Loading...
2011-411 A QUEENSBURY TOWN OF � 742 BayRoad,Queensbury,NY 12804-5902 518� )761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20110411 Date Issued: Friday, November 25, 2011 This is to certify that work requested to be done as shown by Permit Number P20110411 has been completed. Location: 736 GLEN St Tax Map Number: 523400-302-006-0001-053-000-0000 Owner: 736 GLEN STREET, LLC Applat Number: ASIA DELIGHT RESTAURANT 00 Owner: PLAZAGLEN L.P. This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property4 J- owner of the responsibility for compliance with Site Plan, Variance, or <( / ._.. other issues and conditions as a result of approvals bythe PlanningBoard 'o V pp Direct r of Building&COV- or Zoning Board of Appeals. 404% TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20110411 Application Number: A20110411 Tax Map No: 523400-302-006-0001-053-000-0000 Permission is hereby granted to: ASIA DELIGHT RESTAURANT For property located at 736 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PLAZAGLEN L.P. Commercial Alteration $150,000.00 C/0 HOFFMAN ENTERPRISES 25 CORPORATE Cir Suite 100 Total value $150,000.00 ALBANY,NY 12203-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2011-411 ASIA DELIGHT RESTAURANT $252.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, September 14, 2012 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T , f Queer,ury- % , esday,September 14,2011 � SIGNED BY4 for the Town of Queensbury. Director of Building&Code nforcement i � -CSt-167"1 �/(/^J / rIcE PERMITNO.USE ONLY TAXAP� /1.—_i_I • UG 15 2011 FEES: P �'�v �U RECREATION ENGINEERING (If applicable) " ' TOW BUID NC & IDES, PRINCIPAL STRUCTURE: APPLICATION FOR ZONING A - - • , I ING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. �j�,, & APPLICANT/BUILDER:/AA I 41 NIb . t --_ OWNER: ' `'*�' Le 6% 43fo enkeer 4* 13 2g ccgR Aore er-a,- ADDRESS: ADDRESS: I& � $16od -- '�—�12�L------ ,a to6An/Y AM 12203 PHONE NOS._-1 6/S— g0__/&_____ PHONE NOS. .—462 — Cr"--1 —_— CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: AN _G(. PHONE: J'/g' D_/1_05 LOCATION OF PROPERTY: 7& G) sr�—_/j HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? B YES 0 NO IF SO, INDICATE APPLICATION NO.ANP DATE OF APPROVAL: 21 2016 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT O OC Cl d w LL(— APPLY TO YOUR Z ice 0 co U) U w PROJECT 0 LjO . JO i a0 = _ W _1 u- LL LL Q � U LU ¢ ¢ i- co Nv/i LL I-II a = oes SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- 71 / /f );- I MERCANTILE `/ �� / � 20 _ i6T FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:_4514 rouisikr_ AU -1_ !-oa' ESTIMATED CONSTRUCTION COST: I SO�l l7O _ FUEL TYPE: Nlsr C314. HEAT TYPE: '6.19-- *HOW MANY FIREPLACE(S):_4_ AND/OR WOODSTOVES(S):__J\]]___ ZONING CATEGORY: VICA141 ARE THERE WETLANDS ON THIS SITE? _ Nd IS THIS A HISTORIC SITE? 14b PROPOSED USE OF BUILDING OR ADDITION: 114,. OUT- NU _41.17 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?_____ ARE THERE EASEMENTS ON PROPERTY? �E C12050S 14 -r _ i _t1 i i x .11.111 flt:peCU , PVJAI- 1('-200 I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have rea• and a• e t• the above. • Signe. A4//;7; -T7aT xigqi4dAir Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 v Revised 4/14/2010 , Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: i , Ai hi/ - ---- ° -------:UIl.',I G &CODE' A'''ROYAL ZONING APPROVAL -' 4_ii y AT DATE QUESTIONS? CALL 761-8256 OR EMAIL codes(a.queensburv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Operating Permit Issued: ___Yes ___No Occupancy Type: _ -,1.1"!..,1;---„._ . Construction Classification: —__ Assembly Occupancy Limit:_______ ____ Special Conditions: Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Inspection Form 6v Town of Queensbury Fire Marshal 0 Periodic Inspection Date: 1401-1///Time: 'O 742 Bay Road,Queensbury NY 12804 o Re-Inspection '/-( r 518 761 8206/518 761 8205 eV CO Inspection Permit#: —/ Fire Marshals Representative K J Palmer Business Name: a-Si a. Da-iuf j-r-- Location: 'rlocation: 3(p C;t4- 61 GK Stillman Contact: Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 Secondary Aisle Width FC 1025&FC1029.11 / � . � ir.... \hp FIRE EXTINGUISHER: Hung FC 906 f LL V Y� ' Inspection of extinguisher FC 906 -_ 7 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 C .IVIPI 4 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 :: - ____ Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles in Equipment Rooms FC315.2.3 F.D.Signage- FC 510 No Smoking Signs FC 310.3 / Storage FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATEL7 Vacant Buildings FC 311 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Fire M lib ispr=v i;',n uilc.' I myb O me issued ' Wit Kitchen Suppression Semi Annual ui36k1?g& DON ;a' ,, Fuel Island Suppression Semi Annual Hood Cleaning 3-6-Annual a Knox Box:installed/checked FC506 ! 2 i I4IOperating Permit, if required will be issued after re Mar, -- I Completion of Inspection , �., K_T1.Qau 1 ary _ Inspection Form ;'F I , Town of Queensbury Fire Marshal O Periodic Inspection Date://"2C 2d Time: 2.— 7/ 742 Bay Road,Queensbury NY 12804 o Re-Inspection 518 761 8206/518 761 8205 o CO Inspection Permit#: /7—. l Fire Marshals Representative MJ Palmer Business Name: �S/CA- ,6(-`//CIA/ • Location: -...?-� (2,4--;L----- .Sit/ )(GK Stillman Contact: Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 , NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 �/ S/L h F- C:�-� Locks and latches FC1008& FC1029.2 G� ,w, �� Sign:Normal FC 1011 &FC1029 / / Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11TektiA.A) 046 Secondary Aisle Width FC 1025&FC1029.11 ,../ 14C 4 FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 ,------ EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 ?". Combustibles in Equipment Rooms FC315.2.3 )< LA.," Sr ,k; iL J . Pt-rfiei F.D.Signage- FC 510 • �- No Smoking Signs FC 310.3 ,/ Storage FC 315.2 ,- Compressed Gas FC 3003 ..,------ Vehicle Impact Protection FC 312.1 .1 Interior Finishes FC 803-804 Smoke Detectors FC 907 ------- CO detectors FC 610 f Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) ----"' Fuel Pump Warning Signs FC2205.6 ., Fuel Station Emer Procedures FC2204.3.5 / .. Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATEL] Vacant Buildings FC 311 / 21 DAYS SYSTEMS: FC 901.6 insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Kitchen Suppression Semi Annual /f�j a4,,..• � Fuel Island Suppression Semi Annual // ku--- <-' V Hood Cleaning 3-6-Annual6 ri:;? Knox Box:installed/checked FC506 C.� Operating Permit, if required will be issued after Completion of Inspection Commercial Final Inspection R .o rt • Offi No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart. am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: L_ l / f NAME: 5 ;t"i�.. "/� �1_ PERMIT /�"�l f LOCATI : �% =,,— . DATE: //-2.S.----77 COMMENTS: ,/ 1N NA Chimney/"B"Vent/Direct Vent Location `/ Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish I Grade Complete 6°in 10'or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior!Exterior Ballisters 4 in. Spacing Platform I Decks Vz Stair Handrail 34 in.—38 in.I Step Risers r I Treads 11" V Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.w/Lever Handles/Panic Hardware, if required a/! Exits At Grade Or Platform 36(w)x44'&Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum /' Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System V Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewatis/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24° Smoke Vents Or Fan, if required Elevator Operation and SIgnaje/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets r Handicapped Bath/Parking Lot Signage 4/ Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" a ‘A\ nd SignajRamp/Handrails Continuous/12 In. Beyond(Both /capped s ] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded (_‘.. ) Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,If req. As-built Septic System Layout Req fired or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access AN Sides 0'/D Surface 20'wide ( 0 OkayTo Issue Temp. ennanent V OkaTo Issue C/C '' •v„ LABuilding&Codes FormssBuilding&Codesdnspection Fonns1Commercial Final Inspection Report.doc Revised January 7,2008 I-- juedi.e.s42____) ._ Commercial Final Inspection Report ( ice No.: (518) 761-8256 Date Inspection ^►,y : Q nsbury Building &Code Enforcement Arrive: = . 4r'1.* r Depart: 2-71 m 742 Bay Road, Queensbury, NY 12 Inspector's In 4•1/214„_ ! / NAME: �4G�. i i PE f#: t// I/1— <'- LOCATION. 3 C �cDA i. /./-2: ✓/ COMMENTS: . Y N NA Chimney/'B'Vent/ rect Vent Location / - 4 f-47.-a) %LE_ c;,�y + P • ng V,, - h Roof 6°/Roof Complete yl 1J F�� `1-3 , 1 • Fin Grade Complete 6°in 10'or Equivalent V Interior a , '• Guardrails 42 in. Platform/Decks J Aq. I Exterior BaltPlatform isters 4 in. Spacing /Decks ✓ ✓// V',Q ik� LF'C_ 9,1 Stair Handrail 34 in.-38 in.I Step Risers r I Treads 11" I - �G i Vestibules For Exit doors>3000 sq.ft. 0 All Doors 36 in.w/Lever Handles/Panic Hardware,if required O \ t\ V'I Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv. Ca Gas Valve Shut-off Exposed&Regulator(18")Above Grade ' Floor Bathroom Watertight i/Other Floors Okay -----/ .WP - �:V-R�i Relief Valve,Heat Trap I Water Temp.110 Depress Maximum J Baler/Furnace EndOsure 1 hr.or Fire Extinguishing System V o T' Fresh Air Supply for Occupancy/Ventilation Combustion t 49 Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site `— Oil Furnace Shut Off at Entrance to Furnace Area c., Oil 4w27 vApi Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors c > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewatis/Fire Separation, 2 Hour, 3 Hour Complete/Fire / Dampers/Fire Doors .Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18'x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets . /7/ / Handicapped Bath/Parking Lot Sig Public Toilet Room Handicapped ' ►«r-rt', , V / Handicapped Service Counters, 36" Handicapped Ramp/Handra - • • I uousll2 in.Beyond(Both sides] / Active Listening System and Signage Assembly Space \\2-A p'� Final Electrical/Flex Gas Piping Bonded ��� Site Plan/Variance required S, Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File • Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler / .. Building Access AN Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp. or Permanent CIO Okay To Issue C/C L:Building&Codes Forms1Building&Codes Inspection FonnslCommerciai Final Inspection Report.doc Revised January 7.2008 /— tries Inspection Form Town of Queensbury Fire Marshal O Periodic Inspection Date:1/.23/f Time: 742 Bay Road,Queensbury NY 12804 o Re-Inspection 518 761 8206/518 761 8205 o CO Inspection Permit#: 1/— 7, Fire arshals Representative Mi Palmer Business Name: 5i . Location: <36' 6'P� GK Stillman Contact: Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Al kl eAlriS(,�A Sign:Normal FC 1011 &FC1029 Jet Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Z� 1 a6-Aa r-ia✓1,o( IIb16/bids Main Aisle Width FC 1024/1025&FC1029.11 �l Secondary Aisle Width FC 1025&FC1029.11l ee- FIRE EXTINGUISHER: Hung FC 906 1 f _�j „�}' Inspection of extinguisher FC 906 -3) 1 � ��� ��1L%/',D� in.J�'�--"°�- EVAC Plan FC 404.6 (/ /K_ 1icz /t J/4 TRUSS ID SIGNAGE FC 505.3 /Z�'� f' EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 ti Cepi�-+h�i rtl j Exterior FC 1006.3 `J Clearance to ElectricalncloFC 605. )moi c� il�n �' Electric Wiring Enclosed/Labeled FC 605.3.1 j/' +ly Combustibles in Equipment Rooms FC315.2.3 F.D.Signage- FC 510 d r-.l/ �!�^s/s, 4.1,1t�L/, No Smoking Signs FC 310.3 Storage FC 315.2 Compressed Gas FC 30034-k4 Vehicle Impact Protection FC 312.1 � G/N Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATEL] Vacant Buildings FC 311 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC K Kitcchenn Suppression Semi Annual �J�S Fuel Island Suppression Semi Annual F % 7C(17/Hood Cleaning 3-b Annual G/ Knox Box:installed/checked FC506 /14'G ` Operating Permit, if required will be issued after Completion of Inspection • N Commercial Final Inspection Report Office No.: (518) 761-8256 401 Date Irts '' n •,- •_ = •: Queensbury Building&Code Enforcement Arrive: I ID . �� _ Depart i • ) - pm �i/-� 742 Bay Road, Queensbury, NY 12804 Inspector's inrtaa, �. NAME: ��t R `=t (-AAT — PERMIT#: 1 __ 1 LOCATION: -1?,Co E2_ (=,\ ��.. DATE: y-- -- COMMENTS: Y/ Ni A Chimney/'B'Vent/Direct Vent Location — 1( N\N��I,NLt Plumbing Vit Thnugh Roof 6'/Roof Complete / rExterior-FinistO Grade Complete 6'in 10'or Equivalent \T—E_IA/2 Interior/Exterior Guardrails 42 in. Platform/Decks f Interior I Exterior Banisters 4 in. Spacing Platform I Decks Stair Handrail 34 in.—38 in./Step Risers 7"t Treads 11" Vestibules For Exit doors>3000 sq.ft. .f All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44'(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18')Above Grade i Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap I Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers _ Gas Furnace Shut Off Within 30 ft.or Within Line Of Site ,/ Oil Furnace Shut Off at Entrance e to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 4 doors > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewans/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq.fL Wood Frame Attic Access 30'1x 20'x 30'(h), Crawl Space Access 18'x 24' Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed / t/ jHandi capped Bathroom Grab Bars/Sinks/Toilets �/! Handicapped Bath/P \( 6 ✓ ublic Toilet Room Handicapped Accessible ✓/ Handicapped Service Counters,34 in.,Checkout 36" i/ Handicapped Ramp/Handrails Continuous/12 In. Beyond(Both / sides] ✓ — Active Listening System and Signage Assembly Space - Final Electrical/Flex Gas Piping Bonded / Site Plan/Variance required ✓,/ Final Survey, New St ucture/Flood Plain certification,if req. ��/ As-built Septic System Layout Required or On File C'ni.lic..�-Lyt1._\ -- • Building Number or Tenant Address on Building or Driveway 4' > f,,,C Water Fountain or Cooler / Building Access All Sides by 20'/Driveable Surface 20'wide ,/ Okay To Issue Temp.or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms<Building&Codes lnspec tion FonnsiComrr�inc ial Final i—►ra� s\t Report.doc Revised January 7,2008 0111116k FIRE MARSHAL'S OFFICE A_ TownQueensbury FOTOof Q J T 742 Bay Road, Queensbury, NY 12804 " Home of Natural Beauty ... A Good Place to Live " 11/22/2011 PUNCHLIST FOR ASIA DELIGHT • Grease duct test is completed by Fire Marshal w/ ADK P&M • Locks/Latches at rear exit must comply (thumb turn device) • Kitchen suppression is not complete—Witness test will be required, including: Air test for blow off caps Verify gas/electric shut off Verify activation of audible/Visual device Verify exhaust hood remains on and make up air is off(if required) Verify function of interlock for hood activation Verify"K"extinguisher installed • Remove all storage from rear mechanical room • Finish installing exit and emergency fixtures, and perform function test • Emergency Contact Form • Install all ceiling tiles • Verify seating capacity • Verify aisles and storage Fire Marshal 's Office • Phone: 518-761-8206 • Fax: 518-745-4437 fireniarslial@queensbury.net • wuna.queensbury.net Rough Plumbing / Insulation Inspection Nigrort Office No. (518)761-8256 Date Ins• - • Queensbury Building &Code Enforcement Arrive: >� ,j• 'art: . , ar pin 742 Road, Queensbu NY Bayry, 12804 Inspector's !nth- NAME: nth-NAME: if‘9/?4oL.. PER tT#.LOCATI N: �-`? � _ INS ECT ON: /0 --/71/ TYPE OF STRUCTURE: Y �N NIA Rouge Plumbing Nail Plates ,/" Plu •I . V- u Vents in Place 1 %in« minimum Drain Size ,✓, Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test ie .0; /Vent P.S.I 0 ft. above h'+hest connection for 15 minutes r; Test Piping P.S.I for 15 minutes Insulation/Residential Check I Commercial Check � �- �VI`VN‘3ka• Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed (No Insulation! Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003,revised February 15,2005, revised January 7,2008 7 -l/ GtiedGt Framing / Firestopping Inspection Report Office No. (518)761-8256 Date I .: i Queensbury Building&Code Enforcement Arrive::ntrcn- •-• 742 BayRoad, Queensbury, NY 12804 Inspector's Intim NAME: , /E'RMIT#. _11:4 LOCATI / (O c' c LI # 7/ !€ ���C INSPECT ON: l 111- TRUCTURE: Y 1MA COMMENTS: ss 22'x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 16(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trines 17- • = 6 ft. or less on center and water shield 24 inches from wall "r1C . Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side'inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 In. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuiIdNg&Codes Fortes-OLD\Building&Codes11nspection FonnssFrar►inp Firsstoppire Inspection Reportdoc Revised January 7,2008 Framing / Firestopping Inspection Repo '4-6(23 , Office No. (518)761-8256 Date i request received: C61?/).0 ,1 Queensbury Building&Code Enforcement Arrive::am/pm Depart l am/pm 742 Bay Road, Queensbury, NY 12804 inspector's Initials: .2c NAME: e- .t1 e 1L1 � �� ,20//-- 471f / PERMIT#: LOCATION: 7(e 6t�09c-e I INSPECT ON: fa 1 iii) i( TYPE OF STRUCTURE:_ � `r►� C ,.- 6 v s SCP F( 1 Framing Y /I ALA COMMENTS: Attic Access 22'x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w) 16 gauge(8) 16D nada each aide , Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Icgd�rate laid 24 inches from wall separation 1, 2, 3 hour —� 2 le 61/ Se-CdA !4y Fire wall 2, 3, 4 hour Fi _ /h�/r' � �� 7 wee Aping ! L Penetration sealed /•1 WO) // ,bac p . s �7 16 inch insulation in cavity min. f Garage Fire Separation House side's inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Bulidi g&Codes Forms-OLDBuUding&CodesJnspection Formscrsming FinebPPing Inspection Reportdoc Revised January 7,2008 Rough � �c g Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: /G/v', Queensbury Building &Code Enforcement Arrive: ,AJkJ am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:j��j- PERMIT #: LOCATION: 6 Ste-i e r INSPECT ON: /0/7/i TYPE OF STRUCTURE: _ Y N/A Rough Plumbing /Nail Plates ,'n /��- ;�/ 9 Plumbin Vent/Vents in Place ��� `' ` 7 1 % inch minimum Drain Size Washin. Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above his hest connection for 15 minutes II Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check r . T ek or Similar Exterior Sealant Proper Vent, Attic Vent .■■ Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Su, • for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insulation Report,revlsed Nov 17 2003, revised February 15,2005, revised January 7,2008 nof%%Ar%r CIOC PROPOSED HVAC PLAN 1/4"=1'-0" 1/4"=l' - 011 CEILING (TYP. L EXHAUST HOOD WITH MAKE-UP AIR UNIT LING P u CEILING (TYP. U. T 8'-4"t MENU BOARD SOFFIT - BOTTOM OF SOFFIT AT 7'-0" ABOVE FIN. FLOOR n C Lw RETURN AIR GRILL SUPPLY DIFFUSER FLUORESCENT LIGHT FIXTURE EXHAUST FAN (TOILET ROOM) 2'x4' SUSPENDED CEILING SYSTEM (KITCHEN 1<ILES TO BE ARMSTRONG CERAMAGUARD OR EQUIVALENT) COATED MINERAL FIBER SUSPENDED CEILING TILE lNo.1 DESCRIPTION I DATE REVISIONS WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. N Nw 1.� O 4 3 N rnc~ir Z�< () =Z U — W N cd Waw LLI n d to U Z 2 cn Z U to Q J In 0 O Ll O 3Z Jgoo 'J N�i_O W U Fm L moa 1. U }L( -4L O — Q UWO Z NZ cr)00 LO �w� ao o z ` ¢ .Q to t0 � to r 5 0 V Z yN 0D 00 Q. a Z ia, 0-0 �uw —0 V v g o '-aa Qp ^ p m - V O _ O+. Nd X o.E W (0 N > LL. w WORK IS TO BE AS SHOWN & NOTED AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, TRADE ASSOCIATION PUBLISHED RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL CONSTRUCTION INDUSTRY PRACTICES. CAD FILE NAME SCALE 1/419 /4" = 1 9-0" DRAWN BY DRAWING TITLE HVAC PLAN, REFLECTED CEILING PLAN AND DETAILS DRAWING No. A-3 / CD fV G) CD C CD CD co iJ C f C7 r� CD CA- m co r,- 0, D I rn X rn CO d Cl co 3 0 c 00 0 v _LJ 0 ry 0 N cd cn to O o � o G4 I CAD FILE NAME SCALE 1/419 /4" = 1 9-0" DRAWN BY DRAWING TITLE HVAC PLAN, REFLECTED CEILING PLAN AND DETAILS DRAWING No. A-3 / CD fV G) CD C CD CD co iJ C f C7 r� CD CA- m co r,- 0, D I rn X rn CO d Cl co 3 0 c 00 0 v _LJ 0 ry 0