2011-459 41" TOWN OF QUEENSBURY
742 BayQueensbury,NY 12804-5902 (518) 761-8201
� � Road, mY
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20110459 Date Issued: Tuesday, May 01, 2012
This is to certify that work requested to be done as shown by Permit Number P20110459
has been completed.
Location: 238 BAY Rd
Tax Map Number: 523400-302-012-0001-031-000-0000
Owner: KUBRICKY CONSTRUCTION CORP
Applicant: REGIONAL RADIO GROUP
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property /4
owner of the responsibility for compliance with Site Plan,Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
V,041 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20110459 Application Number: a20110459
Tax Map No: 523400-302-012-0001-031-000-0000
Permission is hereby granted to: REGIONAL RADIO GROUP
For property located at: 238 BAY Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: KUBRICKY CONSTRUCTION COR
269 BALLARD Rd Commercial Alteration $15,000.00
WILTON,NY 12831-0000 Total Value $15,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2011-459
354 sq ft commercial alteration- Regional Radio Group
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,October 14,2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town 9 Queensbu} ; , Ffi4ay4 Ober 14,2011
SIGNED BY k, for the Town of Queensbury.
Director of Building&Code Enforcement
r7 • OFFICE`7USE ONLY
TAX MAP NO. / — / ____/ i5- 1.--) ',I-4 ( _
`, PERMIT NO. I' i i--7 ,S \if Lir ('1
FEES: PERMIT RECREATION r< 1
ENGINEERING I ),
(If applicable) i ir
S' 0 9 2011
(��
TOWNOFOI
PRINCIPAL STRUCTUR ' : BUI(_blNrc EERY
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
' ! � 1 G i.. /� /41-0 APP�lCA�JTfBI;ILDEt�:/L., Alt O�'c f ' ,efi 16 JOWNER: bA C
Cj / S�" C)✓a a I
ADDRESS: I
f P� ADDRESS: 23 0 -37--
PHONE NOS.
��� Rc 7 ?
S-7 � PHONF.NpS. hg � C:4_- ,)
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: `A-rf ` :Ae r`" S''''4 'd'`
.�.•..ir► ��' PHONE: � �5
LOCATION OF PROPERTY: Z-3 U g
HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? 0 YES 0 NO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
APPLY TO YOUR z o ec cc cj a 0 I-
PROJECT o O co
'2-
w
C11 w -ILL � w = ¢ I-
0 -I-
Z < < i- u) NU) 0L~L I- LI- a. = otS
SINGLE FAMILY
TWO-FAMILY —
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE 35y _ cee 4/-4,-Acid
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER kk 46 (^0041k ii0 L Q1. -
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: �e (rb,,p,Q-- 1l
06 /Oil)
ESTIMATED CONSTRUCTION COST: �
7 ..5 0 ucJ . PUP TVPF• AA(
B 3-LGL 11-05
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all ewt
constructed facilities prior to issuqnce of a certificate of occupancy. ewly
I have read a d 9gree to t o ab.ve. 2
< t A /
or
Signed
li[4Director of Buildina & Codes: 761-8256 (for questions regarding Buildin Permi
codes or septic systems) 9 ts, construction
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit ro
application requirements or to schedule an appointment) p cess,
,-
,
Permission is hereby granted to the above
This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with
described herein in accordance with said the
Application: zoning Laws of the Town of Queensbury.
ai
BUILDI G & 7 S A ''PROVAL
4
ZONING APPROVAL
DAT
DATE
QUESTIONS? CALL 761-8256 OR EMAIL
Office Use Onl codesCc�pueensbury net
�^ VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issi,ari• X
•
`Feb. 7. 20 1 2izt 1 : 11FNMDIA, Watervliet, NVP.16751;'L� P_, _3/6��%4%;4,%'
,y,�j
MIDDLE DEPARTMENT INSPECTION AGENCY, INC_
h'
-1
(i:-3 (e,ort i that the electrical wiring to the electrical equipment listed below has been examined and is approved as
r; being in accord with the National Electrical Code, applicable governmental, utility and Agency rules iri effect on the date ',4
(j noted below and is issued subject to the following conditions. ,,*g!'
(t�, Owner: /1 / 7 <
c 238 BayRoad Date: 1 �:
;,,� 01/20/2012 x
i�)
• • Occupant: e
?) ame L cation: is
238 Bay Road I
��' Occupancy:
��?: Reno. Office Radio Station Queensbury,Warren Co. NY 4\.,
•:
Inspection Form is --
Town of Queensbury Fire Marshal C)Periodic Inspection Date?o''/'"� Time:
742 Bay Road,Queensbury NY 12804 o Re-Inspection
518 761 8206/518 761 8205 dill'CO Inspection Permit 11: 11 - I-169
Fir arshals Representative
MJ Palmer Business Name: ((Asa l AGI, (fl 0)9
Location: a 3y e,01/41 'g.oA�)
GK Stillman Contact: Clay
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020 8,FC1029
Exit Discharge FC 1024 II,FC1029
Locks and latches FC10081, FC1029.2
Sign:Normal FC 1011 &FC1029
-
Sign:backup FC 1011.5.3&FC1029.7.5 f ^^ �S
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11 j
Secondary Aisle Width FC 1025&FC1029.11CpsroP!t 7"
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906
EVAC Plan FC 404.6
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8 -'
Exterior FC 1006.3
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6(R1 &R2)
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATELY
Vacant Buildings FC 311
21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC Fie Manilla!Ylspsel� ';:npiote
Kitchen Suppression Semi Annual be Coda '�! rr
Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506 FLAY
Operating Permit, If required will be issued after re Mairshal
Completion of Inspection T f Qu ur �-w
Commercial Final Inspection Report C@640,"
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: 2'3s am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: a
NAME: LLJ/ 2. to ) PERMIT#: /7 /
//-
DATE: S C 2
COMMENTS:
Y N NA
Chimney/"B'Vent/Direct Vent Location
Plumbing Vent Through Roof 6'/Roof Complete
Exterior Finish/Grade Complete 6'in 10'or Equivalent
Interior!Exterior Guardrails 42 in. Platform/Decks
Interior!Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers T"I Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 in.w/Lev.r Handle./Panic Hardware, if required
Exits At Grade Or Platform 36(w)x44'(I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors
> 10%> 1000 sq.ft.
%Hour Corridor Doors&Closers "
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18'x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage ✓
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in.,Checkout 36"
Handicapped Ramp i Handrails Continuous/12 in. Beyond[Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access All Sides by 20' • - Surface 20'wide
Okay To Issue Temp. or Pe 4;;;0110
Okay To Issue C/C
L:U3uilding&Codes Forms Building&CodesUnspection Fo msiCommencial Final Inspection Report.doc Revised January 7,2008
f-rt Q140
Commercial Final Inspection Report (i)/FAO
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: /h am/pm . Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: `')/)-
NAME: P (vI al �j Baa( I-7 PERMIT#: /1-1 5-9
LOCATION: a 3g L� atraf DATE: T-a.t`r-ia
COMMENTS:
I N NA � o .
`
Chimney/'B'Vent/Direct Vent Location
Plumbing Vent Through Roof 6'/Roof Complete (1Qo t `(1 V-19 r%i(‘
Exterior Finish/Grade Complete 6"in 10'or Equivalent pp,, !�
Interior/Exterior Guardrails 42 in. Platform/Decks ate-OCo
Interior/Exterior Baffisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.-38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doom>3000 sq.ft.
MI Doors 36 in.w/Laver Handles/Panic Hardware,if required
Exits At Grade Or Platform 36(w)x44'(I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(181 Above Grade
Floor Bathroom Watertight/Other Floors Okay � l Q�Okay /4/ (/s ,�_-
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum ✓ r-A 4 /1./ �h,
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System /t P/14 > //
Fresh Mr Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors
> 10%> 1000 sq.ft.
Y4 Hour Corridor Doors&Closers
FirewaNs/fire Separation,2 Hour, 3 Hour Complete/Fire yet/ 4,,LA 4'- ""''
Dampers/Fire Doors J
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame 4)d 4.,,+-^
Attic Access 30'x 20'0 x30'(h),Crawl Space Access 18"x 24" C
Smoke Vents Or Fan, if required Add C/0ie1 Tl01a-
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets 41. flj
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in.,Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access Ail Sides ?0'J D Iea Ols Surface 20'wide
Okay To Issue Temp.or ennanent COI
Okay To Issue C/C
L:\Building&Codes Forms\Buiiding&Codes1nspection FormssCommercial Final Inspection Report.doc Revised January 7,2008
.(/`141')
Commercial Final lnspectiori eport
Office No.: (518) 761-8256 Date InsFction request received:
Queensbury Building&Code Enforcement Arrive: I/`3 am/pm Depart: am/pm
742 Bay Road,,Z ueensbury, NY 12804 inspector's Initials: 34- ,,�
NAME: IL /f/d _ � .1 PERMIT#: it—�1, /
V
LOCATION: �' � DATE: 2 -/C-- /2_
I
COMMENTS:
Y N NA
Chimney/'B'Vent/Direct Vent Location — —Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior!Exterior Baliisters 4 in. Spacing Platform I Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 in.wlLever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Supply for Occupancy 1 Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 ''doors
> 10%> 1000 sq.ft.
' Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire '
G2;)1"
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18'x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
HandicappedBathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in.,Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond(Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required _
Final Survey, New Structure/Flood Plain certification,If req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access AN Sides by 20'/Driveable Surface 20'wide
/V'
Okay To Issue Temp. or Permanent CIO
Okay To Issue C/C
L:\Building&Codes Forms Building&CodesUnspection FormsiCommercial Final Inspection Report.doc Revised January 7,2008
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p7�1 Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: !�
NAME: !V (� PERMIT#:
LOCATION: DATE: 2 — 8 /
COMMENTS:
Y N. NA
Chimney/'B'Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish I Grade Complete 6'in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior!Exterior Banisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers r/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 in.wlLever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36(w)x44'(I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air S for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/StoragelReceivinglShlpping Room(2 hr.), 1 ''A doors
> 10%> 1000 sq.ft.
' Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers!Fire Doors_
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30''x 20'x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in.,Checkout 38"
Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure t Flood Plain certification,If req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access AN Sides by 20'/ bSurface 20'wide
Okay To Issue Temp. or P anent CIO
Okay To Issue C/C
L:1Building&Codes Forms Building&CodesUnspection Fonns1Commerdal Final Inspection Report.doc Revised January 7,2008
Commercial Final Inspection Report O:ti ' /44t4
Office No.: (518) 761-8256 Date Inspec tioor9,request received: \_
Queensbury Building &Code Enforcement Arrive: l am/pm Depart: am/pm
742 Bay Road a = - sbury, 12804 ins s Initials:
NAME: / ham. ( """ ..r-�, PERMIT#:
LOCATION: i/ DATE:
COMMENTS:
Y N NA
Chimney/'B'Vent/Direct Vent Location
Plumbing Vent Through Roof 6"I Roof Complete
Exterior Finish/Grade Complete 6'in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Bafisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"I Treads 11"
Vestibules For Exit doors>3000 sq.ft
All Doors 36 in.wlLever Handles/Panic Hardware,if reguired
Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Supey for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 doors
> 10%> 1000 sq.ft.
"A Hour Corridor Doors&Closers
Firewalls I Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame -
/ ee/i jt
Attic Access 30"x 20"x 30'(h),Crawl Space Access 18"x 24" !�-
Smoke Vents Or Fan, if required 1/5
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage �,� q it /&- AL
Public Toilet Room Handicapped Accessible �
Handicapped Service Counters,34 in.,Checkout 36" Ace, ,, ��.1, C/-
Handicapped Ramp/Handrails Continuous/12 in. Beyond[Both
sides] rem d Ue-
Active Listening System and Signage Assembly Space
Final Electrical I Flex Gas Piping Bonded -�,
GA
Site Plan I Variance required //`� �, ' 'rt.- Y:5
Final Survey, New Structure I Flood Plain certification,if req. /�
As-built Septic System Layout Required or On File //Ac C Irianl -`•(f
i"
Building Number or Tenant Address on Building or Driveway 4' / �/�c ��
Water Fountain or Cooler —
Building Access AN Sides by 20'/Driveable Surface 20'wide
Okay To Issue Temp. or Permanent CIO l/
Okay To Issue C/C
L:\Building&Codes Forrns Building&CodesUnspecfion Fomrs1Cammential Final Inspection Reportdoc Revised January 7,2008
II
a-_ --7- 73.-7-._ _ _ -- - -- — - it-2151_ _
r P,'oc - 9 3.- II —•-
rack room- ;i.
ENTRY GWS - 3. TOWN OF QUEE - I •
G tZ - ca.. 3 Bt L.Hi OING . - NSB i I f;
oi
� .._
TOT - 35-3. `f E •
:t:: � `_• - i:� Jocks e,
4 ._.v. .. _ 1)1, ,
r :-.,
'ryTOWN OF QUEENSBURY t :/,
FURNACE BUILDING DEPARTMENT :�
., Based on our limited examination,complia ,,e �,
�
/ ! 1 with our comments shall not be construed :s ;/,
WO is r s! +C''� '''''' Av/A►��AravAr a. :r';'Iv .rL:i!,�I.�'''1�'.';ir1 j f III if- i •I.
/
FIlE
� NewY•N1 •tatestorage / REST REST n
'i 0o_ n d Vit.!'! .4
SALES . r• . a f:
traffic 0 a� r. ;
t r ,!� dt . 4`"
PA 0 station P _ ___.
w
0 0, manager ' ��oD. —"/
/N
r �
i /
Wwan.�; conference - , -Ig MM..
�
, .�
fi
0, SALES g�
r--1 .
0 v c"---:
3
P a ' z--- . 1 ________ Iii
, we sn
i /.)
----› 01,,,90 4, . Irr,
0
, __ v01%)141‘4 /,6"
r, . \ Li z. -
0 GSM kitchen v'
1
I
1/ 0, - -4,
Q
1, ifR/AP el! front ;; ' __ — ,
i OM ; l --- I I` y''
A
0, ,1 11 reception .--
Oit '
a�ii if/ liii ins 'l.oi'. Ai iis'Af ' A +� ii l,.Alr IV 411h//sys
. storage 1 REST II REST I 6 47. .
UTI'F4
traffic
qi4
i :: 7 .
! _`_�
.�..� ,�� manager � �� -, --- ,
Prob. DA
�
'. ! .Ii t '`I. 1 / , -
1 0 , ..- I f N
WCQL •
conference .
, 10,
i ..z4 ,
. ,,
,,
_ __,
/ 4-4/,
0
- � = . ; 47•
v.
II SiVis- 4' • .
X0 , 8" .
1 r---7\ • 6:
kitchen v .
% 1
(-66
,.... ..: tO l,; .tOt J Q
3
I
RR/AP of front i 0 ,
• office A
4 #1reception ., •--
/ s
/ :
1
i
August 30,2011
In an existing building at 238 Bay Rd. Queensbury we are proposing the building out of 4
studios. The existing space is approximately 374 square feet with one wall running east
to west/front to back of the building, from that wall we are building 3 dividing walls,all
walls are built from floor to 12ft ceilings with 5/8 sheet rock. The main wall will have 4
fire proof doors installed and 3 of the studios will have 3'x8' double glass windows and
the 4th with a 1'x8' double glass window. The three dividing walls will each have
21/2'x31/2' double paned glass windows. Within each of those studios we will install
recessed lighting.