Loading...
2006-633 4 ` TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060633 Date Issued: Friday, August 24, 2007 This is to certify that work requested to be done as shown by Permit Number P20060633 has been completed. Location: 28 NORTH Ln Tax Map Number. 523400-226-019-0001-059-000-0000 Owner. GARNER HOLDINGS Applicant: GARNER HOLDINGS This structure may be occupied as a: Fireplace By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the / property owner of the responsibility for compliance with Site Plan, , Variance, or other issues and conditions as a result of approvals by the Director of Building&Code nforcement Planning Board or Zoning Board of Appeals. IOWN OF QULLNSISUKY `A 742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060633 Application Number. A20060633 Tax Map No: 523400-226-019-0001-059-000-0000 Permission is hereby granted to: MICHAEL CHRYS For property located at: 28 NORTH Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAEL CHRYS PO BOX 172 Fireplace SCHUYLERVILLE, NY 12871-0 Single Family Dwelling $275,000.00 Total Value $275,000.00 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2006-633 2768 SQ FT SINGLE FAMILY DWELLING & 1 FIREPLACE $332.16 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, October 27, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the TownrQt1 nsbu FreyOctober 27, 2006 SIGNED BY `l (,14/ , for the Town of Queensbury. Director of Building&C&le E :roement 06.- 633 OFFICE USE ONLY TAX MAP NO. PERMIT NO. PERMIT FEE 1:RECEI\i' APPROVALS: ZONING TOWN CLERK SEP 0 7 2006 ,. 'dGEL-M3URY APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT'1 irG AND CODE A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. tA 1 OWNER: t' I��& `/imoi!\(r2� INSTALLER: ADDRESS: ADDRESS: PHONE NOS. PHONE NOS. LOCATION OF INSTALLATION: YEAR BUILT NO.OF # , _ RESIDENCE INFORMATION: BEDROOMS j X COMPUTATION= TOTAL DAILY FLOW 1980 or older I i 1 GARBAGE GRINDER I X 150 gallon per bedroom I = INSTALLED? • 1981 -1991 ( # X 130 gallon per bedroom = SPA OR HOT TUB 1992 presentJ X 1 110 gallon per bedroom i = I INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL • (IF WELL: WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. ) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANK: GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH FT. ✓ TOTAL SYSTEM LENGTH: FT. SEEPAGE PIT(S): HOW MANY? ✓ SIZE OF EACH FT. X FT. ✓ SIZE OF STONE TO BE USED: # /DEPTH OR THICKNESS FT. ✓ BED SYSTEM SIZE: X ✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE ✓ HOLDING TANK SYSTEM: (If required) NO. OF TANKS: /SIZE OF EACH ✓ GALLONS./TOTAL CAPACITY: GAL. NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. , ,,,,,,,,,,,,iii..::,.: ,,,,,,:,,.,.,.,:..,,...,,,,,,.,,:,,,,.,, , :,..,.,,,,,,,.,.,,:,,,,,,, „.,.nnwm,•,v.,.,.,.,•,•,•,.,vv.,.,.,•nvil For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761.8256 OR EMAIL Queensbury Sanitary Sewage Disposal Ordinance. codeseaueensbury.nef VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Signature of Person Responsible Date et Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ......................................... OFFICE USE ONLY TAX MAP NO. -2. 6 I PERMIT NO. C C 5 ' ' Date FEES: PERMIT , / - RECREATION ._._._ENGINEERING ; ............................ ......................(If�{.... ..PRINCIPAL . ; 1 amp STRUCTURE: APPLICATION FOR ZONING APPROVAL & B A PERMIT MCONSTRUCTION.APPLICATION IS SUBJECT TO UST BE OBTAINED BEFORE BEGINNING �I'T'DAG PERMIT BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: -� �i` L_ �i'-yr v OWNER: X ( '?2 . ADDRESS: •-----.__ ADDRESS: /C'l'/ le,'C-./icJ • 4�r PHONE NOS. - • PHONE NOS, CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: SUBDII/ISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z 0 i co APPLY TO YOUR PROJECT O i= ct C p ILI CI. UNz Q < :- g o � E-° aO2 = �. SINGLE FAMILY == a,rn.7e4 108 TWO-FAMILY MULTI=FAMILY (NO.of UNITS` TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,S) OTHER e IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: f Z ESTIMATED CONSTRUCTION COST: l �,^ ''`�c ' /1c,94 ft ef /�� z /' - c� .�FtIELTYPE:y/ /'"'C�f"�, gyl,'r HEAT TYPE: 4,.'�`,> !r-4�*HOW MANY FIREPLACES): AND I OR WOODSTOV • ES(S): ZONING CATEGORY: ./t ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? u PROPOSED USE OF BUILDING OR ADDITION: S,N, �t �j�-c<<, l Glc cc/NC— *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 `' Town ofQueensbury• ''°` ° Q ry Community Development Office • 742 Bat/Road, Oueenshijrt, MV 1 QnA ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and. complete statement/description of the work proposed, that allwork will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in. conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to Issuances of a certificate of occupancy. I have read and agree to the above. Signed Dir actor of uildi• � - ,!' des: •761.8266 kfor'questions.regarding Building Permits, construction codes or septic systems Zoning Administrator 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) rr.., Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said Application: z°Hing Laws of the Town of Queensbury. • BUILDING &CODES APPROVAL ZONING APPROVAL DATE DATE QUESTIONS 7 CALL 761.8256 OR EMAIL ogsmatmensbtt VISIT OUR WEBSITE FOR MORE INFORMATION weltainatagmratt Tozcm Of Queensbury• Community Development Office , 742 Bay Road, Queensbury, NY 22804 TOWN OF.QUEENSBURY .. HIGHWAY %%._ 633 Richard A. Missita Highway Superintendent DEPARTMENT RECEIVED Houle(518)798-5127 742 Bay Road * Queensbury,NY. 12804 SEP 0 7 2006 Michael F. Travis Deputy Highway Superintendent Office Phone:(518) 761-8211 TOWN OF QUEENS3JRY (518)798-0413 Fax: (518) 745-4466 BUILDING AND CODE DRIVEWAY PERMIT DATE: APPLICANT NAME: P�, L VB' e,5 TELEPHONE NO.: 9751-1`)C551 11.1-100 ADDRESS TO BE INSPECI ED: 1i16 Reitz0 1 RETURN ADDRESS: k98t_ rt6(L(SP1/4t Pcdti.r (tis -ir(utiA 1'1,ho1 Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: SI EP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Level with the road ( ) Deep swale Size pipe to be used (if necessary) ( )12" ( )15" ( )18" ( )24" ( )36" Preliminary inspection completed by DATE Approval by Highway Supt. Deputy Supt Upon completion, please resubmit this approved permit for a final approval. S I EP 2: ( ) Final Approval ( ) Rejected DATE: Richard A. Missita, Highway Superintendent E-mail:highway@queensbury.net Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: ! . am/pm tAepart: am/pm Date Inspection request received: _ Inspector's Initials: �!!�-v NAME: AlPERMIT#: C/c` LOCATION: /1.).1,41/-i C.... 1 DATE: 917 C/D'� TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Futnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s) installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum 1/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly 45' - Gr/L Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] 41/ L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc 14 ,icQueensbury Building & Code Enforcement - Residential Final Inspection OfficeOfce No. (518)761-8256 Arrive: /8t/(f am/p Depart: am/pm Date Inspection request received: - Inspector's Initials: NAME: `� )� PERMIT#: (/t . LOCATION: "'U/�� k-{' DATE: 7-- TYPE —TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete _ Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade _Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight I Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents j Bathroom Fans,if no window ,� UUh9 o t,e' r&I" Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. 6v6,. V Emergency egress below grade — S, _A. A4V T"<��1 ei Gas Furnace shut-off within 30 feet or within line of site �i Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler _ Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%s"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required 1//// Okay to issue C/C or C/0[Temporary/ ermanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc -KeekeZik_ Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm epart: am/pm Date Inspection request received: Inspector's Initials: NAME: 4V9i-_ / PERMIT#:LOCATION: L-„(,` DATE: 7Lfd TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing // ha./Interior Smoke Detectors: ,-d/1luve / Every level: Every Bedroom: T Outside every bedroom area: lhah- Inter Connected: Battery backup: Carbon Monoxide Detector _ � edit. Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq. ft.vents J„ Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure _ Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: 3(1/Ci)a pm part: am/pm Date Inspection request received: Inspector's Initials: NAME: C k ' _ PERiMIT#: 69 LOCATION: .44fftYL /. A/ DATE: 5/2- /87 TYPE OF STRUCTURE: _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake J� 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete 4-1 4 i � I Guard 30 in. or more @ stairs,decks, patios C�- Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete ,^ Interior/Exterior Railings 34 in. to 38 in. ✓ �' B , e- Platform at all exterior doors t/ Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum 1/2" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area i�,�,_� 41/6,, ,�l Furnace/Hot Water Heater operating AilkoW ll�'v�'t/9� 1 6 (045U Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. r 6-65112/—O I- &kv- Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required 9f53 Okay to issue C/C or C/0 [Temporary/Permanent] L:1PamW'Building&Codes\Inspection Forms\Res. Final Insp. form 2,docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: L # )aniite.�ep . am/pm Date Inspection request received: Inspector s Imhals. V�`-�. NAME: ► AY S PERMIT#: LOCATION: APArit DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete _ PIatform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches _ Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: (/ ` Inter Connected: Battery backup: " , \,- ) Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area v e$'�tk Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents Bathroom Fans,if no window VI - Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade \, Gas Furnace shut-off within 30 feet or within line of site (1 ry Oil Furnace shut-off at entrance to furnace area �` r Furnace/Hot Water Heater operating (\ i Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 �Q,� fit" ` Enclosed Stairs Sheetrock Underside minimum 1/2"Gypsum rC` Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly 66e- C`IA-1� ,:13/20(c).0 Gas Logs in Sealed or Glass Enclosure • Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:1Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Offi. No. (518)761-8256 Arrive: 3 . 2 am(p De art: am/pm Date Inspection request received: Inspector's Imtiats'` NAME: Citia`/ &rer PERMIT#: 06 A3. . LOCATION: N&r . DATE: _ TYPE OF STRUCTURE: St4 Comments Yes No N/A /Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake iainch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors_Vfauar ds at stairs,decks,patios more than 30 inches above grade ✓ Guard at stairwell at 34 inches or moree..iq.$G 6-A/( /Guard at deck,porches 36 inches or more V andrail Termination at Newell Post or Wall _Interior/Exterior Railings 34 inches to 38 inches tenor Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches _ Afathretyoogml /Kitchen watertight azing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Avc ame —19). 61,914,-0K Bathroom Fans,if no window Pfix Foundatilumbingon insulaturestion _ Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''h"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed orli E losure Final Electrical ?) 7 L�,�p(/-� ✓ ,,QQ�,�, /Final Survey Plot Plank l� kKe'w tj As Built Septic System/Sewer Dept.Inspection Sticker 9tvo cle -fj R 45(1.ED Site Plan /Variance required Flood Plain Certification,if required rPe, :Lr�C- K Okay to issue C/C or C/0 [Temporary/Permanent] Ne/ /t/e& .Z )lr(, hiCo& —oF - L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residentia inal nspec io Form revised 100405.doc r Final Survey Inspection Dept. of Community Development Town of Queensbury9 742 Bay Road Queensbury, NY 12804 Date received: 2006-633 MICHAELCHRYS 28 NORTH LANE SINGLE FAMILY DWELLING TAX ID 226.19-1-59 • Final Survey Plot Plan The attached final survey has been received by the ?76. i?.- I-57 j f Dept. of Community Development. Upon review the survey has been: r 1 Craig rown, oning Administrator Notes: L:\SueI!emingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc MAP REFERENCE: MAP OF LANDS OF J05EPH N. PAR151 DATED OGTO13ER G, 1985 BY GOULTER + McGORMAGK .34 AREA 11,211.30 sq. ft. 0.26 acres '9( 9 9 TEMPOPA'yKY LEAN-TO in NcjAPP, 0F 'tocArlON 10% SEP GA rlc)-414� N 2;STOPY WOOD FRAMED HOUSE Z, C-0 CRUSHED STONE I 2. q4' To DRIVE ORETO S L,41VC SEPTIC DESIGN GN ON ,,FILE WITH TOWN oJ 361 0 Non LEGEND 0 IRF = IRON ROD FOUND 0 IPF = IRON PIPE FOUND 0 = WELL c -Q) = UTILITY POLE RECEIVE-) T0VV N U9 B U I L D I I G A`„'' C Date: JUNE 7, 2006 Scale 1'=20' ®1 SHEEr 1 OF I GARNER HOLDING5C-1822 DWG. NO. 06144 "UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP REARING A LICENSED LAND SURVEYOR SEAL ISA of a Survey made for & VIOLATION OF SECTION 72 SUB-DVASIONS2, OF THE NEW 'iORK EDUCATION LAW. rap 4 10-24-06 STATE 'CHLY COPIES FROM THE ORIGINAL OF THIS SURVEY 3 10-04-06 Steves 2 MARKED NTH AN ORIGINAL OF THE LAND SURVEYORS K4 SMALL BE CONSIDERED TO BE VALID TRUE COPIES.' 4 1 7-28-06 ADDITIONAL WETLANDS .CLlfl[IFICAPCNS INDICATED HEREON SIGNIFY THAT TH15 �YRVFY WAS PREPARED IN ACCORDANCE VATH THE Garner Holdings Laiad S -u r -ve Ex[�FJIR3 CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED BY YSTATE ASSOC4ATIQN OF PROFESSIONAL yc)rs LAMP tURVEYONEWORRS,K SAID CERTIFICARONS SHALL RUN 014LY TO Pit PERSON FOR MOM THE SURVEY IS PREPARED. AND 169 Haviland Road Queensbury, New York 12804 ON fif§ BEHALF TO ME TITLE COMPANY, GOVERNMENTAL ACEtjC'r AND LENDING INSTIrUInON LISTED HEREON, AND TO flit Town of Queensbury, Warren County, New York ASSIGNEES OF THE LIENCINGINSTITUTION.` 518) 792-8474 New York Lie. No. 50135 J RECEIVE-) T0VV N U9 B U I L D I I G A`„'' C Date: JUNE 7, 2006 Scale 1'=20' ®1 SHEEr 1 OF I GARNER HOLDING5C-1822 DWG. NO. 06144 5 81-01-07 HOUSE LOCATION 4 10-24-06 PROPOSED HOUSE 3 10-04-06 PARCEL AREA 2 9-5-06 PROPOSED HOUSE 1 7-28-06 ADDITIONAL WETLANDS NO.J---- DATE - DESCRIPTION RECEIVE-) T0VV N U9 B U I L D I I G A`„'' C Date: JUNE 7, 2006 Scale 1'=20' ®1 SHEEr 1 OF I GARNER HOLDING5C-1822 DWG. NO. 06144 g---- /0 11401,---910-1 . Queensbury Building & Code Enforcement - Residerifial Final Inspection , .-6/ Office No.(518)761-8256 Arrive: 9, :, am/pm CDepart: am/pm Date Inspection request received: Inspectors Initials:NI e-- � NAME: rA,....( /4o/ 6. PERMIT#: ___Z241'� �V LOCATION: S A c�r �. DATE: -- - _ n TYPE OF STRUCTURE Comments Yes No N/A Building Number/Address visible from road 0.)66t. htov54 1/46 Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches f / Roof Complete/Exterior Finish Complete ✓ �Oti.,,1P�G� - 5 D fiV� Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade / cc_)4-rAii&u4c Guard at stairwell at 34 inches or more v .5r--daGuard at deck,porches 36 inches or more / /Cn o E.04-e---c- Interior/Exterior Handrail Termination at Newell Post or Wall /P4rrufZ� t/L ( Interior/Exterior Railings 34 inches to 38 inches /V.."." � ���f✓ L Il„fib Interior Handrails @ stairs 2 or more risers �Ty Grade away from foundation 6 inches with 10 feet / ear_� j� Q /( , c Q4t 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade ✓� Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight , / Safety glazing/Window in stairwells safety glazing G-”(Nj7c(..0S AsZp ii II'f3 /1--&C-9 Interior Smoke Detectors: .4 154:--C P ---2(--I> Every level: Every Bedroom: / Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area ✓ Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents // Bathroom Fans,if no window 77 ✓ Plumbing fixtures Foundation insulation f„icJ , Floor truss,draft stopping finished basement 1,000 sq.ft. ,�, Emergency egress below grade V Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area 1/ Furnace/Hot Water Heater operating ✓ ! .AAX.A A5� a T lX_r{�t, Low water shut-off boiler l/ rlG Relief Valve(s) installed/Heat Trap/Water Temp 110 / / M0L - Pel-C(' Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches I Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly , / / Gas Logs in Sealed or G ss E closure f /t 'r 2�Q'!(1 Final Electrical ( / -7 `/'�/� t/ (/ Final Survey Plot Plan f ' c43 h.t'' `�C vC fAs Built Septic System/Sewer Dept. Inspection Sticker CRS/(.2pu^f V Site Plan /Variance required ���� ! Flood Plain Certification, if required / ,L At1�1 G Okay to issue C/C or C/01 Temporary/Permanent] I'd)5r40- /14,e04-(--- (141* 1kol•6 �.. L:\Building&Codes Forms1Building&Codes\Inspection Forms\Residential Final Inspection Form_revise 00405. oc APIlialki Town of Queensbary Fire Marshal A/OP.Z,y, / 742 Bay Road `' Queensbury,NY 12804 761-8205/761-8206 _ fax 74S-4437 Factory Buil GasFireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or sp 'Beauo is is all ed. Permit# —0122 Schedule Inspection Time ,�� am pm anytime Inspector Jif zr Name 1(kileA' Address i( +vJrl L '1-01"` Rough In Final6e-r-i-t-N a _! Y • ` A 4' Appliance Man acturer ' ". P Model# 40(ex-- 0 ' 3 7 7Direct Vent t Factory Built Chimney_ Flue Size Dot.ble Wall Triple Wall Insulated Yes No ' N/A 1 Comments Floor Protection 1 I r ---- 7 Clearances to Combustibles (all sides) 06 k,-, 14-T6- 1--/ZA w� l (3C Y+irestop(s) Vertical Chase_ 1 i A (%.- 4,k0 Uo t �i �✓ Wall Penetration 1 Vent Clearances to Combustibles I Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Of Valve Combustion Air Hearth Extension (if any) Mantel • Height above f/p opening Witness Operation - Tank Placement (if LP) _ -- White—Building Dept. -- Yellow—Customer ; Pink—Fire Marshal l 3 7r3d . S'10/07 . Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: /0 am/prm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 1 'C� 11. NAME: Cit � r (i't r e RMIT #: a(-633 LOCATION: ,k) L� 34— SPECT ON: TYPE OF STRUCTURE: Y _ N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent r, , Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test — L(, R Water Supply Piping f, _.d P.S.' fo 15 minutes Insulation / residential Check / Commercial Check T� • ••- • -nt, Attic Vent V/ Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspec io�rtequest received: Queensbury Building&Code Enforcement Arrive r am/pDepart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspect° nitials: d---'--- NAME: (-,AR/�C 2 PERMIT#: i/y4 _,-a 7., LOCATION: AJ 6 2 f k L-,) INSPECT ON: Sf'f/b7 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire eparation 1, 2, 3 hour F. ewall2, 3,4hour Firestopping ✓ ✓ 4.9oPenetration sealed / 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report G} ✓1 6 Office No. (518) 761-8256 Date Inspection re uest received: Queensbury Building&Code Enforcement Arrive:[_��j� am/pm epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspect 's Initials: _JQ- NAME: igie/iMide PERMIT#: —6;33 LOCATION: Woo.2.111 L .J INSPECT ON: S 0 7 TYPE OF STRUCTURE: Y N NIA COMMENTS Framing Attic Access 22" x 30" minimum ✓ IDKO nq - AC- C ��Jack Studs/Headers Bracing/Bridging M it\ 0 ird Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"D.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour tire wall 2, 3,4 hour / eat,1/4_1(gt Firestopping A D/5 c u SS J Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'i/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X 47::4)ci- , Ceiling/wall 6(L 't(� 4i _- RK . Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade g'-'/O /i d i s/3/0 7 Framing / Firestopping Inspection Re ort Office No. (518) 761-8256 Date lnsp--tioequest received: Queensbury Building&Code Enforcement Arrive : ` am/pm epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto s Initials: S NAME: (i inner— /j)iIJJt.&12S PERMIT#: /2LOCATION: 2E- brtH— e _ INSPECT ON: _ - TYPE OF STRUCTURE: 7 Y N NA Framing J COMMENTS is cress 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate { 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour F. a wall 2, 3,4 hour j Firestopping t/q-L /L CO 112 o(--6-5 Penetration sealed �-------- 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms C � 24 in. (H) �� AIC / 4 J 20 in. (W) 5.7 sf above/below grade 5.0 sf grade ! ` MO i&-4-.44- Framing 4- Framin / FirestoPPirn Ins ecti n Report Office No. (518)761-8256 Date Inspectio 'request received: Queensbury Building&Code Enforcement Arrive:}V am/ m Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspectors Initials: �/ NAME: / PERMIT#: _ ,� LOCATION: INSPECT ON: • TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses or . or less on center Ice and water sh. d 24 inches from wall V Fire separation'1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade _ A im Frid„cy Framing / Firestopping Mspection Report Office No. (518) 761-8256 Date:;_ns ecti re received: Queensbury Building&Code Enforcement Arrive: 0 p De art: am/pm 742 Bay Road, Queensbury,NY 12804 Inspect 's Initials: p NAME: Cif' 1\/ PERMIT#: 0 —AS LOCATION: 'T2 ri k- /o'A.-Q._ INSPECT ON: TYPE OF STRUCTURE: Y r: N/A COMMENTS Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses I / / V ,1 I7Anchor Bolts 6 ft. or less on center ,� J l�.' 44- Z L_ /4�/2/�J7),,V gL 104.Jh 17{LIce and water shield 24 inches from wall Fire separation 1,2,3 hour 1 Fire wall 2, 3,4 hour I lRbw iS ,�c�-� C:tip^J6)14 Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 2 -2-/ 11:0 4/2 /o 147) Rough Plumbing / Insul tion Inspectiony Rrt Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p ,Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 61 1_�' Q I 3 . PERMIT #: 64:3Z LOCATION: /Or yv INSPECT ON: TYPE OF STRUCTURE: Y /A Rough P Nail Plates umbing Vent/,Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum V 'u 1 T - — /A) Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 4r //LOiS /// ils()7‘ Framing/ Firestop mg Inspection Report Office No. (518)761-8256 Date Inspept�request received: '- Queensbury Building&Code Enforcement Arrive: e am/pr Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: .���`J`/V� NAME: l 1Q rft of 4-) PERMIT#: 7 - LOCATION: $ ArV INSPECT ON: TYPE OF STRUCTURE: Y 1_v /N/A COMMENTS (4) (7- 1=vS-���- r3 �c (�v C)0P6-1e2"x 30" minimum _ ( Jack Studs/Headers /�'U 4 &/1)0 AT ( 2 r - Bracing/Bridging ! A--1rk Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. 14171-1� A C Ce 45 Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour /Firestopping Penetration sealed 16 inch insulation in cavity min. } A7 A\>\)\-r i or -L C) I tQi/0(_ ) Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 11-8. No' ///2y0F Framing / Firestopping Insp ction Report Office No.(518) 761-8256 Date Inspection quest received: Queensbury Building&Code Enforcement Arrive: 0... atDepart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials:: NAME: 6rj1e r / PERMIT#: 06' -6'. LOCATION: p ft� INSPECT ON: TYPE OF STRUCTURE: Y N I N/A F-.ming COMMENTS At ' ccess 22"x 30"minimum -r2 &S 5 5� `"� & ' OK Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fi separation 1,2, 3 hour ire wall 2, 3,4 hour C —s. ' c.4A)`5 Firestopping Penetration sealed `7L eqt A L[_ Zooe( . ) "P� FiaCQs 16 inch insulation in cavity min. Garage Fire Separation PROV( 7 6— 4TOP ,'4-t- -1,, ,, -(1, CC-1 1_( NCS House side Y2 inch or 5/8 inch Type X �� Garage side 5/8 inch Type X --f U,..) Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 7-// Jt ///Z3/07 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ 7- Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials• NAME: � r er-' Aid r S PERMIT #: 06 - LOCATION: 2J9S ,,)Dr/ Iv INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum -.nou :very 100 feet / change of direction ure T:st to .', •ent it Head • .S.I. or 10 ft. above highest connection for 15 minutes Pressure Test meter Supply Piping Air / Head \1P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check _ Proper Vent, Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 g f 6 4///7/0. Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Intro.a nest received: Queensbury Building&Code Enforcement Arrive: epa -: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: ( 11PERMIT#: 06— � LOCATION: r7 � INSPECT ON: TYPE OF STRUCTURE: ' r / Y Eid N/A COMMENTS Frami � (� j Attic Access 22"x 30"minimum y' °Ukk-x 1 RE'V P4- 4() "3/ Jack Studs/Headers :� �"^�� (A)/>1 .66 '7 E7//4-- Bracing Bracing/Bridging "� Joist hangers j,J l(.A C/ -I N&- PE2 MA-`.JU Jack Posts/Main Beams Exterior sheeting nailed properly C'5 . L)j6— APPI''i O k b .N4 le_ 12"O.C. �� Headroom 6 ft. 8 in. Stairwells 36 in. or more / Headroom 6 ft. 8 in. i �Pl',D U 1 b c j R v Gj Notches/Holes/Bearing Walls PRa0 it--4— I L i6tCc.6:-- Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire w 2, 3,4 hour Firestopping /lie( fieEn b`/) en 'vn-sealed' 16 inch insulation in cavity min. i- Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade e-ioAm L-1 //74) Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ rry) �epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �J NAME: ( � % PERMIT #: 06_�33 LOCATION: 2- A)() r IA-e . INSPECT ON: TYPE OF STRUCTURE: Y N iN/A Rough Plumbing / ,ail Plates / Plumb' - / Vents in Place rl Lv c.7rG— "1-7/z inch minimum Drain Size Uc � _ ger Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction ;Pressure Test J Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes 4 /e� Pjessure Test /Water Supply Piping A // V" Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check _ Proper Vent, Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 7- 3 TA3 -7-Xiisciovi / /1rloff- . Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart/ am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: !' 1k4 [ ! 1 NAME: f PERMIT#: 06--.633 LOCATION: a vi-Q INSPECT ON: TYPE OF STRUCTURE: Comments Y ,'N N/A Footings F Piers y Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour `f Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: l 12 inch width - ci ting j 6 mil poly for wet as under slab ' .. . a Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Suilding&Codes\Inspection Forms\Founda ion Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report S 'y''`--,._ Office No.(518) 761-8256 Date Inspectionuest received: )Z� D 6 Queensbury Building&Code Enforcement Arrive: � le)am/ppp 12L/Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspect° s itials: (1 NAME: ( ( �/d' • 5 PERMIT#: D()— 63 LOCATION: 2s- N o -`r (I 1- 'Pr INSPECT ON: 'ZAlifirtlii TYPE OF STRUCTURE: Comments Y N N/A Footings Piers ,j,Monolithic Slab ) Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 1 inch width inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Irispection Report j ( : o Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: i/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials' y NAME: CIA.QH 5 PERMIT#: 06, _ ,.;1 LOCATION: 11)-o 2 -i-` L Ai i INSPECT ON: /1.- /2_2-1 0 CQ TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg oundation Waterproofing Footing Drain Daylight Z.--- Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report P I Office No. (518)761-8256 Date Inspectio- equest received: Queensbury Building&Code Enforcement Arrive: p �` Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector s.Initials: C./ NAME: C &( - i 5 PERMIT#: 06 "---- C;. .- LOCATION: .LOCATION: Ale/al-4--r C _ INSPECT ON: l — Zt ( C Cell TYPE OF STRUCTURE: l( Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg F0.o ndation Waterproofing / (24-R,77 Doting Drain Daylight or Sump \../ Footing Drain Stone: 12 inch width i /c41 6 inches above footing /1U LK/ 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Fors\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM SS" — / f ifv s /?/.2. f Foundation Inspection Report Office No.(518) 761-8256 Date Ins do equest received: Queensbury Building&Code Enforcement Arrive: pm1/�;; Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's itsals: ,. !`' NAME: Chry-5 / PERMIT#: (9 6 LOCATION: -2R- /JUrtk lel i € ,INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place z /Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump .L Footing Drain Stone: / 12 inch width 6 inches above footing V ly for wet areas under slab Backfill A proval ------/A-1,c,i kL um mg Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Farms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM F 1 Foundation Inspection Report //, Office No. (518) 761-8256 Date Ins. tio uest received: I t 416°4'' Queensbury Building&Code Enforcement Arrive: - /p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspec o 's Initials NAME: A }` r PERMIT#: a00 33 LOCATION: i/pN _ INSPECT ON: (uy . _b„, (9 aOO(c2 TYPE OF STRUCTURE: S r Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. r ose on site. ., Foundation/Wall i/ Reinf peak lace Foot' g Dowels Keyway in place Founda ion Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. (518)761-8256 Date Ins tion�cequest received: Queensbury Building&Code Enforcement Arrive:2- am/pn} Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: C94 � PERMIT#: - LOCATION: -rw. nJ INSPECT ON: Z I 0 - TYPE OF STRUCTURE: / Comments Y _ N NSA Footings1 �C&�U I Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Bullding&Codes\Inspection Forms\Foundation Inspection Repoitdoc Last printed 12/20/2005 9:24:00 AM 7_ -Z/ FRibiTV / 7 //S---- Foundation Inspection Report Office No. (518)761-8256 Date Inspection,request received: Queensbury Building&Code Enforcement Arrive: ZC am/pmn ,/ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspectors Initials: NAME: `i7y- / l / PERMIT#: LOCATION: TU g �(/(�r' /� ) INSPECT ON: i 7-- P & TYPE OF STRUC Comments Y/, N N/A Footings Piers Monolithic Slab Reinforcement in Place // / `� V'/ The contractor is responsible for f providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Repart.doc Last printed 12/20/2005 9:24:00 AM