.4.1.2-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ASTM E 779 or ASTM E 1827 and reported at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed atthe time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Ryan Wild ClearVU Inspections BPI IDL Certification - 5063518 Asbestos Sampling & Handling License- 879660/282890 NYS Home Inspector License- 16000085839 mmmmmmim anrvmoi mim U IIII� i P4l S I' fi, ( Ti 0 I111 518.832.9213 1 ryan@clearvuinspections.com 1 18 Blackberry Lane,Queensbury,NY 12804 Hayes& Hayes LLC 297 Saratoga Road South Glens Falls, NY 12803 jdogbrown19777@yahoo.com ClearVU Inspections, performed a one-point airtightness, blower door test on the single family dwelling located at 24B James Place,Queensbury, NY,to determine the air changes per hour on Wednesday, November 13,2024.The dwelling was depressurized and the testing procedure performed as per IECC- R402.4.1.2. Test conditions were as follows: Fan location - Back Door 350'above sea level 641 CFM50 42°F outside air temperature 60°F inside air temperature Pre-Test Baseline Building Pressure -3.7 Pa -50.0 Pa testing pressure TEC DG-1000& Model 3 Fan Altitude Correction Factor=(1+(.000006 x altitude))x CFM50 = n/a Results:( 641 CFM50 x 0.981 x 60 Minutes)/ 14,256 cubic feet) _ 2.646 ACH50 IECC-R402.4.1.2-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ASTM E 779 or ASTM E 1827 and reported at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed atthe time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Ryan Wild ClearVU Inspections BPI IDL Certification - 5063518 Asbestos Sampling & Handling License- 879660/282890 NYS Home Inspector License- 16000085839 L U Z E R N E R D 11A ST JAMES PL 28B ST JAMES PL 31B ST JAMES PL 20A ST JAMES PL 27A ST JAMES PL 32A ST JAMES PL 12B ST JAMES PL 24A ST JAMES PL 19A ST JAMES PL 35B ST JAMES PL 16A ST JAMES PL 15A ST JAMES PL 28A ST JAMES PL 20B ST JAMES PL 23B ST JAMES PL 12A ST JAMES PL 24B ST JAMES PL 11B ST JAMES PL 19B ST JAMES PL 31A ST JAMES PL 16B ST JAMES PL 15B ST JAMES PL 27B ST JAMES PL 32B ST JAMES PL 23A ST JAMES PL 35A ST JAMES PL St. James PlaceAddress Map µ 0 50 100 150Feet Map Produced by TOQGIS: 12/2020DRAFT Service Layer Cred its: NYS ITS GIS ProgramOffice IRF XfAr,XTETIC GRASSED WEIRS iPOND 4 WEIR ELEV-= 359.5 LANDS OF POND 3 WEIR ELEV. 360.75 THOMAS SPRING 4'0 x 4' DEEP DRYWELL TALL IP AS PER DETAIL ON S— TOP OF GRATE = 358.5 2' W X 2' D Ah STONE DIAPHRAG AS PER DETAIL ON SP-5 4'0 x 4' DEEP DRYWELL /AS PER DETAIL ON S-3 TOP OF GRATE = 360.5 F u < < z < 5 0 c § � 0 < 6 TP --j #1 rV2 x 12 67 10 Z 11S19 To r" umm:11413141mem" lKelmus WcAzr-.,§lf. LANDS OF FIRE FIGHTERS OF WEST GLENS FALLS ASSOCIATION CO IN CRUSHED STONE ASPHALT 1 TION = 359.5 LANDS OF (s) I M=3G.3-14 GRASSED WEIR EDWARD MURRAY GV' WEIR ELEV.= 364.75 p I I ;4 �4 CIO, LANDS OF WEST GLENS FALLS VOLUNTEER FIRE COMPANY NO. 1 "0 py FILE CO Nov 020 309.10-1-97 RC-0737-2020 Hayes & Hayes LLC 15 Luzerne Rd, Bldg- 4 3604 s-f. 2-family dwelling A 0 2 fj G R A PH IC SCAI„ 1 4V—O'A No DESCRIPTION DAfffaC REVISIONS Lu c c" cu DM Z L e "q::) L) < -j v, 0 0 aF - E u F- 0 (-! Ro 0 00 co tr C) ct co t, z (D (D �;- P c ;2 (1) < Lu to a) x LL- 0 0 N-3 E ARK IS TO BE AS S[iOWN & NOTED AND IN ACCOR)ANCE \NJ TH MANUFA�TURER'S R COMMENDATIONS, "RADE ASSOCIATION P UB0SHED RECOMMENDAT11ONS,, AND GENERALLY ACCEPTED &�OCAL CONSTRUCTION IND',,STRY PRACTICES. fill C* V, CL4 0 �z 0- \10 CAD FILE NAME ACAD\HAYES\LUZERNE\C0 SCALE in 401-0#1 DRAWN BY DRAWING TITLE B U 111L D I N OCATIO pi LAN li DRAWING No. —1