2006-212 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 CL Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060212 Date Issued: Wednesday, March 19, 2008 This is to certify that work requested to be done as shown by Permit Number P20060212 has been completed. Location: 477 SHERMAN Ave Tax Map Number. 523400-308-008-0002-048-000-0000 Owner. ALFRED L VAN GUILDER SR Applicant: ALFRED L VAN GUILDER SR This structure maybe occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the n property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BU ILDING PERMIT Permit Number: P20060212 Application Number. A20060212 Tax Map No: 523400-308-008-0002-048-000-0000 Permission is herebygranted to: ALFRED L VAN GUILDER SR For property located at: 477 SHERMAN Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ALFRED L VAN GUILDER SR 7 FULLER Rd Residential Addition $5,000.00 Total Value $5,000.00 SO. GLENS FALLS, N.Y. 12803 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2006-212 432 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,May 05,2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn of rz�w i y 05,2006 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE ONLY TAX MAP NO.:).)D22 (�0 ` �1�' —z— —� , PERMIT NO. ZOG�s) —2._x 7 FEES: PERMIT b RECREATION ENGINEERING CE)-3 ;?a5 (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: 1 i_if. OWNER: A RME__ ADDRESS: -1 F Rn ADDRESS: \ \V- PHONE NOS. 7Ct131-7 PHONE NOS. 79 i -2_c6c-,-?, kAct- CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:TriFF NRMiu C EE (..?-k-1519 LOCATION OF PROPERTY: y-( 1 F 1 a1 'R\e SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z 0 c d o IL PROJECT O o • J OI— _ ori CL eU o Z_ 0 Z Q Q r0 N � . 20u SINGLE FAMILY u TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COSTCS1POD FUEL TYPE: !J fl-1-69, k_ 1-3fil) HEAT TYPE: c-b,Q[.EV) (k1cl, *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: t- O—k ck` 7_ (")iEDR. � *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"availablern our office B 3-LGL 11-05 Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read andr e to the a.•v-. Signed xqg / '' 37.56 Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction . codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: ,Ai" iii 1 ILIO ( ,. CODES APP-v i L ZONING APPROVAL 2'ATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codesaqueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net Town of Queensbury • Community Development Office ■ 742 Bay Road, Queensbury, NY 12804 � -3 rRi -- - 0 6 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: 6 Queensbury Building&Code Enforcement Arrive: _am/pm Depart:\aam/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: VL--(K) NAME: V �Ur PERMIT#: 6 Z I LOCATION: L-1 - 5e INSPECT ON: — TYPE OF STRUCTURE: e`�by T Comments YV N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place e Footing Dowels or Keyway in place '\ Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Firestopping Inspection Re s ort Office No. (518) 761-8256 Date Inspection re► e. -ed: Queensbury Building&Code Enforcement Arrive: ', lI I ',ep. 1 V.51:;ai 742 Bay Road,Queensbury,NY 12804 Inspector's In i. ::!",�.311 /IF NAME: �(p,,�Gv SER PERMIT#: LOCATION: INSPECT ON: FO, TYPE OF STRUCTURE: 9E-) . 0 Y N NIA COMMENTS Framing Attic Access 22"x 30"minimum i Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/a(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade t zk -ts-i- z_vtA cu--.:;:-----A-50 Rough Plumbing I Insulation Inspection Report Date Inspection reques re,ei •d: �� Office No. (518) 761-8256 p q Queensbury Building & Code Enforcement Arrive: `:: it) a . /pm D:'art: V:,i-r)am/pm 742 Bay Road, Queensbury, NY 12804 Inspectors Initials /! NAME: \((a►;GOO i-,C)ER PERM' 06 —Z1Z LOCATION:/477 ���t_1 -tt�0 ( 'i v- INSPE - ON: "7-7-0(0 TYPE OF STRUCTURE: V, il7-4) - A00 Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head /0 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check F).002., Pr Pro.- Vent, Attic Vent Duct of .ter Pipin nsulation required unheated spa Combustion Air Supply for Furnace ;I Duct work sealed properly / No duct tape ' fit* COMMENTS: '1 1QE ..-- L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection que =-•iv-d: Building & Code Enforcement Arrive: ra �, `i:mart: �i�i am/o .. 742 Bay Road, Queensbury, NY 12804 Inspector's Initial _ NAME: \1A0 tLC7E PER #: LOCATION: '-+Y( F Rpt Po3 9 INS' `CT ON: 7 — m—d( TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head /50 P.S.I for 15 minutes V Insulation esidential Check) Commercial Check Firx Proper Vent, Attic Vent Xuct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace IDuct work sealed properly/ No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 /T3 Th * f Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date Inspectio equest recei Queensbury Building&Code Enforcement Arrive: ` • Ism ?„5.. •: r _ L-ft Ips 742 Bay Road, Queensbury,NY 12804 Inspector's Initial • NAME: jce_vx V VI f ERMIT#: 06 -212_ LOCATION: 4 - PERMIT ON: 7- /-- TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/4(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 2 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade /v -1z rrrCelFraming / Firestopping Inspection Re Office No.(518) 761-8256 Date Fns.ection r- - ecei -.. l Queensbury Building&Code Enforcement Arrive: ' ►r'��. ►.:.art: \,-=�aitipm� 742 Bay Road,Queensbury,NY 12804 Inspector's InitiaOr 14k- ` t)/ PERMIT#:NAME: �e #.1 /2 LOCATION: V'�`� '/r '1f e_ . INSPECT ON: 1 —_ — 7 TYPE OF STRUCTURE: /I 0 ‘ _.---- Y N /A "Framing / COMMENTS Attic : • ess 22"x 30"minimum \( Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls 1 0 iM al Strapping for Notches Top Plate %z(w) 16 gauge(8) 16D nails each side raft stopping 1,000 sq. ft. floor trusses chor Bo 6 ft. or less on center ! r e and waters eld 24 inches from wall separ • n 1, 2,3 hour Fire wall 2,3,4 hour L_____ Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No.(518) 761-8256 Date Inspectionrequest received: 2. Queensbury Building&Code Enforcement Arrive: .6)5 am/pm) Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: CJ NAME: V,��✓ (‘'y l L E PERMIT#: 06 7-C 7i LOCATION: 7.Y&to MAA/ 6- , INSPECT ON: l' )(l ' 07 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 milpoly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /A0(-3 Rough Plumbing / Insulation Inspe ion Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: J NAME: /fit L" vflr _ PERMIT #: I -- _ a LOCATION: , i -t INSPECT ON: /C-/3-- TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place _ 1 1/2 inch minimum Drain Size _ Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent 1 Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes e&_, 1_ (A-: lie?,g Pressure Test Water Supply Piping kic 4 Al t 0 P. '.I for 15 minutes Insulation / sidential Check / Commercial Checkti _ oper Vent At't+c Vent Duc H Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Queensbury Building & Code Enforcement - Residential Fin- spection Office No. (518) 761-8256 Arrive: i P •. ►part: i . •m Date Inspection request received: Inspector's Ind NAME: (',`\t 1 nF PE' IT#: (c Z1 7 LOCATION: 14•71 '.h \ 4F R Nt Rel RJ F D 'E: 7 — —0(6 TYPE OF STRUCTURE: Comments: Yes�No N/A G) 4" Building Number Address visible from road /•✓/: � A ��� k=0Z-O ttCZ- Chimney Height/"B"Vent/Direct Vent Location l � �� ����F Fresh Air Intake 4.1�G��� 3 inch Plumbing Vent through roof minimum 6 inches �t�� Roof Complete/Exterior Finish Complete rC Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade �\lvv\ L7 Guard at stairwell at 34 inches or more �t 1 Guard at deck, porches 36 inches or more n� —C-f\-13‘2 ?AL) Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches ---�-�,,n, Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet / 6 inch clearance to sill plate J (,k. Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy l trim 1 doors I main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Ditectors/Carbon Monoxid"Detectors Every level: ,/ Every Bedrq m: Outside every bedroq(n area: • Inter Connected: JJ Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil-Furnace shut-off at entrance to furnace area ^ 1=um atefr Heater operating 6) ater shut off boiler V1� Relief Valve(s)installed/Heat Trap!Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing 1%hour fire door/door closer Duct work Sealed properly 110 (..://f/ Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C/0[Temporary/Permanent 1 L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final inspection Form_revised_100405.doc;Revised January 7,2008 Queensbury Building & Code Enforcement - Resi - ti 'nal Inspection Office No.(518)761-8256 Arrive:• 1 9 •art: y Date Inspection request received: Inspector s Ini . NAME: V ci 1 P' ' IT#: t(—2-k LOCATION: L-\-'7 7 1-N ERM tt$ MF ') •TE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches _ Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing �^ Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents _ Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 :/// Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&CodesUnspection Forms\Residential Final Inspection Form_revised_100405.doc