Loading...
2011-109 TOWN OF QUEENSBURY • ' 4 � 41111111111114 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20110109 Date Issued: Thursday, October 18, 2012 This is to certify that work requested to be done as shown by Permit Number P20110109 has been completed. Location: 959 STATE ROUTE 9 Tax Map Number: 523400-296-013-0001-018-000-0000 Owner: RAYMOND HIPPELE Applicant: RAYMOND HIPPELE This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property ra.„P lattim owner of the responsibility for compliance with Site Plan,Variance,or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 F‘tpc$1 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20110109 Application Number: A20110109 Tax Map No: 523400-296-013-0001-018-000-0000 Permission is hereby granted to: RAYMOND HIPPELE For property located at 959 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RAYMOND HIPPELE Commercial Alteration $7,000.00 50 ACORN Dr Total Value DIAMOND POINT,NY 12824-0000 $7,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency THE MCCORMICK GROUP 743-9300 FAX 743-9338 1582 STATE ROUTE 9 SOUTH GLENS FALLS NY 12803-0000 Plans&Specifications 2011-109 (2)canopies over doorways 120 sq ft EACH $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,June 24,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To -, s !ueen ry• i ne 24,2011 Air t' . SIGNED BY L/ , for the Town of Queensbury. Director of Building&Code Enforcement • OFFICE SE e LY • m TAX MAP NO.,!1 ' J P 'f'ITNO. Io7. FEE PAIDi>- BLDG.&CODES APPROVAL ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application fur any structure other than the Principal Structure (house) to include, but not limited to: garage. shed. greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Shedsf ences. A PERMIT MUST 8E OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER_ ho n t C .� pI e 1NSTALLERI3UILDER: T-In• ( THr_ C,i4zv a ADDRESS: C151 o`•)�t c( �. ADDRESS. I S L PHONE NOS. 7' -Oc z-(2' PHONE NOS. 1_113- i 3r - 113 - LOCATION OF PROPERTY: SSS R o0'ic. SUBOMSION NAPE. E. --MT- .1)40.t_ LOCATION OF PROPOSED CONSTRUCTION AND OR INSTALLATION: --)0u1-1-1 cJ i . o s :L6 EST'MATEO COST OF CONSTRUCTION. S 1000.0b ANY OTHER ACCESSORY STRUCTURES ON PROPERTY" Nob IF YES.PLEASE LIST: CONTACT PERSON FOR EUILCINO&CODES CCMFI.IANCF:111V1_ c ( c R Tt -i'. PrlON �!C" °L 1 — -- 1"FLOOR 2`0 FLOOR TOTAL • PROPOSED PROPOSED CONSTRUCTION HEIGHT SO.FT. i SO.FT. I SO.FT. FT.8 IN. OPEN PORCH DECK 3 SEASON.COVERED OR ENCLOSED PORCH' BOATHOUSE BOATHOUSE WITH SUNDFCK I DOCK • • SHED • POLE BARN DETACHED GARAGE(NO.OF CARS: ) C'Ct j'0!"'j a ti cr doer- OTHER ACCESSORY STRUCTURE' 'J A 7. r c. 1 2 0t-i - (6• .1 -CONSIDERED FLOOR AREA S MUST COMPLY WITH FAR[FLOOR AREA RAT1O1 REQUIREMENTS IF THE STRUCTURE IS I OCATr.D IN THE WATERFRONT RESID_NT!AL ZONE. To the best of my knowledge, the statements contained In the application, together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance.and all other laws pertaining to the proposed work shall be compiled with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes, an As- Built Surve by a lice ..- -y•r.drawn to scale showing actual location of all new construction. I nave read I -scree • e abo OR EMAIL Sagged ''I _ -• _ Dated!:. �,�J QUESTIONS? CALL 7614256 _ codes(queensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION Nan (Prr:tr2) Pt./41140A'p www.queensbury.net Commercial Final Inspection Report Office No.: (518)761-8256 Date Ins =ction e •: Queensbury Building&Code Enforcement Arrive: i •r / Depart: :i e0,• 742 Bay Road, Queensbury, NY 12804 Inspector's Initia s ._1 \-‘‘ ??E_VE. . NAME: T.- Rr RL._. Pu\?/ PERMI ' -- a° LOCATION:9.5151—A-17.. R w-TE_ct DATE: t — &— COMMENTS: Y N NA Chimney/'B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior!Exterior Guardrails 42 in. Platform/Decks Interior I Exterior Banisters 4 in.Spacing Platform I Decks Stair Handrail 34 in.—38 in./Step Risers 7"1 Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.wlLever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(181 Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers ex) E ,mEE0_ Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area ` ��� Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '.doors > 10%>1000 sq.ft. %Hour Corridor Doors&Closers Firewalls I Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft Wood Frame Attic Access 30"x 20"x 30'(h),Crawl Space Access 18"x 24' Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars!Sinks/Toilets Handicapped Bath!Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 In.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical al I Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide Th 't vg c l Okay To Issue Temp. or Permanent CIO . Okay To Issue C/C _ _ L:\Building&Codes FormssBuilding&CodesVnspection FormssCommerc ial Final Inspection Report.doc Revised January 7,2008 ■ ■ HAANEN ENGINEERING , LLP October 9,2012 21m Realty&Development Co. 959 State Route 9 Queensbury, NY 12804 Attn: Mr. Raymond Hippele, President Re: CWI Canopies HE Project No.251271 Gentlemen: Haanen Engineering conducted a visual review of the canopy construction at the CWI entrances at Mount Royal Plaza in Queensbury, NY. The framing structure had been constructed as per the plans developed by TMG, The McCormick Group. Hannan Engineering also verified that the framing structure is capable of supporting the snow load as indicated on the drawings. If questions arise,please contact me at(518)793-7444 ext.19. • Very truly yours, HAANEN ENGINEERING, LLP 41rja:/(IL 1r++J �t:i�w may., 14 • • a Daniel A. De Nero, P.E. . Principal *�a.si3{f mak► ,,/ 254 Bay Road,Queensbury,NY 12804 Tel:518-793-7444 Fax:518-793-7061 Email:hjh@hjhllc.com Commercial Ina Ins to e Office No.: (518)761-8256 Date Ins. =ction I=,u== = =• Queensbury Building&Code Enforcement Arrive: '' par---Fijairen 742 Bay Road, Queens• ry, NY 1281kt Inspector's Initials: IP p NAME: 1 o + .u< PE- LOCATION: '��'►l��l A €7 DA - / . t Kap f eS COMMENTS: Y N NA Chimney!'B'Vent!Direct Vent Location Plumbing Vent Through Roof 6'/Roof Complete Exterior Finish/Grade Complete 6'in 10'or Equivalent ✓ Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Banisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.--38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.wlLvver Handles l Panic : -re," i =uired Exits At Grade Or Platform 36(w)x • • (I)/Ca • i:c Equiv. Gas Valve Shut-off Exposed&Reg ..r : • ,. Grade Floor Bathroom Watertight l Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'A doors > 10%>1000 sq.ft ' Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete I Fire Dampers/Fire Doors Ceiling Fite Stopping,3,000 sq.ft Wood Frame Attic Access 30'x 20"x 30'(h),Crawl Space Access 18'x 24' Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars!Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicayped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 In.Beyond(Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'I Driveable Surface 20'wide Okay To Issue Temp.or Permanent CIO �E9 G , Okay To Issue C/C 1-6 C_--itsoZV'A*75 L:1Building&Codes FormssBuilding&CodesVnspec tion FonmssCommercial Final Inspection Report doc Revised January 7.20G8 G#0*(4 Re,PD Commercial Final Inspection Report 06. 7j ,j1q: Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart am/pm 742 Bay Road, Q nsbu , NY 12804 Inspector's Initials: f NAME: 0• a 1. PUVA PERMIT It: IO 1 I - 1 D I LOCATION: ''" q 3* +' DATE: to CCo e m AS LIZ-67_67 COMMENTS: Y N NA to kt i a Chimney/'B'Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6'in 10'or Equivalent Interior I Exterior Guardrails 42 in.Platform/Decks Interior I Exterior Banisters 4 in.Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. Ail Doors 36 in.wlLever Handles/Panic Hardware,if requited Exits At Grade Or Platform 36(w)x 44'(nlCanopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight I Other Floors Okay Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum Boiler I Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion -- a Ad Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/StoragelReceiving/Shipping Room(2 hr.), 1 6 doors > 10%>1000 sq.ft. 34 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft Wood Frame Attic Access 30"x 20'x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 In.Beyond[Both sides] Active Ling System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,If req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp.or Permanent CIO Okay To Issue C/C L:1Building&Codes FonmssBuiiding&CodesVnspection Forms%CommerciaI Final Inspection Report.doc Revised January 7,2008 , 2-2o S:u .e n sbury Qu ,250: :: Home of Natural Beauty...A Good Place to Live TOWN OF QUEENSBURY 742 BAY ROAD QUEENSBURY,NEW YORK 12804 518.761.8201 WWW.QUEENSBURY.NET September 19, 2012 Raymond Hippelle 50 Acorn Drive Diamond Point, NY 12824 Dear Mr. Hippelle: It has been brought to my attention that Permit 2011-109 for canopies over the rear exits in your plaza has not been closed out. Specifically you are required to obtain an engineer's signoff from the engineer of record before this Department can close out this permit. This letter will serve as FINAL NOTICE that if you do not obtain a signoff from the engineer of record within 14 days from receipt of this letter, a court summons will be issued for a violation of Chapter 88-24 for using these canopies as their intended purpose without obtaining the necessary approvals and Certificate of Compliance from the Town of Queensbury. If you have any questions, I can be reached at (518) 761-8253. Thank you for your anticipated cooperation. Sincerely, TO OF QUEE :URY ifi;i 4140 David Hatin, Director Building and Code Enforcement DH/mg Celebrating Our Sestercentennial 1762-2012 • E x►s- \\ c, M G1`kt, SU,-ice. n— . , -LAM" * 1. ' COPYFILE l.1EW \ "C'EL. �i�-rOlZG. , 11-1, SEE \iJkt -. sec-r,0,..) d o ) , " J\L :0 , LIr EC EaVEp • NEw D £AJ Tu el EL &TESL, Ex,s-N vk G JUN 2 2 2011 vqz,,... „ • nam x I. • S TOWN OF QUEENS= RY . BUILDING&CODES • .._ , _•_. __-__ BUILDING • V I1 3ased on our limited examinati. , ' ance with our comments shall not be constr d as E,xtSTihlt7 ndicating the plans and specifications re in `ull compliance with the Building Col 5 of h t\AN C, gem York State. S-f ss�,.1 I _‘,1-t S-TiAQG ZTN, j3UJLDNG & . 0+- _Reviewed B . af. ;: _._ _ __ tl vit I ._ -oUN'T ?.o\.?Nl- P L.A21q Cf\1015`( #3 •2,1• 11 t. DT r'v 5 c L-E. D l 2y GA. McTA,L Eoac P AAlLL • \ ..yam 0, i ROOF LOAD PER NYS BUILING CODE W/GROUND SNOW LOAD =50 PSFn E © E Y__ E 0 r ALL FRAMING 2'X 2''X1/4' SQUARE TUBE STEELALL JUN `Z 2011 WELDED -CONNECTIONS MIN.N/4'nFILLEBE T�WELDS TOWN OF QUEENSBURY LY EXIST a HANDRAILS BUILDING & CODES , if L illi EXIST CONC, ' RAMP 3/8"X 6"X 8" S { ANCHOR PLATE , • .. ., • , , �. • " , � 3/8" EPDXY ANCHOR -`'.N,(* BOLT - 6" EMBEDMENT 2 REQ'D PER PLATE SECTION A-A .z /- z--x, f 1/2"= 1'-G" G8- _ cp 3/8"X 6"X 8" A -. ANCHOR PLATE �— �_ _ - ID ° ° 3/8" BASE PL ° W/2 3/8" BOLTS 71 INTO WALK- eu 1/4"K 6" GUSSET TO BASE OF HANDRAIL i N 1 ° v o ° 41_ 4'-3' - S'-4" --y -- 5'-4" .. PLAN A -" 1/2"= 1'-0" MACE ENGINEERItVG,P.C. MOUNT ROYAL PLAZA HANDICAP RAMP 1;•.! HAVItAND ROAD ZIM REALTY&DEVELOPMENT CO. ROOF • QUEENSBURY, NY 959 STATE RT 9,QUEENSBURY,NY ,a#11177 1• MD s t i � I i �i V ° ° �I r 01:13 V II T.Ml KENDRICK ROAD i , 4 � I I 1 CT�1 1 I ' m ®�¢n I I z,..1 V�. I u1 n 1 I r 1 I y Ct i I o n 2Y i� ---- - _` i ----------------- •I