2006-706 � 111% TOWN OF QUEENSBURY
742 Baty Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20060706 Date Issued: Tuesday, August 26, 2008
This is to certify that work requested to be done as shown by Permit Number P20060706
has been completed.
Location: 12 TREASURES P1
Tax Map Number: 523400-302-008-0001-091-000-0000
Owner: JOYCE A EDWARDS
Applicant: AMEDORE GROUP, INC.
This structure may be occupied as a:
Garage - 1 Car Attached By Order of Town Board
Townhouse TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property (1 ,./P4
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
Ale` TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20060706 Application Number. A20060706
Tax Map No: 523400-302-008-0001-015-000-0000
Permission is hereby granted to: AMEDORE HOMES
For property located at: 314 BAY Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JAMES & GLADYS BROWER TRU
121 POTTER Rd Garage- 1 Car Attached
GANSEVOORT,NY 12831-1011 Townhouse $17,500.00
Total Value $17,500.00
Contractor or Builder's Name/ Address Electrical Inspection Agency
Plans &Specifications
2006-706
BUILDING 11
12 TREASURES PLACE (DOWN,LEFT)
1234 SQ FT CONDO WITH ATTACHED 260 SQ FT 1 CAR GARAGE
$198.76 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, September 20, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of Qu nsb W gI`n j day, September 20, 2006
SIGNED BY for the Town of Queensbury.
Director of Building&Code E orcement
:. - 1
L-11.WI.tLe /
I
OFFICE USE ONLY ,...S""""
' ,....................
TAX MAP NO. 02 •
- PERMIT NO. `'�
FEES: PE- IT nafot i Date
R REATION_ ;
70 � �F T----ENGINEERING � ; Shinn
.... vy.01.‘7 6d,�A/;� ... .f}.-"/1 (If applicable)
(�iC.. � UNJTS alC ---,.�...........
PRINCIPAL STR - .-
A.T�PLIC STRUCTURE:
------
ATION FOR ZONING APPROVAL & BUILDING
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. PPLICATIOPERMIT
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. N IS SUBJECT TO
APPLICANT/BUILDER: to ,}0 MO/IA OWNER:
m�
ADDRESS: i o r u e—/16,ri - / / /Z Z o ADDRESS: SCF.yyl
PHONE NO
b ~zt2z(:2PHONE NOS,
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:
...14r
ii ri� PHONE:
_&L-aA
LOCATION OF PROPERTY: 3 `y 01 /2 .) c: .
- t e....._,
SUBDIVISION NAME: A ikii ` _40, 01 • Ida 1 1A
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
PROJECAPPLY TO YOUR z0 0
Oct
E W 0 � o , cOn waw
a' t r. g
lyilij/j SINGLE FAMILY ,
ieJ
12 it
»Z ��
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS_
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHE
GARAGI1 2,3) 260
Zb.( ''
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST:-L.L
• FUEL TYPE:
HEAT TYPE: *HOW MANY FIREPLACE($).c j'ia4 AND/OR WOODSTOVE
ZONING CATEGORY: S(S):__i
ARE THERE WETLANDS ON THIS SITE?___y_e_S__________
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: Cb/1/4)t
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
B 3-LGL 1 1-05
+ " Town of Queensbury• Bay Development elopment ce • 742
• Office y Road, Q.ueensburii. NY 7 u.n.r
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? N0
ARE THERE EASEMENTS ON PROPERTY? d 40
•
ramir
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior toissuances of a certificate of occupancy.
I have read and - =_ o..the abo B.
Signed
Director of Bu'Idin des;..•761-825 (for questions regarding.Building Permits, construction
codes or septic systems
Zoning Administrator 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed ac
Applicant to erect or alter the buildingtion described
herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
u�,
BU DI / ODES AP-- •VAL
ZONING APPROVAL
DATE
DATE
QUESTIONS? CALL 761.8286 OR'EMA!L
COtie S( pl]HBfQbui i
VISIT OUR WEBSITE FOR MORE INFORMATION
VY1tiM!gitg@n8bu:
—�— �._. �r� het
TOMf Queensbury• Community Development Office .
,� 742 Bay Road, Queensbury, NY 22804
SC21-idr_i 11 o6-906 iz
7..Al2 4 - -/5- OFFICE USE ONLY ,
TAX MAP NO. ' :m:, -..-4 ,3-0,7
PERMIT NO. PERMIT FEE ; P,.,, „ ; 'F. y
APPROVALS: ZONING ' , "8��"
TOWN CLERK ;
APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT:
A PERMIT MUST BE OBTAINED BEFORE WORK BEI ttrc H �.�.� I
INSTALLER: A ,_ ..\
,
ADDRESS: 1(40 0 V e 2- - Y W e.
ADDRESS:
AiA)
PHONE NOS, S-i r6 5-1.,- / 0 / 0 PHONE NOS.
LOCATION OF INSTALLATION: Li 1Q.dC ,
YEAR BUILT
I . ' COMPUTAT
I _ RESIDENCE INFORMATION:
1 BEDROOMS
1 X I ION= TOTAL DAILY FLOW
1980 or older 1 I X I 150 gallon per bedroom 1 = GARBAGE GRINDER
INSTALLED?
• 1981 -1991 1 X I 130 gallon per bedroom
SPA OR HOT TUB
1992-present J I X l 110 gallon per bedroom I = , INSTALLED?
t
PARCEL INFORMATION:
✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE
✓ SOIL NATURE: SAND LOAM CLAY OTHER
✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT
WHAT DEPTH?
✓ DOMESTIC WATER SUPLY: MUNICIPAL ✓ WELL
•
(IF WELL: WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. )
✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE
COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT)
PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by
a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250
gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub.
✓ SEPTIC TANK: GALLON (MIN. SIZE IS 1,000 GAL) TILE FIELD: EACH TRENCH FT.
✓ TOTAL SYSTEM LENGTH: FT. SEEPAGE PIT(S): HOW MANY?
✓ SIZE OF EACH FT. X FT.
✓ SIZE OF STONE TO BE USED: tt /DEPTH OR THICKNESS FT.
✓ BED SYSTEM SIZE: X
✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE
✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH
✓ GALLONS./TOTAL CAPACITY: GAL.
INOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN I'
APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. 1
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any
permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or
failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and
agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL
Queensbury Sanitary Sewage Disposal Ordinance. codes@queensburv.net
/ VISIT OUR WEBSITE FOR MORE INFORMATION
/ www.queensburv.net
Signature of Person Responsible Date
=;3;; Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
-
I ) /r_cb ,
A
QueensburyBuildin & Code Enforcement - Resi enalFinal Inspection
Office No. (518) 761-8256 Arrive: am/pm Depart:2260 am/pm
Date Inspection request received: Inspector's Initials:
NAME: / 4 �, e-- . PERMIT#: " 2
'lam
LOCATION: /? .S;;t-C� r 7-)! DATE: ACM
TYPE OF STRUCTURE:
Comments:
Yes/No WA
4' Building Number Address visible from road V/
Chimney Height/`B'Vent/Direct Vent Location /f
Fresh Air Intake %.
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors V /
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade N7
Guard at stairwell at 34 inches or more ✓/
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall 7
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet V,/
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy!trim I doors I main entrance 36 inches //
Bathroom/Kitchen watertight N/
Safety glazing/Wi in stairwells safety 'ng
Interior Smokeors/Carbon noxi Det ors
Every level: ������////// E Bedr m:
Outside every bedroo rea:
Inter Connected: T Battery backup: • r—
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area dLS�"N`Z-k_ tO
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site ./V"..:/'
Oil Furnace shut-off at entrance to f mace area ��
Fumace/Hot Water Heater operating
r. rTh_Pa2sa_
Low water shut-offiboiler CY �/ ?�
Relief Valve(s)installed I Heat Trap/Water Temp 110 /�
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
•J h A , ` '
c fit V't'\-L*4+v
Basement stairs closed rise>4 inches / v'`,�� ` --'
Garage Floor Pitched
Garage fireproofing/'/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
.1/
/„.,
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker d
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C I 0[Temporary/Permanent] tilf
L:1Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm Depart4 r am/pm
Date Inspection request received: Inspector's Initials:- 4 :L`_n
NAME: � 7` PERMIT#: r •
LOCATION: �L..,G�?2 `"��` 1 DATE: Mar
41. �
TYPE OF STRUCT RE: t r"'TL
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110 i
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding �\
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Jnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008
•
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury, NY 12804
Date received:
NAME: 41Ae-e‘
LOCATION: /Z (t?"_6:Z5V/T:c
PERMIT#: 7-0(‘
Final Survey Plot Plan
Approved Denied
The attached final
survey has been
received by the
Dept. of
Community
Development.
Upon review the
survey has be, .
1
Craig :4, Zoning Administrator
Notes:
L:1SueHemingway\Building.Codes.Inspection.FORMS\Final Survey
Zoning Administrator.doc
9-il
iNcahes(-JaA// z-_://3/o7
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins 1 ecion re• -: ei -d:
Queensbury Building&Code Enforcement Arrive: , Tofu Pep. : n>/pir}/
742 Bay Road, Queensbury,NY 12804 Inspector s Initi.
/.
NAME: ,_ : r jam' PERMIT#:
4111 go,
LOCATION: 1 l f f / INSPECT ON: _Mir
TYPE OF STRUCT
Y N N/A
Framing COMMENTS
is Access 22"x 30"minimum ^17c-7
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams v
Exterior sheeting nailed properly `J
12"O.C. � J�
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
(,..eoP .),
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request rfru--iv-•
Queensbury Building & Code Enforcement Arrive: ,;:01) ami. ,P-part. 9)4' '& am/
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: /
NAME: AMEf PE N0IME1 ( -FL)EC 3ERR) PER r #: dg? - (0(D
LOCATION: 1(> 1Z TR.F it)RE_ L.AcJ INSPECT ON: 2_-9—nom
TYPE OF STRUCTURE:
2,- \ •16\6----__r_Dr
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction ,
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
n Air / Head
/�f� 50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check /
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
v�� ombustion Air Supply for Furnace
uct work sealed properly / No duct tape j `
P 1PIPP5TpPit06 V1 I
COMMENTS:
1c T-� — A-vTu k cc- ��,_,- \L' 16 u.36c-v- ci , (-4 04T 7z_t a)1
k•- EE\--)b --\--0 �3 __ MOP . u\v„v___-
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
2-7/7/o7 .
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request - -'• -d:
Queensbury Building & Code Enforcement Arrive: s" keine 4,P-p. • : = 1 •m
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: .G
NAME: /'Ci PERT IIT #: <�f 7(./(U
LOCATION: 1 INSPECT ON: 2- —O
TYPE OF STRUCTUE:
\
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
/--50-PS':L for 15 minutes
Insulationi/ Residential Check/ Commercial Check _ • t.)C � TO
-------ProOrVent, Attic Vent T���T�� v p
Duct / Hot Water Piping Insulation v1A
�,A
If required unheated spaces 11vlAo� .
Combustion Air Supply for Furnace
Duct work sealed properly 1 No duct tape
COMMENTS:
OTYT f\ ?vim
•
V. _C_A3ka-- = o°\-‘71j\
L:\Pam Whiting\Building&Codes\Inspection Forrns\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Rough Plumbing I Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection regi.,iestsreqeiviecks
Queensbury Building & Code Enforcement Arrive: 1\: L>h rr� fi ,Depart: ' 1 -1 �(am/. m
742 Bay Road, Queensbury, NY 12804 Inspector's Initials.
NAME:_ E ERMIT #: i t 7L
LOCATION: Clv1c_ ` F vt TcLEt-1 k►- cL-INSPECT ON: Z —
TYPE OF STRUCTURE: '. ; �i, .)t�
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
s,.
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
AiAJyT
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reques (:)
(:) ?
Queensbury Building & Code Enforcement Arrive: 2_I F) a •40, am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initial. a
NAME: A-rY -c-1> �,�� )�c, .�e + PER /#: ()(, �7U�
LOCATION: 3 / ANSP' CT ON: 7/o-1
TYPE OF STRUCTURE:
(A l ( I 5 ( )---
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check _ cNECV_ cJ
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation 3' 30 .M , IA7:-
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request receiver:
Queensbury Building & Code Enforcement Arrive: . 3 n9 D0 am prt:
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:& 1<
7
NAME: /.\ tME_C)NRF 1-\o 4 -5 c '.-11 G j PERMIT #: 06-71 (0
LOCATION: P,t G 1 t (001 aPCEINSPECT ON: Z-1 -
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly f No duct tape
Clot »,J rP��ZS wzyk T cx) vsl,DT 1--\tE-\ 4\k
COMMENTS: L1:vtiT` INVW-DEcO
k hA .3 L \-7 tcT. �a-� C c� it �� f i``-moi -17
SLI:))UY V. t cu..) fr t h 5 l�L ,? t�C off Tei?
\ p c2c)0 14
61,-Ai,� r 12_ v._. ,V_
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing insulation Report.revised Nov 17 2003.doc Revised February 15,2005
l
Framing / Firestopping Inspection Report C`
Office No. (518) 761-8256 Date Ins section re,_'- ved•
Queensbury Building&Code Enforcement Arrive: ► * D- rt: amam
742 Bay Road, Queensbury,NY 12804 Inspector's Initia •
qlcLc)J-NAME: 4011"
PERMIT#: OC.0 Co
LOCATION: l?i4AG .1 Ci4 p(i ) INSPECT ON: _
OF STRUCT Ot,� ,
r N /N/A lat/oit ` )1 �OMMEN
Framing �( [ ci4tTS
Attic Access 22"x 30"minimum ci-j476)
Jack Studs/Headers ✓/
Bracing/Bridging ✓/'
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in. s\// 7- `'`� � ��—
Stairwells 36 in. or more r-
Headroom 6 ft. 8 in. 12-16 V\ , 1 o ti �� S)E2.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 ''A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
•
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Framing / Firestopping Inspection Report
Office No.(518)761-8256 Date Inspection re w - eive
Queensbury Building&Code Enforcement Arrive: 41:1 D-,.< •_ : ' am/,
742 Bay Road,Queensbury,NY 12804 Inspector's Ini :
/ � PERMIT#: (��� �
NAME: (�
LOCATION: �� " � f( _ INSPECT ON: --'5 t•—/-)7
TYPE OF STRUCTURE: /
Y N /A
Framing COMMENTS
Attic Ac - s 22"x 30"minimum
Jack Studs/Headers -' LI—
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly I
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
I
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in. (W)
5.7 sf above/below grade
5.0 s grade
-/O �Ls4V izo 10--
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection requ t r e • 7
Queensbury Building & Code Enforcement Arrive: a m art: �c 3 .dm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:(---- -
NAME: klrA Qo�t _ ops PERM #: 0‘.--- -7(6
1')if
LOCATION: d , /l ')" AkV'L�u'�
\QF - -, INSPECT ON: I -30-o-r
TYPE OF STRUCTURE
77
g Plumbing!! Y N N/A
��! Rou h Nail Plates ,
N---,Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum ✓
Cleanout ever 100 feet/ change of direction
Pressure Test j
Drain / Taff
Air / ead
5 P.S.I. o 10 above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check/ Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
- /DA-.
Framing / Firestopping Inspection Report
Office No.(518) 761-8256 Date In pection request r ivied: f L'7
Queensbury Building&Code Enforcement Arrive: ;�t an�/pm-' - •art: I /�a`nlpm�--'
742 Bay Road, Queensbury,NY 12804 Inspector's Initial
NAME: Al; �- PERIv1IT#:
()( - 7()
LOCATION: '" ilgraginaMICE C(e INSPECT ON: /®O "
TYPE OF STRUCTURE: A�
F ''% jam`►
Y N N/A COMMENTS
�Framm /
v
Attic Access 22"x 30" minimum r
Jack Studs/Headers
Bracing/Bridging QLEvA
Joist hangers
Jack Posts/Main Beams Lit\[ &
Exterior sheeting nailed properly
12"O.C.
Z\-/71-
Headroom 6 ft. 8 in.
Stairwells 36 in. or more /
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate 1A v•--) wLAT
1 %z(w) 16 gauge(8) 16D nails each side ,�j F.
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center z..21;/E y �J
Ice and water shield 24 inches from wall r /
Fire separation 1, 2, 3 hour 1 .
i, ,) ire wall 2, 3,4 hour
L
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X /
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms ".\//
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection r quest re�e .� d
Queensbury Building & Code Enforcement Arrive: \ ,vham/ J3i> pa :
742 Bay Road, Queensbury, NY 12804 Inspector's Initials--
NAME: l '1 - -C- PERM '#: O - 70 %
LOCATION: O ( I -te c�/Ccc INSPE ON: o
TYPE OF STRUCT RE:C •(_ l •-\t,,r'g 0C:4y-
--� Y 1- N N/A
ough Plum.' g / N. I Plates
._ ' Vents-in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5_P-.-S 1-.-or-1O-ft-move highest connection for 15 minutes
Pressure Test
eater Sit \i/
Air / Head
50 P.S.I for 15 minutes v'
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
S-/ ) /1-/I2SLYi-/ /z%/
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins•ection ret =ieceiv=•.
Queensbury Building&Code Enforcement Arrive: : _ WO! :ep. : 1 •m
742 Bay Road, Queensbury,NY 12804 Inspector's Initia s: ' •
9 —
/
( .
NAME: YerPERMIT#: iisVIIMINI
LOCATION: ( +,/ INSPECT ON: '
TYPE OF STRU TURD'
Z. I �� �\ o,�
r Y N N/A 4
Framing COMMENTS
ss 22"x 30"minimum / _,,------> e t p Y'lA OF 1,5
Jack Studs/Headers V - >
Bracing/Bridging �O Tb � kE v�a<<''z ��
Joist hangers /• n� Rt b�J oo Tt'il�5 To
Jack Posts/Main Beams ✓ F Long_-r-?._v �+..1, Ec-T-ta USA,"y
Exterior sheeting nailed properly f161-‘,_ Z its, �p �
12"O.C. / ►
Headroom 6 ft. 8 in. �/ % ' 1-A (�E�S OA U 11�(-� 0
Stairwells 36 in. or more a \ �l L N t ‘ .6
Headroom 6 ft. 8 in. J ) i\ SSV 5 `
Notches/Holes/Bearing Walls F � k-ys
{'DC-+\R‘Ivy L.O C.iRT l o X3
Metal Strapping for Notches Top Plate
I IA(w) 16 gauge(8) 16D nails each side ' w�;C' . 1 � �T RJ tom- Gy j�
Draft stopping 1,000 sq. ft. floor trusses 13 C LDt UN\Tv R�C01V.F To
Anchor Bolts 6 ft. or less on center V, F PmE -vbs vv
Ice and water shield 24 inches from wall PVC-C--LA
V.5 VER--.
ire separation 1,2, 3 hour /J I -�--\)'7S \
Fire wall 2,3,4 hour
I/ t-A- 6TRo�C7
- k �IL�-� ��C�ij 1 REq--0D _ 3
Penetration sealed
Qiil
i ti 123 �- E k<--\--k PJA,l�VKJ6
16 inch insulation in cavity min. LOCA7-101J
Garage Fire Separation2
House side 'A inch or 5/8 inch Type X — F1 FL.HCl- 1-12.0 55 ►AeitJ)6
Garage side 5/8 inch Type X
Ceiling/wall -_ Qti,ST3 i`: 1 (15-1-- Li'; )- OP
Windows Habitable Space/Bedrooms
(-)1\ L�V P i P oia- QRAQ i l• u3 ALL
24 in. (H)
20 in. (W)
5.7 sf above/below grade — V-,-c47 - F--05 .&3 //
M 1 X51b
f.�
5.0 sf grade j
VR OV t, 1�% .L, ;�
Flom- ' ' LtisG art ! \9 �,
Fl
Ccs gc a k� .
Ab Cc
>l� .7b-E- /2//x/06.
Framing/ Firestopping Inspection Report
Office No.(518) 761-8256 Date Ins ectio equ�ed:
Queensbury Building&Code Enforcement Arrive: , a ORM ep. .-. am/pm
742 Bay Road, Queensbury,NY 12804 Inspectors Initi. .• it
'7C6:2
NAME: [ ft; (3F y PERMIT#: -�► . .
LOCATION: f_t?, /)►`..- /1 INSPECT ON: Z I d
TYPE OF STRUCTURE:
Y N N/A
Framing COMMENTS
i
Attic Access 22"x 30"minimum
Jack Studs/Headers
DT—
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall �—
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour �—
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms 1
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:AV 10-6 am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: e"t.
NAME: 7 PERMIT#: i11111
LOCATION: / t fl,-& Fu t t INSPECT ON: •
TYPE OF STRUCTURE: '?
Y N N/A COMMENTS
Framing
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall <= Z�
1, 2
Fire separation , 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
5- -10 ----F5a5bAy /2-h-F-__
Framing/ Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart ``fJ)amJpm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials
v
*-7-4:-/67
NAME: /Eor PERMIT#:
LOCATION: 5i,Q /f INSPECT ON:
TYPE OF STRUCTURE: LI
_ Y N N/A COMMENTS
Framing
Attic Access 22"x 30"minimum ReeItEc'
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft.floor trusses
i
crr
chor=Bvl son center i
Ice and water shield inches from wall (�c 't - �'` o--
Fire separation 1, 2,3 hour ' PrtA4--'kl- i'LA)./k —
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm art:2)p am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
7C .
NAME: � � L� PERMIT if:
LOCATION: '7i1v � INSPECT ON:
TYPE OF STRUCTUR'E:
Y N N/A COMMENTS
Framing
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls F.0
Metal Strapping for Notches Top Plate
1 ''A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center ���ptA.-01,1- 1.,c2
Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed ti,
16 inch insulation in cavity min.
Garage Fire Separation
House side 'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
/ /Z MCA) e/ /z /// /06
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:ID cm/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:A tU--"?
7)6
NAME: N 3 C�;PN4L_ PERMIT#: C7 - C
LOCATION: ' � / ? INSPECT ON:
TYPE OF STRUCTURE: .*?
Y nT N/A COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. `a �-�'�� X17;1:4"-- -4--
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in. ^ '
Notches/Holes/Bearing Walls \N. �- w t/ c —Metal Strapping for Notches Top Plate
1 'h(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
An $o` or less on center /f
Ice and water shield inches from wall
Fire separation 1,2, 3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed I
16 inch insulation in cavity min. f
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms '
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
7/ 7-06..-_- (0/2��
Foundation Inspection Report
Office No. (518)761-8256 Date Inspectionest r,c •.
Queensbury Building&Code Enforcement Arrive: .)- tri Depart: 5 m/
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initia s:
NAME: a' i p .0r,#: ,&6". -- 706
LOCATION: !( 31N )3i1 ROAD 1 SPECT ON: I Q — '2_4—r°
TYPE OF STR CTUI
��-\-- \Comments
Z
Y N N/A
\ Footings k*R1.j3J C`-1 k E
iers '
)(Monolithic Slab - /
Reinforcement in Place �(, I
The contractor is responsible for �/
providing protection from freezing
for 48 hours following the placement
of the concrete.
• or this ,• -,..se on site.
-oap i:on i,,F 1,,,
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
it PVC/Cast/Copper
7
-Foundation Insulation terio)Exterior
R- 1C '�
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection q - ed:
7
Queensbury Building &Code Enforcement Arrive: , ,l� ej`• 0,
742 Bay Rd., Queensbury, NY 12804 Inspector's mitt• ,�
NAME: P�,��,,J R —
LOCATION: T��� `tEkK1�ANN n `A / SPECT ON: C9 --O —O
TYPE OF STRUCTURE:
Comments
Y I N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place D o
Foundation Dampproofing
Foundation/Waterproofing (er-G
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
•
Backfill Approval
or
u ing Under Slab
PVC/ st/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
I.:1SueHemingway\Building.C:odes,Inspcction.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No.(518)761-8256 Date Ins r ection r-.�: :
Queensbury Building&Code Enforcement Arrive: -4, r• e w Depart: 1-j()�r
742 Bay Rd.,Queensbury,NY 12804 Inspectors Initia s:
NAME: >�r�t3� � �i�� 1� l 1 T#:
LOCATION: 31 4 p70c, ' SPECT ON: 11) -- t 3—OCD
TYPE OF STRUCTURE:
,fsu \\ Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. ficelj `'tFoundation/Wallpour C-KT\
Reinforcement in Place ✓
Foundation Dampproofing
Foundation/Waterproofing
• Type of Dampproofmg/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
f .
L:1SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
/0 — i? . Ivy /0//0/C) .
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection - : : e. ed
Queensbury Building&Code Enforcement Arrive: , !y. . - Depart:
742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini
Tor,t),
NAME: ,err 1),P4/11T#: O!
LOCATION: y R r?i r- /,3 ili 7INSPECT ON:
TYPE OF STRUCTURE:
Comments
0
Y /A
Footings41._
Piers � �
Monolithic Slab ---V---'‘' . �;\\O
Reinforcement in Place
The contractor is responsible for �V--cp b :3. q\:L�L
providing protection from freezing
for 48 hours following the placementD
of the concrete. ���� �!'� ..
Materials for this purpose on site. 1L
Foundation/Wallpour € p V... �5,ti� :)
Reinforcement in Place ,/
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing 1
6 mil poly for wet areas under slab /
Backfill Approval
Plumbing Under Slab
v ,
Foundation Insulati.: Interior •rior
�`
- t`A
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
.77-Jubk1
Foundation Inspection Report
Office No. (518)761-8256 Date Inspecti n request received:
Queensbury Building&Code Enforcement Arrive: ;Q' am/p Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspec is itials:
NAME: L PERMIT#: �� .
LOCATION: ;1/4.4/ vc INSPECT ON: y „ d Cfl
TYPE OF STRUCTURE: /
814d- // Comments
Y N N/A do Pea G DGPJ /D'�
outings nn
iers V / 7—
Monolithic
Monolithic Slab
Reinforcement in Place Z PdabU��� C�� • Lem
The contractor is responsible for
providing protection from freezing /1/4)6 co D� I ft)(-2 ,a84e•
for 48 hours following the placement _
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place Ptai/ 's/C
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM