Loading...
2006-604 TOWN OF QUEENSBURY Flea 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060604 Date Issued: Monday, January 12, 2009 This is to certify that work requested to be done as shown by Permit Number P20060604 has been completed. Location: 6 PINE St Tax Map Number: 523400-309-010-0001-045-000-0000 Owner. PINE STREET TOWNHOMES, LLC Applicant: SCHERMERHORN RESIDENTIAL HOLDINGS, L.P. This structure may be oci 14 Apartments By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the �p property owner of the responsibility for compliance with Site Plan, ;,, �'r /-4e Variance, or other issues and conditions as a result of approvals by the Director of Building&Cod/Enforcement Planning Board or Zoning Board of Appeals. lek TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060604 Application Number. A20060604 Tax Map No: 523400-309-010-0001-045-000-0100 Permission is herebygrantedto: SCHERMERHORN RESID' N IAL HOLDINGS, L For property located at: 6 PINE St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot p ns an. .ther informat.en hereto filed and approved and in compliance with the NYS Uniform Building Codes •nd the Queensb oning Ordinance. T - of Constructi. Value Owner Address: PINE STREET TOWNHOMES, LL 11 partments $500,000.00 536 BAY Rd Suite 2 QUEENSBURY,NY 12804-0000 T-otal Value $500,000.00 Contractor or Builder's a e/Address Elect al Inspection Agency Plans &Specifications / 2006-604 BUILDING 4 8 UNIT APARTMENT BUILDING $1,281.84 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday, September 19, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn of z"..), // 2dayScptember 19, 2006 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 431 742 Bay Road,Queensbury,NY 12801-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060604 Application Number: A20060604 Tax Map No: 523400-3 09-010-0001-045-000-0000 Permission is hereby granted to: SCHERMERHORN RESIDENTIAL HOLDINGS, L For property located at: LUZERNE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SCHERMERHORN RESIDENTIAL I 536 BAY Rd Suite 2 Apartments $500,000.00 QUEENSBURY, NY 12804-0000 Total Value $500,000.00 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2006-604 BUILDING 4 8 UNIT APARTMENT BUILDING $1,281.84 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, September 19, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town eensbu Toe da , September 19, 2006 SIGNED BY for the Town of Queensbury. Director of Building& de EN..rcement Permit No. o6-4?))/ r'' Fee Paid /J Building&Codes Office-Deportment of Community Development-Town of QueensbUnk,, 7 742 Bay Road,Queensbury,NY 12804 " �C� Dave Hatin,Director codes©aueensbury.net � Recreation ee �L)QQ Phone: (518) 761-8256 FAX: (518) 745-4437 �`` Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder tvorit;0,#j4(/ ,'P '177AL Owner: 66,/776 Address: 66,3 &,a1 A 240 5//7 2 Address: Qt t1 $,3UOY NY /2S r Home Phone: -54143770-4( 27Home Phone: Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: 74.3-'r FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: ge/ /1VS,e/ ,OIG — //AL( Address: ,&27 /Y741 ,4y - 7a6 t921N6.S NY Phone "1161' Location of proposed construction: Lot No. Legal Address: 'Pi[ � Tax Map Number: . ID - I - Subdivision Name: Estimated Cost of Construction: $ Dot,/Zx., Proposed construction is for: Residential Use Commercial Use Name of Business: nit -1-1M14-10115C -1-pW14}Q115C If proposed construction is an addition, what will use of new addition be? N//d' New Addition Alteration Proposed Construction PI Floor 2^d floor Other Total structure (Occupancy Type) Sq. Ft. sq.ft. Sq.Ft. Square feet Height Proposed Single-Family Dwelling H.&in. Two-Family Dwelling Townhouse 4rt(0615 4f4 e - 9/1 (9 41-2" " Multifamily Dwelling / Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oil, eit, Wood, orced Hof A) aseboard, Other: If a fireplace and/or woodstove are being installed, please refer to a separate application. Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of .II ne tr ction. Date: /b 41/l, Z ' Applicant/Builder Signature:/ i - The application of dated is hereby permission granted for the construction, reconstruction or alteration of a building/and or ccessoryapproved ctu e assetand forth above. Date: Authorized Signature: L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: Rile St ..„. LOCATION:c RK-e. `free . PERMIT#: D 6 - 6 AP Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept.of Community V Development. Upon review the survey has be : 2 Craig rown, Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc .5U9.1 U-1-45 Inspection for Permit to Occupy Fire Marshal's Office Request Recd Permit No. iv Z /' Town of Queensbury 742 Bay Road I 1 14421 Queensbury,NY 12804 Scheduled Inspection Dat: Time:� Phone: (518) 761-8206 Business Name: ���e,e (1/!7 Fax: (518) 745-4437 Location: Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Sign—normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hung Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System Fire Suppression—kitchen Fire Suppression—Gas Islan Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electric• Electric Wiring Enck ed/Labeled Combustible Wast- Vehicle Impact Protection Knox Box F.D.Signage—Utility Rooms No Smoking Signs Maximum Occupancy Sign_ Emergency Evacuation Plan pproved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) o Denied / call for Recheck Ins. -cted By: L:\FireMarshal\New Folder\permitto occupyform.doc Inspection for Permit to Occupy Fire Marshal's Office Request Recd Permit No. D6 -‘7". Town of Queensbury Qu Bay Road /� jSGf �,7U Queensbury,NY 12804 Scheduled Inspection Date: i Are( Business Time: �J 7 Phone: (518)761-8206 Business Nam�e1 1�,�./�i�LLG` /*.::::. Fax: (518) 745-4437 Location: Z22 - , Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Sign-normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hung Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System IFDC) -)( Fire Suppression-kitchen Fire Suppression-Gas Islan Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical " Electric Wiring Enclosed/ abele Combustible Waste /747thé/®® /J 2.444/ ‘ie6//'f R/762___ Vehicle Impact Protection Knox Box F.D.Signage-Utility Rooms No Smoking Signs Maximum Occupancy Sign Emergency Evacuation Plan ❑ Aproved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) enied / call for Recheck 1 lnspec d By: ., a_�- L:\FireMarshal\New Folder\permitto occupyform.doc Multiple Dwelling, Hotel, Motel, Apartment Final Inspection Report Office No.: (518)761-8256 Date Ins•- tion r-. -- ved: Queensbury Building&Code Enforcement Arrive: a° .� �• r r, Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initi- .e ,/ NAME: 40--1,Ee e_R1-‘0PERMIT#: 4 .— $.4 LOCATION: CQ ‘f.,%•&, F__ c. E.ET- DATE: /IIIIMAI I 1301L<Di t G / COMMENTS: I i N NA Chimney Height/"B"Vent/Direct Vent Location J Plumb Vent Thru Roof Minimum 6" Roof Complete ✓ � Exterior Finish Complete/Finish Grade 6" In 10' Drop / Interior/Exterior Railings 34 Into 38 in./36" Landing, Decks, ,/J Porches Decks Braced / Exterior Handrails Stairs 4 or more risers both sides / ,/ Interior Handrails Stairs 4 or more risers both sides �// Guardrails 42", Ballisters 4" Minimum Spacing ,/ / Vestibules For Exit Doors> 3000 sq. ft. ii ti/Doors 36"/Lever Handles Headroom 6'8"on Stairs ✓` 1c2,e_ IA A(th -AAL b Bathroom/Kitchen Watertight ✓ Smoke Detectors: Carbon Monoxide \—V 'E -\b O ' Every level, Every bedroom Outside every bedroom, Interconnected Battery Backup Flex Gas Piping Bonded ✓/ Bathroom Fans/Plumbing Fixtures Complete ✓/` Foundation Insulation /Fire Separation, '/, 1, 2 hr. Fire Walls 1, 2, 3 Hour/Fire Door%,1 Y2,2 Hour ,/ Handicapped Accessibility/Handicapped Parking/Signage / Gas Log In Sealed or Glass Enclosure ,/ Gas Valve Shut-Off Exposed I Regulator 18"Above Grade Gas Furnace Shut-Off Within 30 ft. or Within Line Site Oil Furnace Shut-Off at Entrance to Furnace Area / Furnace I Hot Water Heater Operating I Fresh Air Intake �/ J Low Water Shut-Off for Boiler Relief Valve, Heat Trap I Water temp 110 Degrees Max. Garage Fireproofing Complete, Penetration Sealed �/� Furnace In Separate Room/Protected (In Garage) Light Ventilation per Room/Safety Glazing .4 ✓ Attic Access 30"x 20"x 30"(H)I Crawl Space 18"x 24" / Final Electrical/Arc Fault Breakers Sleeping Area ,/ Site PlanNariance Required Final Survey Plot Plan I Flood Plain Certification,if Req. / As-built Septic System Layout Required / (3F i_.R. ,// Building/Apartment 4" Number on Building or Driveway Build Access All Sides by 20', Drivable Surface 20"Wide ✓ Handicapped Ramps I Handiped-omits Okay To Issue Temp C or Permanent CO[cl le one] Okay To Issue C/C ,_ Last printed 11812008 2:32:00 PML:1Buiiding&Codes Forms-OLDDBuilding&CodesUnspection Forms MULTIPLE DWELLING.doc Revised January 7,2008 i _..:3 : 6:111 4 . Inspection for Permit to Ucc Y Fire Marshal's Office Request Rec'd Permit No. Ii - 0 / Town of Queensbury 742 Bay Road I ?-0? - Queensbury,NY 12804 Scheduled Inspection Date: Time: Phone: (518) 761-8206 Business Name: ier 'f-�"</d/1- -- Fax: (518) 745-4437 Location: 1 ili / 17/ 3vrL 1- , Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: 1-7 - e3k- Main Aisle Width Secondary Aisle Width EXIT SIGNAGE 4/._.1 - _,s�, . __-_=- - _ _ - - Sign-normal UF— 6�reGi +' Sign-battery 5 _Ok EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING x FIRE EXTINGUISHER: * -11 - Hung Ins ection of extinguisher r �� 1fr2. $ FIRE ALARM SYSTEM/ v� Fan Shutdown Fire Sprinkler System _ `- � ��"" Fire Suppression-kitchec�L'r�✓ U Are Suppression-Gas IslanrePL/ (� �i 5_r-A04-&-t- _ Generator 4/1 Hood Installation /C�L!"7' ' " W7i Elevator (� Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical A Electric Wiring Enclosect6abele Combustible Waste Vehicle Impact Protection Knox Box X F.D.Signage-Utility Rooms No Smoking Signs Maximum Occupancy Sign Emergen6cy Evacuation Plan Approved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) Denied / call for Recheck Inspec -d By: (1111 L:\FireMarshal\New Folder\permitto occupyform.doc f 3fI Multiple Dwelling, Hotel, Motel, Apart ent . Final Inspection Report Office No.: (518)761-8256 Date Inspecti••. -qu-• r: - •d: Queensbury Building&Code Enforcement Arrive: '.m/,.]u7' Depart:T.03nr 742 Bay Road,Queensbury, NY 12804 Inspector's I Ilial •�4' NAME: . r ork PE MIT#: 16 — 61( / LOCATION: /G( 4 CQ / f 1,i_ S7 4. PATE: /'�' • + ` (97 Y/ N NA COMMENTS: Chimney Height / "B" Vent/ Direct Vent Location Plumb Vent Thru Roof Minimum 6" I/ / Roof Complete Y Exterior Finish Complete / Finish Grade 6" In 10' Drop Interior/Exterior Railings 34 Into 38 in. / 36" Landing, / Decks, Porches Exterior Handrails, Balconies, Landing 30" Or More / Interior Handrails Balconies / Landing 30" Or More ✓ Interior Handrails Stairs 1 or More Risers Guardrails 42", Ballisters 4" Minimum Spacing ✓ / Vestibules For Exit Doors > 3000 sq. ff. Doors 36" / Lever Handles / Headroom 6' 8" on Stairs J Bathroom / Kitchen Watertight Smoke Detectors: Every level, Every bedroom �_� ���` Outside every bedroom, Interconnected Battery p)EQ Backup / 1Jts i 0-s-Evis2) Carbon Monoxide Alarm - lowest sleeping level ✓ Bathroom Fans/ Plumbing Fixtures Complete ‘,.*(/ �1 tA'\v___ _\im 27 Foundation Insulation Fire Separation, 3/4, 1, 2 hr. I NW U\'k_ Fire Walls 1, 2, 3 Hour / Fire Door 3/4, 1 'h, 2 Hour � Handicapped Accessibility / Handicapped Parking/Signage Gas Log In Sealed or Glass Enclosure Gas Valve Shut-Off Exposed / Regulator 18" Above II'Grade Gas Furnace Shut-Off Within 30 ft. or Within Line Site / Oil Furnace Shut-Off at Entrance to Furnace Area i ,/ Furnace / Hot Water Heater Operating / Fresh Air Intake Low Water Shut-Off for Boiler Relief Valve, Heat Trap /Water temp 110 Degrees Max. i Garage Fireproofing Complete, Penetration Sealed _ \(,/ Furnace In Separate Room / Protected (In Garage) Light Ventilation per Room /Safety Glazing Attic Access 30" x 20" x 30" (H) / Crawl Space 18" x 24" Final Electrical // Site Plan/Variance Required Final Survey Plot Plan / Flood Plain Certification, if Req. As-built Septic System Layout Required b � Building /Apartment Number on Building or Driveway Build Access All Sides by 20', Driveable Surface 20" Wide Okay To Issue Temp C/O or Permanent CO (circle one) Okay To Issue C/C L:1B&C APPLICATIONS-OFFICE USE\MULTIPLE DWELLING.doc COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MU ICI AL CERTIFICATE - ELECTRICAL APPROVAL ry`, Permit No.. ..0 ... � � q ...... ........Cert. Nd ,,� � 1 3Cut in Card No..................................... Owner. G` C C�� .C ....,... .............................................. Location...... ....... �. L......� ........................ ......... G L ...... U MC�r ! - Installatipogn Consisting of t ! .............................. }...j...................................,.......................................................................................................... Installed By...... ......................... ...........................................................Lic.No................................................... . The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin inspections at any time, and if its rules are violated the Company shall have the right t�ee. tifithicercate� .............. Date... f ......<:. .............. INSPECTOR........ .. ......... 1 ................................ Member N.F.P.A.,I.A.E.I. - 3 • Rough Plumbing I Insulation Insp ction Report ; Office No. (518) 761-8256 Date Inspection req - y - -•. Queensbury Building & Code Enforcement Arrive: I:50 a Or I - : :rt: Z° I p a • 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: C 6/a perkcy- " MIT #: 9LOCATION: `��� Sf . BLOC. LI- INSPECT ON: i ?h=off TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 '/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air ad P.S.I r 15 minutes Insulation / esidential Check/ Commercial Check ek imilar Exterior Sealant Proper Vent, Attic Vent -%\f/ Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7, 2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p f,pepart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ^ e;---le7/1,_ PERMIT #: ,r - /r • LOCATION: 574- INSPECT ON: 7.-2 /TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air Head .S.I. or 10 ft. above highest connection for 15 minutes Pressure Test ter Supply Piping Ai J Head 5D P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008 7Zyselx7 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins pti uest re ived: Queensbury Building &Code Enforcement Arrive: •' am/pm e 742 Bay Road, Queensbury, NY 12804 Inspector' Initials: .30 NAME: �` '�/�//!. f 'X ��" PERMIT#: I_ LOCATION: f, � fi INSPECT ON: "�'� —0 TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic A 22" x 30" minimum Jack Studs/ Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping C�� els 4/Ce- > Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'/ inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Forms-OLD1Buiiding&Codes\Inspection Form (Framing Firestopping Inspection Report.doc Revised January 7,2008 /D-- i Z 7vGS Dom. /0 -11 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins , i w'rrequest received: Queensbury Building &Code Enforcement Arrive: 6am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspect is Initials: �'fL�. NAME: PERMIT#: 0 ‘‘ —'4 LOCATION: , INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing cress 22" x 30" minimum ! LL jK + iC9 e— -f2 Jack Studs/ Headers Bracing/ Bridging Joist hangers Jack Posts 1 Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping � I,� PP 9 pLel C� �O p V4-Ale Penetration sealed 16 inch insulation in cavity min. 6 E C o�V.,.n/) to AC..L Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes FormsOLD\Building&Codes\inspection Forrns\Framing Firestopping Inspection Report doc Revised January 7,2008 /0— /Z Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pc am/p_ .art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ! PERMIT #: LOCATION: r/ 71 INSPECT ON: 9-22- - TYPE OF STRUCTURE: lY N , N/A Rough Plumbing / Nail Plates I ii 4(pu_ 1J k l(--- Plumbing Vent/Vents in Place ‘/ _ p„Acel-) k/-) 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum C4 � Cleanout every 100 feet / change of direction I Pressure Test [�raLn /Vent Air ead 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test ter Supply Piping Ai I Head 0 P.S.I for 15 minutes Insulation / Residential Check I Commercial Check j Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) _ Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15, 2005, revised January 7, 2008 V\& r'c ) - Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspect request received: Queensbury Building&Code Enforcement Arrive: ,) •l, amm, 0/pDepart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspectors Initials. \`-' ----- NAME: 46µGT PERMIT#: 06,01/ LOCATION: r"//1/ -;. INSPECT ON: Z /'� TYPE OF STRUCTURE: Y N NIA COMMENTS Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge (8) 16D nails each side / Draft stopping 1,000 sq. ft. floor trusses •ichor Bolts 6 ft. or less on center r1,G j 1�L� Vice and water shield 24 inches from wall Fire separation 1, 2, 3 hour L� At O L-FZ�K 6A-)17 Fire wall 2, 3, 4 hour �tyw-Q Firestopping Penetration sealed +�� 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade &9YL Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspeccn request received: _4_ _, e Queensbury Building &Code Enforcement Arrive: am/prr part: a /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (\ 1 NAME: S Ct\ed� PERMIT#: O LOCATION: gr—e--"T INSPECT ON:– d TYPE OF STRUCTURE: Z) 2s f2 IU ..e\ t Y N N/A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/ Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/Bearing Walls A,A)0(Metal Strapping for Notches Top Plate ` Q 1 '/z(w) 16 gauge (8) 16D nails eachside - Draft stopping 1,000 sq. ft. floor trusses Anchor Its 6 ft. or less on center and wat shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-OLD\Buiiding Codes\inspedion Fomu\Framing Firestopping Inspection Repoit.doc Revised January 7,2008 Framing / Firestopping.Inspecti n Report Office No. (518) 761-8256 Date InspeoplQn request received: Queensbury Building &Code Enforcement Arrived U V arnlin£r epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ] per.:40r) PERMIT#: LOCATION: Co + /d 1--) . INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22" x 30° minimum Jack Studs/ Headers Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses ; / {, or 13 16,ft. or less on center Ice and water sh Id 24 inches from wall 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side /2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-OLDIBuitding&Codes\lnspection Forms\Framing Firestopping Inspection Report.doc Revised January 7,2008 6:-/A4-7 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: ��77�� Queensbury Building&Code Enforcement Arrive: am/pm Depart:l t7 am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:61.&.7 NAME: Vl '(•f r� PERMIT#: I i► LOCATION: t �� S , INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foo' owels or • . in place Foundation Dampproofing •� on ` aterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing miT poly f r et areas under slab B royal Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM z 7b, Foundation Inspection Report Office No. (518)761-8256 Date Ins ection request received: Queensbury Building&Code Enforcement Arrive:t '(O am/ Iw n� / Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: tirIr' fli--- PERMIT#: Z/26-42 /// LOCATION: TuREp../te_ INSPECT ON: A. 97- TYPE OF STRUC Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab B. - .• - •va . / P1 bing Under Slab / Cast/C..: n �� -�() f foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. :\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM F‘i(C- u MIY-lit- oaf / - 3 moi , Framing / Firestopping Inspection Re rt Office No. (518) 761-8256 Date Ins ipn request received: �^ Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm l l 742 Bay Road, Queensbury, NY 12804 Inspect° s Initials: ___ NAME: l ,-- . r PERMIT#: Z:Z7Z1(2 LOCATION: f3/ V j . �7 INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22° x 30" minimum Jack Studs/Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches I Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side rafts pping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ..- Ice and water shiel 4 inches from wall \ c)7)NL'A $J (5:-- Fi ion 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space 1 Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Forms-OLD1Building&CodesUnspection Forms\Framing Firestopping Inspection Report.doc Revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection re• e eiv d: Queensbury Building&Code Enforcement Arrive: I; •2„:11 . Depart: r6:-K 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:1-1- NAME: C is I T#: 406— CO LOCATION: y' ST- . � 'J' SPECT ON: - r► TYPE OF STRUCTURE: JP/ (b-S( Comments Y N/A Footin: 'iers Reinforcement :!e The • s 'esponsible for • •• • ng pro•=01ion from freezing for 48 hours f' lowing the placement oft : conc 'te. fieri• - ="r-this-purpo on site. oundation/Wallpour • Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forrns\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection re I • - iv d: Queensbury Building&Code Enforcement Arrive: \-2:.-0) ' p: y ' Depart: • ' . 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initiav NAME: k rN �^ •ERMIT#: (2(f" /0 LOCATION: (�, {24,r\A_ INSPECT ON: I_ TYPE OF STRUC 1 Val‘.11A-)‘Ob Comments 6 "1 o� Y N N/A p ootings O Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. <47 Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place / Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM