Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2006-909
TOWN OF QUEENSBURY ice 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20060909 Date Issued: Monday, January 22, 2007 This is to certify that work requested to be done as shown by Permit Number P20060909 has been completed. Tax Map Number. 523400-288-000-0001-055-000-0000 Location: 1439 STATE ROUTE 9 Owner. L. & M. ASSOCIATES L.L.C. Applicant: L. & M. ASSOCIATES L.L.C. This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, l Variance,or other issues and conditions as a result of approvals by the Director of Building&Code nforceinent Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY .4101Ac irro 742 Bay Queensbury,' nsb NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060909 Application Number. A20060909 Tax Map No: 523400-288-000-0001-055-000-0000 Permission is hereby granted to: L. &M. ASSOCIATES L.L.C. For propertylocated at: 1439 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: L. &M. ASSOCIATES L.L.C. 1439 STATE RT. 9 SUITE 16 Commercial Alteration $500.00 LAKE GEORGE,NY 12845 Total Value $500.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2006-909 168 SQ FT COMMERCIAL ALTERATION $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,January 04,2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tiref. Quee uty' 'h sday,January 04,2007 SIGNED BY for the Town of Queensbury. Director of Building : Code nfoitement .1/4- 06 ,AZ -- f _ OFFICE USE ONLY / RErEIVED TAX MAP NO. PERMIT NO. FEES: PERMIT RECREATION ENGINEERING D U : 8 OO6 (If applicable) TA.361N. .......�cl‘sablJgY BUILDING AND CODE PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID� PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: f Iid° s . OWNER: �Cq © L- 5 q ADDRESS: L ��lCcit Lq/ADDRESS: 74"---‹g ` CAC lc? PHONE NOS. ,> '27- - l T-3" PHONE NOS. C.( —1-2 Ct/ ( LL CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: C( 6d PHONE: r / [L` g3 LOCATION OF PROPERTY: /v j'6 - SI -- ` -' SUI-VMSIDN NAME: 7 t"( 44 0,0 6, tir 0,3s (,),,-„--- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR O 1 0 a o LL co PROJECT O F J O I- _ o Q cU o Z_ Z Q Q i- g N � OLL 0i-:LI- CK UJ jf SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICES ) ---'--= r \ RETAIL- / i MERCANTILE 44 ' �- 71 fd)e/,�.-(- (4.0 7/7 16(S St r F TORY-0R �. —.—_y INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: OQ.DU FUEL TYPE: 6\ r, HEAT TYPE: C 5 *HOW MANY FIREPLACE(S): �.J Gl AND/OR WOODSTOVES(S): C J ZONING CATEGORY: ARE ( THERE WETLANDS ON THIS SITE? P Zi IS THIS A HISTORIC SITE? /i/I 0 PROPOSED USE OF BUILDING OR ADDITION: (la, ‘ , I *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 a ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? e ARE THERE EASEMENTS ON PROPERTY? /(1-0 I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) • 4 , 4 4 4 • Permission is hereby granted to the above I: This application/proposed action described Applicant to erect or alter the building : ; herein is found to be in accordance with the ; described herein in accordance with said ; zoning Laws of the Town of Queensbury. Application: : ; • / • • • , , i i / • • , •, BUILDI G C r•y!: APPROVAL % ; ZONING APPROVAL ; • , •, , , j -V' , , DAT •• •• DATE • QUESTIONS? CALL 761-8256 OR EMAIL codes at queensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.aueensburv.net iii,kTown of Queensbury. Community Development Office 742 Bay Road, Queensbury, NY 12804 = Commercial Final Inspection Report Office No.: (518) 761-8256 Date Ins ction re+u-: -c- •. Queensbury Building&Code Enforcement Arrive: bp' .4t• Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initial.. NAME: QaEICE.,157 _ PERMIT . � LOCATION: FREOCH C'C-0 Cotip.AD DATE: — — r COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks _ Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 /2 doors > 10%> 1000 sq.ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides '/Driveable Surface 20'wide Okay To Issue Temp. Permanent CIO Okay To Issue C/C L:1Building&Codes Forms\Building&Codesllnspection Forms\Commercial Final Inspection Report.doc JN-19-200T 06 :40 PM FRENCH MOUNTAIN COMMONS 5187921731 P 0 1 911fflinV%t French Mountain Commons „FRENCH—MOUNTAIN Is. 1430 Sista Fir)ute 9,#16 Lake Geotge, NY 12545 :COMMONS.. Phone: 615—792—1483 FAX: 518—792-1731 . . • ; • .• t From: V .•• Fax: Peeing •.. Phone; Bate; Rea t . Urgent allfor Review 0 Please Comment, 0 Please Reply 0 Please Recycle •Commentel . -- ebk .") t"- cCo c \vs. C's e ••• Ovt ck 1.f e:. ( ..• • • •:!1 • N m u M l` N COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. t` Main Office 176 Doe Run Road-Manheirn,PA 17545 CO MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL In Permit No. Cert. No 90 5 53 Cut-in Card No.__. Owner1�r��.:►G: / ......................................._-----...._.................... ./..._. p Location Ll4r.7-3 E�'� C /e EInstallation Consisting of/1.I-, _6.-..-A7e z`.ee2-_ez Err/4M4: ..............._-- a Installed By....l_'D.PF c4 _Gj�itJGL.?/rS.,... ..._Lir.No........-._...._^_.__._....... ._..._.__.. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- O This certificate only covers the electrical equipment and installation conditions as of date. Upon the E introduction of additional equipment or alterations,application shall be promptly made for inspection. _ Inspectors of this Company shalt have the privilege of makime inspections at any time, and if its U rules are violated,the Company shall have the right to rev e ih' owl fir Date.. `1.!.� 7 INSPECTOR. __ ...... ......... 11 Member N.F.P-A.,LA.E.. E Q. td - m h . N 1 • 0 I ti . Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No._ d`f'` qa , Town of Queensbury 742 Bay Road i ! I i U Queensbury,NY 12804 Scheduled Inspection Date:_ Time: Phone: (518)761-8206 Business Name: K1 (N 41, LA... 7.--- Fax: Fax: [518) 745-4437 Location: k n '-t,ki) APO r`' CuwvvN-A..-a Type of Inspection N/A Yes No EXITS: .,' Exit AccessCOMMENTS Exit Enclosure Exit Discharge i EVAC Plan AISLES: Main Aisle Width .j/ Secondary Aisle Width 1/ EXIT SIGNAGE Sign-normal /, Sign-battery / i! -•:uShal IfSpeCGonn Complete EVAC signs in rooms v �• may pectued NLY ple ith TRUSS ID SIGNAGE 1/' 4<.ildifig& p approval /./.. ` EMERGENCY LIGHTING •1 FIRE EXTINGUISHER: - ` 1 9 � �� Hung ilk di habit.a/- Inspection of extinguisher F Marshal Hydro extinguisher lown of Queensbury FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System i/' Fire Suppression-kitchen 1..--- Fire Fre Suppression-Gas Island t/ Hood Installation Interior Finishes t. Storage 1/ Compressed Gas V Clearance to Sprinklers Clearance to Electrical 1/ Electric Wiring Enclosed Combustible Waste V Vehicle Impact Protection Fire Lane F.D.Signage-Utility Rooms Na Smoking Signs / Maximum Occupancy Sign Y/ Emergency Evacuation Plan +/ .,Approved (If no other approvals apply,the B &C Office will issue the Certificate of Occupancy) ❑ Denied ❑ Call for Recheck a/ Inspecte• By: - I &� L:\FireMarshal\insptopermitto occupyform.doc Commercial Final Inspection Report Office No.: (518)761-8256 Date Ins ectioe• - - ='ved: Queensbury Building&Code Enforcement Arrive: 5n r5-a OP� Depart: ZIP a pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials�� NAME: KV tJ - PE' : O(Q-CICSt LOCATION: 1\-V:25:\__ I-c E Q.'SF°\ D• ! -- \(6-07 COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.-38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 V2 doors > 10%>1000 sq.ft. 3/a Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required • Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp.or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building 8s Codes\Commercial Final Inspection Report.doc e-/o , 0-- Framing / Firestopping Inspection Report vCf` Office No. (518) 761-8256 Date Ins•ecti•n re• .-st r- -iv;:: ci 7 1-- Queensbury Building&Code Enforcement Arrive: ' .J' : Part:q-1), 742 Bay Road, Queensbury,NY 12804 Inspector's Initia s:.. NAME: j�� - r^-J-C t� aa / PERMIT if: d - 7ju LOCATION: l ' - I INSPECT ON: 7/16°;01-4‹..--\_ 7 >7 TYPE OF STRUCTURE: AA' mir Y N N/A COMMENTS Framing J DO C30 tfic Access 2"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 11/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Nork Purchase Schedule T. C. TEN. I LL SUPPLIED REMARKS F= FURNISH I- INSTALLBY: EUF I rF I F I P Perm I is BUILDING PERMIT • • PERMIT TO INSTALL FIXTURES i • • IF REQUIRED StoreFront SIGNAGE ROVIDE SEPARATE a 1 • • PERMIT BY LANDLORD BLADE SIGN 1 • 4�11 T.G.G. TO COORDINATE BACK DOOR SIGN U -CHANGE LOCKS • ?0 IMETRO DOOR G.G. TO COORDINATE Interior PAINTING WALLS • • ' PI CARPET • • A.F.R. WALK -OFF MAT 1; • 1 • , TILE • • A.F.R. WOOD FIXTURES FLOOR • ' • WOODWORKS REFER TO DRAWING A.1 METAL PERIMETER FIXTURES WALL fI l' • • SYNDICATE REFER TO DRAWING A.1 AUDIO SYSTEM I DMX INSTALL AUDIO SYSTEM, l • Il • 800.831.8001 SPEAKERS AND WIRE PARTITIONS l • • r • I' SALES/STOCK DOOR • 3 i DEMISING WALL5 • • • CEILING • I • ` EXISTING GRID NEW PANELS IN SALES MIRRORS • ` ABC # GM 1860 SEATING i • • 1 1 CHAIRMASTERS ELECTRICAL PANEL GRAPHIC HOLDERS • • SWINGFRAME • GYP. BD • • I • . DAMPING • TO HEIGHT REQ'D. BY CODE MUSIC ALIGHT FIXTURES • 800.831.8001 206.325.71017 Stockroom • JON GEIDER 845.265.0075 OUTLETS * SWITCHES SHELVING SYSTEM • • EXCAL15UR • MANAGER'S DESK • a TELEPHONE EQUIPMENT 800.523.0112 215.08.453q REDUCER TIMER FOR SIGN • 203.245.1(og7 203.245.3303 FLOOR / VINYL BASE • 9 • • • CASH REGISTERS STOCK LIGHTING • • WEIDENBACH 631.382.3637 SERVICE DOOR • DEMOLITION 847.g67.403q SUPPLEMENT HARDWARE Lavatory SCHWAR T Z ,I 847.g67.403q 847.966.1271 ACCESSORIES •; TIM HESTER 508.g87.8151 508.987.7045 CEILING • Il 212.736.3838 212.62q.0455 RESILIENT OR TILE BASE • JULIE BEDFORD g14.846.1462 gl4.235.1356 TILE / TRANSITION •_ I THERMOSTAT LIGHTSTAT 1-IVAC 9 s i DIFFUSERS / DUCTWORK • I EXHAUST FAN 4 VENT • RETURN AIR GRILLES " • HVAC UNIT 7FRIFY W/ MECP. DR WI G5 WAT91R PEATES)• li THERMOSTAT • TGG TO RELOCATE AS SHOWN Fire Protection HEAT DETECTION N / A SMOKE DETECTION • SPRINKLERS • T.G.G. TO RELOCATE AS REQUIRED FIRE EXTINGUISHERS • FIRE ALARM SYSTEM • f� TGC TO MODIFY AS REQ'D. Flumbin r FIXTURES •-j NEW BY T.G.G. STUB • N I RELOCATE 21 Electrical VENDOR CONTACT PHONE ELECTRICAL PANEL • A.F.R. VERIFY W/ ELECT. DRAWINGS EMERG ENCY/EXIT LIGHTS • SEATING PODS CHAIRMASTERS . DAMPING • 718.282.0613 MUSIC ALIGHT FIXTURES • 800.831.8001 206.325.71017 T RACK LIGHTING • JON GEIDER 845.265.0075 OUTLETS * SWITCHES • • • 1 T.G.G. TO MODIFY AS REQ'D TELEPHONE CONDUIT/ WIRING • • • FROM PANEL BOARD AND DEMARC TELEPHONE EQUIPMENT 800.523.0112 215.08.453q • • TIMER FOR SIGN • 203.245.1(og7 203.245.3303 CASHWRAP POWER / SIGNAL/ TEL General KARPS • • CASH REGISTERS LOCKS METRO DOOR • • GLEAN -UP 631.382.3637 0 • DEMOLITION 847.g67.403q • • NOTE: UPON AWARD OF CONTRACT IT IS THE RESPONSIBILITY OF THE G.C. TO CONTACT ALL VENDORS TO ORGANIZE DELIVERY DATES FOR ALL TENANT SUPPLIED ITEMS. DO NOT WAIT UNTIL THE LAST MINUTE TO RELEASE MATERIAL. COMPLETE " MATERIAL RELEASE FORM" SUPPLIED WITH " INSTRUCTION TO BIDDERS" AND SUBMIT TO JONES RETAIL CORP. ANY ADDITIONAL; FREIGHT CHARGES INCURRED AS A RESULT OF WAITING TOO LONG TO RELEASE THESE MATERIAL, WILL BE PAID BY THE GENERAL CONTRACTOR. CODE REV I EN : FRENCN MOUN7AIN C0M["IONS 143Q, STATE R0/U-_I_E q, #3 LAKE GEORGE; SALES AREA: 2,253 S.F. / 30 OCCUP. PER S.F. = 76 OCCUPANTS STOCKROOM: 870 S.F. / 300 OCCUP. PER S.F. = 3 OCCUPANT TOILET ROOM: 30 S.F. = 1 OCCUPANT MECHANICAL ROOM: 28 S.F. = 1 OCCUPANT TOTAL OCCUPANTI-OAD - 81 OCCUPANTS OCCUPANCY: (C2) MERCANTILE SINGLE STORY OUTDO:'>R MALL WITH NO SITE WORK REQUIRED INTERIOR ONLY - NO ZONING CONDITIONS STORE FLOOR PLAN AREA: 3,181 50. FT. NO HAZARDOUS MATERIALS WILL BE STORED SEPARATION BETWEEN TENANTS: EXISTING- I HOUR DISTANCE TO EXIT: MAXIMUM 150'/ PROVIDED 40' NUMBER OF EXITS: 2 REQUIRED / 2 PROVIDED V F.N DOR LIST NY 12 8 4 5 BU I LD I NG DATA PROVIDE FIRE EXTINGUISHER: 1 TYPE A, B, C INTERIOR FINISHES: WALL 4 CEILIING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATION IN CODES RULES AND REGULATIONS OF THE STATE OF NEW YORK DRAWINGS TO COMPLY WITH THE FOLLOWING CODES: CODES RULES AND REGULATIONS OF THE STATE OF NEW YORK CONTRACTOR TO PROVIDE COMPLETE "CONTRACTOR REPORT" PROOF OF WORKERS COMPENSATION INSURANCE AND CITY BUSINESS LICENSE IF REQUIRED. ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH T14E SPECIFICATIONS, DRAWINGS * SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. SIGNAGE TO BE UNDER SEPARATE PERMIT OR AS REQUIRED - PROVIDED BY LANDLORD STORE COMPONENT VENDOR CONTACT PHONE FAX CARPET TILE ENTRANCE MAT A.F.R. COLDIT THOMPSON 212.290.0200 212.280.2855 SEATING PODS CHAIRMASTERS JEFF JAHIER 718.282.0600 718.282.0613 MUSIC DMX KANYA SARAPANICH 800.831.8001 206.325.71017 T -STANDS DUMP TABLE ECONOCO JON GEIDER 845.265.0075 845.265.0075 STOCKROOM SHELVING EXCALIBUR HOWARD MARKOWITZ 732.828.1687 732.928.0568 LADDERS FRED HILL DIANE FISHER 800.523.0112 215.08.453q VACUUMS HOWARD SERVICES BARSTEIN 203.245.1(og7 203.245.3303 HANDTRUCKS KARPS _NOEL ALI SANDLOCK 203.327.0460 203.327.2210 LOCKS METRO DOOR MIKE POLIZZI 800.668.3667 631.382.3637 SAFE'S SCHWARTZ KATY SCOTT 847.g67.403q 847.966.1271 CLEANING SUPPLIES SCHWAR T Z KATY SCOTT 847.g67.403q 847.966.1271 METAL FIXTURING SYNDICATE SYSTEMS TIM HESTER 508.g87.8151 508.987.7045 STOREFRONT SIGNAGE MIDTOWN NEON ALBERTO GAITIAN 212.736.3838 212.62q.0455 LIGHTING WIEDENBACH BROWN JULIE BEDFORD g14.846.1462 gl4.235.1356 MILLWORK WOODWORKS RICK IRISH THERMOSTAT LIGHTSTAT G.G. TO REMOVE FITTING ROOMS, DOORS, AND BENCHES AS INDICATED BY DASHED LINES G.G. TO REMOVE WALLS AS INDICATED BY DASHED LINES EXISTING SERVICE DOOR TO REMAIN EXIST. TOILET ROOMS * PLUMBING FIXTURES TO REMAIN. - ------- REMOVE EXISTING FLOOR FINISH - PREPARE FOR NEW REMOVE ALL WALL FINISHES - PREPARE FOR NEW. (TYP.) PIS-�r Ln REMOVE EXISTING FLOOR FINISH - �. PREPARE FOR - NEW CARPET El +F IP 9-`,T 7 - F- T -I E l r - b 0= -0 0= �1 -ti 1 I 1 ! t i = L {% _0 L =0al ----� I REMOVE EXISTING FLOOR FINISH - PREPARE FOR NEW I I I REMOVE ALL WALL FIXTURES * FLOOR FIXTURES AS INDICATED BY DASHED LINES. NOTE UPON AWARD OF CONTRACT IT IS THE RESPONSIBILITY OF THE G.G. TO CONTACT ALL VENDORS TO ORGANIZE DELIVERY DATES FOR ALL TENANTS SUPPLIED ITEMS. DO NOT WAIT UNTIL THE LAST MINUTE TO RELEASE MATERIALS. COMPLETE "MATERIALS RELEASE FORM SUPPLIED WITH "INSTRUCTION TO BIDDERS AND SUBMIT TO JONES RETAIL CORP. ANY ADDITIONAL FREIGHT CHARGES INCURRED AS A RESULT OF WAITING TOO -ONG TO RELEASE THESE MATERIALS, WILL BE PAID BY THE GENERAL CONTRACTOR. EXISTING STOREFRONT GLAZING SYSTEM TO REMAIN; T.G.C. TO "CLEAN TO A LIKE NEW CONDITION" EXISTING WALK OF MAT TO BE REMOVED. EXISTING STOREFRONT GLASS DOORS TO REMAIN; T.G.C. TO 'CLEAN TO A <E NEW CONDITIC', INDEX OF DRAWINGS T1 COVER SHEET, KEY PLAN, DEMOLITION >'LAN A1.0 FIXTURE PLAN / FLOOR PLAN SCHEDULES A2.0 INTERIOR ELEVATIONS * DETAILS A3.0 REFLECTED CEILING PLAN A4.0 POWER PLAN ARCHITECT ROBERT F. VANNEY 360 N. ROBERT STREET SAINT PAUL, MN 55101 ATTN: ROBERT VANNEY (651) 222 - 4642 EXT. 12 PHONE (651) 222 - 3034 FAX 1"1FF CONSULTANT 11 CONTACTS OWNER / TENANT: JONES NEW YORK RETAIL / NINE WEST GROUP 112q WESTCHESTER PLAZA WHITE PLAINS, NY 10604 NEIL DORSO (q14) 640-3516 BUILDING OFFICIALS GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE CITY OF QUEENSBURY, NY. BUILDING DEPT. FOR ALL THE NECESSARY PERMITTING COSTS 4 LICENSING REQUIREMENTS. SCOPE OF NORK ,_ONVERSION OF A EXISTING RETAIL SPACE INTO A "NINE WEST" STORE. THE MECHANICAL AND ELECTRICAL SERVICE WILL BE MODIFIED, CEILING TO REMAIN AS IS. TENANT COORDINATOR TENAJT GOOR'DINATOR: ED MOORE 1439 STATE ROUTE q, #16 LAKE GEORGE, NY 12845 PH: 518-7q2-1483 NOVICE � VER HANDLES REQUIRE KEY PLA A� L PASSAGE DOORf HER INTERIOR OR EXTERIOR DOORS 87 FRENCH MOUNTAIN COMMONS R GI -8& DEC 2 8 , 06 s TOWN Ur UUtralvz:,oURY BUILDING AND CODE TOWN OF QUEENSBURY SUR.O;r„r E�E:B�RTMENT Based on our limiteats s oxamel GLRNE compliance with our comments snail -_- _ not be construed as indicating the plans and specifications are in full compliance with the Building Codes of New YorK State. NINE NEST PrRENCH 1” IOUNTAIN COMMONS z 439 STATE ROUTE 9 #3 LAKE GEORGE, NY 12845 ..,,.V. 'RCHITCT .... E ... ............ ,60 N. ROBERT S R Tl ..2Q1, ,AINT PAX,! T 5101 1 2 41 51 I Con Hants s IIST FRENCH MOUNTAIN COMMONS LAKE GEORGE, NY space #3 commission 13-0076number drawn RFV reviewed RFV ❑ preliminary ® final 11/10/06 bidding 11/10/06 • permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title TITLE SHEET VICINITY MAP DEMOLITION PLAN sheet number T 1 FINIS-! SCHEDULE SYM TYPE n :SCRIEMON MANUFACTURER CATALOG NO. @ 68/75 PRS. = DECORATOR WHITE F2 (14) DECORATOR P1 PAINT SATIN ON WALLS BENJAMIN MOORE WHITE PRS. 1260/1456 PRS. SEPTI -GLOSS ON TRIM 4' W. 2 <6> PAINT SATIN ON WALLS BENJAMIN MOORE #7q5 FADED DENIM 540/624 PRS. F3a (0) 4' W. X V-0" H. WALL SUPPLIED AND 0/0 PRS. M MIRROR MOUNTED IS x 60 MIRROR INSTALLED BY T.G.G. ABC #GM -1860 AO TILE 12" x 12" BLUE OASIS AFR - - EXISTING LIMESTONE TILE GLEAN LIKE NEW R-5 OCARPET C 37011 x '7 0 r EXISTING VIEWPOINT CAMBRIDGE #VPT07 SKY BOX -SE AS REQUIRED CLEAN LIKE NEW 4' D. x 6' H, EXISTING HARDWARE / NEW AS REQUIRED (V.I.F.) SET 1 Op WALK -OFF ALUMINUM ROLL -UP SUPPLIED HINGES (1 1/2 PAIR) GONDOLA MAT W/ CHARCOAL BY AFR TOP JAMB CLOSER DORMA - 640 3'-0" FLOOR 0 CARPET INSERT SET 4 �DETEX' PANIC DEVICE; OTRANSITION 180 DEGREE VIEWER; BY T.G.C. ALUMINUM J -MOLD AFR #A-31010 SEATING UNITS) STRIP NON -REMOVABLE PIN BALL BEARING HINGES; BY T.G.G. 212.280.0200 5CA TI TRANSITION BLACK VINYL MERCER #q30/101 T -STAND I REDUCER F•g ® BASE 4' BLACK VINYL BY FC F 10 WINDOW DISPLAY 2 COVE 2 TIERED TABLES (MAPLE) PAINTING NOTES: 1. PAINT SALES AREA WALLS SATIN PI (1 COAT PRIME) (2 COATES FINISH), REFER TO DRAWING A.3 FOR LOCATIONS. 2. INSTALL COLOR SPACE VINYL GRAPHIC BEHIND DESK. PAINT P2 ACCENT ON REAR WALL. ALL FINISHES SHALL HAVE A MINIMUM CLASS I FLAME SPREAD RATING OR HAVE A FIRE RETARDANT TREATMENT TO ACHIEVE THIS RATING. NOTE: REFER TO SHEET T1 WORK PURCHASE SCHEDULE FOR ALL TENANT SUPPLIED ITEMS AS WELL AS VENDOR INFORMATION 8' HIGH SALES SHELVING UNITS PERIMETER FIXTURES F2a (9) 3' W. X V-0" H. @ 68/75 PRS. = 612/675 PRS. F2 (14) 4' W. X 8'-0" H. @ qO/104 PRS. 1260/1456 PRS. F3 ((o) 4' W. X 8'-0" H. @ 010/104 PRS. = 540/624 PRS. F3a (0) 4' W. X V-0" H. @ 80/104 PRS. 0/0 PRS. TOTAL PRS. - 2412/2755 PRS. FLOOR FIXTURES F5a (0) 3' W. X 4' H. @ q0/100 PRS. = 0/0 PRS. F5 (35) 4' W. X 4' H. @ gO/126 PRS. 3150/4410 PRS. TOTAL PRS. = 3150/4410 PRS. TOTAL PRS. - 5562/7165 PRS. (0) 2' W. X 8'-0" H. @ 38/58 PRS. = 0/0 PRS. (12) 3' W. X W -O" H. @ 58/% PRS. = 6016/1152 PRS. (28) 4' W. X V-0" H. @ 96/116 PRS. - 2688/3248 PRS. TOTAL PRS. - 3384/4400 PRS. X124" x 36" ADA X3:_0" z� COUNTER AT 34" A.F.F. OC CARPET MIN. V-0" F *HANDICAPPED ACCE551BI E SALES COUNTER PER SECTION 1108.9.3 2 H.C. CASHDESK DETAIL_ 1.0 1/2" = 1'-0" VCT - EXISTING #q30/101 MERCER CARPET REDUCER CARPET 3 FLOOR TRANSITION DETAIL 1.0 NOT TO SCALE 4 FLOOR TRANSITION DETAIL 1.0 NO•r TO SCALE DOOR SCHEDULE FIXTURE: DOOR # LOCATION 51ZE MATERIAL THICKNESS DOOR FRAME MATERIAL FIRE HARDWARE RATING REMARKS DR -1 STOREFRONT (2) 3'-0" x 7'-0" _ - EXISTING - SET 1 CLEAN LIKE NEW SYNDICATE ENTRY EXISTING WALL UNIT 3'-0" W. PERIMETER STOCK 3'-0" x 0 _511 EXISTING ASSEMBLY REQUIRED BY TGC EXISTING - SET 2 AS REQUIRED CLEAN LIKE NEW R-3 T'OILE'r ROOM 3'-0" x 6'-8" EXISTING _ - EXISTING - SET 2 AS REQUIRED CLEAN LIKE NEW MECH. ROOM 3'-0" x (0'-8" EXISTING - - EXISTING SET 3 - AS REQUIRED GLEAN LIKE NEW R-5 SERVICE DOOR 37011 x '7 0 r EXISTING _ - EXISTING -SE AS REQUIRED CLEAN LIKE NEW o DOOR SCHEDULE L I ST SUPPLEMENT EXISTING HARDWARE / NEW AS REQUIRED (V.I.F.) SET 1 U -CHANGE LOCK WITH CONSTRUCTION SET 3 LEVER ACTION PRIVACY SET: FALCON T581 -D-626 WOODWORKS CORE BY T.G.G. PERMANENT CORE HINGES (1 1/2 PAIR) GONDOLA SUPPLIED BY J.R.G. AT TURNOVER. DOOR STOP: 'IVES' 408 1/2, SILENCERS SR64 SET 2 TOP JAMB CLOSER DORMA - 640 3'-0" FLOOR 0 PUSH PLATE : IVES #8200 26D 4X16. SET 4 �DETEX' PANIC DEVICE; KICK PLATE 'IVES' #8400 26D 6X34. 180 DEGREE VIEWER; BY T.G.C. FLOOR DOOR STOP : 'IVES' #FS450. PUSH BUTTON / BUZZER; SEATING UNITS) WALL BUMPER : 'IVES' #409 1/2 NON -REMOVABLE PIN BALL BEARING HINGES; BY T.G.G. PULL ON STOCK SIDE : 'IVES' #8112-5 OR EQUAL. SMOKE GASKET; IF NOT 1 HINGES : 1 1/2 PAIR BUTT HINGES, HAGAR #1279-U526. TOP JAMB CLOSER: 'CORBIN RUSSWIN' DC422-AI EXISTING SYI I130,1_ LEGEND DETAIL NUMBER EXISTING DOOR DETAIL SYMBOL DRAWING NUMBER - SOFFIT / CEILING LINE EXISTING CONSTRUCTION TO REMAIN PATCH AS REQUIRED PER CODE/LL NEW WALL CONSTRUCTION WALLTYPE NUMBER OOR® (REFER TO WALL TYPES) # WALLTYPE SYMBOL NESED DOOR SCHED. DRAWING A.I 4 7 FIXTURE SCHEDULE FIXTURE: QTY. PROVIDED BY COI",I"IENTS: 8CASHDESK 8 I WOODWORKS MAPLE FINISH W/ PERMANENT F. F.5 F.5 F.5 F.5 _, . __i ADA LEDGE F'2 4'-0" W. PERIMETER SYNDICATE ASSEMBLY REQUIRED BY TGG WALL UNIT 3'-0" W. PERIMETER z14 q SYNDICATE ASSEMBLY REQUIRED BY TGC WALL UNIT F.3 4'-0" ACCESSORY 6 SYNDICATE - W/ HANGRAILS. ASSEMBLY REQUIRED BY TGC WALL UNIT - 8' H. 4'-0" WALL UNIT - 0 SYNDICATE ASSEMBLY REQUIRED BY TGC 4' H. F.4 FEATURE FLOOR UNIT 3 WOODWORKS MAPLE FINISH F.5 4'-0" FLOOR 35 WOODWORKS TGC TO ASSEMBLE / INSTALL GONDOLA ENDCAPS AND MIRRORS 3'-0" FLOOR 0 I-IOODWORKS TGC TO ASSEMBLE / INSTALL GONDOLA ENDCAPS AND MIRRORS F.6 SEATING UNITS) 7 CHAIRMASTERS F.7 HANDBAG FIXTURE 1 WOODWORKS F.8 T -STAND I ECONOGO F•g GRAPHIC FRAME 3 J.R.C. SWINGFRAME F 10 WINDOW DISPLAY 2 WOODWORKS 2 TIERED TABLES (MAPLE) FIXTURE F.I1 8 DUMP TABLE I ECONOGO NOT SHOWN ON PLAN NOTE: *ALL MILLWORK REFERENCED ABOVE TO BE SUPPLIED BY TENANT'S VENDOR(S)INSTALLED BY TENANT'S GENERAL CONTRACTOR 7011-211 LEASE LINE TO LEASE LINE - V.I.F.) .-n 'A }- 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA Q F.5 F.5 F.5 (F. E ` F.5 F.5 F.5 F.5 F.5 N F. F.5 F.5 F.5 F.5 _, . __i FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA N F.5 F.5 F.5 (F. E ` F.5 FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA u� N F.5 F.5 F.5 F.5 F.5 FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA u� N F.5 F.5 F.5 F.5 F.5 FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA Q F.5 F.5 F.5 F.5 F.5 F.5 F.5 F.5 F.5 FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA N F.5 F.5 F.5 F.5 F.5 FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA 4' GONDOLA N F.5 F.5 F.5 F.5 F.5 FIXTURE PLAN 104" = 11-011 NALL TYPES: ❑W NEW INTERIOR WALL CONSTRUCTION TO MATCH EXISTING; USE 25 GA. I 3-5/8" METAL STUDS AT 16" O/C W/ 1 LAYER OF 5/8" TYPE "X" GYP. BD. AT BOTH SIDES OF WALL TO UNDERSIDE OF EXISTING CEILING - FINISH WALLS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. 2 EXISTING INTERIOR DEMISING STUD WALL CONSTRUCTION TO REMAIN. G.C. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT EXPOSED SIDE OF WALL TIGHT TO DECK ABOVE (V.I.F.) TO MAINTAIN REQUIRED FIRE RATING (UL DESIGN # -U 465 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "TREZA" SIDE AS PER ROOM FINISH SCHEDULE 4 INTERIOR ELEVATIONS. ❑W EXISTING EXTERIOR WALL CONSTRUCTION 4 FINISH AT EXTERIOR SIDE TO 3 REMAIN. L.L. TO PROVIDE AND INSTALL 5/8" TYPE "X" GYP. BD. AT INTERIOR SIDE OF WALL TIGHT TO DECK ABOVE (IF NOT EXIST. - V.I.F.) TO CREATE REQUIRED FIRE RATING. T.G.G. TO PROVIDE 4 INSTALL 5/8" TYPE "X" GYP. BD. AS REQUIRED TO CREATE REQUIRED FIRE RATING FROM FLOOR TIGHT TO DECK ABOVE (V.I.F.) FINISH "NINE WEST" SIDE AS PER ROOM FINISH SCHEDULE* INTERIOR ELEVATIONS. ❑ W EXISTING PARTITION WALLS TO REMAIN - PREPARE FOR NEW FINISHES. 4 ❑W NEW INTERIOR WALL CONSTRUCTION; USE 25 GA. 3 5/8" MTs_. STUDS AT 16" 5 O.G. W/ 1 LAYER 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDE. ONLY - FINSIH WALL PER ROOM SCHEDULE 4 INTERIOR ELEVATIONS. D �- -JL A ITE ................. ................ 6 R B . •S 71..2Q1, 5 1 2 4 1 Ak ?�T F s� O 1 qh` OF „Y Cons 1$antS NINE WEST FRENCH) MOUNTAIN COMMONS LAKE GEORGE, NY 4 t space commission number 13-007(o number drawn RFV reviewed RFV ❑ preliminary a ■ final 11/10/06 ■ bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title FIXTURE PLAN FLOOR PLAN SCHEDULES sheet number 0 I 6 w z -j_ LU 0 U 1 l'3 co z F LU Z tu W x LL CORNER PANEL HANG RAILS W/ WATERFALLS ABOVE ACCESSORY SHELVING ACCE55ORY 111 ACCE55ORY 11 ACCE55ORY 4" V I NTL bHSC 'F" V I NT L t�H7C ( '� INTERIOR SIDE ELEVATION — SALES 7A 10" WHITE VINYL LOGO k2.0 SUPPLIED AND INSTALLED BY TENANT SIGN TYP. CONTRACTOR (TYP) VB F,3 411 VINYL BASE T.G.C. TO PROVIDE ELECT. TO CASHDESK - REFER TO DRAWING A3.0 r... �.. ..., .r. r /��� \ r�il�tl\Ir i\I _ II ♦ r t-T/\t'] t`IICI C /'TVC PERIMETER SHELVING COUNTS: (1) TOP SHELF PER UNIT (4) CENTER SHELVES PER UNIT ONE ANGLED (1) BASE SHELF PER UNIT (1) MAGNETIC SHELF LIP PER UNIT TOP OF UPRIGHT a 8'-0" BOLTED TO WALL m TOP, MIDDLE 4 BOTTOM (TYP) (PER LOCAL CODE REQUIREMENTS) PROVIDE F.R.T. BLKG. OR M FURRING A5 REOV. AS NOTED 4" V I NT L BASE %3� BACK WALL INTERIOR ELEVATION — SALES 1/4" = 1'-011 30" Ei I - 1 "Xl" L BRACKET SCREWS = C FLOOR GONDOLA SECTION 3/411 I- TO BE CUT SO AS NOT TO INTERIOR WITH LIGHT FIXTURE 3/4" F.R.T. BLKG (CONGEALED a QC IF P0551BLE AT NEW WALL5) o _ o FACE OF WALL UNDER -SHELF LIGHT - � LUco u NOTIFY J.R.G. FOR FIXTURE T.G.C. TO CONNECT BRIDGING TO JOIN .� C -CLIP N UPRIGHTS AS REQUIRED i.- APPROVAL/DISCUSSION 0 0 w A.F.F. T.G.G. TO INSTALL WALL (AT END OF: WALL — FIXTURE RUN) INSTALL SUPPLIED SHELVES (3'-0" OR 41-O" W. DASHED LINES INDICATE SHELVES) OUTLINE OF BASE SHELF B PLAN SECTION _ 1" = 1'-011 �- )OR GONDOLA DETAILS N BRACING UPRIGHTS AND tV BOTTOM, CHICKEN WIRE SUPPLIED N BY SHELVING VENDOR. A VERTICLE SECTION AT WALL 3/4" = 11-011 PERIMETER 4 FLC AS NOTED 4" V I NT L BASE %3� BACK WALL INTERIOR ELEVATION — SALES 1/4" = 1'-011 30" CORNER PANEL THERMOSTAT @ 54" A.F.F. 5A 2.c MIRROR BY T.G.C. — SEE 7/A2.0 TYP. F_ 7 P1 F.2 F. MOUNT @ 8" A.F.F. OR IN FIXTURE BASE DASHED LINE INDICATES OUTLINE OF CASHDESK INTERIOR SIDE ELEVATION — SALES 1/4" = 1'-01I INSTALL 'X' -BRACING ON END Ei I - CAPS OF ROLLING SECTIONS C FLOOR GONDOLA SECTION 3/411 I- w _ 3/4" F.R.T. BLKG (CONGEALED a QC IF P0551BLE AT NEW WALL5) o _ o FACE OF WALL FIXTURE BASE � LUco u NOTIFY J.R.G. FOR 06 T.G.C. TO CONNECT BRIDGING TO JOIN .� UPRIGHTS AS REQUIRED i.- APPROVAL/DISCUSSION OUTLINE OF 1 1/2TH. WING w A.F.F. T.G.G. TO INSTALL WALL (AT END OF: WALL — FIXTURE RUN) INSTALL SUPPLIED SHELVES (3'-0" OR 41-O" W. DASHED LINES INDICATE SHELVES) OUTLINE OF BASE SHELF B PLAN SECTION _ 1" = 1'-011 �- )OR GONDOLA DETAILS SECOND NOTCH FROM CORNER PANEL THERMOSTAT @ 54" A.F.F. 5A 2.c MIRROR BY T.G.C. — SEE 7/A2.0 TYP. F_ 7 P1 F.2 F. MOUNT @ 8" A.F.F. OR IN FIXTURE BASE DASHED LINE INDICATES OUTLINE OF CASHDESK INTERIOR SIDE ELEVATION — SALES 1/4" = 1'-01I INSTALL 'X' -BRACING ON END Ei I - CAPS OF ROLLING SECTIONS OUTLET BY T.G.G. preliminary I- w _ IF UNITS ARE TO BE GUT a QC bidding o _ o z z -1 FIXTURE BASE � LUco u NOTIFY J.R.G. FOR 06 z BRIDGING TO JOIN .� x i.- APPROVAL/DISCUSSION REQUIRED ABOVE 7'-0" w CORNER PANEL THERMOSTAT @ 54" A.F.F. 5A 2.c MIRROR BY T.G.C. — SEE 7/A2.0 TYP. F_ 7 P1 F.2 F. MOUNT @ 8" A.F.F. OR IN FIXTURE BASE DASHED LINE INDICATES OUTLINE OF CASHDESK INTERIOR SIDE ELEVATION — SALES 1/4" = 1'-01I INSTALL 'X' -BRACING ON END Ei EXI5TIN6 OR NEW CAPS OF ROLLING SECTIONS OUTLET BY T.G.G. preliminary O 18" FROM CLG. AND OR SPRINKLER HEADS IF UNITS ARE TO BE GUT a QC bidding MOUNT IN LL Q 0 m permit FIXTURE BASE ❑ 3/4" x 12" WOOD NOTIFY J.R.G. FOR p BRIDGING TO JOIN .� PARALLEL UNITS AS APPROVAL/DISCUSSION REQUIRED ABOVE 7'-0" A.F.F. T.G.G. TO INSTALL CHICKEN WIRE ON INSIDE WOOD SHELVES. BEGIN WITH SHELVING BASE CRO55 FACE. �- - SECOND NOTCH FROM BRACING UPRIGHTS AND 0 EXISTING 2' x 4' A.C.T, TOP SHELF (TYP.) CEILING PANELS — IN EXISTING GRID JG w z Lu o LU Lu z x FL N CORNER PANEL EXISTING 2' x 4' A.G.T. CEILING PANELS - IN EXISTING GRID LU -i LU z EXIST. GLAZING SYSTEM TO EXISTING STOREFRONT ENTRY VB REMAIN, G.C. TO CLEAN TO A DOORS TO REMAIN - G.C. TO 4" VINYL BASE "LIKE NEW" CONDITION CLEAN TO A "LIKE NEW" CONDITION TENANT'S GENERAL CONTRACTOR TO CUT DOWN STOCK UNITS IF REQUIRED FOR PROPER CLEARANCES. SHELVING AT EVERY SEVENTH i SLOT (TYP.) (14" O.C.) TGG TO USE 3 BACK TO BACK I CLIPS PER UPRIGHT WHEN ASSEMBLING SHELVES CHICKEN WIRE MESH ON BACK. T.G.G. TO TRIM FOR CLEAN EDGE. SLOTTED VERTICAL SUPPORT NOT TO SCALE 4 INTERIOR ENTRY ELEVATION — SALES 11411 EXISTING DEMISING I^lA.L_ 1/4" x 18" W. x 60" H. CLEAR MIRROR ABG #6M-1860 BY T.G.G. APPLY TO GYP. BD. WITH MIRROR MASTIC. CAULK VERTICAL E06ES WITH ULTRA-GLEAR SILICONE. BRUSHED ALUMINUM 'J' -CHANNEL @ TOP AND BOTTOM OF MIRROR. SECURE TO DEMISING WALL. SUPPLIED AND INSTALLED BY T.G.C. 18" 12" A.F.F. �I RELOCATED, Ei EXI5TIN6 OR NEW j OUTLET BY T.G.G. preliminary O POSTS. SECURE WITH BACK IF UNITS ARE TO BE GUT a QC bidding MOUNT IN LL Q 0 m permit FIXTURE BASE ❑ TO BACK CLIPS. NOTIFY J.R.G. FOR p APPROVAL/DISCUSSION WOOD SHELVES. BEGIN WITH SHELVING BASE CRO55 - SECOND NOTCH FROM BRACING UPRIGHTS AND BOTTOM, CHICKEN WIRE SUPPLIED BY SHELVING VENDOR. ✓'�1a� e e T.G.C. TO USE VENDOR SUPPLIED SCREWS. NO DRYWALL SCREWS WHEN FASTENING UNITS BACK TO BACK. i" x 4" WOOD BASE (TYP.) (RELEASE ORDER FROM EXCALIBUR AT 603.74(o.6200) ( fO 1 STOCKROOM SHELVING NOT TO SCALE 4 INTERIOR ENTRY ELEVATION — SALES 11411 EXISTING DEMISING I^lA.L_ 1/4" x 18" W. x 60" H. CLEAR MIRROR ABG #6M-1860 BY T.G.G. APPLY TO GYP. BD. WITH MIRROR MASTIC. CAULK VERTICAL E06ES WITH ULTRA-GLEAR SILICONE. BRUSHED ALUMINUM 'J' -CHANNEL @ TOP AND BOTTOM OF MIRROR. SECURE TO DEMISING WALL. SUPPLIED AND INSTALLED BY T.G.C. 18" 12" A.F.F. �I RELOCATED, Ei EXI5TIN6 OR NEW j OUTLET BY T.G.G. preliminary O final i _ Qq _ I a QC bidding MOUNT IN LL Q 0 m permit FIXTURE BASE ❑ revisions AS ALTERNATE p 4" VINYL BASE 0 0 i v ca MIRROR DETAIL NOT TO SCALE 41-011 TGG TO MOUNT (5) SHELVES ABOVE THE MANAGER'S DESK C a r RF ,/ reviewed RFV XXH EJ preliminary ■ final i _ Qq _ I ® bidding 11/10/06 LL Q 0 m permit 11/10/06 ❑ revisions -- EXCALIBUR DESK (5) ADJUSTABLE SHELVES (TYP) A610 5Y5TEM LEAD5 NSTALLED BY T.G.G. AT 60" A.F.F. QUAD OUTLET AT 50" A.F.F. TGC TO SECURE SAFE TO FLOOR V.I.F. PHONE / DATA LINES —____/ DUPLEX OUTLET MANGER'S DESK DETAIL (IF NOT EXISTING) ARCHITECT' ................ 1 ConsVItants NINE WEST FRENCH FOUNTAIN COMMON5 LAKE GEORGE, NY space commission number drawn RF ,/ reviewed RFV ❑ preliminary ■ final 11/10/06 ® bidding 11/10/06 ® permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORD WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title INTERIOR ELEVATIONS AN AI D DET L5 m sheet number e 1 � GENERAL NOTES: I. ALL GYP. BD. CEILINGS TO BE PAINTED PI (FLAT FINISH). ALL DIFFUSERS, ETC. TO BE PAINTED TO MATCH CEILING FINISH 2. ALL SWITCHES AND OUTLET TRIM PLATES TO BE WHITE IN COLOR. PAINT TRIM PLATES TO MATCH ADJACENT WALL. 3. IF THERE ARE ANY DISCREPANCIES BETWEEN THIS DRAWING AND M.E.P. DRAWINGS CONTACT THE ARCHITECT/ENGINEER IMMEDIATELY (PRIOR TO AWARD OF CONTRACT) 4. TGC IS RESPONSIBLE FOR SUPPLYING AND INSTALLING ALL MOUNTING EQUIPMENT REQUIRED FOR PROPER INSTALLATION OF STOCKROOM LIGHTING. IE: SURFACE MOUNT OR CHAIN HUNG. 5. TGC SHALL DIRECT ADJUSTIBLE LIGHTS ONTO DISPLAY FIXTURES AS ARROWS INDICATE 6, EXISTING 2' X 4' CEILING GRID TO REMAIN; PROVIDE NEW 2x4 ACT PANELS TO SALES; STOCKROOM - NEW 2x4 ACT. SYSTEM. 7. TGC TO SUPPLY AND INSTALL FIRE RATED PLYWOOD PANELS PAINTED P1 WHITE (PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT) 8. RECESSED LIGHT FIXTURES SHALL BE INDEPENDANTLY SUPPORTED WITH HANGER WIRE q. TRACK FIXTURES SHALL BE INDEPENDANTLY SUPPORTED WITH HANGER WIRE EVERY 4'-0" MAX. 10. SPRINKLER HEADS AT ALL DRYWALL STOREFRONT SOFFITS SHALL BE FULLY CONCEALED TYPE HEADS WITH FACTORY PAINTED COVERS. 11. SPRINKLER HEADS WITHIN SALES AREA OR OTHER PUBLIC SPACE WITH A LAY -IN CEILING SHALL BE FULLY CONCEALED (PENDANT TYPE HEADS ARE NOT PERMITTED). REFER TO LANDLORDS FIRE PROTECTION REQUIREMENTS. NOTES: REFER TO SPEET T.1 WORK PURCNACE SC1-IEDULE FOR ALL TENANT SUPPLIED ITEMS AS WELL AS VENDOR INFORMATION. SY11BOL LEGE=ND -7 CALL FOR AID SYSTEM T D TELEPHONE / DATA V (ONE BOX) V DATA LINE V TELEPHONE +3 3 -WAY SWITCH QUADPLEX OUTLET D DEDICATED QUADPLEX DUPLEX OUTLETC EX NEVI D DEDICATED DUPLEX OT—STAT RELOGATE T—STAT IF REG -D. FE FIRE EXTINGUISHER �]B BUZZER W/ TRANSFORMER El PUSH BUTTON (MOUNT 54" A.F.F.) EMERGENCY FIXTURE w/ BATTERY BACKUP WN OR WH WATER HEATER (BY LL) OFIXTURE DETAIL ( > _ ELEVATION EX - EXISTING REL = RELOCATED LAMP 100 C.F.M. EXHAUST FAN OS SPEAKER NOTE: PROVIDE POWER AND DATA AT MANAGERS DESK AND CASHDESK. ALL OTHER ELECTRCAL COMPONENTS ARE NEW BY LANDLORD UNLESS NOTED EXISTING. PROVIDE PERMITS AS REQUIRED KEY E EXISTING FIXTURE TO REMAIN R EXISTING FIXTURE TO BE RELOCATED TR NEW TRACK AND HEADS NEW NEW LIGHT FIXTURES - SEE LIGHT FIXTURE SCHEDULE T.G.G. TO CLEAN AND RELAMP EXISTING FIXTURES (REBALLAST C L I GPT F- I XT U R E SCP E D U L 1.... AS REQ'D V.I.F.). CONTACT WEIDENBACH-BROWN q14 -712-432q PE QTY. CODE MANUFACTURER CATALOG DESCRIPTION WATT LAMP EXIST. TO � L='J EXISTING EMERGENCY EXIT REMAIN SIGN TO REMAIN. EXIST. TO EXISTING TWIN HEAD EMERG. FIXTURE - SUPPLIED W/ FIXTURE REMAIP' Y WALL MTD TO REMAIN EXIST, 30 EX. EXISTING 2X4 FLUORESCENT LIGHT I REL. - - FIXTURE TO REMAIN - UNLESS BI NOTED OTHERWISE 52 EXIST. TRO, _ EXISTING TRACK FIXTURE TO REMAIN. I EXIST. EXISTING FAN/LIGHT COMBO TO REMAIN. 14 NEW JESCO SG5-28 UNDER SHELF FLUORESCENT LIGHT HIRE 28 CONTINUOUS q NEW rim e JESCO SG5-21 -SEE ELECTRICAL DRAWINGS 21 INDICATES CEILING SUPPLY DIFFUSERS - SEE MECH. DRAWINGS A INDICATES LAY -IN TYPE PLENUM RETURN AIR GRILLES - SEE MECH. DRAWINGS * SEE ELECTRICAL PLANS FOR EXIT 4 EMERGENCY VERIFY EXISTING LIGHTING LOCATIONS EXISTING 2X4 ACT CEILING TO REMAIN AT q'-0 A.F.F.- REPAIR OR RFPI -Ae F= CFII INr. PAWFI _S NOTE ELECTRICAL ""' `r' r"' "� '•• • "�"" "� PANEL CALCULATOR CONTRACTOR SHALL (STOCKROOM) ETC. PROVIDE ALL RACEWAYS ..... .. .......... OR CONDUITS W/ PULLWIRE -- - - - -- _ _ - - - _ _ ----- _--- AND JACKS AS REQUIRED. ----- --- --- ___ — — --JLj Jim---- �— - -- u ----J ---- — — JL----- —J-------—JL--------J'---------- .JL ____. -------'L_ - _ VJ/ L-------- JL-- ----- —L------- L -- --- --- Ju -- ---J ----- ---J ----- ---Ju COORDINATE WITH TENANT T PHONE BOARD II 4684 REGISTER 1 E) PDT CRADLE (MASTER) F- - ---- E,--- �-- E DEDICATED) E) T - - --- E�--- ---------- ---- - - -- ---T----- - - ----------_..<` -- --- j -- ------ --- ----- --------1i it ----- --- ----- -- ---- - J PHONE LINE , II D PRINTER MODEM PHONE - -- -,-- DASHED LINES INDICATE RJ41S CONFIGURATION JACK DASHED LINES INDICATE - SALES CONFIGURATION OF AREA EXIS ING CEILING FANS TO STORE PHONE FIXTURING BELOW (TYP.) E) 100 REMAIN. - TYP. --- OF FIXTURING J RAI ( I -------- --- T -- --- -1 ---- -----i -- I t ----- ---T- - ---- ---T----- --- ---- - L ----- - ; BELOW (TYP.) --- ---- -- — — -- I — * REGISTER IS PLUGGED INTO DEDICATED OUTLET. PHONE **CALCULATOR, PDT CRADLE, PRINTER AND MONITOR PLUGGED INTO QUADPLEX OR SURGE PROTECTOR REGISTER COMMUNICATION DIAGRAM STS SYSTEM MODIFY AS REQUIRED FOR MULTIPLE REGISTERS EXISTING 2X4 AC CEILING TO REM, q'-0"A.F.F.- REP, REPLACE GEILINC. IF DISCOLORED C DAMAGED - TYP EXISTING ELECTF EQUIPMENT "TO R MANAGERS DESK EXISTING CEILING LIGHTING TO REr EXISTING TOILET EXISTING MECHAI 1 REFLECTED CEILING PLAN 3. 1/4" = 1'-0° PLA� NOR- EXISTING TRACK TYPE LIGHT FIXTURES SUPPLIED BY LIGHTING SUPPLIER 4 INSTALLED BY ELECTRICAL CONTRACTOR (TYP.) RELOCATED EXIST, 2X4 LIGHT FIXTURE ARCHITEGT' Comitants NINE WEST FRENCH FOUNTAIN COMMONS LAKE GEORGE, NY space #3 commission 13 — 00%�O number drawn RFV reviewed RFV ❑ preliminary IB final 11/10/06 ■ bidding 11/10/06 ■ permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title REFLECTED CEILING PLAN sheet number 1430 e CONTINUOUS CONDUIT IS TO BE RUN IN WALLS * EXTEND TO ABOVE THE FINISHED CEILINGS (MIN.) COMPLY WITH ADDITIONAL REQUIREMENTS AS PER CODE. INDICATES ACOUSTICAL LAY—IN CEILING SYSTEM INDICATES WALL CONSTRUCTION — SEE 1/A1.1 * REFER TO ALL ARCHITECTURAL DRAWINGS FOR FURTHER DETAILS AND COORDINATION RUN CONDUIT IN FLOOR SAW CUT CHANNELS TO BELOW FREESTANDING FIXTURES THROUGH OUT SALES AREA AS INDICATED ON 1/A1.1 4 i/A6.0. INDICATES FREESTANDING CASHWRAPS PROVIDE 4 INSTALL FLUSH MOUNTED STYLE 2 GANG FLOOR BOXES WITH BRA COVER PLATE — SEE FLOOR BOX SPECIFICATIONS THIS SHEET.--__ GENERAL CONTRACTOR TO BE RESPONSIBLE FOR SAW CUTTING OF CHANNEL IN EXISTING CONCRETE SLAB FOR RUNNING OF TELECOMMUNICATIONS ELECTRICAL CONDUITS, RE—FILL SAW CUT WITH 3,000 P51 GONG. WHEN FINISHED. INDICATES EXISTING VARIESt, COMPACTED SOIL CONDITION UNDER SLAB (V.I.F.) INDICATES CONDUIT FOR ELECTRICAL WIRING d TELECOMMUNICATIONS WIRING. SEE BELOW FOR SPECIFIC REQUIREMENTS AT INDIVIDUAL FIXTURES. CASHWRAP: I` EMT UNDERSLAB (1) FOR ELECTRIC (1) FOR SIGNAL 2 TYPICAL TRENCH DETAIL 4.0 1" = 1"-0" ELECTRIC NOTES: I, ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, STATE AND LOCAL CODE, OSHA AND PROVENCE OF THE LEASE. 2. ALL WIRING SHALL BE IN CONDUIT AS NECESSARY INCLUDING ABOVE CEILING, CONGEALED IN THE SALES ROOM. WIRING UNDER FLOOR OR ABOVE ROOF SHALL BE IN HEAVY WEIGHT GALVANIZED CONDUIT AS REQUIRED. ALL EQUIPMENT EXPOSED TO WEATHER SHALL BE WATERPROOFED. B. CONDUCTORS SHALL BE COPPER : TYPE THW OR BETTER: NO 12 AWG MINIMUM. INCANDESCENT LIGHTING SHALL BE 150 DEGREES C. RATED. 4. MATERIALS SHALL BE 30AMP: COMMERCIAL SPECIFICATION GRADE 5.INCANDESCENT AND FLUORESCENT LIGHTING ON RETAIL FLOOR AND STOCKROOM AREA SHALL BE SUPPLIED BY TENANT, INSTALLED BY G.G. UNLESS NOTED OTHERWISE. 6. TRACK LIGHTING TO BE SUPPLIED BY TENANT INSTALLED BY GENERAL CONTRACTORS AS PER REFLECTED CEILING PLAN, 7. EXIT SIGNS AND EMERGENCY LIGHTS TO BE FURN15PED AND INSTALLED BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. B. EXISTING DUPLEX OUTLETS NOT AFFECTED BY DEMOLITION ARE TO REMAIN. 9. ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATIONS, WITH G.C., PRIOR TO INSTALLATION OF OUTLETS, EMERGENCY LIGHTS, AND TRACK. PARTITION / ELECTRIC LEGEND NEW 110v DUPLEX ELECTRIC OUTLET NEW 110v DOUBLE DUPLEX 2 ELECTRIC OUTLET SC SEPERATE CIRCUIT N NEW R RELOCATED u1u VERIFY OUTLET LOCATION IN FIELD PLACE NEW OUTLET IF EXISTING IS NOT IN VICINITY. APPROX. 20' O.G. O JUNCTION BOX FOR FIXTURE FLUORESCENT LIGHTING 011111111 DATA LINE E DPHONE LINE 3 TYPICAL CONDUIT RUN SECTION INAI4. 3/4" = 1'-0" EXISTING DOOR CHIM SWITCH TO REMAIN. EXISTING STOREFRONT GLAZING SYSTEM T REMAIN; T.G.C. TO CLEAN TO A "LIKE NEW" CONDITION EXISTING STOREFRONT GLASS DOORS TO REMAIN; T.G.C. TO CLEAN TO A "LIKE NEW" CONDITION ARCHI�'ECT .............. ................. Consult MINE WEST FRENCH; MOUNTAIN COMMONS LAKE GEORGE, NY space #3 commission 13-007 (o number drawn RFV reviewed RFV ❑ preliminary final 11/10/06 ® bidding 11/10/06 ■ permit 11/10/06 ❑ revisions THESE DRAWINGS ARE THE PROPERTY OF ROBERT F. VANNEY AND ARE NOT TO BE TRANSFERRED TO ANY PARTY OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF ROBERT F. VANNEY. THESE DRAWINGS WERE PREPARED FOR THIS SPECIFIC PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. (C) 2006 COPYRIGHT ROBERT F. VANNEY drawing title sheet number A,4.0