Loading...
2006-388 TOWN OFQ UEENSBURY Fog742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060388 Date Issued: Monday, July 09, 2007 This is to certify that work requested to be done as shown by Permit Number P20060388 has been completed. Tax Map Number. 523400-295-015-0001-019-000-0000 Location: 15 MOORWOOD Dr Owner. RICHARD & ELIZABETH ENGLAND Applicant: RICHARD & ELIZABETH ENGLAND This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the 4 , " property owner of the responsibility for compliance with Site Plan, cDaNP Variance, or other issues and conditions as a result of approvals by the @c Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. 401" TOWN OF QUEENSBURY t 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060388 Application Number: A20060388 Tax Map No: 523400-295-015-0001-019-000-0000 Permission is hereby granted to: RICHARD & ELIZABETH ENGLAND For property located at: 15 MOORWOOD Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RICHARD & ELIZABETH ENGLAN 15 MOORWOOD Dr Residential Addition $18,000.00 QUEENSBURY, NY 12804-0000 Total Value $18,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2006-388 168 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday, July 06, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Towrfinsbuip Th r d ,July 06, 2006 SIGNED BY for the Town of Queensbury. Director of Building&Code Enticement 29 / 5-r ; OFFICE USE ONLY r RECEIVED_ TAX MAP NO. PERMIT NO. -3 a JUN 0 7 2006 FEES: PERMIT RECREATION ENGINEERING TOWN Or uzuccNSBURY (If applicable) ; BUILDING AND CODE PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: `ion ien. ti-,- OWNER: le►4-1f tj �Jf�� U Ft-3 "T-if ADDRESS: ..6-7 k) &"35720-0C-- 4i t ADDRESS: /S- 6-c35 r-Ru-S PHONE NOS. ..5"i7 . 7'f.3 - /S/?8- PHONE NOS. 6 r 2- - ZZo / 6.1 c rte la.za. A-r CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 5-7 w ; Feat. PHONE: 7'/3 ,1 "77 6. , LOCATION OF PROPERTY: / !`1'404-w utp SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z Q w rn PROJECT P g O O • auj Q u. ¢ O U o Z Z O ¢ 1- d NU Ou_� F CL cts SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST:/P o d C) FUEL TYPE: 671.--S HEAT TYPE: 'r',4-rZ_ *HOW MANY FIREPLACE(S): ' ' AND/OR WOODSTOVES(S): 4 '71 ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? /4'/° IS THIS A HISTORIC SITE? /v PROPOSED USE OF BUILDING OR ADDITION: /5A--7-74- t- z.2-/ *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 eb Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ,c9 ARE THERE EASEMENTS ON PROPERTY? AID I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. 1/- Signed ez..c..1-.Wace.. Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE 1 QUESTIONS? CALL 761-8256 OR EMAIL codesaqueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net tab Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Fj—j Queensbury Building & Code Enforcement Arrive: am/pm Depart:gr am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (,n,(A) ( ` ) NAME: c�1 PERMIT #: �_� - LOCATION: f<f/lcor x'J INSPECT ON: /-0 . TYPE OF STRUCTURE: Rough Plumbin Nail Plates u mg ent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pr- . - - Dr. - 4 - Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head for 15, minutes nsulation esidential Check / Commercial Check _\1/4/////:: ••- lent, Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: Ve, `CA., \FL- 3 L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 i , `"- Rough Plumbing / Insulation Inspection Repor Office No. (518) 761-8256 Date Inspection request received: / I -7/0(,, Queensbury Building& Code Enforcement Arrive: am/pm epart`Z Cr cam/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:�( n,�� �} NAME: A c, I FA1\I D PERMIT #: 3 LOCATION. l ',-) YN1 U O lt/U(n) 17 /2- . INSPECT ON: Vi'VQ,2 TYPE OFp STRUCTURE: _ ill rvl I7 t n� Y N N/A PVC: R-1, R-2, R-3, R-4 Drain/Vents _ Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/ Nail Plates 1 '/2 inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Y\ 1. -- { L � �� Drain and Vents r `( 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/ Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape sc- COMMENTS: ' '. ) Vf--) , q (...... L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 1.—3 7vfs,)/17 2 �- Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date Inspection request received: 7-2 5-7(o Queensbury Building&Code Enforcement Arrive: am/pm Depart' 14't�m/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: FVt y/ / PERMIT#: 4c:26- 388 LOCATION: Jf$ �l lb-)OOc/ . INSPECT ON: 7 -2_5--,06 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing is Accesscss22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and water shield 241-ches from wall. • ire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 0 - Z__... i---ir P Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/pm Depart:7 am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: (�, J V NAME: PERMIT#: —=3B LOCATION: M.0-0 i .1, ) INSPECT ON: TYPE OF STRUCTURE 44)D Continents Footings Y , N hi/AJ Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing ooting Drain Daylight or Sump Footing Drain Stone: 12 inch width 17 6 inches above footing 6 mil poly for wet areas under slab ^� Backfill Approval y...,...Tir umbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1Suellemingway\Building.Codes.lnspcctior..FORMSWoundation Inspection Report.doc January 28,2003 2 -fir TUESIAy Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: _ 7 ' / (X, Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: 4- 3�ff LOCATION: 'J / ,S jo�-rap INSPECT ON: ^ /1 TYPE /TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place 4 ' Footing Dowels or Keyway in place Foundation Dampproofmg � Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Pak&k— Q-1 k8i-- IG Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/p De artm/pm Date Inspection request received: 1 tD l 07 _ Inspector's Initials: NAME: 2 (�1w! PERMIT#: O t LOCATION: l Mour'I.�i;G _ DATE: , .7/4-107 07 TYPE OF STRUCTURE: 040(4.,461-"" Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing 17/ Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Aftic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq. ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 opci Enclosed Stairs Sheetrock Underside minimum V2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure � Final Electrical \e/7 Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_I00405.doc