2011-293 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building & Codes (518) 761-8256
- CERTIFICATE OF COMPLIANCE
Permit Number: P20110293. Date Issued: Wednesday, July 13, 2011
This is to certify that work requested to be done as shown by Permit Number P20110293
has been completed.
Tax Map Number: 523400-290-006-0001-039-000-0000
Location: 5 PINECROFT Dr
Owner: JEFFREY LA PELL
Applicant: JEFFREY LA PELL
This structure may be occupied as a:
Septic Alteration Residential
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the f1
property owner of the responsibility for compliance with Site Plan, �n� a
Variance, or other issues and conditions as a result of approvals by the '' 7
Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
r TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20116293 Application Number: A20110293
Tax Map No: 523400-290-006-0001-039-000-0000
Permission is hereby granted to: JEFFREY LA PELL
For property located at. 5 PINECROFT Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JEFFREY LA PELL Septic Alteration Residential
TINA LUNDGREN Total Value
5 PINECROFT Dr
QUEENSBURY,NY.12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2011-203
septic alteration residential
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,June 20,2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer,
of the Town of Queensbury before the expiration date.)
Dated at the T.o�vn f Quee ury A/ ofida Jun_a 20,2011
SIGNED BY .S �' for the Town of Queensbury.
Director of Building&Code Enforcement.,
Community.Development Office D [ECEDWE
Town of Queensbury • 742 Bay Road • Queensbury, New York - 4
JUN 17
Office Use Only
e�7'70'. /--3 TOWN OF QUEENSBURY
TAX MAP NO. PERMIT NO. PE IT FEOU DIN(;R CODES
APPROVALS: ZONING TOWN CLERK
APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT; A PERMIT MUST BE OBTAINED
BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.
OWNER: S= � _ _�� INSTALLER:
ADDRESS: ADDRESS: ���I � �-�V� O ►Ml ��� �`—
PHONE NOS. t PHONE NOS._ `j 0 S
LOCATION OF INSTALLATION: e_i;BC �1 ►�+'c3�
RESIDENCE INFORMATION:
YEAR BUILT NO.OF X COMPUTATION = TOTAL DAILY FLOW
BEDROOMS Gallons per bedroom GARBAGE GRINDER
1980 or older X 150 = INSTALLED?
1981 -1991 X 130 = SPA OR HOT TUB
1992-present "�, X 110 p = INSTALLED?
PARCEL INFORMATION:
✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE
✓ SOIL NATURE: SAND LOAMA_ CLAY OTHER
✓ GROUNDWATER: AT WHAT DEPTH?
✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH?
✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL,(If well:water supply from any septic system absorption is: ft)
✓ PERCOLATION TEST: RATE IS Z . ~a PER MIINUTE PER INCH[mpi] (Test to be completed by a licensed professional
engineer or architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or
architect(unless installed in a�Planning Board approved subdivision).
TANK SIZE: O� GALLON( N I E IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder,
spa or whirlpool.tub.
SYSTEM E:
ABSORPTION FIELD(WITH NO.2 STONE) Total length ft. Each trench — — X �
PAGE PIT(S)(WITH NO.3 STONE) How many? Size?
�q, EAL'f RNAT�IVE SYSTEM Bed or other type?
❑ FOOL-1?JfNG TANK SYSTEM Total required capacity? Tank size? Number of tanks?
NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL
INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED.
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval
granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or
circumstance known by or on behalf of an applicant,shall be void.
I have its
e regulations w'h rge
this application and agree to
abide L
requ eTown of ueensbury QUESTIONS? CALL 761-8256 OR EMAIL
Sanitaosal in yt codesCa 4ueensburv.net
VISIT OUR WEBSITE FOR MORE INFORMATION
Si a u Person Responsible te.
www.aueensburv.net
�i Se tic Inspection Re ort
PP
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: Lil.-M am/pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:
NAME: a PERMIT NO.:
LOCATION: INSPECT ON:
RECHECK:
Comments and/or diagram
Soil Type: Sand/ oa la
Type of Water: Munid al/-Wftier
Waterline separation distance ft.
Well separation distance ft.
Other wells: ft.
Well Casing Length 50' +/- Y �A
150'to well required if NO
Absorption Field: Total length ft.
Length of each trench —�"
Depth of trenches
Size of Stone .1
Seepage Pits: Number
Size:
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box 2.
Distribution Box to Field Pit LL -rL
-Openinq Sealed: Y N
End Cap N
Inlet/0-u—tlek,'Pipes&Baffles N
Manholes 12"or less below grade _Y_N
[provide extension collar if Yes Y N
Location Separations
Foundation to tank ft. - `�� �'�✓
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan N � �f p � ��
Engineer Report and As-Built Y N Az;
ETU Maintenance Contract Y_N
provided
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
S stem Use Sta s:
Approved
Partial Approved and needs to be re-inspected, please call the Building&Codes Office
Disapproved
L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report-03 2910.doc
i
t
OR EXTREME ORGANIC L(
j
TYPE SPAS OR GARBAGE G
'
ROOF, F0077NG, GARAGE
'
1
DRAINAGE MUST BE EXCLUL
EX/S71NG WELL LOCATION
1
1 ASPHALT ::.
THIS DESIGN 1S SUBJECT TG
:DRIVEWAY
1
1
1
�
FIL_L. MATE' R%4L
1
1
AFTER REMOVNVG ORGANIC
ENTIRE AREA OF PROPOSED
�
E
1
1
"SYSTEM FILL" MATERIAL SH
11
SANDY LOAM OR SANDY
PERCOLA77ON RATE OF 3--4
OBJECTS OVER 1 * IN SIZF.
BE FINER THAN A NUM80?
'
'%�
EX/S 71NG 1000 GAL PRECAST
MATERIAL BY WEIGHT SHALL
Omm. LESS THAN 15
2.BE
i `,•- ,EXISTING TWO
CONCRETE SEPTIC TANK
N�
N
�
LARGER THAN A 1/2" Sit
BEDROOM RESIDENCE ' ;
T AND SEAL EXIS77NG
T
SEP71C TANK OUTLET
%J :
v
jma
SYSTEM
M FILL MATERIAL IS T
'
TO BE ABAND ELING SEP77C D 7EM
RE'MOVE
6" LIFTS W1771 TRACKED EQU
AECK
AS NECESSARY FOR NEW
TRENCHES.
SYSTEM INSTALLATION.
INSTALLER TO N077FY ENGI
SYSTEM FILL MATERIAL PRIOR
OIN
MATERIAL
REQUIRED TO PRO%
PUMP STATION MAY BE NATI
EXISTING
i
WHICH 1S NOT NECESSARILY S
PATIO �
'
00' WELL
M B'ACK Pr-r
l
PROPOSED 4" PVC SDR-35 EFFLUENT
EX13TING �
5WIMMIN6
1
1
"( h2'd¢ seen or nserved, or b8ii
SEWER, V PER FOOT MIN. SLOPE
Pooc !
�;� s� s�- -`1��� �s "t � ses, wells,
PROPOSED DISTRIBU770N BOX
I
1
S ,
i PROPOSED 2' WIDE ABSORP17ON
l
U:S�n. w
TRENCHES, 4 AT 40' REQUIRED
l
1
�
AS BUILT
-'
Y
l
F
ITOWN
�lV
1 OI"' UE
i
o�IS
-- �
'BUILDING &
evict ed Biel"
f
ate'
-
TAX MAP # 2!
I a=ROPERC '40 .,,,,.,�-
- ..--
ALTERATION OF THIS DOCUMENT
PROFESSIONAL
. uNfr 5E(BA N7$'22-..r""
ENGINEER IS A VIOLATi
187•08
SITE PLAN
4" M/N TOPSOIL OVER THE
EN77RE ABSORPTION FIELD,
SEED & ESTABLISH TURF
BACKFILL FREE OF
STONES OVER 3"
OVERFILL TO ALLOW
FOR SETTLEMENT
12" MAX
FIL TER FABRIC
MIRAF1 14ON
OR EQUAL
2' TRENCH WIDTH 6-12"
2" MIN.
oC
2" IN.
°
s"
12" MIN.
OO DO
°xopOo 0,0o
6"
O °<
3/4" TO 1-112" WASHED
3/4" TO 1
1 /2"
CRUSHED STONE
WASHED CRUSHED STONE
ABSORPTION TRENCH SECTION
NT5
ABSORPTION FIELD SECTION
NT5
SUGGESTED: POLYETHYLENE
APPROXIMATE EXTENSION TO GRADE WITH
FINISH GRADE TAMPER RESISTANT ACCESS
COVER
SLOPE
4" MIN TOPSOIL OVER THE EN71RE ABSORPTION
FIELD, SEED AND ESTABLISH TURF
FILTER FABRIC
MIRAF/ 140N OR EQUIVALENT
-4" PERFORATED PVC LATERAL,
SLOPE 1 /16" - 1 /32" PER FT.
ABSORPTION TRENCH PROFILE
NT5
12 "f
EXISTING HOUSE PRECAST CONCRETE
SEWER 3"
INLET " DISTRIBUTION BOX
MIN. SLOPE
LIQUID LEVEL OUTLET EFFLUENT SEWER,
1/4" PER FOOT
T MIN SLOPE
15"
BAFFLE -MIN.
WATERTIGHT ALL OUTLET INVERTS TO BE SET
F/
SLEEVE AND SEAL AT EXACTLY THE SAME ELEVATION,
(IMP.)CLz QLi USE SPEED LEVELERS
j o o PERFORATED TRENCH 4" PVC SOLID DPPPNNG,
ER TO
EXISTING 1 1/8" PER FOOT MIN SLOPE
GALLON SEPTIC TANK
J EXISTING SEPTIC TANK NOTES
VERIFY INTEGRITY OF INLET AND OUTLET BAFFLES, REPLACE IF
MINIMUM 2X WIDTH NECESSARY.
MAXIMUM 4X WIDTH
a PUMP TANK AND INSPECT FOR CRACKS OR OTHER DAMAGE AND
REPLACE IF NECESSARY.
ALL PENETRATIONS MUST BE SEALED.
EXISTING SEPTIC TANK DETAIL
NT5
END CAP
SITE SOILS DATA
PERCOLA770N TESTS
PT-1 - 6110111 BY T. HUTCHINS P.E.
STABILIZED PERCOLATION RATE: 2 MIN
50 SEC PER INCH
PT-2 - 6110111 BY T. HUTCHINS P.E.
STABILIZED PERCOLATION RATE: 1 MIN
55 SEC PER INCH
6" MIN.
WASTEWATER SYSTEM DESIGN
2 BEDROOM RESIDENCE
DESIGN TO 3 BEDROOM RESIDENCE
WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX.
FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
SEPTIC TANK - EXIS77NG 1000 GAL PRECAST CONCRETE
LEACH FIELD - PIPE IN STONE ABSORPTION TRENCHES
DESIGN PERCOLATION RATE = 1-5 MIN/IN
APPLICATION RATE= 1.2 GPD/SF
ABSORPTON AREA REQUIRED= 275 SF
2' WIDE TRENCH LENGTH REQUIRED 138 LF
USE 4 TRENCHES AT 40' LONG (160 LF)
POTABLE WATER SUPPLY TO BE EXISTING ON -SITE WELL
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN
ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH
INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION
OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC
TANK LEACH FIELDS.
AFTER EXCAVATION OF 2' WIDE TRENCH TO THE DEPTHS
REQUIRED, THE WALLS AND FLOOR OF EACH TRENCH SHALL BE
CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS
OF TRENCH.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER
FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED
TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE
O � [)RIVE
�� , �//� MATERIAL IN THE STONE AND PIPE.
PI NECR THE PIPE SHOULD BE LAID AT THE GRADES INDICATED,
MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS,
HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS.
PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES.
- - - - - - - - ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL
AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL
225.95' R= 793.95 FIELD.
d=16-18 22
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA
AFTER PIPING HAS BEEN INSTALLED.
THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES
AND IS NOT DESIGNED TO ACCOMODATE EXTREME WATER USE
OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZZI
t �
TYPE SPAS OR GARBAGE GRINDERS.
1
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER
t �
DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM.
1 EXISTING WELL LOCATION THIS DESIGN IS SUBJECT TO STATE AND LOCAL APPROVALS.
I
1 A5PHALT i
1 DRIVEWAY FILL MATERIAL NOTES
AFTER REMOVING ORGANICS, PLACE SYSTEM FILL OVER THE
EN77RE AREA OF PROPOSED FILL.
1 I "SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND
1 1
1 I SANDY LOAM OR SANDY LOAMY GRAVEL WITH IN -PLACE
1 I PERCOLATION RATE OF 3-6 MIN/INCH AND NO ORGANICS OR
1 1 OBJECTS OVER 1 " IN SIZE. LESS THAN 10i BY WEIGHT SHALL
t BE FINER THAN A NUMBER 200 SIEVE. AT LEAST 25% OF THE
1 I MATERIAL BY WEIGHT SHALL BE IN THE RANGE OF 0.50mm TO
1 EXISIING 1000 GAL PRECAST �0 2.Omm. LESS THAN 159 OF THE MATERIAL BY WEIGHT SHALL
t CONCRETE SEP77C TANK ti o BE LARGER THAN A 1/2" SIEVE.
EXISTING TWO CUT AND SEAL EXIS77NG vL:
t SEP71C TAOUTLET 110
NK SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN
1 BEDROOM RESIDENCE FAILING SEPTIC SYSTEM 6" LIFTS WITH TRACKED EQUIPMENT PRIOR TO INSTALLATION OF
I
1 PTO BE ABANDONED, REMOVE TRENCHES.
t DECK AS NECESSARY FOR NEW
1 SYSTEM INSTALLATION. I INSTALLER TO N077FY ENGINEER OF PROPOSED SOURCE OF
IN /� SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE.
�' I MATERIAL REQUIRED TO PROVIDE COVER OF SEPTIC TANKS AND
oao NOvy� I I PUMP STATION MAY BE NATIVE MATERIAL OR OTHER MATERIAL
Irn �0� �pG - > I WHICH IS NOT NECESSARILY SYSTEM FILL.
5� ..: EXISTING
PATIO
t SETBACK Pr- I
ExisriNG i-'hserved, or believe I saw
1 PROPOSED 4" PVC SDR-35 EFFLUENT 5WIMMING I I f^ ses, we11� y' Ape 1`
POOL I 1 I
t SEWER, PER FOOT MIN. SLOPE
1 PROPOSED DISTRIBUTION BOX I 17
t PROPOSED 2' WIDE ABSORPTON I i
t TRENCHES, 4 AT 40' REQUIRED
'TOWN OF QUE42, U,
i
ate: µ TAX MAP # 290.6-1-39
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED
OPERA_ _ - " _ PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.
jOBAGK N78,224�_-..+
t - LINE 5� .•-''�87•p8
SITE PLAN
1 ISSUED FOR PERMIT 6/1
SCALE: I "=20' 0 PRELIMINARY 6/1
MAP REFERENCE:
BASE INFORMATION FROM "MAP OF A SURVEY MADE FOR
PAULA & PHILLIP J. HASSON, JR." MADE BY VAN DUSEN &
SIEVES LAND SURVEYORS, 169 HAVILAND RD. QUEENSBURY,
NY 12804 AND DATED APRIL 20, 1989 AND "MAP OF
STONEHURST A SUBDIVISION DEVELOPED BY CHARLES &
BEVERLY MAINE" MADE BY VAN DUSEN & STEVES LAND
SURVEYORS, 169 HAVILAND RD. QUEENSBURY, NY 12804 AND
DATED JULY 15, 1983. ADDITIONAL FEATURES LOCATED BY
HUTCHINS ENGINEERING ON JUNE 13, 2011.