2006-717 TOWN OF QUEENSBURY
woo
742 BayRoad, n 2 4-
Queensbury,NY 1 80 5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20060717 Date Issued: Thursday, July 05, 2007
This is to certify that work requested to be done as shown by Permit Number P20060717
has been completed.
Tax Map Number: 523400-302-008-0001-075-000-0000
Location: 52 TREASURES PI
Owner. AMEDORE HOMES
Applicant: AMEDORE HOMES
This structure may be occupied as a:
Garage - 1 Car Attached By Order of Town Board
Townhouse TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the ! ,
property owner of the responsibility for compliance with Site Plan, Director of Bu �:ilding&Code Enforcement
„i
-
Variance, ti
Variance, or other issues and conditions as a result of approvals by the r• rcement
.
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury;NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20060717 Application Number. A20060717
Tax Map No: 523400-302-008-0001-015-000-0000
Permission is hereby granted to: AMEDORE HOMES
For property located at: 314 BAY Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JAMES & GLADYS BROWER TRU
121 POTTER Rd Garage- 1 Car Attached
GANSEVOORT,NY 12831-1011 Townhouse $17,500.00
Total Value $17,500.00
Contractor or Builder's Name/ Address Electrical Inspection Agency
Plans &Specifications
2006-717
BUILDING 7
52 TREASURES PLACE (DOWN,LEFT)
1234 SQ FT CONDO WITH ATTACHED 260 SQ FT 1 CAR GARAGE
$198.76 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, September 25, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Towonsbu Mp da
, September 25, 2006
0f • for the Town of Queensbury
BY V Q ry
Director of Building:,. T;ruorcement
OFFICE US •••. `•
. -
E ONLY } e....................
6
Date
i TAX MAP NO. 0 ` 4 _ -- PERMIT NO, ';FEES: PE-1 11-.2282_6R REATION slort: ENGINEERING ;
t_ T fFy_4W 6Q-iP!I F6;ft4g- /4 c (f applicable)
---.... `
PRINCIPAL STRUCTURE: d ii Ar,.
APPLICATION FOR ZONING APPROVAL & BUILDING
A PERMIT MUST BE OBTAINED BEFORE BEGINNING PERMIT
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.PPLICATION IS SUBJECT TO
APPLICANT/BUILDER:ijilerjactjhbeeS
OWNER:
Same_
ADDRESS: ASO q ' r A 1 VC_
/111-rty ! /ZZO ADE7RESS: SC�j'_T 1PHONE NO
PHONE NOS,
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:
SHONE:
,. ....a• -2- 4
LOCATION OF PROPERTY; 3 L '• '
_ - ,) J P`ace___.•
SUBDIVISION NAME: A afigi
`' -rte 1 /I . I ill
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
Q
APPLYCPROO YOUR zz
I�CJtI�I 65 t g O t 1 W
SINGLE FAMILY a = °c
JeW TWO-FAMILY /7Z-A
MULTI-FAMILY
(NO.of UNITS`)
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHE
GARAGP1 2,3) 2
OTMER 60
Zb.�
IF COMMERCIAL OR INDUSTRIAL NAME OF BUSINESS;
ESTIMATED CONSTRUCTION COST:
.1.2.p&Z2______ FUEL TYPE:
HEAT TYPE: *HOW MANY FIREPLACE�aa; �
ticAND/OR WOODSTOVES(S):
ZONING CATEGORY: EE_ARE THERE WETLANDS ON THIS SITE?
____y_e_a___
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: r
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
7,� of B 3-LGL 11-05
"?^ " Queensbury. Community Development Office • 742 BayRoad,, Q.ueensburv. NY y9Ain't
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? - NO.
ARE THERE EASEMENTS ON PRORERTY1 f)'/ I i e t se pei --1 5
y
I acknowledge no construction actiyities.;shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statemedescription of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to ISSUa nce'of a certificate of occupancy.
I have read and agr a tothe above.
Signed
>tti.
Dir ector.of Buiidlncl.. des,•76,1-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator• 761-8218 (for questions regarding required permits, the permitrocess
application requirements or to schedule an appointment) p
Permission is hereby granted to the above
This application I proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said ; zoning Laws of the Town of Queensbury
:. Application:
•
/9 L
•
lad la
ODES APPRo I L ZONING APPROVAL
•
410
DAT:
DATE
........................................... .................
QUESTIONS? CALL T61.8256 OR EMAIL
4d sl aU ensbw . net
VISIT OUR WEBSITE FOR MORE INFORMATION
..�'°"'' TOM/
°� . . of Queensbury• Community Development Office . 742 Bay Road, Queensbury, NY 12804
OFFICE USE ONLY
302dS-� I — IS ` , , s�
TAX MAP NO. PERMIT NO. PERMIT FEE ': �-�; . ' '��
` + .�
rl`�
APPROVALS: ZONING TOWN CLERK 0 o- a C
AUG 2 9 2006
APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: JURY
_LI_
.NU CODE_
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECX TO REVIEW BEFORE ISSUANCE OF A VALID
PERMIT. n j / r t t K Yl, 15$.'<+4y Co t,CX(Sip,,v,./' >aw1...s
OWNER: A-1 vw Y2 d 0 k e bt ow,-5 / INSTALLER: A .., .„ s 1.
,
ADDRESS: ' DD t)-4451„, Awe_
a
ADDRESS:
0 Ill- .,1 1A-) `1 , /? 2. O 3 FILEPHONE NOS. S) 145-10-- / O1 0 nn PHONE NOS.
LOCATION OF INSTALLATION: 2A f2-6Q,
YEAR BUILT NOBEDRO.OFOMS RESIDENCE INFORMATION:
X I COMPUTATION= = TOTAL DAILY FLOW
1980 or older 1 GARBAGE GRINDER
X 150 gallon per bedroom =
I INSTALLED?
• 1981 -1991 t X f 130 gallon per bedroom I = SPA OR HOT TUB
1992-present X I 110 gallon per bedroom = k INSTALLED?
{
PARCEL INFORMATION:
✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE
✓ SOIL NATURE: SAND LOAM CLAY OTHER
✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT
WHAT DEPTH? /'
✓ DOMESTIC WATER SUPLY: MUNICIPAL ✓ WELL
(IF WELL: WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. )
✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE
COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT)
PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by
a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250
gallons tb the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub.
✓ SEPTIC TANK: GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH FT.
✓ TOTAL SYSTEM LENGTH: FT. SEEPAGE PIT(S): HOW MANY?
✓ SIZE OF EACH FT. X FT.
✓ SIZE OF STONE TO BE USED: # /DEPTH OR THICKNESS FT.
✓ BED SYSTEM SIZE: X
✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE
✓ HOLDING TANK SYSTEM: (If required) NO. OF TANKS: /SIZE OF EACH
✓ GALLONS./TOTAL CAPACITY: GAL.
1 NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN I'
`• APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. I
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any
permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or
failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and
agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL
Queensbury Sanitary Sewage Disposal Ordinance. codes@queensbury.net
tLe....„_. ' / / VISIT OUR WEBSITE FOR MORE INFORMATION
,;2- 1/-b www.queensburv.net
Signature of Person Responsible Date
=`54,j . Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
a s �
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received:
NAME:
LOCATION: ir—e0.50ireSTI,
PERMIT#: C)G7/7
Final Survey Plot Plan
Approved Denied
The attached final
survey has been
received by the
Dept. of
Community
Development.
Upon review the
survey h.s been:
Craig •rown, Zoning Administrator
Notes:
L:\SueHemingway\Building.Codes.Inspection.FORMSWinal Survey
Zoning Administrator.doc
MAP REFERENCE
MAP OF A SURVEY MADE FOR
NIGRO GOMPANIES
BY, VAN DUSEN + STEVES. LLC
DATED` APRIL 27. lqqq
LAST REVISEDF SEPTEMBER 23. lqqq
W r or�1-<.,
PROPERTY LINE
cliff
ly D u S
&
■y'�■
L + i S u r v e ors
169 Haviland Road Queensbury, New York 12804
Q y,
(518) 792-8474 New York lic. No. 50135
'UNAUTHORI7ED ALTERATION OR AmnoN m A SURVEY
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
VIOLATION OF TE EDU "TIO LAW SUB -DIVISION z OF TME
NEW YORK STATE EDUCATION LAW.'
'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY
MARKED WITH AN ORIGINAL CONSIDERED
Of THE LAND SURVEYORSSte-ves COPIES.* SEAL SHALL
BEPREIER E TO BE VALID ,RUECOPIES'
'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT
SURVEY
THIS SURVEY WAS PREPARED IN ACCORDANCE PATH 77NE
BY THE CODE OF PRACTICE FOR INiN SURVEYORS ADOPTED
BY THE NEW YORK STALE ASSOCIATION OF PROFESSIONAL
LAND SURVEYORS. SAID CER70CATIONS SHALL RUN ONLY
TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND
ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL
AGENCY AND LENDING INSTTRAnON LISTED HEREON, AND
TO THE ASSIGNEES OF THE LENDING INSTITUTION.'
Map of a Survey made for
AM E D o R E HOMES
Town of Queensbury, Warren County, New York
ti
Date, JULY 02, 2007
�+ �_
Scale 1'=20'
ti
SHEET 1 OF 1
a
AMED07ORE HOMES
DWG. NO. gg073-46.48.50.52
O
DATE
DESCRIPTION
a+
cliff
ly D u S
&
■y'�■
L + i S u r v e ors
169 Haviland Road Queensbury, New York 12804
Q y,
(518) 792-8474 New York lic. No. 50135
'UNAUTHORI7ED ALTERATION OR AmnoN m A SURVEY
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
VIOLATION OF TE EDU "TIO LAW SUB -DIVISION z OF TME
NEW YORK STATE EDUCATION LAW.'
'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY
MARKED WITH AN ORIGINAL CONSIDERED
Of THE LAND SURVEYORSSte-ves COPIES.* SEAL SHALL
BEPREIER E TO BE VALID ,RUECOPIES'
'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT
SURVEY
THIS SURVEY WAS PREPARED IN ACCORDANCE PATH 77NE
BY THE CODE OF PRACTICE FOR INiN SURVEYORS ADOPTED
BY THE NEW YORK STALE ASSOCIATION OF PROFESSIONAL
LAND SURVEYORS. SAID CER70CATIONS SHALL RUN ONLY
TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND
ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL
AGENCY AND LENDING INSTTRAnON LISTED HEREON, AND
TO THE ASSIGNEES OF THE LENDING INSTITUTION.'
Map of a Survey made for
AM E D o R E HOMES
Town of Queensbury, Warren County, New York
Date, JULY 02, 2007
�+ �_
Scale 1'=20'
SHEET 1 OF 1
AMED07ORE HOMES
DWG. NO. gg073-46.48.50.52
N0.
DATE
DESCRIPTION
/ ..— r3 MD :IF 72-/O-7--
Queensbury Building & Code Enforcement - R. side tia '' al Inspection
Office No. (518)761-8256 Arrive: 1 A\( .4 A. / '...art: z_(1) pm
Date Inspection request received: — Inspector's Initials w,,4
NAME: n/t' i 0/—'�_ PE' IT#: o(? 19-
LOCATION: , E i _ D TE: —7---o-7
TYPE OF STRUCT .•
Comments
114/ il N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location ITh
Fresh Air Intake3 inch Plumbing Vent through roof minimum 6 inchesRoof Complete/Exterior Finish Complete `
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade ✓/
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall /
Interior/Exterior Railings 34 inches to 38 inches ✓
Interior Handrails @a stairs 2 or more risers / 1
Grade away from foundation 6 inches with 10 feet ✓! /
6 inch clearance to sill plate ✓ - = w
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches #
Bathroom/Kitchen watertight
Safety glazing/Win w in stairwells safety glazing ��
Interior Smoke De etors:
Every level: Every Bedro m:
Outside every bedroom aha
Inter Connected: ,/ Battery backup:
Carbon Monoxide Detector /
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area /
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents ,
Bathroom Fans, if no window J
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Igi
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site WA
WIE
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler IN ,
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum
Basement stairs closed rise>4 inches _ A Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer _ Fr el 0 NU
Duct work Sealed properly 7 n,Off~t
Gas Logs in Sealed or Glass Enclosure -- _wS{si�f � rAFes'
Final Electrical 1
Final Survey Plot Plan , /,"
As Built Septic System Sew ept.Inspection Sticker .A�
0 Site Plan /Variance req e
lood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Fi.. nspection Form revised I00405.doc
rf .0/� o7
.
Rough Plumbing / Insula io Inspection Report
Office No. (518) 761-8256 Date Inspection request r- - ed:
Queensbury Building & Code Enforcement Arrive: Z"OO am we.. : L: 1.1 ami
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: �� tet. r, U" ; * PER IT #:
LOCATION: G .si9/C:S INSPECT ON: (S
TYPE OF STRUC(JfE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air Be-d
• • .f•.r. 15 minutes
Insulatio Residential Check Commercial Check
• ••- r ent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly] No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
70 - /2. . 770(Sciemi. ( s-7/.'FA's7
.
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection req - - iv-d:
Queensbury Building & Code Enforcement Arrive: i�.• • -part: - am/
742 Bay Road, Queensbury, NY 12804 Inspector's Initial.. -
If
NAME: 711. hare_ PERM " #:
LOCATION: 7 , �eozor�S INSPECT ON: P iiff
TYPE OF STRU RE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air - --d /
C /0 F�S.I flit. 15 minutes
Insulation Residential Check / Commercial Check V/
_ Pro•- ent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace / .
Duct work sealed properly 1 No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing/ Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins.ectio -'ue- r. ei ed:
Queensbury Building&Code Enforcement Arrive. '' ':;V�t i m e • : (;DC)
742 Bay Road, Queensbury,NY 12804 Inspector's Initials.
3 11��--- __\1
NAME: At4 ot-t Eb t'.!* PERMIT#: O(r —711
LOCATION: JP 'Jv F INSPECT ON: 5
TYPE OF STRUCTURE:
401 Y/ N N/A (.94
COMMENTS
Framing _J x 30"minimum y FL'-VC
Jack Studs/Headers Lt' � a
Bracing/Bridging NE?�T G Co Joist hangers °� `=✓�5b�R=TQ19
Jack Posts/Main Beams zk
(551(87
Exterior sheeting nailed properly Q— O O Zl j
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft. floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
ire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestoppin
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
/ riz,,,,,,,_
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins section re• - - -iv-i: J ,:-/ G7
Queensbury Building&Code Enforcement Arrive: : • is rD- 'art: Mr'2]� V:•�t'�
742 Bay Road, Queensbury,NY 12804 Inspector's Initia s: L/
NAME: Api-e I & e, PERMIT#: C' - 7/ 7
LOCATION: i3 1 AJ cf `7 1 S •-z %r-27-/St/7e f' INSPECT ON: —57y/O7
TYPE OF STRUCTURE: / ' ACe
kO;VVI---v
! irning
Y N N/A COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers / /
Bracing/Bridging > STP-cts)( i C.-07- \ ETA
Joist hangers C--c)a'�1 /,--
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in. /
Notches/Holes/Bearing Walls /
Metal Strapping for Notches Top Plate \( /
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses i
Anchor Bolts 6 ft. or less on center
_
Oa
Ice and water shield 24 inches from wall �� \� " ,' %/`�:-Ail ►�
Fire separation 1, 2, 3 hour
1 Fire wall 2, 3,4 hour
Ems® v.J'.c..l_ t3WT�t-EiJ ?%�rp,
/
Firestopping
J
Penetration sealed fr tV pct. tJE VCSIN5E,
16 inch insulation in cavity min. / lN. \VF_ wok-E17n
Garage Fire Separation
House side %z inch or 5/8 inch Type X
Garage side 5/8 inch Type X `
Ceiling/wall _,(e Ll O — V1INN1T7L__ LO ALL__
Windows Habitable Space/Bedrooms ✓//
24 in. (H) /✓ 13 ���) $J �- V
20 in. (W)
5.7 sf above/below grade 2)AQ \2-0 1v l
5.0 sf grade
0A- V AC3:v
/ '. —12-
t5 -"/ /6 ________
Framing/ Firestopping Inspection eport
Office No.(518) 761-8256 Date Inspection re• •- 1 ece•ied: _
Queensbury Building&Code Enforcement Arrive:._<',i • %' are e• : .) a •fppm
742 Bay Road, Queensbury,NY 12804 Inspector's Ini .
'� K2 _ PERMIT#:
NAME: Al _ j �.
LOCATION: i+ / r1. INSPECT ON: , — 7
401 .TYPE OF STRUCT /
-----) ,
Y N NIA
Framing COMMENTS
• cress 22"x 30"minimum ,/
/ ?._._.. . ,
Jack Studs/Headers ‘// Gam' �%
Bracing/Bridging , / C'
Joist hangers ✓/ Mc--- "...-=-- �w1V -J�' \.')��V2(
Jack Posts/Main Beams ✓ \ t- `2��+= C��jN �'�F_? ‘v
Exterior sheeting nailed properly J Y -OL�
12"O.C. /
Headroom 6 ft. 8 in. l/
Stairwells 36 in. or more J
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls /
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses ,----
V1-;:x--'V---c-Vv-)'7 ‘t•J LtJt;v (1-^,C.A\ 1
Anchor Bolts 6 ft. or less on center J
Ice and water shield 24 inches from wall
:,fire separation 1,2, 3 hour � —
/,,t)
._i' Fire wall 2, 3,4 hour
Firestopping
Y. I fr\po.., ` ;:>\.•)(.3:- (:____\-\i1 ->T1-_-_ 4
Penetration sealed
16 inch insulation in cavity min. i.._1 D C-t\�F
Garage Fire Separation
House side '/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H) � L V "TD \ l k
20 in. (W)
5.7 sf above/below grade / l )2 --2--1 V W
5.0 wade t j
6 /66-
5--h//07
Rough Plumbing / Insulati n Inspection Report
Office No. (518) 761-8256 Date Inspection request i) ee-
Queensbury Building & Code Enforcement Arrive: )-#5t? a - • - •art: 7:� am/0
742 Bay Road, Queensbury, NY 12804 Inspector's Initis, -.
NAME: /QrnLrr ER #:
LOCATION: tJJ - Up. :c-CD / INSPECT ON: (S-1
( 01
TYPE OF STRUCTUt :
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
isilTt r 15 minutes
Insulation Residential Check/ Commercial Check _ --} 6F Au_
- ent, Attic Vent
Duct / Hot Water Piping Insulation t•
If required unheated spaces CE_ k
Combustion Air Supply for Furnace •-1\
Duct work sealed properly / No duct tape t +.)6vt iot\f
COMMENTS:
kkb
— C__ 1 \F
C v_Ec_t-\.Q
MfzDtO i\` 1�1 D�-tJl
L:\Pam Whiting\Building&Codes\Inspection Fornns\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
F. --/() . 6-1/2//c3-7z
Rough Plumbing / Insulati n Inspection Report
Office No. (518) 761-8256 Date Inspection re_s uest rec-'ved:
Queensbury Building & Code Enforcement Arrive: I r. a • D : j I=CY)
742 Bay Road, Queensbury, NY 12804 Inspector`s Initials.
NAME:
Ax-rx Joer y PERMIT #:
LOCATION: )31o' ? (j cf$Z . INSPECT ON: .-- l-UT
TYPE OF STRUCTUREU
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above hii_ hest connection for 15 minutes
Pressure Test
Water Supply Piping
\ ' Air / Head
? S.I for minutes
Insulation / R- idential Check / Commercial Check
Pro.- - - , Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed roperly / No duct tape
COMMENT •
L:1Pam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
JeJ -/� •o
Framing/ Firestopping Inspection Report
Office No. (518) 761-8256 Date Insnecti n request, - -iv..:
Queensbury Building&Code Enforcement Arrive: a .art: MA lamp
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: _ /kW
NAME: 711111'
PERMIT#: -L-27/77
LOCATION: Jr'n k INSPECT ON:
TYPE OF STRUCTL rRF0 1?;41`7_�y� i
N N/A COMMENTS
Framing
2"x 301,minimum I W27
Jack Studs/Headers
Bracing/Bridging V710\f---t
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls 0770 1 2,6
Metal Strapping for Notches Top Plate
1 Y2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
e and water shield 24 inches from wall S\t2 �\ —
i • re separation 1, 2, 3 hour
. ire wall 2, 3 4 hour
\
-stoPAin.
Penetration sealed C L Q A n
16 inch insulation in cavity min.
Garage Separation
House side % incor 5/8 inch Type
X V C�
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins.ectio3jeques '-eiv-. 0-7
Queensbury Building&Code Enforcement Arrive: : . h..42„,11: D .. : I-- . e.
742 Bay Road,Queensbury,NY 12804 Inspector's Initi.' •.
4LeCiNAME: , e, PERMIT#: _/.—�
LOCATION:— , .1t ' INSPECT ON:
TYPE OF STRUCTURE: , I • 00
r 1.. 101_
2_ illijA1
Y N /A COMMENTS
Vramin�'
4
Attic Access 22"x 30" minimum
Jack Studs/Headers '
1 2J ',5 C3 1, 6 ty1\1751tJ6
/ � ,�
Bracing/Bridging / �/ 1J. 6� _
Joist hangers f
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls J
Metal Strapping for Notches Top Plate
1 'h(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses /
Anchor Bolts 6 ft. or less on center ,/
Ice and water shield 24 inches from wall0
yy
Firseparation 1, 2, 3 hour
ire wall 2, 3,4 hour / �NA 0.,V---NALL NAC F to
Firestopping \)Cvt-'•C3EQ
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall /
Windows Habitable Space/Bedrooms ✓/
24 in. (H) ✓
20 in.(W) /
5.7 sf above/below grade /
5.0 sf grade �J
1,4i Town of Queensbury Fire Marshal
A v 742 Bay Road
' � Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Gas Fireplace/Stove Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufactu
instructions or specifications is allowed.
Permit# 0(0 1 17 Schedule Inspection , -j- Time LeL,730 am (anytime Ins' • -
Name AM F E 4--10 v' Address (.._TQ 1\1,0K_ Vt-AC F Rough In ill al!
-TT)17-13‘
Appliance Manufacturer HAAT Model#
Direct Vent V/ Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A Comments
Floor Protection
Clearances to Combustibles (all sides) ✓
Firestop(s) Vertical Chase ✓ /
Wall Penetration ,/
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve �� ✓
Combustion Air ✓
Hearth Extension (if any)
Mantel
Height above f/p opening
Witness Operation
Tank Placement(if LP)
White-Building Dept. _ ,_�_ Yellow-Cosigner Pink-Fire Marshal
..4/11111ft, Town of Queensbury Fire Marshal
14#
742 Bay Road
0 Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Gas Fireplace/Stove Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufactu••- 's
instructions or specifications is allowed.
Permit#QIo_ I—I Schedule Inspection \5.--—7-87 Time pm anytime Ins+
Name (c-&a)r 1-4 o M 3 Address t.52- Tt (sba e- Rough In I ^nal_,_,
Appliance Manufacturer. I-k.A'r I.) Model#
/Factory
Direct Vent Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A Comments
Floor Protection
Clearances to Combustibles (all sides) ✓
Firestop(s) Vertical Chase
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Termination ✓
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve ✓
Combustion Air ✓
Hearth Extension (if any)
Mantel
Height above f/p opening
Witness Operation
Tank Placement(if LP)
White-Bediding Dept. Yellow-Costa ter Pink-Fire Marshal
-/D-tva
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request -reiv •: 5 D
Queensbury Building & Code Enforcement Arrive: ft 1.5 ..m • i%epart: .m,pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: NfAs-e-kce PERM #: 7/
LOCATION: 1771 ctil 7 < T rI4 PECT ON: S Alro7
TYPE OF STRUCTURE.
Y N N/A
Bough Plumbing / Nail Plates pE4-0Nctt3 Ui.1 F
Plumbing Vent/ Vents in Place 10 ,51-4 \ kz itkt�
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape _
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
„7, , f
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: / U7
Queensbury Building & Code Enforcement Arrive: am/pm Depart: 11. ft am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (I i►,,1 r” Alp
NAME: edn>r 1 e5 PERMIT #: 06 - 7/7
LOCATION: �).._ Yc eASus e 5 f k (_- INSPECT ON: ql/ Vo77
TYPE OF STRUCTURE: l/ _-�--\
( VN N/A , iNn. (-17 .,
ough Plumbing / Nail Plates 1
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air / Head--_ - -- ----.- -----_
5 P.. L.'.-or1.0_fL above highest connection for 15 inutes
Pressure Test `-',- _....----
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation / Residential Check/ Commercial Check _
Proper Vent, Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
/14au /^1t7 4// /6'
• • •
Framing / Firestopping Inspection Report
Office No.(518) 761-8256 Date:in `ti r es ec : -
Queensbury Building&Code Enforcement Arrive:���( p part.; arp/p1
742 Bay Road, Queensbury,NY 12804 Inspectors Initiate ,
NAME: 7v j r�/ PERMIT#: _ 7,
LOCATION: ! / INSPECT ON: /- AW
TYPE OF STRUCTURE: CY' f l
Y N N/A COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate �
1 'A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses /1 (, ( }I ;. J
Ancho _:.: . ess on center
Ice and water shield 24 nches from wall
- . '. , 2, 3hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
. LY/a°7
Framing / Firestopping Inspection Re 6t
Office No. (518) 761-8256 Date Ins•ectio• -•ue- - e" e..
Queensbury Building&Code Enforcement Arrive: di. ,.y•- vf( t h'art: 1,7_6pm
742 Bay Road, Queensbury,NY 12804 Inspector's Ini.', :
NAME: �/ F /vrA rf PERMIT#: � r
LOCATION: /,/ /� INSPECT ON:
TYPE OF STRUC URE:
Y N NIA COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
DOkl
Metal Strapping for Notches Top Plate
1 'h(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Air Wit a • or less on center
Ice and wa er shield 4 inches from wall
- • 'on 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Foundation Inspection Report
Office No. (518)761-8256 Date Inspectio- quest received:
Queensbury Building&Code Enforcement Arrive/ , am/pJ Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspo6tor's Initials: -
NAME: ' /U G Vi PERMIT#: OC:, - 7/-)
LOCATION: f INSPECT ON: /0/2:5/65/65 (,:p
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place .
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
P umbing Under Slab
PVC/Cast/Copper
Foundation Insulation me 'or Exterior
R- b)
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
/ 640/0 b/r/ /C/23/06
Foundation Inspection Report
Office No. (518)761-8256 Date Insp9Etio r quest received:
Queensbury Building&Code Enforcement Arrive:/V, am/p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: f PERMIT# •LOCATION: dUrhhe
7 _ _ . INSPECT ON: 0 /OW°CQ-
TYPE OF STRUCTUI :
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
.r opper ���
Foundation Insulation • •rior/Exterior -�''�`'4il
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
r /0 i3 4 .
Foundation Inspection Report
Office No. (518)761-8256 Date Ins.ection r-.'.. e :
Queensbury Building&Code Enforcement Arrive: •/rp 1-
- Depart: -
742 Bay Rd.,Queensbury,NY 12804 Inspector's Int i.
NAME: i'ry ' RMIT#: A/
�� ✓
LOCATION: . y �J,�°Ao I SPECT ON: Mir ,
TYPE OF STRUC
Comments
Y N N/A
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
/_
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing vv
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
3 -1-) UE--- - A)E5-7)/41'1
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection req c•wed:
Queensbury Building&Code Enforcement Arrive:Z; Depart: . • pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial aro!
NAME: , 41 RMIT#: (2Ll -- / F .
LOCATION: . f �„ 1 . 1 SPECT ON: (C) — `
TYPE OF STR CTURE: •
Comments
•
N N/A
�ootings
Piers -�°C2)
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc