Lot 45 Dean Thomas Way Blow Cert This home has been professionally insulated with
Owens Corning'
PROPINK'L77 Loosefill Insulation
(Job Site Address)
Name
Address Lot 45 Dean Thomas Way
city Queensbury State Zip
Owens Corning. PROPINK' L77 Loosefill Insulation
Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by installing the required
number of bags at a thickness not less than the labeled minimum thickness.Installation of the required number of bags may yield more than the specified minimum
thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value.
Specification for Open Blow Attics Coverage charts are based on a nominal net bag weight of 32 lbs.
Attics
,,,, J�trfrraUrr�tr��laf��a((k���������Mrntm�r��e�fled �fa�rrr�u�U�riverag� ,Mrntttzurr���gs„, �ffnJrr�}�m1N�aght ,„
New Construction ® Retrofit ❑ �ai�e rrrkne�stesy,, rtt�ne&sttmesi,,,�� eeBag( �r�} eltiousyft �bs� sy.f.},
13 4.75 4.75 184.6 5.4 0.173
19 7.00 7.00 125.0 8.0 0.256
22 8.00 8.00 106.3 9.4 0.301
Number of bags 26 9.25 9.25 89.6 11.2 0.357
32
used 30 10.50 10.50 77.0 13.0 0.416
P3S 13.25 13.25 59.9 16.7 0.534
4 15.00 15.00 50.7 19.7 0.631
49 16.75 16.75 45.0 22.2 0.711
Estimated R-value 60 20.00 20.00 35.8 28.0 0.895
of previous N/A
insulation Walls
�� � IIed7lYr�kKes� fastall�€7Ensfiy (N�;kimamf�a�� M�imu��Zga ,��7�>tt4��lghf
14 2x4 3.5 1.25 87.8 11.4 0.364
Area of coverage 15 2x4 3.5 1.45 75.7 13.2 0.423
g 1920 16 2x4 3.5 2.20 49.9 20.1 0.642
(sq.ft.) 22 2x6 5.5 1.25 55.9 17.9 0.573
23 2x6 5.5 1.35 51.7 19.3 0.619
24 2x6 5.5 1.75 40.0 25.0 0.802
Other type(s)of N/A Floors
Insulation In attic alua..,,,"' parrying" MIKmU tir����������Cn�fa112d�EnSiY �%��£� GfXQ� M41 wafizgSPpY Ml t �gh4
Thfaknass{X a arr tt P r fag ,,,ffiaa�y .,,, Ins rre*41
30 2x8 7.25 1.35 39.2 25.5 0.816
38 2x10 9.25 1.35 30.8 32.2 1.041
46 2x12 11.25 1.35 25.3 39.6 1.266
Thickness of 13.25
insulation
Cathedral Ceiling y
iviiiiiiiiillletlpnnSfi �Nl�%In£nrrE Col�k� �4JIffillrt3 cgs Pp�Y Ml�f ��nlght
iiatalli ,,,,������Thi�ktl�ss X��rksFRo,Iti peY P ,,,,, ,,,f 4Gp s
30 2x8 7.25 1.35 39.2 25.5 0.816
Depth of previous 38 2x10 9.25 1.35 30.8 32.5 1.041
insulation N/A 49 2x 12 11.25 1.85 18.5 54.2 1.734
Loosefill insulations vary in thermal performance due to factors such as aging,mean temperature,settlement,convection,moisture absorption and installation variation.
Convection in glass loosefill insulation installed in open attics can reduce its thermal performance in extreme winter temperatures during the heating season.
Contractor Thermally Yours Date 12/13/24,i/der Cerrone Builders Date
Company Company
(Signature) (Signature)
Address 149 Plant Rd., Haftoon NY 12065 Address
Phone 518-312-0859 Phone
OWENS CORNING INSULATING SYSTEMS,LLC
ONE OWENS CORNING PARKWAY
TOLEDO,OHIO,USA43659 Pub.No.10012954-B.Printed inU.S.A.October 2016.The color PINK isaregistered
® 1-800-GET-PINK" trademarkof Owens Corning.Cc2016 Owens Corning Insulating Systems,LLC.AII
www.owenscorning.com Rights Reserved.