2011-085 41111.aki TOWN OF QUEENSBURY
742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201
Q rY,
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20110085 Date Issued: Friday, September 16, 2011
This is to certify that work requested to be done as shown by Permit Number P20110085
has been completed.
Location: 67 PEACHTREE Ln
Tax Map Number: 523400-301-018-0001-055-000-0000
Owner: PATRICIA ANN KELLY
Applicant: CHIP & KELLY ESPER
This structure may be occupied as a:
Fireplace By Order of Town Board
Residential Addition TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the r ff / I `�
property owner of the responsibility for compliance with Site Plan, �rLv
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
01.1`
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20110085 Application Number: A20110085
Tax Map No: 523400-301-018-0001-055-000-0000
Permission is hereby granted to: CHIP & KELLY ESPER
For property located at: 67 PEACHTREE Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: PATRICIA ANN KELLY
67 PEACHTREE Ln Fireplace
Residential Addition $100,000.00
QUEENSBURY, NY 12804-0000 Total Value $100,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2011-085
1259 sq ft residential addition with 1 fireplace
$251.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,April 12, 2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town Queen .ury; Tuesday, April 12, 2011
SIGNED BY . ,'G �. for the Town of Queensbury.
Director of Buildingk4 Co nforcement
4
50 l` ' g't_SOFFICE USE ONLY
tj— (di—
�i�4TAXMAPNO. _ PERMIT NO.
; E ERMI i. — —EN INEERING___-- — r'`.t...),-) Il
a`'" � �_ !=� -��� (If applicable) r t r�;j
,�L L `r 'Nb 1.It/,.til (.J j r' �� 4.-I: '/f
•KPRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING
`t PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW
BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: L19+ )jr::: 1 12— OWNER: is.,tvice
ADDRESS: LQl A-11-12. 1..PAE_— ADDRESS:
PHONE NOS._7_Y — "2-12-C) PHONE NOS. _
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE:�uU>vs� PHON: 580-Ia2
LOCATION OF PROPERTY:_6;1 -C kA _/____—_—
HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? 0 YES l NO
IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT p a
APPLY TO YOUR z 1 o p g w W
PROJECT p � 0 � � _ _
0 W _1u. U_ LI— _ ODU
W O [-LI-
d z d �' {- a1- ccW —
Z Q Q - w NU) 0 L HU_ LL2oo
SINGLE FAMILY V 6S‘ 10b / 126c1 V1-t'
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804
Revised 4/14/2010
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: N i_P‘
ESTIMATED CONSTRUCTION COST:4 IQ04.0 FUEL TYPE: WXC. &
HEAT TYPE:_401- 1g__ *HOW MANY FIREPLACE(S): /2-±j ,AND/OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?-- _ 140
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: �1N� _
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? _1•Ab
ARE THERE EASEMENTS ON PROPERTY? _NICA4OU3N
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read - • agre= o t •.
Signed ="---- ---- r 14 1!/7r
)be PIE
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes
or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Town of Queensbury* Community Development Office* 742 Bay Road, Queensbury NY 12804
Revised 4/14/2010
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application:
BUILDING & CODES APPROVAL ZONING APPROVAL
AVa
DATE DATE
QUESTIONS? CALL 761-8256 OR EMAIL
codes(a�queonsbury.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
www.queensbury.net
Operating Permit Issued:jYes No
Occupancy Type: ` \J _Construction Classificati
edon:
Assembly Occupancy Limit: Special Conditions:
Town of Queensbury* Community Development Office* 742 Bay Road, Queensbury NY 12804
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm Depart - am/pm
Date Inspection request receiveedd: Inspector's Initials: _�frkk)
NAME: PERMIT#: 2- V oc
LOCATION: b16-e_,--a4--€.._ DATE: C/N\
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road }L
Chimney Height/"B"Vent/Direct Vent Location �/ /✓C,`'
Fresh Air Intake , /I DUa—itia<k_3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs, decks, patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall /
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches t//:,
V
Bathroom/Kitchen watertight
Safety glazing/Widow in stairwells safezing
Interior Smoke Defectors/Carbon noxi Detectors
Every level: Ev Bedr m: 1/
Outside every bedroom rea:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area f
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
V:"Bathroom Fans,if no window
Plumbing fixtures ✓
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/"Gypsum &(/ C5IS
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing 1%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure 4/f
Final Electrical V
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required10
Flood Plain Certification, if required
Okay to issue C/C or C 1 0[Temporary/Permanent]
L:1Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10
67_1
oQueensburyBuilding & Code Enfrcemen - gesik-r‘itylrial Inspection
'Vice No. (518) 761-8256 Arrive: �5
am/pm D art .'am/pm
Date Inspection requestqureceived: Inspector's Initials:
NAME: �� rp PERMIT#: 4i--- -- i.F.---
LOCATION: ,� fi--iet- !_� _ DATE: --
TYPE OF STRUC U E:
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete //'
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks, patios more than 30 inches above grade
Guard at stairwell at 34 inches or more V
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet _ _ _
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing(DWie n�d w in stairwells safety gla g
Interior Smokectors/Carbon M oxide etectors
Every level: Eveedro /
Outside every bedroom ea: `/O
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel 'L
Duct work sealed properly/
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site F _
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating -^ .--
Low water shut-off boiler 5J!�{�
Relief Valve(s)installed/Heat Trap/Water Temp 110 / ( ..''' --,
Enclosed Stairs Sheetrock Underside minimum'/"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
/
Garage fireproofing/3/4 hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical; Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof ReceptaclesV/
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification, if required0
Okay to issue C/C or C/O[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection For nslResidential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit Cert. N 2 2 187
Cut-in Card No.....................................
Owner..................
...............................
Location.....(t..7.....
.WC14-7 /V
. ....................................................................................................
Install tion Consisting ......................
....1Y...C ...I.... ......11s: ...z ..Z ..... ...............................................
............I........................................................................................................................................................I..............
Installed By....... ,....C.,ff—j Ifo.s.K>...............................Li,.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled--
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
N
Inspectors of this Company shall have the privilege of making Airs—p—6-L ions at any time, and if its
rules are violated,the Company shall have the right to re/bK)his c . ate.
Date... .................. INSPECTOR......
....Vz.................:::::r.....................
Member N.F.P.A.,I.A.E.I.
/ `�
Y,t
Town of Queensbury Fire Marshal ,
742 Bay Road
Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Gas Fireplace/Stove Inspection Report
Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# 1/ C"4?3 Schedule Inspection ,2 ( / Time// ,/0 am pm anytime Inspector
Name lam, ,,/� Address /' 6 90C-- >,-
e-e Rough In Final_
Appliance Manufacturer Model# )->\,/R�3(Y`
ekii
Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A Comments
Floor Protection V
(all sides) VIUV5
Clearances to Combustibles
Firestop(s) Vertical Chase
i 10,t- •C‘--2C
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve
Combustion Air 7/..
Hearth Extension (if any)
Mantel J
Height above f/p opening
Witness Operation V
Tank Placement(if LP) V
CO Detection
CSST Bonding
White—Building Dept. Yelton—Customer Pink—Fire Marshal
i
F-10 -SL
Town of Queensbury Fire Marshal
tiir 742 Bay Road
N Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Gas Fireplace/Stove Inspection Report
Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# /1-08.- Schedule Inspection , ..:12___'/ l Time am pm anytime Inspector J1'
sm
Name e------ 6r Address l 1 ' tcf -e . L . Rough Ink Final
Appliance Manufacturer I\AA Model# 1\1 ."1.
Direct Vent \ic.,Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A Comments
Floor Protection , <; Z, ? . ,��' ( J ?,.. 6��'�3
Clearances to Combustibles (all sides) ���. � ��
Firestop(s) Vertical Chase /
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve l/. .
Combustion Air
Hearth Extension (if any) 7
Mantel
Height above f/p opening
Witness Operation
Tank Placement(if LP)
CO Detection
CSST Bonding
White—Building Dept. Yellow—Cust mer Pink—Fire Marshal
//
Rough Plumbing I Insulation" sp
ec : Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: rn/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: t woLA--
NAME: S/ PERMIT#: --/'t
LOCATION: - INSPECT ON: - --
TYPE OF STRUCTURE:
Y N N/A_�
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 34 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout eve 100 feet/chane a of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
i . •r 15 minutes
Insu = •n/ esidential Check/Commercial Check
imilar Exterior Sealant
Pro. =r Vent,Attic Vent
Door/Window Sealed (No Insulation)
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
r - 3 ?
°?7'
- r27 / fr%
Rough Plumbing Insulation Report.revised Nov 17 2003,revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspe ion Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Departam/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: !
NAME: S . J • PERMIT#: // c?5
LOCATION: _= INSPECT ON: 7411A - /
TYPE OF STRUCTURE:
1° ,4 N N/A COMMENTS:
Framing
1111
A ' ss 22" x 30" minimum
Jack Studs/ Headers , `&-3 /
Bracing/ Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" 0.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes / Bearing Walls
Metal Strapping for Notches Top Plate
1 '/s(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Botts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping 111
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\Building&Codes Forms-OLD\Buiiding&Godes\nspedfon Forms\Framing Firestopping Inspection Report.doc Revised January 7,2008
Rough Plumbing I Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request-re-,'v- •:
Queensbury Building & Code Enforcement Arrive: 9 7 arn,/•m =pa• : t13bcn
742 Bay Road, Queensbury, NY 12804 Inspector's Initial • .,.
NAME: i=�,� ��� PERMIT #:
LOCATION: (67 P171-RC��-1-WF- INSPECT ON: Ccs -Zc11- 1
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Piates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size _
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
Insulation / Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant _
Proper Vent, Attic Vent ZAP
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace T
Duct work sealed properly/ No duct tape —{
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 18,2005, revised January 7, 2008
ems--ber- - 'o f& Ja
Fra ing / Fir opping Inspection Report '
Office No. (518)761-8256 Date inspection request received:
Queensbury Building&Code Enforcement Arrive: c l6 am/pr De ______am/pm
742 Bay Road, Queensbury, NY 12804 Inspectos Initials:
NAME: PERMIT#:
LOCATION: 6 J lr, .P INSPECT ON: d :VAI/
TYPE OF STRUCTURE:
Y N COMMENTS:
Framing
Attic Access 22'x 30'minimum
Jack Studs/Headers
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
•
Notches I Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 ,6(w) 16 gauge(8) 16D nags each side
Draft stopping 1,000 sq.ft.floor trusses
:{, : 6 ft. or lesson center
Ice and water leld 24 inches from wall
- - ion 1, 2, 3hour
Fire wall 2, 3,4 hour
Firestopping
Penetration seated
16 inch insulation in cavity min.
Garage Fire Separation
House side'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Calling/wail
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:Building&Codes Fonns.OLDlButldi g&codesunspedion FormoVraming Flmstopping trspedion Report doc Revised January 7,2008
I/cttI
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive:`-{ ' 6 am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: spec PERMIT#: //-6
LOCATION: ‘i L'`., INSPECT ON: = ��
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg i
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
orches above footing
6 mil poly for wet areas under slab
a kfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Buiiding&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
/—.3 " c/ia
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart 2pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:04)
•
NAME: PERMIT#: . —Id
LOCATION: G _ e / ...INSPECT ON:
TYPE OF STRUCTURE:
CQn enls
X WA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing peon from freezing
for 48 hours following the placement
tarials for • 4 1 ,:= on site.
Foundation/Wallpour
ItehrforeementhrPlare
Footing Dowels or Keyway in place
Foundation Dampproofng
Foundation Waterproofing
Footing Drain Daylight.or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6milpolyforwetareasunderslab
Backfill Approval
•
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior 1 Exterior
• R-
Rough Grade 6 inch drop within 10 ft.
L:1tutlding&Codes Forms\Buitding&Codes\Inspec tion.FormslFoundation Inspection Reportdoc
Last printed 12/20/2005 9:24:00 AM
(4.1-fri 1046- 6-ida
Foundation 'on Report
Office No.(518)7614256 Date Inspecti request received:
Queensbury Building&Code Enforcement Arrive: 1 i'.1 am/pm
Depart:
rt: am/
742 BayRd.,Queensbury,NY 12804 Inspector's Initials:
NAME: er' PERMIT#: .
LOCATION: 7 7r-,4 tP'e /t. INSPECT ON: -Z- -
TYPE OF STRUCTURE:
CQents
Y/L Nitt,
Footings eL6,
erg
Monolithic Slab
.Reinforcement in Place *-4
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation DamPIroofmB
Foundation Waterproofing .
Footing Drain Daylight.or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
•
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LABending&Codes Forms\Buiiding&Codes\inspectlon FonnsWoundation Inspection Reportdoc
Last printed 12/20/2005 9:24:00 AM
r_.
/ /- 0(n.
LOT 74
(;f)MMON AREA
4 NC5 ,5(6' S N
Tt
0
5
\ ,ci
3 7'-d \'' �4,
.0 O
O.
\lii,
\,)04 )
LOT 72 `65 04
.<2g. 00
i5•
.0.
NCIIC.19.
0
O
B
67 PEACHTREE LANE
(L0' 73 SHERMAN PINES SUBDIVISION)
..k
TOWN OF QUEENSBDR,
BUILDING & C
Reviewed DES DEF
Date:. _
PROPOSED PLOT PLAN
1" = 10'-0"
GENERAL NOTES
INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM
A SURVEY DRAWING PREPARED BY VAN DUSEN AND STEVES
LEGEND
- - - - - - - PROPERTY UNE
----------------------- PROPERTY UNE SETBACKS
----------- 330 ---------- EXISTING CONTOURS
330 NEW CONTOURS
—E —E E —E UNDERGROUND ELECTRIC SERVICE
— ss —ss ss —ss SANITARY SEWER
-- w —w w —w WATER SERVICE
----------E/P EDGE OF PAVEMENT
SITE
DATA
PROPERTY ZONING
CLASsinCATION:
MDR MODERATE
DENSITY RESIDENTIAL
MINIMUM Lor SIZE:
2 AC-RES/1
ACRE PER DWELLING
UNIT
MINIMUM LOT WIDTH: 100 FEET
TAX MAP NUMBER:
301.18--1-55
5EXAM
W
REQUIRED
EXISTING
MON T
I_—
30'-0"
35'-1"±
SIDE
EXISTING TILE
FIELD IS LOCATED
10'-0" MIN.
'
\
IN COMMON AREA
30'-0" TOTAL
22'-6"±
REAR
BEHIND ALL RESIDENCES
30'-0"
43'-3"±
MAXIMUM BUILDING
�
40'-0"
28'-0"±
�\ ,toy • ,
PERMEABLE
50%
78,296
z
J
5
`
W
00
N
E
p
w
O
olp
r'
U `
wed
EXISTING �
SEPTIC TANK
)-
ON
LOCATION
�=
k
Firw
go—
'♦Y^�
vI C
m
> o
050566
5z}
v+%
m(/)
aow 'cc
az�
V��-
v
v CA`nen
°'
�'0�
'=aa
r
ct
o
� .�
^ v
04
x
o v i_
o
W W
to to
> Ii W
� �
\ �
a
o
0
O
B
67 PEACHTREE LANE
(L0' 73 SHERMAN PINES SUBDIVISION)
..k
TOWN OF QUEENSBDR,
BUILDING & C
Reviewed DES DEF
Date:. _
PROPOSED PLOT PLAN
1" = 10'-0"
GENERAL NOTES
INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM
A SURVEY DRAWING PREPARED BY VAN DUSEN AND STEVES
LEGEND
- - - - - - - PROPERTY UNE
----------------------- PROPERTY UNE SETBACKS
----------- 330 ---------- EXISTING CONTOURS
330 NEW CONTOURS
—E —E E —E UNDERGROUND ELECTRIC SERVICE
— ss —ss ss —ss SANITARY SEWER
-- w —w w —w WATER SERVICE
----------E/P EDGE OF PAVEMENT
ACTUAL LOT SIZE: 10,537 SF
ACTUAL FRONTAGE 011 PIE CHTREE LANE: 125.83'±
PROPOSED ADDITION
34'-4"±
12'-0"
22'-6"
43'-3"
28'-0"±
62.796
No.1 DESCRIPTION L21
REVISIONS
SITE
DATA
PROPERTY ZONING
CLASsinCATION:
MDR MODERATE
DENSITY RESIDENTIAL
MINIMUM Lor SIZE:
2 AC-RES/1
ACRE PER DWELLING
UNIT
MINIMUM LOT WIDTH: 100 FEET
TAX MAP NUMBER:
301.18--1-55
5EXAM
W
REQUIRED
EXISTING
MON T
I_—
30'-0"
35'-1"±
SIDE
sn
10'-0" MIN.
22'-0"±
CL Z
_
30'-0" TOTAL
22'-6"±
REAR
USN
30'-0"
43'-3"±
MAXIMUM BUILDING
HEIGHT
40'-0"
28'-0"±
MINIMUM PERCENT
PERMEABLE
50%
78,296
ACTUAL LOT SIZE: 10,537 SF
ACTUAL FRONTAGE 011 PIE CHTREE LANE: 125.83'±
PROPOSED ADDITION
34'-4"±
12'-0"
22'-6"
43'-3"
28'-0"±
62.796
No.1 DESCRIPTION L21
REVISIONS
WORK IS TO BE AS SHOWN &
NOTED AND IN ACCORDANCE
WITH MANUFACTURER'S
RECOMMENDATIONS, TRADE
ASSOCIATION PUBLISHED
RECOMMENDATIONS AND
GENERALLY ACCEPTED LOCAL
CONSTRUCTION INDUSTRY
PRACTICES.
4-4
N
NW
r
4�
N V
rA
U
D m Z
W
%ZF
W
I_—
vai
sn
a
CL Z
_
} U 0
USN
N
r--'
�aiLz
oLL
LL
QOtA-
z
J
to
W
00
N
E
p
w
O
C
r'
U `
wed
U
)-
ON
vwo
�=
Lon ca
opt �'
Firw
go—
'♦Y^�
vI C
m
> o
050566
5z}
v+%
m(/)
aow 'cc
az�
V��-
v
v CA`nen
°'
�'0�
'=aa
r
ct
o
� .�
^ v
04
x
o v i_
o
W W
to to
> Ii W
WORK IS TO BE AS SHOWN &
NOTED AND IN ACCORDANCE
WITH MANUFACTURER'S
RECOMMENDATIONS, TRADE
ASSOCIATION PUBLISHED
RECOMMENDATIONS AND
GENERALLY ACCEPTED LOCAL
CONSTRUCTION INDUSTRY
PRACTICES.
4-4
4�
0000
N
rA
z
sn
a
0
cd
o`
r--'
o'
N
CAD FILE NAME
ACAD\ESPER\C-2
SCALE
1"
DRAWN BY
DRAWING TITLE
PROPOSED
PLOT PLAN
DRAWING No.
C-1.1