2012-081 TOWN OF QUEENSBURY woito 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120081 Application Number: A20120081 Tax Map No: 523400-297-007-0001-026-000-0000 Permission is hereby granted to: STEPHEN RICHARDS For property located at: 65 HICKS Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: STEPHEN RICHARDS Garage Detached $4,000.00 DEBORAH RICHARDS 65 HICKS Rd Total Value $4,000.00 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2012-081 HOLD, needs Area Variance (constitutes a second garage on parcel) See C.Brown, ZA letter dated March 2, 2012 768 sq ft detached garage $115.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,April 26,2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o sbury• Thu s■a,,April 26,2012 SIGNED BY t f I for the Town of Queensbury. Director of Building&Co.e Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120081 Date Issued: Tuesday, July 17, 2012 This is to certify that work requested to be done as shown by Permit Number P20120081 has been completed. Location: 65 HICKS Rd Tax Map Number: 523400-297-007-0001-026-000-0000 Owner: STEPHEN RICHARDS Applicant: STEPHEN RICHARDS This structure may be occupied as a: Garage Detached By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building& e En ement or Zoning Board of Appeals. OFFICE USE ONLY .,x"7.7^I-� 1 I Q. TAX MAP NO. PERMIT NO. 40/16 -A - 1 r w:,a FEE PAID lI J ✓ BLDG. &CODES APPROV•L 4 , • Fq BUILD'F, UEEIV`e ACCESSORY STRUCTURE B DING PERMIT APP ARY Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No, 3 entitled Accessory Structures- Sheds/Fences, • A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS, APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. CD �C�OWNER: `INSTALLER/BUILDER: StL_� ADDRESS: (Q N\CAS ��(� Q\ It),( ADDRESS: PHONE NOS. \(;-)Ar. - ~)a i PHONE NOS. S1=i`C`.t LOCATION OF PROPERTY: \.`. f.A\NS' l>C\.-\ SUBDIVISION NAME: `\ I • LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: l HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑YES .XNO IF S0,INDICATE APPLICATION NO.AND DATE OF APPROVAL: ESTIMATED COST OF CONSTRUCTION: $`"�M• vL ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES, PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: ��.1.k7"(:1-C 't11.4v\ .( P HONE: #3')-(> ST we PROPOSED PROPOSED CONSTRUCTION FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ. FT, SQ, FT. FT.&IN. OPEN PORCH DECK I 3 SEASON,COVERED OR ENCLOSED PORCH' ti - BOATHOUSE BOATHOUSE WITH SUNDECK I DOCK • SHED POLE BARN DETACHED GARAGE(N0.OF CARS:) d7(0<e, �C -7“ OTHER ACCESSORY STRUCTURE: 1 *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIOI REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested Code Compliance and Informational Sheet for Permit Use Queensbury Dept. of Community Development Project for: &� Permit No. 2012 Ce( Applicant Name:Jl` • Zoning Administrator 282 7 I-2 (, M r-KUVED Tax Map No. / �,� Application Lot # House # CL 5 9�'`�l/ • road, street I 'r, 111 Lot Size: l, ?CP A'e-""'l — Vain Administrator Mobile Home Park: _TG'__ O QUEENSBURY Business Plaza: Planned Unit Dev. Subdivision: Phase/Section Effective Year Zoning Designation Zoning Ordinance Prior to 1967, July 10 Subject to current setback requirements at time of development. Section 179-20-10,B Subsequent to Development of lots within subdivisions subsequent to July 10, 1967 July 10, 1967 shall use the setback requirements in place at the time of the approval of the subdivision. 1967 1982, June 1 1 1988, September 19 Corner lot rule Prior to Nov. 23, 1992 approved subdivisions * (see note on back of form) /2002, April 9 t/ 2009, May 12 /vlbQ, Road Name Setbacks Existing Required — Proposed T Difference Front 1 36 6,6 If Plus Front 2 Side 1 Side 2 j c?-50 - /6U ft- Rear 1 _ f. tQ Rear 2 Shoreline Travel Corridor Overlay Zone Buffer Yes No meets depth,width, &square footage requirements preexisting, nonconforming lot with proper setbacks required frontage on public road has required off-street parking permeable area is adequate (Requirement is %) building does not exceed maximum height (Max. ft.) Is lot in a Flood Zone? Floor Area Ratio worksheet required? Zone: WR-1 A Town of Queensbury Code Compliance and Informational Sheet for Permit Use lC Queensbury Dept. of Community Development a CI nh W 0 Z * Corner Lot Information for Subdivisions Approved Prior to November 23, 1992 Section 179-30.1 which requires front yard setbacks on both roads for a corner lot was not enacted until November 23,1992. Therefore, prior to November 23, 1992 parcels within approved subdivisions have one (1) front yard, two (2) side yards, and one (1) rear yard setback. Review Type File No. Action Resolution Date Zoning Board of Ap•eats Planning Board Town Board — • Check List Yes No Recreation Fee Paid Engineering Fee Paid Site Plan Maps on Hie_ _ J Subdivision Mylar Signed and Filed with County Application appears to conform to the requirements of Section(s) of the local Town Code: Application requires additional review for the following: Zoning Board of Appeals Planning Board Town Board of Health Town Board for Mobile Home Outside of a Mobile Home Park Other Revi i - by Sta - r Date Notes Town of Queensbury Page 1 of 1 4_ 3aaI.b.r length always-30Ot4st `w 0 3'Oft The Town of Queensbury does not warrant the correctness or accuracy of this data or assume any responsibility for any explicit or implied uses. JTown of Queensbury -2j . 742 Bay Road Queensbury,NY. 12804-5902 http://gby2svr/GIS/printdis.asp 3/2/2012 RPS Information Page 1 of 3 RPS Property Description Report itpffaiwir 297.7-1-26 * 65 Hicks Parcel Information for ROLL YEAR 2012: Parcel Location Acres Property Status School District Assessed Assessed Class Land Val Total Val 297.7-1- 65 Hicks 1.26 1 Family A Queensbury 30,800.00 138,400.00 26 Res Un.fr.sd I IP, If Image Date: 6/28/2004 Sales: Sale Net Sale Sale Cond. Arms Land Tot. Value Date Sale Price Price Book Page Type Code Len. TOSe TOS Prior Owner 11-15-10 160,000.00 160,000.00 4126 309 3 J 1 30,800.00 138,400.00 Rich,Jeannine Owner information: Owner Owner Address P.O. Box Owner Address Line 3 Deborah Richards 65 Hicks Rd Queensbury NY 12804 Stephen Richards 65 Hicks Rd Queensbury NY 12804 Site Information: http://gby2svr/GIS/RPS_Info.asp?RPT=SALES 3/2/2012 RPS Information Page 2 of 3 r Site Nbhd Code Sewer Water Utilities Site Nbhd Nbhd Road Entry Zoning Desire Type Rating Type Type Code 106- 1 2 2 2 2 2 2 3 1 MDR Rt9L,Eside,Sunn Land Information: Site# Land # Type Front Depth Acres Su Ft 1 1 01-Primary 165 200 0 0 1 2 04-Residual 0 0 0.5 0 Building Information: Site Bldg # Ext Wall Yr # # # 1/2 # # Style Stories Mat Built Kit. Baths Baths Bedrm Firepl 1 01 1 03 1994 1 2 0 2 0 Site# Heat Type Fuel Type Central Air Bsmt Type Overall Cond Constr Grade SFLA 1 3 2 0 4 3 C 1256 Improvements Information: Site Struct bode Dim Dim M2. Constr Overall Yr 1 2 FT Grade Cond Built 1 FC1-Shed-machine 10 10 0 1 C 3 1994 1 FC1-Shed-machine 10 8 0 1 C 3 1900 1 RG 1-Gar-1.0 att 24 24 0 1 C 3 1994 1 RP 1-Porch- 5 4 0 1 C 3 1994 open/deck RP 1-Porch- 1 13 12 0 1 C 3 2003 open/deck Special Districts Information: Special District Units Percent EM001-Emergency 0 0 medical FP007-Fire protection 0 0 LB001-Crandall library 0 0 dst RPS Building Permit Information: http://gby2svr/GIS/RPS_Info.asp?RPT=SALES 3/2/2012 RPS Information Page 3 of 3 Permit Number Permit Date Permit Use Cost Estimate P96-636 10-16-96 Roof over deck 2,000.00 P95-483 08-22-95 Deck 1,900.00 P94-536 Single Family Dwelling 0.00 P20030248 05-07-03 Deck 1,000.00 The RPS codes used in this report are defined here Need Help printing this report? The information in the RPS database is maintained by the Town of Queensbury Assessors Office http://gby2svr/GIS/RPS_Info.asp?RPT=SALES 3/2/2012 Building Permit No. Final Approved Plans By Approval of the Zoning Board of Appeals and final sign-off by C. Brown, •Zoning Administrator Applicant: Stephen H. Richards File No. Area Variance No. 14-2012 Project Location: 65 Hicks Road Applicants) Stephen H. Richards Area Variance No 14-2012 Owner(s) Stephen H. Richards SEQRA Type II Agent(s) N/A Lot Size 1.26 Acre(s) Location 65 Hicks Road Zoning MDR-Moderate Density Residential Tax Id No 297.7-1-26 Ordinance Reference 179-5-050D Cross Ref BP 2012-081 detached Warren County Referral Yes garage; BP 2003-248 deck; BP 94-536 SFD Public Hearing April 18, 2012 Project Description: Applicant proposes construction of a 768 sq. ft. second garage on a 1.26 acre parcel. Relief requested from number of allowable garages on a parcel. Further, applicant seeks rear yard setback relief from the MDR zone. Applicant Copy _Variance File Copy _Building Permit Copy B. Frank, Code Compliance Officer Copy Zoning Board of Appeals - Record of Resolution Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761 -8238 Steven Jackoski, Chairman Roy Urrico, Secretary TO: Stephen H. Richards PROJECT FOR: Stephen H. Richards 65 Hicks Road 65 Hicks Road Queensbury, NY 12804 The Queensbury Zoning Board of Appeals has reviewed the following request at the below stated meeting and has resolved the following: Area Variance No. 14-2012 Stephen H. Richards Meeting Date: Wednesday, April 18, 2012 Approved X MOTION TO APPROVE AREA VARIANCE NO. 14-2012 STEPHEN H. RICHARDS, Introduced by Brian Clements who moved for its adoption, seconded by Ronald Kuhl: 65 Hicks Road. The applicant proposes construction of a 768 square foot second garage and a 1 .26 acre parcel. The relief required is from the number of allowable garages on a parcel as per Section 179-5-020D and relief requested from the rear yard setback requirements as per Section 179-3-040. In making the determination the Board should consider whether an undesirable change will be produced in the character of the neighborhood or a detriment to nearby properties will be created by granting of this Area Variance. Minor impacts may be anticipated. Number Two, whether the benefit sought by the applicant can be achieved by some other method feasible for the applicant to pursue other than an Area Variance. There are limited feasible alternatives. Number Three, whether the requested Area Variance is substantial. It may be considered moderate. Number Four, whether the proposed variance will have an adverse effect or impact on the physical or environmental conditions in the neighborhood? Minor impacts may be anticipated. Also the applicant has agreed to remove Page 1 of 2 Approval of the application means that the applicant can now apply for a Building Permit unless your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review by the Queensbury Planning Board.) Zoning Board of Appeals - Record of Resolution Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238 Continued ZBA Resolution Area Variance No. 14-2012, Stephen H. Richards ZBA Meeting Date: Wed., April 18, 2012 one shed on their property. Whether the alleged difficulty is self-created. The difficulty may be considered self-created. I move for approval. The shed being removed is the one closest to the pond. Duly adopted this 18t day of April, 2012, by the following vote: AYES: Mr. Underwood, Mrs. Hunt, Mr. Kuhl, Mr. Clements NOES: Mr. Garrand, Mr. Urrico, Mr. Jackoski Sincerely, Steven Jackoski, Chairman Queensbury Zoning Board of Appeals SJ/sh The variance approval is valid for one (1 ) year from the date of approval. You may request an extension of approval before the one (1 ) year time frame has expired. See section 179-14-090 Final, approved plans in compliance with this variance must be submitted to the Community Development Department before any further review by the Zoning Administrator or Building & Codes personnel. Subsequent issuance of further permits, including building permits are dependent on receipt. Page 2 of 2 Approval of the application means that the applicant can now apply for a Building Permit unless your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review by the Queensbury Planning Board.) Area Variance Revised June 2009 Site Development Data r>}}4,„,p 't't tom"''+j ,ea].7,- ,, v.... .' '3'+j�fi ,,,w, 4.1 f- .5.` O r -. ,` .., ',4 ..�if .NF,& '�.:�` a`^��Sw°'� ”-s` ."`rk,�_.. .;'`t .tE ,r .f,� . ., r.."3,,:" 3"c ._�- ,'ff i A. Building footprint . //as.� C1 B. Detached Garage C. Accessory Structure(s) I.Sh.{° le 'to ' ICO s a . ��.ca.-. 10'y / �U s T. / D. Paved, gravel or other hard surfaced area ,)te' K 30' -70,16 SS¢ "ti —, r, E. Porches / Decks Para' S'?4q' a0 s;R. ^ ,� �ortl.. 13 ' y1a ' 15(a SF. r' 7& F. Other ArdAt,--z0( 60-A. e ag/A-a,t �� 7 i� 5'7 6..rF; G. Total Non-Permeable [Add A-F] H. Parcel Area [43,560 sq. ft. /acre] /,a 4, .r3 sy,8g'5, (e6 sf I. Percentage of Impermeable Area of Site [I=G/H] / �- r. '), / /c Setback Requirements K' R f � ufi C ys... y } , : Front [1] 3o-14. Igo e. IRo Front [2] Shoreline Side Yard [1] c_5 -P-- �s Side Yard [2] d-5J .. ' { /60 Rear Yard [1] 30 Z``� &O 3 �P _ 10 r-( Rear Yard [2] Travel Corridor T- Height [max] 1 r--- Permeability No. of parking spaces I Town of Queensbury•Zoning Office• 742 Bay Road • Queensbury, NY 12804 • 518-761-8238 2 . Map Stephen H. Richards AV - 2012 65 Hicks Road second garage on parcel of 'lands of R„ 0-,b,. ert ,--.&,.. Jeannine Rich Ri 1 Town Of Qtmensbury * Warren County * New York Scae! r = )< - March 3, 1995 50' • - ,s, oF N6-14, Slirvry oricl hlIp by Wayne R. Raytnonot. c;f9 -011)1*-7N( Licensed Land Surveyor s Glens Falls et Wevertown . N - .,.. mor■-• . ••• Illtpr •ND S‘) SURVEY UPDATED BY DARRAH LAIVD SURVEMVG DARRAH LAND SURVEYING OWNS THE RECORDS OF WAYNE R.RA YMOIVD. THE PURPOSED OF Th7S MAP IS TO SHOW THE EXISTING AND PROPOSED LI1PROVEMENTS SINCE THE PRIOR DATE OF TIES MAP Donald C Darrah,PLS No.50552 Date: 3 f s Ira_ LANDS N/F OF NORMAN & DORIS WEBB L.324-P. 193 +-50.01--. S-82%441-151-E 220.00' 0 10.0' 1 WItil '7'E if R Oti•gd 250'--OOP 1 0 Oil ■III N. OPEN DECK EIVCZOSED PCITCH 1 ...... ...,a 1 Lc) 48.7:_ovh44 47) 3+0,441 .-.I IN "' 96r. drivs > < i i :tory -- --. 1 houas 30.2' La 1 AbA ce) 1 L.L. ; Z 0 t egilliate --) \ CS "••• 6+400 I 1 .26:t AC:\ v„ ‘,0 0 L.M- . , or\ cc c it oN \\Nj ,\ 1;:\IWI rof‘tAto orj L, ■,..)\ V tik)btj "V o ----": L,.. WET AREA N%\ 4 Mir\ , e .01?It .... z ( ----........._ ,L "It .z1 ----------------------------------------- ■wwwwwwwwwwwwww wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww �_. ■wwwwwwwwwn■� wwwwwwwwr� wwwww wwwwwww■ -_ �,� wwwwwwwwwww wwwwwwwwwl�wwwww wwwwwww: ■wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww• FRONT RIGHT ■--------------wwwww---------------------U wwwww■-----■ •••••••�wwwwwwwl.wwww------ wwww• -i �O - - =--- Zwww •wwwwwww --wwwww wwwwwwwwww ■www�wwwwwwww---wwwwwwwwwwwwwwwwww ,j 1 11I 1 I IJ ` ` t� llrll ' f1111111t [IIIIIrI `III iii IlIIlIIIIIIIrI IIrIIIIII 1 1 1 I l 1 1 [ 1 1 1 � `�� 1 1 1 1 1 1 1 1 1 _1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1_ 11 1 1 1 1 1 I 1 I I 1 1 1 I I I I 1 1 1 I I I _L 1 1 1 _1 I l I 1 1 1 1 _1 1 1 1 1 1 I l 1 1 I I 1 1 1 1 1 1 1 I LEFT - - - - - _ REAR TOWN OF QUEENSBURY IT* 742 Bay Road, Queensbury, NY 12804-5902 518-761-8201 March 2,2012 Stephen and Deborah Richards 65 Hicks Road Queensbury,NY 12804 RE: BP 2012-081: 768 sq.ft. detached garage Tax Map No. 297.7-1-26 65 Hicks Road Dear Mr. Richards: I am writing to you in response to my review of your building permit plans submitted depicting the proposed construction of a 768 sq. ft. detached garage and to document our past conversations and the conversations between you and Keith Oborne of my office. Upon review of the plans submitted to this office, I find that an Area Variance will be necessary in order for you to construct the project as planned. Specifically, the detached garage proposed is considered to be a second garage as you have an existing attached garage on the property; a variance is needed for a second such structure. In addition, you will need a variance for rear yard setback relief from the MDR zone. The minimum rear yard setback requirement is 30 ft. and your plan shows the proposed garage to be setback at 10 ft. I understand that you are preparing the necessary applications. Please note our established submittal deadlines when compiling your application materials. Should you have any questions regarding the above comments, please do not hesitate to contact this office. Sincerely, Town of Queensbury Craig Brown Zoning Administrator CB/sh L:\Craig Brown\2012 Letters\BP 2012-081 Denial Richards 3 2_12.doc "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO LIVE" SETTLED 1763 Foundation Inspection Report ( —)iit-'— Office No. (518) 761-8256 Date Inspection reque -ce. d: c7 1 7' Queensbury Building&Code Enforcement Arrive: (. I-1O; 1407P t-part: !!5-4) : 1 '.m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ` NAME: 'L G�� t'�!-'-1::)//-45 P ' I T#: 1 Z - U LOCATION: L; S 1� ' P-C'/\ t- I SPECT ON: / 9/ r7- TYPE OF STRUCTURE: (j_,,z .,,, f Comments Y N N/A Footings �, , ` - - Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. _ Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I L:\Building &Codes Forms\8uilding&Codes\Inspection Fonns\Foundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing ! Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: I .( am/pm Depart: amt 742 Bay Road, Queensbury, NY 12804 Inspectors Initials: �i NAME: /S.% ( tioN +") S PERMIT#: _ C) LOCATION: S E,c 145 12-414-D INSPECT ON: C/z y/ TYPE OF STRUCTURE: 7 Y �i✓ COMMENTS: iikra ming t/ Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing/Bridging - `1 n �� 1 j 2 x'e (3) Joist hangers Jack Posts/Main Beams cluck Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. - / /� / v�J�� 1 ZjC�� T`v. (�►hr(ac� 4RN der StairwreUs 36 in. or more Exterior Deck Bracing l 1f Headroom 6 ft. 8 in. - t',, i i a.1( /VC 1 1 We G,- Notches I Holes /Bearing Walls CIt o iA? k ?y r tuct r L Metal Strapping for Notches Top Plate r 1 'A(w) 16 gauge (8) 160 nails each side -- I ' ht C(1rf °� (f'I7 L4 4d Draft stopping 1,000 sq. ft. floor trusses e Anchor Bolts 6 ft. or less on center -T- 1 /l Ice and water shield 24 inches I �sLk- h/ ( l4� 0- 1-c ee nches from wall • Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side IA inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above / below grade 5.0 sf grade L:\Building&Codes Forms-OLD\Buiiding&Codes\inspection Fornis yarning Firestopping Inspection Repori.doc Revised January 7,2008 uuz4 6;t_ 1 0 -I i l .3c) Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection - • t4 5 • 5 0- Queensbury Building &Code Enforcement Arrive: a • j = -rt: `r a• pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial:• 4. ./ NAME: , A. � - RMIT#: r 0) -e, S I LOCATION: . 5 l c KS • NSPECT ON: TYPE OF STRUCTURE: ______?AccEsi,p_. Cji Y N NU�iI� COMMENTS: r rami .• Attic-Access 22" x 30° minimum Jack Studs/Headers --Sy Bracing I Bridging Joist hangers ■ ,D �J� cLcQ Jack Posts/Main Beams Exterior sheeting nailed property t —0"c V7 J t�E-5 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches/Holes/ Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge (8) 16D nails each side T - - stopping 1,000 sq. ft. floor trusses ?.% ; -. or -ss on center--- ' ►= and water shield 24 inches from wall j`j � 1 t F- A"\CZ Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour �^ . Firestopping �} Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 's inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-0LD18uilding&Codes\Inspedion Fams\Freming Firestopping Inspection R.eport.doc Revised January 7,2008 r n c c�-`� f 3 Queensbury Building & Code Enforcement - Residenti_ _ n_pection Office No. (518) 761-8256 Arrive: t /p `�- .art: I1,r Date Inspection request received: Inspector's Initi- : ,/L* NAME: C r.CJ d _s IT#: / D -C: / LOCATION: (i7 t 1-1- 1 C t� 3 R Cl )ATE: TYPE OF STRUCTURE: 2-- omments: Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location V"\\ A� Fresh Air Intake w 3 inch Plumbing Vent through roof minimum 18 inches N Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more 1_13—it Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant ��YrJS- Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight tea`— ' .12C22 Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors l" ��- �j� > Every level: Every Bedroom: Outside every bedroom area: >`A Inter Connected: _ Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area �J Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft. vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 (Temporary/Permanent] L:1Buiiding&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form revised_100405.doc; Revised January 7, 2008; Revised 6/26108; Revised 12/22/10, Revised 04/13/11 Queensbury Building & Code Enforcement - Residential i a Inspection Offic4 No. (518) 761-8256 Arrive: a : �� /% = " : m Date Inspection request received: 1// ,•l7 (lie j 7- Inspector's Initia /r//MErit . NAME: t PEr # �-?�1 LOCATION: �t'*WA=�Y D' • 7/tip TYPE OF STRUCTURE: e , C,�rrJx a Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs, decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors 1 Carbon Monoxide Detectors Every level: Every Bedroom; Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft. vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation to floor 1 Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss, draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%*Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3A hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/O[Temporary/Permanent L:\Building&Codes Forms\Building&Codeslinspection Fomis1Residential Final Inspection Form_revised_100405.doc; Revised January 7, 2008: Revised 6/26/08; Revised 12/22/10, Revised 04/13/11