2006-221 �` TOWN OFQ UEENSBURY
742 BayRoad,Queensbury,NY 12804-5902 (518) 7 1
6 8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20060221 Date Issued: Thursday, July 19, 2007
This is to certify that work requested to be done as shown by Permit Number P20060221
has been completed.
Tax Map Number: 523400-297-007-0001-005-000-0000
Location: 31 CHESTNUT RIDGE Rd
Owner: GARY & SUSAN HIGLEY
Applicant: GARY & SUSAN HIGLEY
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the (-- 44194
45(.---
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
r
OFFICE USE ONLY
TAX MAP NO. ao"17. 7 / T3 PERMIT NO. --2e2D10 I
Cb
FEES: PERMIT /S RECREATION ENGINEERING
(If applicable)
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER:C 1f x COni$ -TrL.. OWNER: �j - U_- V1.O,‘e
ADDRESS: PO (o` - ley . 1\N ‘'Ki ADDRESS: C Sin., `' RA 1_ Rd.
PHONE NOS. 1 'c 'tia PHONE NOS.
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: 0%311-
PHONE: 361-0(0 ,j
LOCATION OF PROPERTY: 3i OrNeR�d(J.
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT
APPLY TO YOUR z cL O Cl E L
PROJECT OOH O • J Ci) =
e _a a o
w o - Z a 1- t- Of-= mow
uC9 -
z < < cn N v7 O U. }- U- CL oo
SINGLE FAMILY5D5b _S-DS
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE -
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: t 50,OQD FUEL TYPE: N# ' 'AL C-41
HEAT TYPE: 5D11-(32- *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? 1\c�
IS THIS A HISTORIC SITE? No
PROPOSED USE OF BUILDING OR ADDITION: Y.ITC* e
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys'availa1e in our office
B 3-LGL 1 1-05
;_? Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 140
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed \r
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alts-the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Applicatio .
•
:UIL0tNG CODES AP'-•u "AL ZONING APPROVAL
/h
DATE DATE
QUESTIONS? CALL 761-8256 OR EMAIL
codesc queensbury.net
VISIT OUR WEBSITE FOR MORE INFORMATION
www.queensbury.net
,_ . Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
imokbA y 6r 2 - d6
Foundation spection Report
Office No. (518) 761-8256 Date Inspection
Queensbury Building&Code Enforcement Arrive: I C- Cr. Depart: m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initia :
NAME: //i�J t P RMIT#: 06— 22
LOCATION: L/ /r 3/ C/eri U INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. /
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
- 4
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection request received: 6 - /5--_06
Queensbury Building&Code Enforcement Arrive: am/p6Depart: \i�am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: Z. �
NAME: /4t-5 PERMIT#: ()i - 2_27_I
LOCATION: 3/ /es/ 07 f) e INSPECT ON: C - / -O
TYPE OF STRUCTURE: J
Comments
Y N N/A
Footings
ers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place -
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
l- (Rib/1Y 6 - C)6
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: -27-66
Queensbury Building&Code Enforcement Arrive: am/pmDepart i r)am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: 61k A-1.)
NAME: C _ PERMIT#: O "_22 1
LOCATION:_2_ _ ( "1.eSI��=f i$icAc. INSPECT ON: (,-; --3p.-Q4
TYPE OF STRUCTURE: J
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
?frf pe for wet areas under slab c c . -.
C —ft-Backfill Appr val
Plumbing Under Slab ^` ' - _
PVC/Cast/Coppery :
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins.ection r-• e.'ed-
Queensbury Building&Code Enforcement Arrive: .`. _ t,:, r e..rt: a
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: f
NAME: 141(--,L H PERMIT#:
LOCATION: al C E b`"`T1.5T .D E RI) INSPECT ON: _?1—
TYPE OF STRUCTURE:
Y N NIA COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft. floor trusses
chor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sfrade
-3 77-/OR5 /0 s 01 ) .
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:Z;t am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:6yu,
NAME: I Elf, PERMIT#: s–22
LOCATION: J 1 h ON •10 e' INSPECT ON: 4/Mini -
TYPE OF STRUCTURE: i
Framing COMMENTS
Atti
:cess 22"x 30"minimum
Jack Studs/Headers
22->L e
Bracing/Bridging iM ` kMS t 5
Joist hangers
Jack Posts/Main Beams V P —
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I 'A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side ''A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
3 . L )Eb,JSZ2 'I _ , /6///./66
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: ," am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ekk---.)
NAME: /e PERMIT #: _14:74ciL.
LOCATION: '✓ l ',� / C 1�S�Yiv� lc� INSPECT ON:
TYPE OF STRUCTURE: NA--
Y / * N/A
Rough Plum ping Nail Plates V
a . -- :*- : � - / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
rai / Vent
/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
dk) Diaz
COMMENTS:
L:\Pam Whiting\Building&Codes\lnspection Porins\Rough Plumbing Insulation Report revised Nov 17 2003.doc Revised February 15,2005
-I; 77VR3, i4 /2%
Rough Plumbing / Insulation Inspe tion Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: Zi' 2.0a ml pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 7
NAME: 6-,T„ vN-Q . PERMIT #: ' -72. 1
LOCATION: ' A-6-7-1 A _ INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A_
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air - =-d
• 1 .I e 15 minutes
Insulation Residential Check / Commercial Check —�
••- sent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS: IR — ) c,
fl6a— 21431
z, 1
L:\Pam Whiting\Building&Codes\]nspection Forms\Rough Plumbing insulation Report.revised Nov 17 2003.doc Revised February 15,2005
....._
NTHE INSPECTOR
7063 State Rt.374,Chateaugay,NY 12920
1-800-487-0535 www.theelectricalinspector.com
V Date:January 11,2007 Application No.On File:040603
III
THIS CERTIFIES THAT Cifone Construction
Only the electrical equipment as described below and introduced by the applicant named on the above application number in the premises of:
31 Chestnut Ridge Road Town of Queensbury
In the following location: Basement X .l"Floor X 2id Floor X No.of Apt Garage Attic Outside X Commercial Residence X
Was examined on 12/22/06 and found to be in compliance with the requirements of the National Electric Code.
GFCI Fixture Outlets Receptacles I Switches Fixtures Ranges Cooking Decks Ovens Dish Washers Exhaust Fans Smoke/Heat
Incandescent Fluorescent Other Amt. K.W. Amt. K.W. Amt. K.W. Amt. K.W. Amt. K.W. Detectors
2 36 34 33 36 1 1.5 1 FR 2
Dryers Furnace Motors Dimmers Water Heaters Unit Heaters Multi Outlet Sys. Electric Heaters
Amt. K.W. Oil H.P. Gas H.P. Amt. Watt Electric Oil Gas Amt. Rating No.of Feet Amt. K.w. Amt. K.W. Amt. K.W. Amt. K.W.
8 600
Transformers Alarm Systems Special Receptacle Panels Motors Signs Track Lighting Disposal
Amt. KVA A/V PS Det. Panel Amt. K.W. Amt. No.of circuits Rating Amt. H.P. , Amt. No.of Lamps No.of Heads Amt. H.P.
1 32 200 6 1 FR
1 9 60
Service Disconnect Equipment Service
Amt. Amp. Type Meter l Phase 1 Phase 3 Phase 3 Phase No.of CC. AWG. No.of AWG.of No.of AWG of
2W 3W 3W 4W CondJphase CC.cond. Neutrals Neutrals Ill-Legs HI-Legs
Other Apparatus
Manager
This certificate must not be altered in any manner;return to the office of THE INSPECTOR if incorrect. Inspector's credentials can be verified
JLC - 1Z_ lik)edt\es //
Queensbury Building & Code Enforcement - Residential Final In ection
Office No.(518)761-8256 Arrive: am/pm D rt: Vam/pm
Date Inspection request received: Inspector's Initials:
NAME: / PERMIT#: t
LOCATION: z3 f k- ,j - 'o - DATE: ;INN'
TYPE OF STRUCTURE: _ d7
Comments
Yes No N/A
Building Number/Address visible from road c)—/
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake y01) /�G 0 yvvr-
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade ��� _ l.�l�/
Guard at stairwell at 34 inches or more / (�/-1
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
( yH /e )
Interior/Exterior Railings 34 inches to 38 inches1.4,1/17: J
7/;--
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet _-
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety.glazing/Window in stairwells safety glazing y
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans, if no window
Plumbing fixtures _
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum 1/2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/a hour fire door/door closer
Duct work Sealed properly '
Gas Logs in Sealed or Glass Enclosure b\f-p'��'
Final Electrical till
Final Survey Plot Plan I t
As Built Septic System./Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc
Town of Queensbury 742 Bay Road, Queensbury, NY 12804
Jila
-rl
Building & Code Enforcement Building Permit 2006-221
Higley Addition
Phone:(518)761-8256 Date:5/4/2006
Fax: (518)745-4437
Email: codes@a,queensburv.net
Dear,Joe
The Higley building permit application has been reviewed and found to be deficient in the following areas.
1 /he specifications are needed for the remaining window in the existing 2nd floor bedroom and if it meets the 5.7 sf
egre requirement. Also the removal of the other window may not leave the required amount of light and ventilation
fo his bedroom. Provide light and ventilation requirements for this bedroom.
ease provide handrail and guard details for deck and handrail on existing stairs to second floor.
dd note on plans that grade drops 6" in first 10' away from foundation.
_ Tease provide 22"x30"attic access on 2nd floor.
pered glass required in windows at 2"d floor master bathroom.
6 oam insulation must be covered with a minimum of%2"gypsum board in crawl space
lease show on plans smoke detectors in each bedroom new and existing, on each floor level including the crawl
space. Also show carbon monoxide detector outside bedrooms at lowest sleeping level.
Please feel free to contact this office with any questions regarding this matter.
Sin - e , Ar
AILD' Gfr .s4pi
FILE
/.il -
/ f
\\BIGRED\Users\johno\My Documents\Residential Plan Review.doc
"Z_C\0(0 —22J QVC L EKM VE 00 4 Cti-� P1D(,E_
Check Residential Plan Review: One & Two Family Dwellings
Y/N/ A
(2)Full sets of plans
Over I,500 sq. ft.-Stamped
/V Design Loads On Plans: 90 Wind Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
_7 Window Schedule With Glass Size ���
�E��� rti7:% L I)
• Door Schedule/Main Entrance 36"Door C3'eiaZtal
Emergency Escape Or Bedrooms and Habitable Space ��
- • > Above/Below grade,5.7 sq. IC=sera\1 1 L 7_0) '� '
Grade,5.0 sq.ft.
24' (h)z20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
/ Dampproofmg/Waterproofing Materials On Plans
V/ Foundation Drainage On Plans,if required
V__*, ' Drop in 10'Exterior Grade t�OT �>rtt� n� PuA6 pLOti� Ln' i t.,,1,31 µ)M of
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Fjv p piRT‘O 1.. 1�Rll.-
Required
EX-RJ_30P-E
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
�-Stairway Headroom 6' 8'All Stairs 36"Width
Stair Rum and Rise ,
Winder Run and Rise '
,
IV rc
i`Spiral Not Allowed From 2°a Story
_ 7'Smoke Detectors Battery Backup and Proper Location Z0� rn ,,`
V// Bathroom Fixtures Proper Clearance
�
V Hall Width,36"min.
._______ Handrails More Than One Riser On Open Sides
>
Railing and Guards>30"I Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas `''� �`
T \2R)
ES t�; V \ t.;�tc, DCx , e:.0 i TQ M
0 CF-
Garage Fire Separation
Garage Floor Sloped
______t Attic Access
UCLQ7 'Z tab c.LOO - f Y1Cv ,kisEi7�
Roof over 30"-22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Ft)Rm %,0bk.)‘=PrnD03 ti A06 v, co)E P �) 1 „ C_cL
05/04/2006 THU 09: 55 FAX 5187454437 Community Development 2001
*********************
*** FAX TX REPORT ***
*********************
TRANSMISSION OK
JOB NO. 0179
DESTINATION ADDRESS 95800018
PSWD/SUBADDRESS
DESTINATION ID
ST. TIME 05/04 09: 54
USAGE T 00' 48
PGS. 2
RESULT OK
4001110k TOWN OF Q 1JEENSBURY
742 Buy Road, Queensbury, NY. 12804-5902
COMMUNITY DEVELOPMEN2' OFFICE 518 - 761 -8221
FROM THE DESK OF:
❑Marilyn Ryba(-8221) ❑ vid Hatin(-8253) ❑ Gary Stillman (-8205)
❑Craig Brown(-8218) John O'Brien(-8255) ❑ Michael Palmer(-8206)
0 Stuart Baker(-8222) ❑ Joel Clugstone(-8254) ❑ Joe Lombardi(-8202)
❑George Hilton(-8217) ❑ Sandy Kruger(-8256) 0 Maria Gagliardi(-8219)
❑ Pam Whiting(-8220) ❑ Sue Hemingway(-8238) ❑ Bruce Frank(-8226)
❑Barb Edmunds(-8221) ❑ Susan Barden (-8265) ❑ Charles Dyer(-8207)
DATE: �` L`_0(0 #OF PAGES(not inc.cover):
#: � 1`
CC: FAX#:
❑ URGENT 13-4-6R REVIEW C] PLEASE COMMENTASE REPLY
TOWN OF QUEENSBLIRY
742 Bay Road, Queensbury, NY. 12804-5902
COMMUNITY DEVELOPMENT OFFICE 518 - 761 - 8221
FROM THE DESK OF:
❑ Marilyn Ryba(-8221) ❑ I Hatin (-8253) ❑ Gary Stillman (-8205)
❑ Craig Brown (-8218) [I John O'Brien (-8255) ❑ Michael Palmer(-8206)
❑ Stuart Baker(-8222) ❑ Joel Clugstone(-8254) ❑ Joe Lombardi (-8202)
❑ George Hilton (-8217) ❑ Sandy Kruger(-8256) ❑ Maria Gagliardi (-8219)
❑ Pam Whiting (-8220) ❑ Sue Hemingway(-8238) ❑ Bruce Frank (-8226)
❑ Barb Edmunds (-8221) ❑ Susan Barden(-8265) ❑ Charles Dyer(-8207)
DATE: \5_y._()Co #OF PAGES (not inc.cover):
TO: •(_S FAX FAX#: ) - I(6
CC: FAX#:
❑ URGENT EOR REVIEW PLEASE COMMENT EtPLEASE REPLY
ROD \- \`bk
c t C_HEbT -
COMMUNITY DEVELOPMENT OFFICE
•Animal Control 518.761.8202 • Building&Codes 518.761.8256 • Executive Director 518.761-8221
• Fire Marshal 518.761.8206 • Planning 518.761.8220 • Zoning 518.761.8238