Loading...
2011-517 TOWN OF QUEENSBURY too742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20110517 Date Issued: Wednesday, February 29, 2012 This is to certify that work requested to be done as shown by Permit Number P20110517 has been completed. Tax Map Number: 523400-302-018-0001-020-000-0000 Location: 24 HIDDEN HILLS Dr Owner: WILLIAM & MARGARET CANNEY Applicant: WILLIAM & MARGARET CANNEY This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, 141 Variance, or other issues and conditions as a result of approvals by the Director of Building&Cede En cement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110517 Application Number: A20110517 Tax Map No: 523400-302-018-0001-020-000-0000 Permission is hereby granted to: WILLIAM&MARGARET CANNEY For property located at: 24 HIDDEN HILLS Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: WILLIAM &MARGARET CANNES 24 HIDDEN HILLS Dr Deck $6,500.00 QUEENSBURY,NY 12804-0000 Total Value $6,500.00 Contractor or Builder's Name/Address Electrical Inspection Agency LUXBRUSH PAINTING COMPANY NY 12804-0000 Plans&Specifications 2011-517 256 sq ft deck $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, October 24,2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To QueenoIA ay,October 24,2011 SIGNED BY ♦ .. for the Town of Queensbury. Director of Building . Code nforcement / �FICE USE ONLY /./ / r I MAP NO. PERMIT NO. — S` Y •' FEE PAID SC— BLDG.&CODES APPROVAL , • ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONSiin ^WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: OLIO 141'► I��A IN� INSTALLER/BUILDER: t� �1�J to us I PA/lJT CD 11—)c- ADDRESS: �c ADDRESS: dL4t0��P`F1LCS De_ ADDRESS: 1 1t'fNc'I+ , C-;TIL L1r PHONE NOS. (5 I D/ )'‘? J v4-5- /� \ PHONE NOS. 3G3CG I I ICI LOCATION OF PROPERTY: QUA +JU�. NI SUBDIVISION NAME: f41 h 1)t 1 LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: rear 0-t' r arre. ESTIMATED COST OF CONSTRUCTION: $ `p I`JUL) ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? N 0 IF YES,PLEASE LIST: Z/- CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: (61 Lu yPHONE:_ O Z ✓6°6 III , ST No PROPOSED PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ.FT. SQ.FT. FT.&IN. OPEN PORCH DECK X56 3 SEASON,COVERED OR ENCLOSED PORCH* BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: ) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As- Built Survey by a licensed surveyor,drawn to scale showing actual location of all new construction. I have read and ree to the above. / QUESTIONS? CALL 761-8256 OR EMAIL Signed Dated:i°(6 fr codes@queensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION Name/Title(Printed) f (14" "(. -'1 ( www.queensburv.net Queensbury Building & Code'nforement - esid iai Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart l am/pm Date Inspection request received: Inspector's Initials: 041,('''U) NAME: rZii-7__ �i� PERMIT#: l7�, LOCATION: Z 4 n`t, tT f 1 � /DATE: 7 2g-- 2— TYPE OF STRUCTURE: \ Comments: Yes Ng N/A i 4" Building Number Address visible from road Chimney Height/13"Vent/Direct Vent Location /./( 0 1 ev- Fresh Air intake 3 inch Plumbing Vent through roof minimum 18 inches dt0 Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 38 inches or more Handrail Termination at Newell Post or Wall - /� _. -. - ) Interior/Exterior Railings 34 inches to 38 inches Deck Bracing I Handicapped Ramp Compliant -* Grade away from foundation 6 inches with 10 Beet �; -� - i \ 6 inch clearance to sill plate as Valve shut-off exposed/regulator 18 inches above grade �---- Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight i'Lt - ij'' -'1V‘ Safety glazing/Window in stairwells safety glazing — ►`� ` Interior Smoke Detectors/Carbon Monoxide Detectors __) Every level: Every Bedroom: _- --- Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no windowi_ �, Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum /- Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/' hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker _ Site Plan /Variance required js_---.. Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary 1 Permanent I L:1Building&Codes FormstBuilding&Codesllnspection FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 626/08;Revised 12/22/10,Revised 04/13/11 Iv ikiatikes Rough Plumbing / Insulation inspe To eport Office No. (518) 761-8256 Date Ins•ection r= • + ; r - •: Queensbury Building &Code Enforcement Arrive: + D i• / •art: Fir, a 742 Bay Road, Queensbury, NY 12804 Inspector's In ��► NAME: Oct Ater— PE IT #: / LOCATION: 4 J v' INSPECT ON: MK / TYPE OF STRUCTURE: t.,•• Y N/A Plumbing Vent 1 Vents in Place 1 '..6 inch minimum Drain Size Washin. Machine Drain 2 inch minimum ano = = , 100 feet/change of direction Pressure Test _ Air/Head - `—=� • •. above highest connection for 15 minutes / 4 • MPUs V -ulation/Residential Check/Commercial Check T ek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: . hisliwithimiii5„...445iAigninimiswv. Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 ,TP- 4'' 44 1 Corom Li;'try C -voirment Oftwe I 1 , 1 ,' t , . i PLOT PLAN Plot Plan: Show all existing and proposed structures. Indicate the setbacks of all structures and buildings from all property lines. SIDE PROPERTY LINE II - 11 • 1111 MOM NM 1 - 1111 _II IIIII 1EMANIM1111171111- 11111 I I' Id lim 1411 rill& Illialiiiiilled III I I m Ili II ml.pri 644111 illegme11111116 4/ iii Illi A ' MMIIIIIIIIIIINIM IlkIVIIMIMM 11111111 I MI ** I IIMMMOMMOMMVAMMIIIMMONZ4.111110011 I m Imm 0 MOMMININERAMMOM MMEMMINSIliumKVA II mg mummmitimtdonnumm satimumsza Lissminommosum 111111111011111111MAIIMUMMIUMMIUMMIMENINIMB linall24=11111ET.:! 11111111111111111111NEMENIMENNIIIMMININOWN AM* IIVIIIKIEMIMI I 412 Lk'. 1111r1/2111111111111TITITIMMIfikil LANIEMPIIIMMIgho o MI M MPAOMMIUM MOM UM 111181111.11 nnINMEMMISCD0 .cr EMI m 'Arm= m m sr imm cimummorommei = mg my/ Imilmmom opm mi ma 1111130N01 IMP 127 milrAi m WWII MEM II MOMMIIM Mmomm. III MO mill AVM Li MUM MEM. NOMMINN EMOMMOM11161 Iliorma au imatiliti billimmilis A t 11111 111111111.111111:111.1111111111111&11 I ... 0 .. immlimimmmiummumms. .......m.mmmil ... .....m... .. um.. ....m.... ..........a. 1 SQUARE . (Ct FT. SIDE PROPERTY LINE ...... Z II Canney Page 1 of 1 Canney -1-'1 3,01':: ,k ‘ Scalebar ler. NIkti1.Y'..4- 300feet i t — —. ilt ___- ----a-- 300fl The Town of Queensbury does not warrant the correctness or accuracy of this data or assume any responsibility for any explicit or implied uses. Town of Queensbury ia742 Bay Road Queensbury,NE 12804-5902 s http://gis.queensbury.netlpublicgis/printdis.asp 10/5/2011 PROPOSED FLOOR PLAN SCALE: 1/4" - 1'-0" EXISTING MOUSE NEW DOOR SWING DIRECTION REPLACES TO BE CONFIRMED EXISTING WINDOW BY G.C. O RAIL RGSTS - �--------------------f----- -------------------------- ---------------- CONFIRM STAIR LAYOUT W/ OWNER 4 SITE 6'-O'• �'-O" COND�TIOONS ol -11 to am EXISTING HOU: SHOWN SCHEM PROPOSED FRONT ELEVATION --------- --� 1 SCALE: I/4" z I' -O" ---- ---- BOLTED AND FLASHED LEDGER AND JOIST HANGERS AS PER CODE - CONNECTION DETAILS AT HOUSE TO BE REVIEWED AND COORD. BY THE G.G. PROPOSED FRAMING PLAN SCALE: 1/4" = 1'-0" ELEVATION ICALLY ONLY J DOOR STYLE, SIZE, D SWING DIRECTION BE CONFIRMED BY DECK RAILING LE TO BE IFIRMED BY G.C. AINTAIN PROPER FROST OVERAGE FROM GRADE :) BOTTOM OF FOOTING CONT, RIM JOIST -1'-S" 4 11 M 11'-O" -- RAILING POSTS ANCHORED TO FRAMING AS COORD, SY G.G. W/ RAILING DESIGN JOIST -TO -BEAM TIE AT EACH JOIST (3) 2x8 P.T. SYP "1 CONT. DROPPED SEAM W/ ANCHOR BASE AT PIERS \8" REINF. CONC, PIER AND FOOTING OR PRECAST PIER AS DETERMINED BY G.G. - 411 MAINTAIN PROPER FROST COVERAGE 6' BELOW GRADE TOWN OF' QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building Codes of New York Stag;, TOWN OF QUEENSBURY BUILDING & CODES DEPT. Reviewed B Date: c� PROPOSED SIDE ELEVATION SCALE: 1/4" : I' -O" PROPOSED PLANS AND ELEVATIONS z fD ur W Z3 l 1.1 } Q J 1 w _Q N DRALUN BY JBL DOCUMENT DATE PRINT DATE October 18, 2011 SHEET A-1 12:38 PM div z x?`rte � Q O V 0A X \ L PROPOSED PLANS AND ELEVATIONS z fD ur W Z3 l 1.1 } Q J 1 w _Q N DRALUN BY JBL DOCUMENT DATE PRINT DATE October 18, 2011 SHEET A-1 12:38 PM