231736_20241008_CFI_0000236936Client:
Project:
Technician:
Date:
Weather:
1471 ST RT 9 LLC
1471 ST RT 9, Lake George NY
Partly Cloudy
Tuesday, October 8, 2024
Michael Daigle
Client Rep.:Russ Faden
Temperature: AM 60-70 °F40-50 °F PM
Arrival Time:
4:15 PM
10:30 AM
Project Number:
Contractor:
Contractor Rep.:
231736
JJP Slipforming
Troy Herron Departure Time:
Concrete Field Report (ASTM C31, C143, C231 or C173, C1064, C138; AASHTO T23, T119, T152 or T196, T309, T121)Page 1 of 1
3348 Route 208, Campbell Hall, NY 10916 ■ Phone: 845-496-1600 ■ Fax: 845-496-1398
12960 Commerce Lake Dr #14, Ft Myers, FL 33913 ■ Phone: 239-204-4569
1813 State Route 7, Harpursville, NY 13787 ■ Phone: 607-235-2006
877 US-4, Schuylerville, NY 12871 ■ Phone: 518-372-4067
Report Reviewed By: Juan Gomez
Mix Details
Supplier Strength Cylinder Type Initial Curing Method Mix Design
Bonded Concrete Inc.3000 PSI @ 28 Days 4 x 8 Cylinder Field Cure J4
Project Specifications (On File At Advance Testing Company)
Structure Type Required Strength Slump Slump w/MRWR Slump w/HRWR Air Content Unit Weight Mix Temp Maximum Mix Time
Curbs 3000 PSI @ 28 Days 0.5 - 1.5 in.4.0 - 8.0 %
Placement Information
Load
Num.
Truck
Num.
Ticket
Num.
Cubic
Yards
Total
Yards
Time
Loaded
Time
Arrived
Time
Discharged
Time
Completed Slump Air
Content
Unit
Weight
Mix
Temp
Air
Temp
H20
Added
Num
Cyls Location
1 88 4005124 8 8 2:50 PM 3:10 PM 3:20 PM 1.00 in.5.0 %72 °F 61 °F 6
Curbs Along Route 9 in
front of 1471 State Route
9
All tests within specifications.
Comments
Client requested only Roadside Concrete be documented/ Tested for DOT.
Technician released prior to completion of placement.
General Location of Work:
Curbs Around Building at 1471 St Rt. 9
Technician Signature:Date:Tuesday, October 8, 2024
ACT-CFI-1, Rev 2, 10/13/20The results identified in this report relate only to the items sampled/tested.
No representation is made that materials or items not sampled and tested will produce the same or similar results.
This report shall not be reproduced, except in full, without the prior written approval of Advance Testing Company.