Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2008-228
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20080228 Date Issued: Thursday, February 16, 2012 This is to certify that work requested to be done as shown by Permit Number P20080228 has been completed. Location: 694 SHERMAN Ave Tax Map Number: 523400-301-019-0001-003-000-0000 Owner: RALPH & CAROL BRAYTON Applicant: RALPH & CAROL BRAYTON This structure may be occupied as a: Certificate of Occupancy (RES) By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property ( �� s4 owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080228 Application Number: A20080228 Tax Map No: 523400-301-019-0001-003-000-0000 Permission is hereby granted to: RALPH& CAROL BRAYTON For property located at: 694 SHERMAN Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RALPH& CAROL BRAYTON 694 SHERMAN Ave Certificate of Occupancy(RES) $34,000.00 QUEENSBURY, NY 12804 Total Value $34,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2008-228 residential rehab - HUD $25.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, May 20, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at theown o uee u May 20, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement _...___."------------______________ - � E c E 0 w E ��. OFFICE USE ONLY 'f" - """""-�"""""""' 301. j3 , o TAX MAP NO. 1008 oo PERMIT NO.___�2[ ; ; FEES: PERMIT RECREATIONENGINEERING 0 S TO OF;,,ENSBURY (If applicable BUlLt�IG& CEDES _ ) I PAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: i"/ rectSlc�Y� ti�c� 00 OWNER: ADDRESS: ADDRESS: (0 S 1 e rm 5?n g(je_ PHONE NOS. 7 y 7'Z S.34n PHONE NOS. ?q-3 - q noy CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: -skv-e C4 ONE: 5'q „ -e LOCATION OF PROPERTY: 5-a ) SUBDIVISION NAME: �� PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z oLL C'1 PROJECT 0O p � U) U) (n F-w o w iU- iU_ = Q EL ~ 0 Z ¢ Q � � NU) Ou � U- n- ixs SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ' CCTIhAA-rCM r-r1AIQTmI 1,1-rl 1Ai n^nr. l G.J /"',./*✓� �. ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? f� ARE THERE EASEMENTS ON PROPERTY? � 'L I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete state me nt/d escri ptio n of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the ab Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ...................... Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building ; herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: 0 , 0 / , ;ZAANO�i BUI G & CODESP A ZONING APPROVAL 4AE DATE 00I QUESTIONS? CALL 761-8256 OR EMAIL codes(a)-gueensburv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensbury.net Operating Permit Issued: Yes No r IMPROVEMENTS TO C 694 Sherman Avenue SUS-ATtOC DUST BE CCVERE� QUEENSBURY, NY 12$04 UAB 1N. 5 MiNBTE THERi+�AI BARRI.�E _.. PROPERTY OWNER Ralph&Carol Brayton 694 Sherman Avenue Queensbury, NY 12894 743-9404 TILE KRAFT PAPER INSULATION MUST Pc COVERED BY NON-COMBUSTIBLE PT'' LEAD BASE PAINT HAZARDS The Department 'oft Housing & Urban Development (HUD) has issued regulations regarding the .........Reducflon'of Lead-Based Paint Hazards in ....... Housing Receiving Federal Assistance." The rehabilitation work called for by these work specifications will be paid for in whole or part with federal assistance. Therefore HUD's regulations governing the reduction of lead base paint hazards apply to this project(24 GFR Part 35). A risk assessment has been performed for this property and project and no lead based paint hazards have been identified, No action is required at this time. Co not pians and spec Icax 7`r` ¢t Yii Compliance 0" t' ;v "W �J C of NOTE: New YorK SIZa, NO LEAD BASED PAINT HAZARDS HAVE BEEN IDENTIFIED A CLEARANCE REPORT IS NOT REQUIRED _ 0vVN 0 Ppy L.� 1 Brayton 694 Sherman Avenue ELECTRICAL A€I work is to be performed in accordance with manufacturer's instructions,NYS Building Code,Local Building Code and attached ELECTRICAL SPECIFICATIONS. CONTRACTOR IS REQUIRED TO ION OBTAINPETION BEFORE FINAL PAYMTENT. LIST R ALL WORK AND TO PROVIDE A CERTIFICATE OF COMPLETION F ELECTRICAL INSPECTORS IS INCLUDED N THE ATTACHED ELECTRICAL SPECIFICA ONS. 1. Electrical Service rO Disconnect existing service Install new 200 amp service,with adequately sized breaker panel;best possible location ► Provide new wiring for entire house, per specifications and NEC, including all receptacle, light fixtures and switches. Use of wire mold is the preferred method where walls are intact. > Install hard wired,interconnected smoke detectors in each bedroom. ► Install hard wired,interconnected smoke and CO detector in basement. ► Provide hard wired smoke and CO detector at a location near bedroom(s), interconnected to all others. LIST PRICE HERE S � 9 DRYWALL and TRIM All work is to be performed in accordance with manufacturer's instructions,NYS Building Code,Local Building Code and attached SPECIFICATIONS. } jj 1. t)RYWA L -,.3 Remove existing ceiling materials throughout entire house ► Remove wall materials in kitchen and bathroom Install new'/Z drywall ceilings > Install 1/2"drywall wails in kitchen and bathroom Install moisture resistant drywall at tub/shower > Tape and finish (3 coats) ► Prime all new surfaces > Paint ceilings with 2 coats of good quality latex paint,flat white ► Paint walls with 2 coats eggshell off white 2. TRIM ► Install pre primed,finger jointed ranch or colonial base and casings. Provide cove molding at ceilings, as necessary. • Paint with 2 coats good quality latex 2000 LIST PRICE HERE$ — a Brayton 694 Sherman Avenue FLOORING All work is to be performed in accordance with manufacturer's instructions, NYS Building Code, Local Building Code �05 --7-yd,;d achedFLOO RING SPECIFICATIONS i. Kitchen/Bathroom • Install 1/21'plywood underlayment xb ► Install medium grade vinyl flooring not to exceed $15.00 square yard. Perimeter-type flooring is NOT allowed. LIST PRICE HERE$ Q PLUMBING All work is to be performed in accordance with manufacturer's instructions, NYS Building Code, Local Building Code and attached PLUMBING SPECIFICATIONS. 1. Bathroom ► Install new 2-piece fiberglass tub/shower unit(white)56t� 00Provide new faucets,drain, spout,shower head,etc(pelta or equal)2��� Install new white comfort height toilet(American Standard or,equal)t5;�A ► Install 30"vanity unit, 1 pc molded vanity top,new faucets and drains 7 4* Replace old water lines and drains as required, provide adequate venting for all f xtures.S�'� 2. Basement Replace approximately 5 ft.of cast-iron drain pipe with PVC t,59 ► Assure sump pump is property drained to exterior and assure proper function ' ► Install new expansion tank and assure adequate pressure -2s6 3. Kitchen Install new lines and faucets at plumbing to kitchen sink and assure adequate water pressure D NOTE: Constant water pressure is to be provided to all plumbing in kitchen and bathroom. All systems are to work properly. (.� LIST PRICE HERE$ ! Z&O Brayton 694 Sherman Avenue 5 � T5 3,. XI �3 e Lr Cv et ROOFING 1. Main Roo i ion ► Completely remove existing roof materials, including sheathing ► Make all necessary repairs to rafters/trusses j ► Install new sheathing per specifications and building code {p Install T ice and water shield at eaves and in valleys ► Install new 15 lb felt,aluminum drip edge,and all necessary flashing and venting, etc. > Install new metal roofing; homeowner will have choice of stock colors 2. Front Enfry and Back Porch ► Remove existing roof surface > Repair or replace sheathing as necessary - > Install new flashing as required > Install new rubber membrane roofing LIST PRICE HERE S► INSULATION � r �� ► Install kraft-faced insulation in walls that are specified to be installed (bathroom, kitchen) '�+ ► Install kraft-faced insulation above all ceilings NOTE: All insulation services other than those listed in these speciifications are to be provided by the Warren-Hamilton Community Action Agency UST PRICE HERE S CABINETRY-OPTIONAL l" All work is to be performed in accordance with manufacturer's instructions, NYS Building Code, Local Building Code and attached SPECIFICATIONS. 1, Kitchen ► Install approx 15 linear feet of new wail and base cabinets,per specifications (Aristokraft or equal) ► Install post form laminated countertops; homeowner will have choice of stock colors Install new double bowl SS sink and faucets 2. Bathroom Q, 00► Install matching, lighted medicine cabinet above vanity. LIST PRICE HERE$ 6 Brayton 694 Sherman Avenue r` r EXTRAS NOTE: The cost of building permits and electrical inspection is to be included in contractors bid rices and is not to be fisted as a se arate cost and is not an isextra l 1. Identify additional separate cost to install or remove additional items not mentioned in specifications that may be necessary to comply with code and complete the job in a satisfactory manner and list separately here. ll1eed y� �er A 2. Items not listed as additional are assumed to be included in contractors bid price. LA-,o r N I S i.IST PRICE HERE r -''"_ icef+-5 nor ki trrvpl 3�W "el d r 7 694 Sherman Avenue Rrnvrnn t IMPROVEMENTS TO 694 Sherman Avenue QUEENSBURY, NY 12804 PROPERTY OWNER � ` A gc. Ralph &Carol Brayton 694 Sherman Avenue ` Queensbury, NY 12804 - 743-900417 1 �a y u y A CHANGE ORDER June 24, 2008 Plumbing All work is to be performed in accordance with manufacturer's instructions, NYS Building Code, Local Building Code and attached PLUMBING SPECIFICATIONS. • Provide and install new (40 Gal) Electric water heater. Ventilation Main Roof • Enlarge existing gable vent at front of house; install new, screened vent. • Remove upper course of siding material at eaves of main roof. • Drill or cut through blocking between rafters to create additional air flow. • Install white vinyl or aluminum fascia at eaves and gables of main roof and front addition front. • Install white vinyl ventilated soffit at eaves and gables as above. Brayton 694 Sherman Avenue 1 r Back Porch/Entry • Remove existing roof over back deck, at entry way including posts. • Install property sized header above door and window at end wall of back porch. • Repair or replace rotted floor joist(s) at same end wall to provide support for new header. • Provide footings and posts as required to support end wall. Painting • Prime and paint exposed OSB sheathing at front porch. -Wh reofd e1ectncei meTer figsbeen removedrepair with w-i to coil-stock -- --- or similar shingles. Storage Pod • Extend storage pod lease for an additional month (2 pods) 1. Plumbing 600.00 2. Ventilation 1,900.00 3. Back Porch 1,000.00 3. Painting 200.00 4. Storage Pod 600.00 TOTAL PRICE CHANGE ORDER $4,300.00 Name of Company Signature of Principal F:\60\Queensbury\Small Cities 05 Implementation\Projects\694 Sherman Ave\Specifications\Change order 6-24-08.wpd Brayton 694 Sherman Avenue 2 Queensbury Building & Code Enforce ant - Residential Final Inspection am/Pm Depart: �� I am/pm Arrive: - Ice No. (518)761-8266 inspector's Initials: Date Inspection request received: PERMIT#: NAME: DATE: LOCATION: TYPE OF STRUCTURE: • Comments: J. �. N NIA E` f 4° Buildin Number Address visible from road Chimne Hei ht/"B*VentlDire_�t Vend Location Fresh Air Intake 3 inch Plumbin Vent throu h roof minimum 6 inches Roof Co late/Exterior Finish Com ate Platform at all exterior doors Handrail 4 or more risers __. r Guards at stairs decks atias more 4han 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck rches 36 T as or more — Handrail Termination at Newell Post or Wall Interior/Exterior Railin s 34 inches to 38 inches Deck Bracing/Handicapped Ram Compliant Grade awe fram foundation 6 inches with 10 feet _ 6 inch clearance to sill plate -- Gas Valve shut-ofE exposed I re ulator 18 inches above grarie Interior rivac I trim I doors/main entrance 38 inches Bathroom/Kitchen wateq!2ht_ Safe lazin /Win in stairwells safe la �- i interior Smoke Det ars/Carbon�noxide atectoi j Every level: Every Bedr m: Outside every bedroo area: ✓ 1✓ ��,\(Z �� ,t�a " inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches hei ht in accessible area Crawl S aces 18 inch x 24 inch access 1 ft.-150 s .ft.vents Bathroom Fans if no window Plumbin fixtures Foundation insulation/Insulation Certification Floor truss,draft stop in finished basement 1,000 sq Eme en ress below rade Gas Furnace shut-off within W feet or within line of site Oil Furnace shut-off at entrance to#urnace area Fumace/Hot Water Heater o eratin Low water shut-off boiler - Relief Valves installed/Heat Ira /Water Temp110 Enclosed Stairs Sheetrock underside minimum 1/2'Gypsum Basement stairs closed rise> A inches Garage Floor Pitched Gera a fins roofin /'/,hour fire door/door closer Duct work Sealed property _- Gas Loge in Sealed or Glass Enclosure Final Electrical ----- Final Surve Plot Plan _— Arc Fault Breaker in Bedrooms _ Flex Gas Pi a Bondin As Built Se tic S stem/Sewer Dept, Inspection Sticker___ Site Plan /Variance r uired Flood Plain Certification,if rpquired __ Oka to issue C I Cor C f 0 I Tem ora I Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_l00405.doc;Revised January 7,2008;Revised 6/26/08 y /VL©A-4Vr Queensbury Building & Code Enforcement - Residenti I Final Inspection Mice No. (518) 761-8256 Arrive: am/pm Depart•_ ��\ am/pm Date Inspection request received: Inspector's Initials: NAME: —�►�GC. j^�, PERMIT#: ` LOCATION: ✓ DATE: TYPE OF STRUCTURE: _. _ Comments _ Ye No NIAC- 4" Builth Number Address visible fry road Fresh F �.��,�� �1� .,�`- ®.�h�6yr resh Air Intake Hei ht/"B'Vent/Direct Vent Location lo,FA Ives'� I 3 inch Plumbing Vent through roof minimum 6 inches Roof Co ete I Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks, tics more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/E)derior Railings 34 inches to 38 inches Deck Bracing/Hand' RaM Compliant Grade awa from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/trim/doors!main entrance 36 inches_ Bathroom/Kitchen watertight Safety glazing/Window in stairwells oafety gWing_ Interior Smoke Detectors/Carbon yfonoxi etectors Every level: E ry Bedr Outside every bedroo area: `%�� � Inter Connected: k Battery backup: Attic access 30 incheb x 22 inches x 30 inches Nei ht in accessible area Crawl Spaces 18 inch x 24 inch access, 1 N.ft.-150 sq.ft.vents Bathroom Fans,if no window ------ Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 N.ft. Emffoncy egress below grade Gas Furnace shut-cuff within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valy s installed/Heat Trap!Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/'Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed property _ Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms _ Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance Eeguired _ Flood Plain Certification,if Leguired Okay to issue C I C or C 10 1 Temporary/Permanent LABuilding&Codes FormsiBuilding&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc,Revised January 7,2008 Queensbury wilding & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/pm art:2\t am/pm Date Inspection request received: Inspector's Initials: NAME: PER #: LOCATION: " DATE: -- ' — TYPE OF STRUCTURE: Comments: Yes No WA 4" Buildi Number Address visible from road - Chimney Hei ht/"B"Vent/Direct Vent Location s C, % SL) Fresh Air Intake 3 inch Plumbigg Vent throggh roof minimum 6 inches Roof Complete/Exterior Finish Complete_ Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,p2tios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall d Interior/Exterior Railings 34 inches to 38 inches Deck Brad /Handicapped RaM Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shutoff e 1 regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safe 11azing "-- Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batterybacku Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents I Bathroom Fans,if no window u a fixtures F Foundndation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency cess below grade Gas Fumace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum 1/2"Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct worts Sealed ro Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms _ Flex Gas Pipe Bondin _ As Built Se tic S stem/Sewer De t. Inspection Sticker Site Plan /.Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Tem ra /Permanent L\Building&Codes Forms\Building&Codes\Inspecion Forms\Residential Final inspection Form_revised_100405.doc;Revised January 7,2008 Rough plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Insp on re est eceived: Queensbury Building & Code Enforcement Arrive am/p epa am/pm 742 Bay Road, Queensbury, NY 12804 Inspe r Initia6s: NAME: _ PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough_Plumbing Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout evea 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above hi hest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 -P.S.I for 15 minutes sulation Residential Check I Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If re uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct to e COMMENTS: L:\Pam Whiting\Building&Codesunspection Forms\Rough Plumbing Insulation Report-revised Nov 17 2003.doe Revised February 15,2005 Framing / Firestopping inspection Report Office No. (518) 761-8256 Date Inspection request received: /_1 16 Queensbury Building &Code Enforcement Arrive: am/pnb n am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:"---�/` NAME. PERMIT#: ' LOCATION: 2l INSPECT ON: 0 TYPE OF STRUCTURE: ... Y N NIA Fram' COMMENTS: �., � Attic Access 22" x 30' minimum Jack Studs/Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D rails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wail 2, 3, 4 hour �^ Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 's inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilin fwall _ Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LAMIding&Codes Forms-01-MBuiiding&CodesUnspec tion FoffnsTraming Firestopping inspec tion Repod.dloc Revised January 7,2008 Rough Plumbing I Insulation Inspection4e-'p'ort Office No. (518) 761-8256 Date InspectiQn request received: h I&) _ Queensbury Building & Code Enforcement Arrive: am/ m part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME: � A PE ' PERMIT �#. � LOCATION: INSPECT ON: TYPE OF STRUCTURE: r Rough Plumbing /Nail Plates Y N N/A Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head r 15 minutes rnsulatignfResidential Check/Commercial Check I A)' i �A i�� Ilar Exterior Sealant ProperV , Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If re uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15, 2005, revised January 7, 2008 S!5- Rough Plumbing / Insulation Inspe� ion Report Office No. (518) 761-8256 Date fnpesction request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspect iInitials: NAME: r� °�'� PERMIT ##: LOCATION: 0j� � .t INSPECT ON: 7 TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check T ek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revises!January 7, 2008 7 -- / Rough Plumbing / Insulation In ection Report —1 Office No. (518) 761-8256 Date Inspectic N request received: Queensbury Building & Code Enforcement Arrive: am/ De art: am/pm 742 Bay Road, Queensbury, NY 12804 Insp is I itials: NAME: PERMIT #: LOCATION:_ INSPECT ON: TYPE OF STRUCTURE: . .� Y N NIA r �.7//�`►►�'^ ou h Plumbing / ail Plates Ck��'Y\�T/All n /Vents in Place 1 Y2 inch minimum Drain Size t _lA) Washing Machine Drain 2 inch minimum rte 100 feet/change of direction 2 ��ti'�� �C- ,► Pressure Tes ent d �J Air/Head or bove highest connection for 15 minutes Pressure Test aping j50AjrHead S.I for 15 minutes Insulation/Residential Check/ Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If Eeguired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / FirestoPP g in Inspection Re rt Pe Re/port Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: _am/p /a[ am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME:--- J�r' A-1- PERMIT#: ,22S LOCATION: r INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA. COMMENTS: Attic Access 22° x 30° minimum Jack Studs/Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed property 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2 w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour ire our Firestopping Pene ration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-01-Muilding&C desMnspection FerrnsTraming Firestopping inspedion Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive;: am/pm art: I.J.1 a am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: UT NAME: iZ PERMIT#: ► ~�� LOCATION: INSPECT ON: TYPE OF STRUCTURE: _. 4 Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging L Joist hangers Jack Posts/Main Beams .�L�vs"� Com+ Exterior sheeting nailed properly , 12"O.C. �,�� Headroom 6 ft. 8 in. Stairwells 36 in. or more _ Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/i w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall -- ^ Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. I Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Ins ec ion Report Office No. (518) 761-8256 Date Inspection request received: _ �a Queensbury Building & Code Enforcement Arrive: am/pm Depart: ��) m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: 2 5�� LOCATION: INSPECT ON: TYPE OF STRUCTURE: a Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping fir/.dead 15 minutes Insulation / ,esidential Check/Commercial Check k ilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: I Arte. am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:4 l I ) L) NAME: CJ's PERMIT#: C LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging �F2. Joist hangers Jack Posts/Main Beams L Exterior sheeting nailed properly r �. �- � " 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more ExteriorDeck Bracing ,, - -Headroom . 8 Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate R 1 '/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses /� ,�` i Anchor Bolts 6 ft. or less on centers �►�'` � V'�`f� �- Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'r2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (10V) 5.7 sf above/below grade 5.0 sf grade LABuilding$Codes Fomss-OMBuilding&Codesllnspedion FomtsTraming Firestopping Inspedion ReporLdoc Revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspect* ,rst received: Queensbury Building & Code Enforcement Arrive: �am/pm. ?Tart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: y N/A A Rough Plumbing / Nail Plates 7' Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size G( Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head .�, � ,7 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation �� -.A `T If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape 1e--6 f t�).q COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report 1 Office No. (518) 761-8256 Date Inspectiio-n,'jequest received: Queensbury Building&Code Enforcement Arrive:I", 'J"am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: vZ22a NAME: PERMIT#: (, LOCATION: f _ INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 w) 16 gauge 8) 16D nails each side Dr ft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation. House side i/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspectiorequest received: Queensbury Building&Code Enforcement Arrive: /60am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspectorls:64- __ NAME: 60-7/1 d/1) PERMIT#: G76-72-8 LOCATION: &NAAI Z41C— INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS Framing - � Attic Access 22"x 30"minimum Jack Studs I Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center f� Ice and water shield 24 inches from wall r Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation. House side t/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date In"!-ti equest received: Queensbury Building&Code Enforcement Arrive: m/ Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's nitials: NAME: I Jl? rvn) PERMIT#: �— LOCATION: &, _ INSPECT ON: V2.�` O TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum / Jack Studs!Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade