2006-772 TOWN OF QUEENSBURY
IF4T 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20060772 Date Issued: Monday, March 26, 2012
This is to certify that work requested to be done as shown by Permit Number P20060772
has been completed.
Tax Map Number: 523400-309-009-0002-001-000-0000
Location: 200 LUZERNE Rd
Owner: HOMESTEAD VILLAGE L P
Applicant:
HOMESTEAD VILLAGE L P
This structure may be occupied as a:
Septic Alteration Commercial
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the „ks---
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
ea TOWN OF QUEENSBURY
Die 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20060772 Application Number. A20060772
Tax Map No: 523400-309-009-0002-001-000-0000
Permission is hereby granted to: HOMESTEAD VILLAGE L P
For property located at: 200 LUZERNE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: HOMESTEAD VILLAGE L P
4294 ROUTE 5 Septic Alteration Commercial
CALEDONIA, NY 14423 Total Value
Contractor or Builder's Name/ Address Electrical Inspection Agency
SANITARY SEWER
DAN DRELLOS
PO BOX 224 •
GLENS FALLS NY
Plans &Specifications
2006-772
LOT 106 ALPINE AVE SEPTIC ALTERATION
$35.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, October 20, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town(QJey9bu Fri , ctober 20, 2006
SIGNED BY C ✓�i., for the Town of Queensbury.
Director of Building&Code Enforcement
OFFICE USE ONLY
TAX MAP NO. PERMIT NO. a %�7PERMIT FEE ..1) OCT 1 9 2006
APPROVALS: ZONING '
TOWN CLERK ; -
APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT:
A PERMIT MU T BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT 0 REVIEW BEFORE ISSUANCE OF A VALID
PERMIT. /L./ /�
OWNER: �" J -) 1#Afr / I. n INSTALLER' i r'T0V/ �1Z /3014-4.—/-eft.il/Ce
y
/ ' //�� �p t
ADDRESS: IJ Li1Z ..e 2Ne (2.0 ADDRESS: i1 0 3cX 2--Z`r C �--
PHONE NOS�vftr—J 2 �2// PHONE NOS. / 7 4 0 el613
LOCATION OF INSTALLATION:/ 0 5O Reid/-( ,4ei
•YEAR BUILT I NO.OF 1 / RESIDENCE INFORMATION:
BEDROOMS X COMPUTATION= = TOTAL DAILY FLOW
GARBAGE GRINDER
1980 or older X ' 150 gallon per bedroom = INSTALLED?
1981 -1991 X I 130 gallon per bedroom I =
{ ? I SPA OR HOT TUB
1992-present I X I 110 gallon per bedroom = INSTALLED?
PARCEL INFORMATION: .ef� pl-f 7fD/ 9 ;scA„,.f
/ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE
✓ SOIL NATURE: SAND LOAM CLAY OTHER
✓ GROUNDWATER: AT WHAT DEPTH? BEDROCK/IMPERVIOUS MATERIAL: AT
WHAT DEPTH?
✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL
•
(IF WELL: WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. )
/ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE
COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT)
PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by
a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250
gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub.
✓ SEPTIC TANK:) ° ° GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH 6) FT.
✓ TOTAL SYSTEM LENGTH: (2— FT. SEEPAGE PIT(S): HOW MANY?
✓ SIZE OF EACH FT. X FT.
✓ SIZE OF STONE TO BE USED: # Z /DEPTH OR THICKNESS YZ FT.
✓ BED SYSTEM SIZE: X
✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE
✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH
✓ GALLONS. /TOTAL CAPACITY: GAL.
. .......................
i NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN !j
' APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. 11
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any
permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or
failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and
agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL
Qu sbury Sanitary .-""-.e Disposal Ordinance. codes C�'queensburv.net
i4VISIT OUR WEBSITE FOR MORE INFORMATIQN
/O l f a www.queensbury.net
ign ture of Person R •onsible Date
4+: ;•;'s .4,1`' Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
,
5` u L'- / f CV ,, ____
Septic Inspection Report
Office No. (518) 761-8256 Date Inspection r-.jest ,./,-iv:..:
Queensbury Building & Code Enforcement Arrive: \ 7-O am . ,; .:.art: 1 h a pr�
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: 0r r ANAME: // ivd&7J rr NO.: /.'(`�.r C
LOCATION: /66 Alfil _ ,_,z I PELT ON: -1 7—Cv-i
RECHECK:
Comments and/or diagram
Soil Type: Sand / Loam / Clay
Type of Water: Municipal / Well Water OC/O/r
Waterline separation distance ft.
Well separation distance ft. I(" _O—i 7
Other wells: ft. •
Well Casing Length 50' + / - Y N N/A
[150'to well required if NO]
Absorption Field: Total length ft.
Length of each trench _, ft.
Depth of trenches ft.
Size of Stone
Seepage Pits: Number
Size: x
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box
Distribution Box to Field/ Pit
Opening Sealed: Y T N
End Cap Y__ N
Inlet/Outlet Pipes & Baffles Y _ N
Manholes 12"or less below grade _Y— N
[provide extension collar if Yes] _Y N
Location / Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan Y— N
Engineer Report and As-Built —Y , . N
ETU Maintenance Contract Y_ N
provided _
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
System Use S atus:
Approved
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved
L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc
ENVIRONMENTAL DESIGN
PARTNERSHIP,LLP
D
March 23,2012 L Q
Queensbury Building & Code Enforcement towN OF
742 NY 12804 Roaday eUl Lp/NGC p�U
Queensbury,
s
Attn: John O'Brien
Re: Homestead Village Mobile Home Park
Lot 106 Alpine
Dear John:
To complete some missing file information I have researched our installation records for the
referenced Homestead Village property. The original design plan date was September 21,2006
and the installation was conducted on November 6,2007.
On November 6,2007 I visited above referenced Homestead Village Mobile Home Park lots.
The purpose of this visit was to observe the installation of the new septic system designed by
EDP dated September 21,2006.
Based on my review of the plans and observation of the installation it is my opinion that the
installation of the system is in compliance with the intent of the design plans.
Please contact me should you have any questions regarding this system.
Sincerely,
Dennis MacElroy, PE
900 Route 146, Clifton Park, New York 12065 phone(518)371-7621 -fax(518) 371-9540
Septic Inspection R- rig,
Office No. (518) 761-8256 Date Inspection - r: -.-ed:
Queensbury Building &Code Enforcement Arrive: •• b-part: am/pm
742 Bay Rd., Q nsbury, NY 12804 I s is Initia. , k
NAME: / flNO.: i# 7 `�4f •
LOCATION: /067 !1� /` lfSPECT ON:
RECHECK:
Calk
C ►raker'-'Ctek serr
Comments and or diagram
Soil Type: Sand/ Loam/ Clay
Type of Water: Municipal/ Well Water '- / /0 0 7'
Waterline separation distance ft.
Well separation distance ft.
Other wells: ft.
Well Casing Length 50' + /- Y N N/A
[150'to well required if NO] t
Absorption Field: Total length ., ft.
Length of each trench
Depth of trenches ft.
Size of Stone
Seepage Pits: Number
Size: x
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box
Distribution Box to Field/ Pit
Opening Sealed: Y T N
End Cap Y N
Inlet/Outlet Pipes&Baffles Y N
Manholes 12"or less below grade _Y—
[provide extension collar if Yesl __--Y
Location/ Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits ft.
-: •- - :-r Plot Plan Y
Engineer Report a'd As-Built Y N
--• - ance Contract _Y_ N
provided
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
System Use Stat :
Approved
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved
L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc
/ o—f 0—ra 1J446,7407.a. C.
Septic Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p Depart: (2210
am/pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:
NAME: e, .�.: .V ., PERMIT NO.: 0 `- .
M
LOCATION: ' • ap:,L `/% 7- - INSPECT ON: ! i fE
RECHECK:
Comments and/or diagram
Soil Type: (and=it• Clay
Type of Water: • • ic y/ Well Water
Waterline separation distance _ft.
Well separation distance ft.
Other wells: ft.
Absorption Field: Total length #_____t:Length of each trench
Depth of trenches Cn ft.
Size of Stone
Seepage Pits: Number ��
Size: x
Stone Size:
Piping 4ze Type
Building to tank k_, n2 7c
Tank to Distribution Box rZ__-
Distribution Box to Field/ Pit A,, .bT`15c-
Opening Sealed: Y/ N/ Partial
End Cap C
Inlet/Out(et Pipes &BafflesT Y—N
C-1 `--�
Location/ Separations
_Foundation to tank ft. ' - `
Foundation to absorption ft.
Separation of Pits ft• / �
Conforms as per Plot Plan N (n
Engineer Report and As-Built _Y N
Location of System on Property:
Front Rear Left Side Right Side
Middle Front Middle Rear
__
S tem U s:
t • ..r. -:
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved
Last revised 021006
Last revised 1/6/05
k
INSPECTION REQUIREMENTS:
ENGINEER OF RECORD TO INSPECT TRENCHES PRIOR TO BACKFILLING.
LOT 107 LOT 108
EXIS77NG EX -
MOBILE BLDC.
Ek15PNG HOME
MOBKE WOOD S
HOME
W O O D S
EX.
BtOG.
EXIS77NG SEP77C TANK
(TO REMAIN)
PROPOSED 4" PVC SDR -35
(GASKETED BELL) AT 1% MIN.
EXIS77NO SANITARY LEACH W p p O 5
P7ELD SERMING LOT 106 EXIS77NG SEP77C TANK
TO BE ABANDONED) (TO REMAIN)
SOILBORING-T"
,.._.�._._. PERC TEST
I
PROPOSED,DISTRIBUTION BOX #:
F_ } f ! ( DETAIL- SHEET 2)
I O I I I I 1 1 3 BEDROOM-UNIT
a i �
o
EXISMO SANITARY LEACH
RELO SERVICING LOT 105
(TO BE ABANDONED)
'UVJ �7 1 1
WOODS I l
I I I i I l i i i i
I I I I I I I I I
I I I 11i 1i �i
L i m i l l
(n
6' LOT 105
PROPOSED ABSORPTION FIELD
4-LINES AT 63 FT. EACH TO
LOT 10 .
- SERVICE BOTHLOTS 105 & 106
.:';.;.(SEE DETAIL - SHEET 2)
}+ Q!, ` PARKING
9MW\
AREA
WOOpS
BUILDING &
REVIEW[-D 8}'_.._._. _ _
ALPINE AVENUE
N OTE:
MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION.
WHERE TRENCH SHIELD IS USED
WITH THE APPROVAL OF THE
ENGINEER, SHEETED TRENCH
PAYMENT LIMITS WILL APPLY.
ALL BACKFILL MATERIAL TO BE
PLACED IN 8" LIFTS AND
BE COMPACTED TO 95% STANDARD
PROCTOR (ASTM D698).
DEBRIS, FROZEN MATERIAL, LARGE -
CLODS OR STONES, ORGANIC
MATTER, OR OTHER UNSUITABLE
MATERIALS SHALL NOT BE
USED AS BACKFILL.
SELECTED GRANULAR FILL
PLACED IN 6" LIFTS AND
MECHANICALLY TAMPED OR
A.O.B.E. SEE NOTES 1&2.
CRUSHED STONE OR SELECT
GRANULAR MATERIAL AS ORDERED
BY ENGINEER (MECHANICALLY
TAMPED) OR A.O.B.E. SEE NOTE 2..
FOR UNSTABLE TRENCH BOTTOM USE
ADDITIONAL DEPTH OF STONE AS
NECESSARY TO PROVIDE A FIRM
FOUNDATION.
SELECTED GRANULAR FILL TO
BE PLACED UNDER PAVEMENT
1 1
TRENCH SLOPES ARE GIVEN FOR
MAX. PAYMENT LIMITS ONLY FOR
3 PEN CUT AND ARE NOT INTENDED 3'
0 REPRESENT STABLE SLOPES
UNDER FIELD CONDITIONS.
NOTES:
1) NATIVE EXCAVATED GRANULAR MATERIAL
MAY BE USED IF APPROVED BY THE
ENGINEER.
AVEMENT OR
RIGINAL GROUND
-:I A.O.B.E. = AS ORDERED BY ENGINEER
NOTE: CONTRACTORS MUST COMPLY WITH ALL
LOCAL, STATE, & FEDERAL SAFETY REGULATIONS.
(OSHA & N.Y.S. D.O.T.)
_NOT INTENDED TO REPRESENT
A SAFE SLOPE
6" WIDE GREEN PLASTIC LOCATOR TAPE,
MARKED "CAUTION SEWER BELOW"
_TRACER WIRE #8 THNN STRANDED
COPPER OR STAINLESS STEEL
2" THICK RIGID POLYSTYRENE INSULATION
LOCATIONS WITH LESS THAN 4' COVER).
EXTEND TO MIN. 4' BELOW GRADE.
6" MIN. FOR PIPE 12" DIA. AND SMALLER
r' `+ 12" MIN. FOR PIPE 14" DIA. AND LARGER
WHERE A WATER TABLE CONDITION EXISTS
STONE BEDDING SHALL BE WRAPPED IN A
ON -WOVEN GEO-TEXTILE ENVELOPE
(FABRIC EQUIVALENT TO AMOCO 4545)
2) CRUSHED STONE NOT TO EXCEED #2 IN
SIZE. GRANULAR FILL TO MEET THE
FOLLOWING REQUIREMENTS:
0 % IN EXCESS OF 3"
25 %-75% PASSING #4 SIEVE
0 %-15% PASSING #200 SIEVE
TRENCH DETAIL
NOT TO SCALE
INSPECTION REQUIREMENTS:
ENGINEER OF RECORD TO INSPECT TRENCHES PRIOR TO BACKFILLING.
EXISTING
FIELD SE
(TO BE ,
LOT 107
/V ORTH
LOT 108
i
,S
ALP/NE AVENUE
TANK
-TRIBUTION Box #2
- SHEET 2)
)NIT
VITARY LEACH
:ING LOT 105
,BANDONED)
SORPTION FIELD
3 FT. EACH TO
LOTS 105 & 106
- SHEET 2)
NOTE:
MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION.
UNDWATER BEDROCK
IMPERVIOUS LAYER
CROSS SECTIONAL VIE
FLOW
CRUSHED STONE OR/
WASHED GRAVEL
3/4 TO 1 Y2„
W LONGITUDINAL VIEW
TERRATEX NO. 2 NONWOVEN CONSTRUCTION FABRIC
NTREATED BUILDING PAPER OR PERMEABLE
GEOTEXTILE OR 4" LAYER OF STRAW "II r I' -11111 111► ► II I r1i i=
=IIIII1 1111111=
0 0 a763200 0 0 0 00 0
PROVIDE CAPS
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o ON LINE ENDS
00 00
o� 017
7 00 � 00 0 0 00 O O
SLOPE PIPE X5" -Y32" PER FT.
SPACING OF ABSORPTION TRENCH 6' O.C.
TRENCH BOTTOM TO BE NEAR
LEVEL AND RAKED
TRENCH PROFILE
ABSORPTION TRENCH DETAIL
NOT TO SCALE
GRADE
TOPSOIL FOR SETTLING
NOTE:
-
I. PIPE JOINTS TO BE SEALED WITH
MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY
-I I —III = —IIII-
=IIII—IIII— I— I ( —IIII
TERRATEX NO. 2 NONWOVEN
2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE
EARTH IIII
BACKFILL
III—
—IIII- EARTH IIII—
-IIII— BACKFILLI=IIII
CONSTRUCTION FABRIC OR
UNTREATED BUILDING PAPER
OR STRAW
TOP OF AGGREGATE
TO BE WITHIN
6"-12" OF SURFACE
OUTLET PIPES MUST BE EQUAL.
O2O L O
U O RAKE ANY
SMEARED
=IIII —
4" PVC MIN.
'
00 O
PERFORATIO %JOINT
MISALIGNMENT/BREAKAGE.
BETWEEN THE DISTRIBUTION BOX
3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHALL BE AS
TRENCH
O
DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL.
SHOULD BE 118" PER FOOT.
BAFFLE
;
O WALLS
INVERT
INLET 2"MIN
j/�7
/7 �O/7/7 /7 / a
(`/(�/�
/ O /7/7
O
UNDWATER BEDROCK
IMPERVIOUS LAYER
CROSS SECTIONAL VIE
FLOW
CRUSHED STONE OR/
WASHED GRAVEL
3/4 TO 1 Y2„
W LONGITUDINAL VIEW
TERRATEX NO. 2 NONWOVEN CONSTRUCTION FABRIC
NTREATED BUILDING PAPER OR PERMEABLE
GEOTEXTILE OR 4" LAYER OF STRAW "II r I' -11111 111► ► II I r1i i=
=IIIII1 1111111=
0 0 a763200 0 0 0 00 0
PROVIDE CAPS
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o ON LINE ENDS
00 00
o� 017
7 00 � 00 0 0 00 O O
SLOPE PIPE X5" -Y32" PER FT.
SPACING OF ABSORPTION TRENCH 6' O.C.
TRENCH BOTTOM TO BE NEAR
LEVEL AND RAKED
TRENCH PROFILE
ABSORPTION TRENCH DETAIL
NOT TO SCALE
GRADE
1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR
NOTE:
BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE
I. PIPE JOINTS TO BE SEALED WITH
MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY
ASPHALTIC MATERIALS OR EQUIVALENT.
I2" MIN REMOVABLE CO VER -7
2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE
EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS
2. INVERT ELEVATIONS OF ALL
REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (I.E., SETTLE
OUTLET PIPES MUST BE EQUAL.
CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE
'
J. THE SLOPE OF OUTLET PIPES
MISALIGNMENT/BREAKAGE.
BETWEEN THE DISTRIBUTION BOX
3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHALL BE AS
•: AND THE DISTRIBUTOR LATERALS
DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL.
SHOULD BE 118" PER FOOT.
BAFFLE
;
INVERT
INLET 2"MIN
EL EV.
THE TRENCHES.
O
O O
OUTLET CONTRACTOR TO USE SPEED LEVELERS
FOOT. PRESSURE OR DOSED DISTRIBUTOR PIPE SHALL BE INSTALLED LEVEL. GRADES SHALL BE
AS SUPPLIED BY FORT MILLER TO
_
EQUALIZE FLOW.
12" MIN
FACING DOWN ON THE DOWNSTREAM TOP OF THE DISTRIBUTOR PIPE, A CARPENTER'S LEVEL CAN BE
CLEAN SAND OR
PEA GRAVEL
2
DISTRIBUTION BOX
NOT TO
SCALE
A DEPTH OF AT LEAST TWO INCHES ABOVE THE TOP OF THE DISTRIBUTOR PIPES. ADDITIONAL
SHEET 2 OF 2
SAN/ TAR Y DETAILS FOR
LOT 106 ALPINE AVENUE
HOMES TEA D V/L L A GE
TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK
SCALE: 1 " = 20' SEPTEMBER 21, 2006
ENVIRONMENTAL DESIGN PARTNERSHIP, LLP
900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621
ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING
JAMES E. MITCHELL P.E. 53,337
BORING AND PERCOLATION TEST:
TEST PERFORMED SEPTEMBER 27, 2006
0-5' MEDIUM FINE SAND
NO WATER OR MOTTLING
PERCOLATION RATE APPROXIMATELY ONE MINUTE
SEPTIC DESIGN:
APPLICATION RATE = 1.2 GAL./SF/DAY
LOT 105
3 BEDROOMS AT 100 GALLONS/BEDROOM
=300 GALLONS
LOT 106
3 BEDROOMS AT 100 GALLONS/BEDROOM
=300 GALLONS
TOTAL
6 BEDROOMS AT 100 GALLONS/BEDROOM
= 600 GALLONS
USE 4 LINES AT 63 FT. EACH (SPACED 6 FT. ON—CENTER)
CONSTRUCTION NOTES:
1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR
THE SOIL MOISTURE CONTENT IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMATELY NINE INCHES
BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE
MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY
MUST BE PRESENT FOR A RIBBON TO BE FORMED.
2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE
EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS
REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (I.E., SETTLE
NATURALLY FOR A PERIOD OF AT LEAST SIX MONTHS, INCLUDING AT LEAST ONE FREEZE -THAW
CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE
DESIGNATED ABSORPTION SYSTEM AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY
REDUCTION DUE TO COMPACTION PLUS POSSIP.I F TPPN(7H CAVE -!N ANID !?!STP!9[jT!-0N PIPE
MISALIGNMENT/BREAKAGE.
3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHALL BE AS
SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE EXCAVATED TO
DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL.
4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF
THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO
ASSURE THAT EACH IS PRACTICALLY LEVEL. TRENCH BOTTOMS AND SIDEWALLS SHOULD BE
IMMEDIATELY RAKED AFTER FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED IN
THE TRENCHES.
5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY INSTALLED AT A SLOPE OF Y6 TO Y32 INCH PER
FOOT. PRESSURE OR DOSED DISTRIBUTOR PIPE SHALL BE INSTALLED LEVEL. GRADES SHALL BE
DETERMINED BY AN ENGINEER'S LEVEL, TRANSIT OR CARPENTER'S LEVEL. AN EASY METHOD OF
MEASURING THE Y6 INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A Y4 INCH BLOCK TO
ONE END OF A STRAIGHT FOUR FOOT BOARD. BY PLACING THE BLOCKED END WITH THE BLOCK
FACING DOWN ON THE DOWNSTREAM TOP OF THE DISTRIBUTOR PIPE, A CARPENTER'S LEVEL CAN BE
USED TO DETERMINE THE Y6 INCH PER FOOT SLOPE. A Ya INCH BLOCK SIMILARLY USED WOULD
RESULT IN A Y32 INCH PER FOOT SLOPE. ANOTHER METHOD USED TO ESTABLISH THE GRADE OF
DISTRIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL BE INSTALLED IN THE TRENCHES TO
A DEPTH OF AT LEAST TWO INCHES ABOVE THE TOP OF THE DISTRIBUTOR PIPES. ADDITIONAL
AGGREGATE MAY BE REQUIRED TO BRING THE TOP OF THE AGGREGATE TO WITHIN SIX TO 12 INCHES
OF FINAL GRADE.
O
6) AFTER THE UPPER AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE, UNTREATED BUILDING,, -,-,"_n
PAPER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AND THE TRENCH'
C ILLED WITH EXCAVATED SOIL. IF THE TRENCHES CANNOT BE IMMEDIATELY BACKFILLED, THE
KW YORK SUM D'EPA 11090 HES SHOULD BE TEMPORARILY COVERED WITH AN IMPERVIOUS MATERIAL, SUCH AS TREATED
ea I
GLMFAUSDW=oFfjWILDING PAPER TO PREVENT SIDEWALL COLLAPSE AND SILTATION INTO THE AGGREGATE.
�
`0C
-CD N
10.6-06 7) THE EARTH BACKFILL 15 TO BE MOUNDED SLIGHTLY .ABOVE THE ORIGINAL GROUND LEVEL (LE., NOT
� �'10.6-06
TED) TO ALLOW FOR SETTLING. FOLLOWING SETTLEMENT, THE ENTIRE AREA SHOULD BE �M;o
These plans 101-1. GRADED WITHOUT�THE`USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT
OT ENTER..`THE ABSORPTION FACILITY AREA OR THE PROPOSED EXPANSION AREA AFTER THE
';I1RSIIRFACE SEWAGE TREATMENT SYSTEM HAS BEEN CONSTRUCTED.
are hereby Approved b . : `
• 1VN
f A
� j
for the State CotimmWsiiuW of Hoeft
qj 410.0 gtaoljos ,
uI P"anS28CU Alf,;
sir G ns �n
SHEET 1 OF 2 1 �C �E����, ���, I
,IIr�I�aP Seuo U,�
SEP T/ C DESIGN PREPARED FOR;° e "I "s so a >a
�nc
i a L O T O 6 ALPINE A VENUE --.-
HOMES TEA D V/L L A GE
TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK
SCALE: 1 " = 20' SEPTEMBER 21, 2006
ENVIRONMENTAL DESIGN PARTNERSHIP, LLP
900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621
ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING
JAMES E. MITCHELL P.E. 53,337