Loading...
2006-699 TOWN OFQ UEENSBURY Fora742 Ba ad Queensbury,Ro ,Quee bury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060699 Date Issued: Friday, October 05, 2007 This is to certify that work requested to be done as shown by Permit Number P20060699 has been completed. Location: 308 GLEN LAKE Rd Tax Map Number. 523400-289-009-0001-085-000-0000 Owner. NANCY J CHOPPA Applicant: NANCY J CHOPPA This structure may be occupied as a: Garage - 2 Cars Detached By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the • property owner of the responsibility for compliance with Site Plan, ' Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. 1 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 FAT Community Development- Building &Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060699 Application Number. A20060699 Tax Map No: 523400-289-009-0001-085-000-0000 Permission is hereby granted to: NANCY J CHOPPA For property located at: 308 GLEN LAKE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: NANCY J CHOPPA 308 GLEN LAKE Rd Garage-2 Cars Detached $5,000.00 LAKE GEORGE, NY 12845-0000 Total Value $5,000.00 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2006-699 672 SQ FT DETACHED 2 CAR GARAGE $67.20 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, October 24, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Qu_eensb1uy; es 'a October 24, 2006 SIGNED BY ;'"` for the Town of Queensbury. Director of Building&Code Enforcement • OFFICE USE ONLY ', 1. `x -1 — F5 r . ; • TAX MAP NO• . Z PERMIT NO. ( / 9 • ; ,r , FEE PAID 7 - BLDG. &CODES APPROVAL = ' • • -, J ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. J rl;G OWNER: I -1 IL lli , i ,t;7K'CP/V INSTALLER/BUILDER: tEI--t= leoft v\u-rot-mss Q1 Z- O E "rt /,[ / 6;C ADDRESS: 3GL. lAte-e ' M ADDRESS: 2?6 L S,t.c. LZ Ati)C-- cw-E-Prb,vt i"t FIFActi, F-L. 3--s•445 • PHONE NOS. 76/3 3 53 cJ r'L'i' -144-4&4 PHONE NOS. LOCATION OF PROPERTY: ..5A•ME- f FUJI✓ SUBDIVISION NAME: Iii-F LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ,YEC-- '>i i E fLAtJ C� ESTIMATED COST OF CONSTRUCTION: $ 50c C' J ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES,PLEASE LIST: ro,zAci - eS ak-J31� t Lo l Lo j� 26''t L— \ CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: Ier ND PROPOSED I l PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT I SQ.FT. SQ.FT. SQ.FT. I ( FT.&IN. OPEN PORCH I DECK 3 SEASON,COVERED OR ENCLOSED PORCH' BOATHOUSE j I i BOATHOUSE WITH SUNDECK DOCK I SHED 1-€.4r--T- POLE BARN 21 la DETACHED GARAGE(NO.OF CARS: ) /_ 2 / 7 2. I OTHER ACCESSORY STRUCTURE: ._ i i t *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new . Construction. QUESTIONS? CALL 761-8256 OR EMAIL ._,_' codes@queensbury.net i I haa read and agree to t.,e above. VISIT OUR WEBSITE FOR MORE INFORMATION Si nes C www.queensbury.net g _s/I�ri. Dated: ' ''`: ' Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm D art `\Cam/pm Date Inspection request received: Inspector's Initials: - NAME: PERMIT#: LOCATION: 11ir� 2 �� DATE: TYPE OF STRUCTU'l: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched A)) 4Y Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc ir� IPA— rte...=-_=7si�/ mow+ Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/p�}1 Depart:�pm Date Inspection request received: Inspector's Initials: NAME: � PERMIT#: 2PF LOCATION: IZO ,t,. a ,e_ DATE: TYPE OF STRUCT Com ents Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete YR-0�Platform at all exterior doors LY1 Z) Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches Guard at deck,porch 36 inches or more fWat, t Handrail Termination a Newell Yos or Wall _ Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade k- - Z Interior privacy/trim/doors/main entrance 36 inches _ Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom arca: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible arca Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq. ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''h"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent L:1Building&Codes Forms\Building&Codes\Inspcction Forms\Residential Final Inspection Form_revised_100405.doc 44. Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/am epart( --2r5n/pm 742 Bay Road,Queensbury,NY 12804 Inspe;tor's Initials:C_ NAME: i1 _ .4`.. PERMIT#: 9 LOCATION: /.0111'. / INSPECT ON: TYPE OF STRUCTURE: O' Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. I! Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/s(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses o is e or less on center I Ice and water shi- 24 inches from wall . - .... a ion 1, 2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. _ Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade - ID v rs . Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: er; /0 am/pm . epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspectors Initials: NAME: Com PERMIT#: Q t77 LOCATION: 39 G �fre_. g/ INSPECT ON: TYPE OF STRUCTURE: Comments N N/A Footings Piers •�• icSlab Reinforcement i ' ace The co or is responsible for . oviding protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM