Loading...
2006-514 Aek TOWN OF QUEENSBURY ` 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060514 Application Number. A20060514 Tax Map No: 523400-289-006-0001-033-000-0000 Permission is hereby granted to: DAVID & MARY LOU DUTRA For property located at: 28 NACY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DAVID & MARY LOU DUTRA ERCV Residential Alteration $8,000.00 2500 US 27 Total Value $8,000.00 CLERMONT, FL 34714-0000 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications $133.60 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, August 14, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Towr(61Tu nsbu f Mo a August 14, 2006 SIGNED BY _ for the Town of Queensbury. Director of Building&Code E •rcement FILE USE ONLY TAX MAP NO. PERMIT NO. 06 1 e -D FEES: PET 133 / RE ATION ENGINEERING (If applicable) TO 44 ---&JIB 4-1RY PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: OWNER: M R. avid k/ ADDRESS: ADDRESS: SNAG r- , p. . • I Z5 PHONE NOS. PHONE NOS. IT F S' CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: Of 1 7 ��r(� C�61 �ld.�rrr:, PHONE: 1� ' 8 X61 LOCATION OF PROPERTY: 0 Nf c r R o, 6_, of1 o ) /U " SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z 0 C! PROJECT o O w o w amu. ori w J¢ a = = u = I— O 0 z Z < < 7L, 1-Na OLL o f a = 65 SINGLE FAMILY 1006 AS 6 ,V /el/ TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST:�'J n',C6C? FUEL TYPE: Ve r 5"eflC HEAT TYPE:- Ail; *HOW MANY FIREPLACE(S): 0 AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? Ye5 67Z'Q L, h't, IS THIS A HISTORIC SITE? NO PROPOSED USE OF BUILDING OR ADDITION: RE 4 i ck,r1 u *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office 133-1,01.11-05 rth Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? fV0 ARE THERE EASEMENTS ON PROPERTY? Nb a I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree� to the above. ( GG Signed 'It (I " r Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: 40./ . 4tJi BUILS?IN 4 CODES AP-- I AL ZONING APPROVAL 6 ' —116 • b D• E DATE J QUESTIONS? CALL 761-8256 OR EMAIL codesaqueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net r Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: /'74./ am/p Depart: am/pm Date Inspection reques ceived: Inspector's Initials: NAME: c / �.I 0_44-1 PERMIT#: : • -•/ LOCATION: ZF A/c.,c n DATE: Ar/370 TYPE OF STRUCTURE: Comments: Yes N2 N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more V a,,t Cr. G Handrail Termination at Newell Post or Wall 3` ;, Interior/Exterior Railings 34 inches to 38 inches 0 o1 Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy I trim I doors I main entrance 36 inches Bathroom/Kitchen waterti•ht Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: __ Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms _ Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required _ Flood Plain Certification,if required Okay to issue C I C or C/0[Temporary/ ane ] L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08 . /0-/Z tykdheScia, ..b=tv-e__ Queensbury Building & Code Enforcement - Resid ntiai Final Inspection Office No. (518) 761-8256 Arrive: r9/i/ am/ /Depart: am/pm Date Inspection request received: ,w Inspector's Initials: i NAME: ,bIIir--- lei PERMIT#: (/_: '-+ — LOCATION: /.. _ DATE: � L�j TYPE OF STRUCTURE: _ %�� Comments: Yes No N/A �JJ •' 4" Building Number Address visible from road Co(�e Co r'..../J/1Q N C Chimney Height/"B"Vent/Direct Vent Location �/ // Fresh Air Intake11111 M� j KSped;01, . 3 inch Plumbing Vent through roof minimum 6 inches ■ fr '" I Roof Complete/Exterior Finish Complete �—_ rites 0 / e Platform at all exterior doors ) Handrail 4 or more risers MOM Guards at stairs,decks,patios more than 30 inches above grade IIM Guard at stairwell at 34 inches or more a� Guard at deck, porches 36 inches or more Iligi Handrail Termination at Newell Post or Wall MIMI Interior/Exterior Railings 34 inchas to 38 inches Mil� Deck Bracing/Handicapped Ramp Compliant Mil� Grade away from foundation 6 inches with 10 feet �_ 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above •rade .111NOM Interior privacy/trim/doors/main entrance 36 inches IIII� Bathroom/Kitchen watertight III � Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom are:: Inter Connected: Battery backup: _ Attic access 30 inches x 22 inches x 30 inches(height)in accessible area III Crawl Spaces 18 inch x 24 inch access, 1 ..ft.-150 s•.ft.vents El � Bathroom Fans,if no window EOE Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft sto••in! finished basement 1,000 s•.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site III Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating _�= Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern. 110 NM= � Enclosed Stairs Sheetrock Underside minimum'/:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched == Garage fireproofing/'/%hour fire door/door closer Duct work Sealed properly III � Gas Logs in Sealed or Glass Enclosure Final Electrical ii Final Survey Plot Plan = Arc Fault Breaker in Bedrooms _ Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required i v II Flood Plain Certification,if required Okay to issue C l C or C/0[Temporary/ •erman; ] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7, 2008; Revised 6/26/08 7EYbA1 ArrieflACOA--- Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: Mil am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: Vi NAME: r PERMIT#: I / - LOCATION: �� �G J DATE: • TYPE OF STRUCTURE: / Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more /' 'tea f� Guard at deck,porches 36 inches or more 1.7 Handrail Termination at Newell Post or Wall 6 41'cir7 Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers 170 id/ L i- Cv4 Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate '.�� Gas Valve shut-off exposed/regulator 18 inches above grade G, J Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke De tors: Every level: Every Bedroo . Outside every bedroom ar : Vrp Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping fmished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating _ Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/3 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary ; L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: `1�Zd am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: px, NAME: rakc PERMIT#: ,► •/, LOCATION: � INSPECT ON: /��'`7 TYPE OF STRUCTURE: Y ��A COMMENTS Framing Jack Studs/Headers Bracing/Bridging /Weil It rs Q 4 4 v S Joist hangers (/ Jack Posts/Main Beams 3� ,,� -I /A fxj Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) i 5.7 sf above/below grade 5.0 sf grade L\SucHemingway\Building.Codes.Inspection.FORMSWraming Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspecti99 request received: Queensbury Building & Code Enforcement Arrive: 3:76 am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: DOM-- PERMIT #: LOCATION: 2 kacy INSPECT ON: • TYPE OF STRUCTURE: YEN N/A Rough Plumbing / Nail Plates ✓! Plumbing Vent / Vents in Place VV 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check _ Proper Vent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: /O.7„, am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: C` NAME: �5 PERMIT #: ��- '/ LOCATION: 2� /"i., et, INSPECT ON: 94/76 TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2, R-3, R-4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. V / Plumbing Vent/Vents in Place 6/s43 " Rough Plumbing/Nail Plates ,` < ��� 1 '/Z inch min. Drain Size ,k d'k Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/ change of direction Water Supply Piping Cooper Commercial Cooper, CPVC, Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 0 6 - 5/1 28 Nacy Rd. First floor plan RECFNED IIILLco ° JUL ` 4 ` I ,ITOWN u, ..,___-_IN BURY \ /r 6'-O" ' - --18- ,, 10" BUILDING AND CODE 4-0"x 6'-8" Slab Foundation Porch 24'--6" - 4'-0" --I,' 12-3" -- 8'-3" yWN of QUE it,S:'URY J 0 3'-0"x 6'-8" 3'-0"x 6'-8" LDING & ' ' ' r .5 PT. 8'Block FoundationSurrounds n west,rrorth6 east wafts ortnls VIEWED B1111- ? O proom.NorthwaAofstair- s east& //�// �/O J Qsouth ort ofng 'Tf rI�_i J Ubathroorrr/bedroom,raconneci fo E c\i wN Q Owest wall of livingroom. !v Q G Diningroom Kitchen o rn L1J cp ALJ C'S > o x N ri t1 1— mw LU = O ra ¢ O c/7 12-2" I' p _.. 032MM2OULu V I.�L EL] W _ OO O (/) Double 1.97ri4'(mkcro/em)LVL C Z 0 I— I beams on quadruple jack studs to CO N . .r.,4¢ Lu L.0 C/) resuPPort 2nd floor I x 04 04 = ,, -JmvoLu N co .� O • " d x f— -6'-8" f 4-6" ,'- vi Z J � R Z � � � Co illimillimilmimmil..2. =0 r CI '4: - 6r Bathroom T LI, L7J < O Ja aV = ► A 11'-0" W O 0 c9 Triple 1.9'x9.5'(microlamm)LVL beam _ c1 2-2_X 3r-0"6a x 3r-0" on quadruple jack studs to resupport `� \ yam. 2nd floor `� —2-8„—X21-81 -2.-8"—, Bedroom 8'-0” as , / Livingroom .- .6:0 �' 12-015-8'? , ` `�., s, • o ��,�� I/I llI I f;(4, io 7.-9" — — 1 -8" Na�� 28.-0 , - 'i ► - - ! ► 11 - = . ! ERED "' y A 15 MINUTE THERMAL BARRIER r. ) E .... o..-6 41) Q Deck w/rail 4'x4'posts set @ 6' d S CO)-IS a ia ap centers on cement pyfons 4'in ground ;� y 1 4:1 N63 Cf) Zs3 a vou� 4/ va El a$2 12-0" NOTICE (11 CE r KRAFT PAPER INSULATION MUST BE COVERED BY NON-COMBUSTIBLE BARRIER Second floor 2'-6"x 3'-0" CNI N O C = Bedroom 2`-6"x 3'-O" 2'-6"x 3'-0" 8'-O" 12'-0" } 8'-O" � / - 28'-0" /