2011-328 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P201.10328 Date Issued: Monday, August 08, 2011
This is to certify that work requested to be done as shown by Permit Number P20110328
has been completed.
Tax Map Number: . 523400-297-017-0001-028-000-0000
Location: 39 MEADOW Dr
Owner: CHRISTOPHER& SUSAN GRANGER
Applicant: CHRISTOPHER& SUSAN GRANGER
This structure may be occupied as a:
Deck
By Order of Town Board
TOWN OF QUEENSBURY.
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, ,,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Coca Enfor ement
Planning Board or Zoning Board of Appeals.
TOWN. OF QUEENSBURY
Ld 742 Bay Road,Queensbury,NY 12804-5902 • (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20110328 Application Number: A20110328
Tax Map No: 523400-297-017-0001-028-000-0000
Permission is hereby granted to: CHRISTOPHER&SUSAN GRANGER
For property located at. 39 MEADOW Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: CHRISTOPHER& SUSAN GRANGI Deck $2,000.00
39 MEADOW Dr . Total Value
QUEENSBURY,NY 12804 $2,000.00
Contractor or Builders Name/Address Electrical Inspection Agency
Plans&Specifications
2011-328
192 sq ft deck
$50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES:. Sunday,July 22,2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Tow Queensbry; Freda ,July 22,2011
SIGNED BY for-the Town of Queensbury.
tvv,;r r d �a r
Director of Building ode forcement
,... .."___ F ICEUSEONLY_______________ E-C115 �^ v
✓ �
T,\X MAP NO. PERMIT NO. JUL Q 1 2011
FEE PAID BLDG. &CODES APPROVAL '
r
'--TOWWOE_ rE1 NSBURY_
AI;:CESSORY STRUCTURE BUILDING PERMIT APPLIC ILDING &CODAS"
U:;13 this application for any structure other than the Principal Structure (house) to include, but not limited to:
gaiage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-
SI"-?ds/Fences.
A I'IRMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID
PEJEMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT.
OV' NER:01VIJ g UcS�- �` FAY INSTALLER/BUILDER:
ADDRESS:
r I Q G�O�(� tf l ADDRESS:
R-IONE NOS. 7 q q I JT _ PHONE NOS.
LO:;ATION OF PROPERTY:' J I r ' 1�� � ��V SUBDIVISION NAME:
LO::ATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION:
Ec""IMATED COST OF CONSTRUCTION: $ 'R000 ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? y �S
IF'r ES,PLEASE LIST:
CC:JTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE:
- sr ND PROPOSED
PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT
SQ.FT. SQ.FT. SQ.FT. FT.&IN.
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH*
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS: )
OTHER ACCESSORY STRUCTURE:
*CliNSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN
TI-F WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained in the application, together with the plans and
sprcifications submitted, are a true and complete statement of all proposed work to be done on the described
pray-nises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to
th4: proposed work shall be compiled with, whether specified or noted, and that such work is authorized by the
owner. Further, .it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of
Compliance,being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-
B¢a Ht Survey by a li se ury drawn to scale showing actual location of all new construction.
I hive read agree ea e.
QUESTIONS ? CALL 761-8256 OR EMAIL
Sigp d
' Dated: 1 �/f codes(&'gueensbury.net
VISIT OUR WEBSITE FOR MORE INFORMATION
Name/Title(Printed) /���r �''-'f ''%,� --. oltw- -fz-, www.gueensburV.net
Queensbury Building & Code Enforcement - Residential Final Inspection
Office 6�1o. (518) 761-8256 Arrive: am/pm Depart: am/pm
Date Inspection request received: Inspector's Initials:
NAME: ; PERMIT#: 13
,
LOCATION: DATE: �S
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/'B"Vent/Direct Vent LocationC
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete r
Platform at all exterior doors /
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more J
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches v
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate •—� r�
Gas Valve shut-off exposed/regulator 18 inches above grade l
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom: Il �!� ��/(►��
Outside every bedroom area:
Inter Connected: Battery backu : VV�iw
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area 1 e or]
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents /
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 s .ft. /1
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08;Revised 12/22/10
IwQueensbury Building & Code Enforcement - Residential Final Inspection 0- —,gpn,
�
��—
Office:N�O. (518) 761-8256 �, Arrive: am/pm De : am/pm
Date Inspection request received: 52 �I+ Inspector's Initials:
NAME: C1G� `CS 6sraj PERMIT#:
LOCATION: C ' ' v� DATE:
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road 1
Chimney Height/ 'B Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O Temporary/Permanent
LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08;Revised 12/22/10
WORK REQUEST
{ CLIENT:
ADDRESS: 3 '1
Of Northeastern New York, Inc. DATE:
4 Phillip Drive PHONE:
Malta, NY 12020
Phone: 518-330-7631 Fax: 518-330-7631 CONTACT:
TYPE OF PROJECT
QTY CATEGORY GALV BLACI< FIXED H ADJ H EXT
SKETCH OF WORKSITE
MAPPING OF POST
ROTARY GEARBOX OMS 125 CMS 200 OMS250 A 50
NUM# PSI CAPACITY ffDEPT HAMMER SINK
/i�0� a(J d7 /0/ '
a
SIGNATURE OF INSTALLER:
CUSTOMER'S SIGNATURE:
STRESS ANALYSIS
CUSTOMER: CH' IS
DATE: 06/25 "I DESIGN: DECK11176 REF: 11176101 . ZP1
SALESMAN # TOM 0
-------------------------------------------------------
MEMBER STRESS FACTOR COMPOSITE
TYPE SIZE FACTOR LOAD LOAD
-------------------------------------------------------
JOISTS 2X10 DEFLECTION 234 PSF
16" BENDING 180 PSF
SHEAR 159 PSF
COMPRESSION 203 PSF 159 PSF
BEAMS 2-2X12 DEFLECTION 378 PSF
BENDING 151 PSF
SHEAR 103 PSF
COMPRESSION 283 PSF 103 PSF
BOLTS 1/2" SHEAR 3616 PSF 3616 PSF
POSTS 6X6 STABILITY 878 PSF 878 PSF
-----------------------------------
TOTAL LOAD 103 PSF
DEAD LOAD 10 PSF
LIVE LOAD 93) PSF
-------------------------------------------------------
STRINGERS 2X12 DEFLECTION 91 PSF
BENDING 116 PSF
SHEAR 128 PSF
COMPRESSION 537 PSF
-----------------------------------
TOTAL LOAD 91 PSF
DEAD LOAD 10 PSF
LIVE LOAD 81 PSF
-------------------------------------------------------
TOWN OF QUEENSBURY 1 �" Copy
IBUILDING & CODES DEFT.
V.
Revievied
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
Based on our limited examination,compliance
with our comments shall not be construed as
indicating the plans and specifications are in
full compliance with the Building Codes of
New Yom State,
CROSS-SECTION
CUSTOMER -- GRANGER,CHRIS
DATE 06/25/11 REF DeckIII76
kN
tz
�i
x v S
x
y
SPORE- NAMC;:
123 STREET RD
CITY, ST
(800) 665 1212.
I -'qlgd'�
..........
IT
dI
i
1 .
Plan View, Iso(FrontRight,Top)View
............................— ---------
�J[ l l l l �l[II�ICI�'�116�1�1'L����� �lC ! !
I fflii '0111111111111
r _ _
-S.
-If
iL .........
Front Elevation Right View
��� I� �� •�� i� it �I � � �� �
ill �, I I :I '� 'ii i .i �f
it
I! ii I 1 I �i
L-L
rim
3EAM BEAM POST POST
LABEL LENGTH COUNT SPACING
A 151 911 3 7' 1 3/4"
Post spacing is measured center-to-center.
Depth of concrete footers --- 48"