Loading...
2011-343 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development -Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20110343 Date Issued: Monday, December 03, 2012 This is to certify that work requested to be done as shown by Permit Number P20110343 has been completed. Location: 1444 STATE ROUTE 9 Tax Map Number: 523400-288-012-0001-022-000-0000 Owner: ADIRONDACK FACTORY OUTLET CENTER, IN( Applicant: ADIRONDACK FACTORY OUTLET CENTER, INC. This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Co of ment or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110343 Application Number: A20110343 Tax Map No: 523400-288-012-0001-022-000-0000 Permission is hereby granted to: ADIRONDACK FACTORY OUTLET CENTER. INC For property located at: 1444 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ADIRONDACK FACTORY OUTLET Commercial Alteration $5,000.00 1444 STATE ROUTE 9 Total Value $5,000.00 LAKE GEORGE,NY 12845 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2011-343 commercial alteration of public bathrooms $147.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,July 18,2012 (If a longer period is required,an application.for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the wn o (2uee s u do July 18,2011 SIGNED BY for the Town of Queensbury. urY• Director of Building&Code Enforcement FFICEUSEONLY-.� _ Eyu- ' TAX MAPFJUL .14 24111 NO. PFRI�AIT NO._ 1 FEES: PERMIT t L[�✓_ RECREATION -------.-.-..-.ENGINEERING---.---- (If applicable) OWNOF( � PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUII/L�DER: Al-L' �IYt �'[j� Yj&2 /��` p�ER: I�{&-1 ADDRESS: I7 yy s'l �}� %1 t-[r ADDRESS: � cSy SJrL-6 ofQJ� PHONE NOS. f �- Z/ (,� I PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: w �NE: LOCATION OF PROPERTY: / ::cnc � g HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑ YES &NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR o Q o d d LU 0 U PROJECT Of O O O I- _ w -, w LLLL w o Z_ z Q Q :- � N � ~OLL FOLL a206 SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- J MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:_ r(/yt(�(���(Jp /wLl /. ESTIMATED CONSTRUCTION COST:_ j ��)(� FUEL TYPE: HEAT TYPE: "HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: I ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? /W PROPOSED USE OF BUILDING OR ADDITION: ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I7O 1:11ease complete a separate Application for"Fuel Buming Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. . I .certify :that -the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the N.Y'. State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that.1/we are required -to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signedj� Director of Building & Codes: 761-8256 (for questions regarding.Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or,to schedule an appointment) ------------ Permission Is hereby granted to the above This application / proposed action described Applicant to er4ra 'the building herein is found to be in accordance with the % described hereince with said ; zoning Laws of the Town of Queensbury. Application: , , BUIL IN & C , _ ZONING APPROVAL DATE % DATE __.-__---- ------ ' - __-- ---- CQ:UEU::::D 256 OR EMAIL ry.net Office Use Only-, E INFORMATIONy.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Inspection Form Town of Queensbury Fire Marshal Periodic Inspection Date: I Time: U 742 Bay Road,Queensbury NY 12804 �Be-inspection V 518 761 8206/518 761 8205 CO Inspection Permit#: Fire Marshals Representative ;GK Palmer Business Name: Location: Stillman Contact: Wit% Type of Inspection N/A Yes NoL� C EXITS: Exit Access FC 1014&FC1029 Exit Enclosure FC 1020&FC1029 NOTES Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisie Width FC 1024/1025&FC1029.11 Secondary Aisle Width FC 1025&FC1029.11 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles In Equipment Rooms FC315.2.3 F.D.Si na e- FC 510 No Smoking Signs FC 310.3 / Stora a FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 L b 18" / 24" EVAC SIGNS IN Rooms FC 404.6 R1 &112 Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY Vacant Buildings FC 311 21 DAYS Insp OK NC DATE: OK NC SYSTEMS: FC 901.6 Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual L DATE: OK NC HVAC Shutdown —Sprinkler System Annual —Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6 -Annual Knox Box:Installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection -yoj-u-s Inspection Form Town of Queensbury Fire Marshal o Periodic Inspection Date: ]me: 742 Bay Road,Queensbury NY 12804 o Re-Inspection I bp 518 761 8206/518 761 8205 CO Inspection Permit#: 0 P —3 . Fire Marshals Representative MJ Palmer Business Name: C — r Location: " Ss GK Stillman Contact: A'�2 Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 P NOTES Ire A Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 �C Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 Secondary Aisle Width FC 1025&FC1029.11 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles In Equipment Rooms FC315.2.3 F.D.Sl na e- FC 510 No Smoking Signs FC 310.3 Storage FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 n Smoke Detectors FC 907 `3 CO detectors FC 610 j• �� dddd�����`""' Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6 R7 &112 Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY Vacant Buildings FC 311 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection [tesdoq- - Inspection Fora Town of Queensbury Fire Marshal CD Periodic Inspection Date: IZTime: 742 Bay Road,Queensbury NY 12804 o e-Inspection 518 761 8206/518 761 8205 CO Inspection Permit#: ire arshals Representative MJ Palmer Business Name: A .` ` Location: 1 q IL/ 10>i MC�-y �Gl( Stillman Contact: ' (C1L, Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 Sign:backu FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 .� Secondary Aisle Width FC 1025&FC1029.11 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles in Equipment Rooms FC315.2.3 F.D.SI na e- FC 510 No Smoking Signs FC 310.3 Storage FC 315.2 Compressed Gas FC 3003 J i Vehicle Impact Protection FC 312.1 �, �/� Lq Interior Finishes FC 803-804 =� 1GC-a !i Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 i 18" / 24" ��d�� k)FPKEVA i 3 �- Fuel SIGNS ar Rooms FC FC22 . &R2 Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 / Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY Vacant Buildings FC 311 -,, ,��, w/ 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown _ Sprinkler System Annual rJ Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 Operating Permit, 9 required will be issued after Completion of Inspection Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection Queensbury Building &Code Enforcement Arrive: /p Depart: V9q5 am 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: apjR. — M PER LOCATION: LI Ll 4.)-ry--iT E- Ro LTG °l . DA7 Yj ——7—17 COMMENTS: Y N NA Chimney/°B"Vent/Direct Vent Location Plumbing Vent Through Roof 6°/Roof Complete Exterior Finish/Grade Complete 6"in IV or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks l Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair HandraW34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s .ft. All Doors 36 in.w/Lever Handles/Panic Hardware, f required Exits At Grade Or Platform 36 w x 44°(1)/Canopy(I/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18° Above Grade Floor Bathroom Wateftht J Other Floors Oka Relief Valve,Heat Trap/Water Temp.I 10 Degrees Maximum Boiler/Fumace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil'Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/doors > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewails/Fire Separation,.2 Hour, 3 Hour Complete I Fire Dam rs/Fire Doors Ceilin 'Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30"x 20°x 30' h , Crawl Space Access 18'x 24" Smoke Vents Or Fan, if required Elevator operation and Si na e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped,Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond[Both sides Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if As-built Septic System La out Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C ►� �bj �L1� �� LABuilding&Codes FormslBuilding&Codes\lnspection FormslCommercial Final Inspection Report.doc Revised January 7,2008 Commercial Final Inspection Repo Office No.: (518) 761-8256 Date Inspectio e Itr ived: Queensbury Building &Code Enforcement Arrive: a Depart: a742 Bay Road, Queensbury, NY 12804 inspector's In" A NAME: rl PERMIT LOCATION: y DATE: d COMMENTS: Y N NA Chimney/'B'Vent/Direct Vent Location Plumbing Vent Through Roof 6'/Roof Complete Exterior Finish/Grade Complete 6"in IV or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.-38 in./SWp Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.wlLever Handles/Panic Hardware if required Exits At Grade Or Platform 36 w x 44'QyCanopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom WahwWht/Other Floors Okay Relief Valve Heat Trap I Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Sup&for Occu /Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dam rs/Fire Doors Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30' h Crawl Space Access 18"x 24' Smoke Vents Or Fan, if required Elevator operation and St /Shaft Sealed HandicapREd Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot SIgnage Public Toilet Room Handicapped Accessible HandIcapRqd Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond(Both S Tj%�K D©r`S K)o-F m f e I sides �i Q�p C--L c-=,P2 Fwoe- Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification if As-bulk Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access AN Sides by 20'/DHveable Surface 20'wide 04y To Issue Temp. or Permanent CIO Okay To Issue C/C LABuilding&Codes FormMuilding&Codeskinspection FamslCommerc ial Final Inspection ReporLdoc Revised January 7,2008 Rough Plumbing 1 Insulation Inspection Report r, Office No. (518) 761-8256 Date Inspection rrequ : L 1 Queensbury Building Code Enforcement Arrive:�aart: pm 742 Bay Road, Queensbury, NY 128.04 Inspector's Initial a NAME: PER LOCATION: INSPN: I -7 t-2 l I+q 4, f gAku . uv TYPE OF STRUCTURE: �S NV, N NIA Rough Plumbing/Nail Plates . PlumbingVent/Vents in Place 1 %inch minimum Drain Size WashingMachine Drain 2 inch minimum Cleanout eve 100 feet/change of direction Pressure Test Drain 1 Ven _ Air/ 5 ve highest connection for 15 minutes P saute Tfist,,,-' r PPIY Pipin ' eadr 15 minutes' Insulation I Residential Check I Commercial Check Tyvek or Similar Exterior Sealant Prop2r Vent, Attic Vent Door/Window Sealed No Insulation Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation ReporLrevised Nov 17 2003,revised February 15,2005, revised January 7,2008 [ � 3q3, . . bmN. a a my a VIM BURN ]n Ne ffona.. Easy S i►it a: i <e a ,d By ■ Corning Famous a P TOWN OF QUEENS URY Q Y BUI LDING DEPARTMENT:. Ba edo .ourlimitetl:examination,'co ple '"nce xMiour. Omments Shall"not be:cons. Uas in icatin . he plans and s edification in ful;compli .. t .1 . C d of: N w Yo ate. > faeosyff � , 3" r�rti^ar�r�n Ch#gieb'a Place : . . . . . Court. . • .' .. Under Armour Spring 2i}f2 . . Timberiand "� _IIll1 MIN II an JUL. 14 201 TOWN OF QUEENSBURY BUILDING &"CODES' ' lew Hallway Conneofing North,ri South Ends of Cente m FL 3330 S:q. Ft . 3200 S.d:Ft. . . ItInNegotiations Easy Spirit stairs 14 gty ' 638:4 S:q. Ft. �. .. . . �. . H4tt Corning 7050 Sq. Ft. Famous Footwear rb n cu "v 5 OQ Sq 1 Ft - ri In Negotiations U 14'Intedor . 3 ft entry, 44' i entrYhali. 44"entry hall. slnis 34'high !, i HCAccesS halhvay to t• tlen's Room .7•itwan I;<Emer.:Exit ' RUN . changing m v ?wastellne elation 8 sink area . 39-41� 990=1040 c ' 54 aifn � �y floor drain .12'max 1370 m�r 305 �21'imin E ` "iCfGS 3 delis• 32:x 60' _ Sa-llon 609.4 Ct to L3.. cso o' 5'x6'HC Stall mo • 3''was a Ilne'.: O cfaano angin� o e. 44'.entry hall — — — 34'.Hlgh S n — ro 1 HCAcess e. . 30• f, t CD P sink a� Stalls. v 30' waste Ilse: o _. . . y, a 4basement I d . ,01 E ;'�wast�Ilse' 30' i .r t —127 ^.4`.waste Ilne i9'6. mn 1525 � closet:- i 5'2`x5'HC stall 14"x5"stall 3' i aedlne 2"'vent'line. vent t 3'.Exit 9'6' T 9' Note.All 2'vents.wlli'be fled to 3'vent above cellingllne, E which will go thrpugh'roo