Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2011-296
TOWN OF QUEENS-BURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20110296 Date Issued: Thursday, August 11, 2011 This is to,certify that work requested to be done as shown by Permit Number P20110296 has been completed. Location: 24 GENEVA Dr Tax Map Number: 523400-301-020-0001-072-000-000.0 Owner: CLUTE ENTERPRISES, INC. Applicant: CLUTE ENTERPRISES, INC. This structure may be occupied as a: Garage Attached By order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Cr „ Variance, or other-issues and.conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board`of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20110296 Application Number: A20110296 Tax.Map No: 523400-301-020-0001-072-000-0000 Permission is hereby granted to: CLUTE ENTERPRISES, INC. For property located at. 24 GENEVA Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction value Owner Address: CLUTE ENTERPRISES, INC. Garage Attached 6 HOLDEN Ave Single Family Dwelling $135,000.00 QUEENSBURY,NY 12804-0000 Total value $135,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2011-296 1300 sq ft single family dwelling with 480 sq ft garage $332.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,June.27,2012 (If a longer period is required,an applica' n for an exte sion must be made to the code Enforcement Officer of the Town of Queens be e theread �Aa Dated at the Town of e13 ® June 27,2011 SIGNED BY for the Town of Queensbury. Director of Building&_Code Enforcement y l % l a /OFF7Z� ONLY D' i TAX MAP NO. RMIT NO. FEES: PERMIT RE FEES: ; JUN 17 2011. - k,� (If applicable) ------ ---- Q�'' T PRINCIPAL STRUCTURE: APPLICATION FOR ZONING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID"PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: CkJ� C `J�e_ ADDRESS: ADDRESS: PHONE NOS. `7ciS -7a--7.7 PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: �4 G �c� �'r-, •'L So` .aO HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ' YES ❑ NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: .i'cx_ 1 %_7 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z It p co O W PROJECT 00 F_ O _j O CD CQ = _ o F_F U_- U `_ m <- O O V w 0 � �, C1 z Cl F— H O F_: F_ w z z ¢ ¢ CO Nuo OU_ F— LL 0. 1: 06 SINGLE FAMILY 2C TWO-FAMILY MULTI-FAMILY (NO.of UNITS_) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE( 2, ) OTHER Town of Queensbury*Community Development Office*742 Bay Road, Queensbury NY 12804 ' . T 3 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: t J'S�O<7Q FUEL TYPE: v-,O—k- Cif HEAT TYPE:Aorz-e_i -HOW MANY FIREPLACE(S):__(Z _AND/OR WOODSTOVES(S):_ _ ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? ` ,3 PROPOSED USE OF BUILDING OR ADDITION: i �,_ ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? J *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall. be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will o ertificate of occupancy. I also understand that I/we are required to provide s-built su ey by a licensed land surveyor of all newly constructed facilities prior to i ance of ace to of occupancy. I have read and agree the abo Signed Director Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office *742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 __________________________________ ____________________________________________ S Permission is hereby granted to the above S This application / proposed action described Applicant to erect or alter the building ; herein is found to be in accordance with the 00 described herein in accordance with said ; o zoning Laws of the Town of Queensbury. 11 Application: / ' 0 0 1 10 01 0 ' ' 0 ' 11 BUILDING &CODES APPROVAL ZONING APPROVAL 10 I ' ' 11 DATE DATE 01 11 QUESTIONS 4 CALL 761-8256 OR EMAIL codesCa)-gueensbury.net Office Use OnIV VISIT OUR WESSITE FOR MORE INFORMATION www.ciueensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury*Community Development Office"742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 OFFICE USE ONLY TAX MAP NO. PERMIT NO. PERMIT FEE APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. �7 OWNER �.� INSTALLER:ou`/ a_ t n�[� , L Ic- ADDRESS: ADDRESS: PHONE NOS. PHONE NOS. -793 737 7 LOCATION OF INSTALLATION: �Je_ RESIDENCE INFORMATION: YEAR BUILT NO.OF X COMPUTATION = TOTAL DAILY FLOW BEDROOMS Gallons perbedroom GARBAGE GRINDER 1980 or older X 150 = INSTALLED?_16� 1981-1991 X 130 = SPA OR HOT TUB 1992-present J X 110 = INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? ✓ BEDROCKlIMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH[mpQ (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: ` POC) GALLON(MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder,spa or whirlpool tub. SYSTEM TYPE: _ BSORPTION FIELD(WITH N0.2 STONE) Total length -L:t?Q ft. Each trench X 50 ❑SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? ❑HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by o behalf of an applicant,shall be void. 1 have read th egulations wi res ct to is application and agree to abide b ese and all req nts of own of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanita ewage D' os rd' ance. codes(&aueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION Si ur erson Res nsible Date www.aueensbury.net Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 r nCy Date received: /J NAME: (? LOCATION: PERMIT Final Survey Plot Plan Avvroved Denied The attached final survey has been received by the r/ Dept. of Community Development. Upon review the survey has been: Craig Brown, Zoning Administrator Notes: L:1SueHemingway\Building.Codes.Inspection.FORMS\Fina1 Survey Zoning Administrator.doc MAP REFERENCE SUBDIVISION PLAN & MAP OF A TOPOGRAPHIC SURVEY MADE FOR LARRY W. CLUTE BY. VAN DUSEN & STEVES DATED: JANUARY 29, 2007 LAST REVISED: AUGUST 15, 2008 LOT 16 pFC o _V,, El JUL 9 2011 C�� am - TOWN OF QUEENSBU Y BUILDING & CODES 31.6 Z 49.76 N84° 21' 11 W LANDS N/F OF BRUCE GENEVA DRIVE S34° 08' 45"E >09.66 NO DRIVE AT 32.5 TIME OF SURVEY PORpi 2 STORY WOOD FRAMED HOUSE (UNDER CONSTRUCTION) ' 23.9 LOT 17 Area 15000.00 sq. ft. 0.34 Acres 50.00 N84 ° 2''S9'„'W a ri CV)M ° 0 LANDS N/F OF BRUCE LOT 18 ■ / '�,. a & �� SievesRVEY Land Surveyors y New York 12804 169 Haviland Road Queensbur , (518) 792-8474 New York' Lic. No. 50135 h7NAUTHONZED ALTERATION OR ADDITION TO A SURVEY NAP BEARING A LICENSED LAND SURVEYORS SEAL Is A VIOLATION OF SECTION TY09, Sue -DIM" 2 OF ME NEW YORK STATE EDUCATION LAW.' THE OF THE DF ,HIS SURVEYORS ONLY COPIES ORIGINAL wvacED qTN AN OWCwAL OF THE LAND SueoEYDRs �s,ALL�SP roAEVA�>R �E�. CERTMATIONS INDICATED HEREON SION" THAT Tws SURVEY WAS PREPARED IN ACCORDANCE TMTH THE I"E)OSTS VEIYCODOF PRACTICE FOR LAND SURVEYORS ADOP7ID BY DIE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS SAID CER7IFICAADNS SHML RUN OALLY TO THE PERSON FOR TNTOU THE SURVEY IS PREPARED. AND ON MS BEHALF TO TK TITLE OWANY. 0OVERNW04TAL ACQICY AND LENDING INSTITUITION USTED HEREON, AND TD TME As9ONEEs OF TK �O JNSMTUr "' Map of a Survey made for Cody M. Fulmer & Anne M. Rhodes Warren Count New York Town of Queensbury, y, Date: July 2 11 Scale 1 "=20' S _ 1 p����� /� �7f7GG 1 1 {./� FULMO. / 500 1 - DWG. NO. 95C10 I - 17 N0. DATE DESCRIPTION r Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: T am/pm_ `��part: am/pm Date.Inspection request received: Inspector's Initials: "yc� NAME: �Lv PERMIT#: LOCATION: Q , DATE: TYPE OF STRUCTURE: Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification/Sticker on Panel Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Seal d or Glass Enclosure LOW �c Final Electrical Final Survey PI Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008;Revised 6/26/08; Revised 12/22/10 GRAINY Consulting, LLC 69 Hayden Point Loop; Diamond Point, NY 12824 518 221-3240 08/10/2011 CIute Enterprises,Inca 6 Holden Avenue Queensbury;NY 12804 Inspection Address: Lot 17-24 Geneva Drive,Queensbury NY 12804 Report Number: 0810111 Dear Pam: At your request, the Blower Door Inspection of the post construction test_to verify infiltration rate of the house as per requirements of the NYS 2010 Energy Conservation Construction Code of the above property,was. performed on 08110/2011. GRAJNY Consulting,-LLC is pleased to submit the following report. - The following data was provided- - Square Footage of the house-including conditioned basement= 1,924 SF Volume of the house,including conditioned basement=15,392 CIF Based on above,the following test data was collected: - Infiltration Rate,including conditioned basement at 50 Pascal=791 CFM - ACH50,Acuml Changes per Hour at 50 Pascal=791X60/15,392=3.1<7 , The Instruments used for test were provided by the Energy-.Conservatory Digital Gauge DG-3 rated.accuracy=+/-1%g calibrated minimum onceper year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there arc any questions. .�OF NEW Sincerely, Stan Grajny, PE m � NYS HERS Energy Rater BER-041 y NYS PE 065406-1 b 4r.)AS ' j� Z'.d d6g:U 6 6 M &V c Septic Inspection Report Office No. (518)761-8256 Date Ins onpquest received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: / NAME: �U f PERMIT NO.: l` � 1,`e LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal W!distance l Water Waterline separation ft. Well separation distance ft. Other wells: I ft. Well Casing Length 50'+/- Y N N/A 150'to well required if NO Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field Pit Opening Sealed: _Y N End Ca _Y N Inlet/Outlet Pipes&'Baffles Y N Manholes 12"or less below grade _Y_ N [provide extension collar if Yes Y N Location Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan N Engineer Report and As-Built Y N 11"J✓ �U/Lr 6✓U i L CJ ETU Maintenance Contract Y_N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear stem Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\13uilding Codes Forms\InspeMon Form\Septic Inspection Reporl`03 2910.doc Aug 1011 03:20p p•2 D 1 UN I Ilk � V V 6 f COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL C RTIFICATE - ELECTRICAL APPROVAL Permit No.....//.... 76.... , N. 2177Cut-in Card No..................................... .. ,p Owner..................�:�?... a ....� .Tl-'� .X.... .r ........................................................�................. Location. .7 ..................&s-lV11A PIZ G GGL�'�.................... ..... ......... ................. . ............. Installation Consistingof... .............../....�....j 3 J ................................r.... .................................................. ............ ................................. ............................................................................. ............................................................... InstalledBy......:I.....�.K... . i .........................................Lic.No................:.................................. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly.made for inspection. Inspectors of this Company shall have the privilege of maki ms ctions at any time, and if its rules are violated,the Company shall have the right vrvo Athipc,. teDate......�.:�®.r5.../............... INSPECTOR...... .............................................................. M-h-N RP_A__ Queensbury Building & Code Enforcement - Residential Final Inspe kh- IN- Offifice No. (518) 761-8256 Arrive:am/p Depart: am/pm Date Inspection request r cue' epd: Inspector's Initials: NAME: /%V PERMIT LOCATION: r7 DATE: TYPE OF STRUCTURE: Comments: Yed, No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracin /Handicapped Ramp Com liant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification/Sticker on Panel Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or qaqA EnclQsure Final Electrical / Final Survey Plot Plan Arc Fault Breaker Habit le Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding / p As Built Septic System/Sewer Dept. Inspection Sticker �✓���� 45 '�J Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08; Revised 12/22/10 Rough Plumbing insulation In Cation Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: C� NAME: PERMIT : 11-2 LOCATION: ;�4 INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rou h Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air]Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant P r- ent oor/Window No Insulation er Piping Insulation If r uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly1 No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 ,40� Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building 8t Code Enforcement Arrive:. am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: t LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comm n Y N N/A Footings Piers � Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this Mose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspecdon Forms\Foundatlon Inspecdon Reportdoc Last printed 12/20/2005 9:24:00 AM Rough Plurnb�ng An s �ti®n Inepec ion port Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 inspector's Initials:j-L& NAME: PERMIT;± : LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y I N N/A Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15;minutes Pressure Test Water Supply Piping Air I Head , r 15 minutes nsulatio Residential Check/Commercial Check T e or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed No Insulation Duct I Hot Water Piping Insulation If r uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape CONS. Rough Plumbing Insulation ReporLrevised Nov 17 2003,revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 128.04 Inspector's Initials: NAME: c PERMIT#: -�7(9 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough elumbing PNail Plates Plumblh~l Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation ReporLrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 © 1 - / Framing / Fir topping Inspection port Office No. (518)761-8256 Date Inspection request received: Queensbury Building 8r Code Enforcement Arrive: am/pm Depart:Q A w—am/pm 742 Bay Road, Queensbury, NY 12804 Inspectoet Initials• NAME: PERMIT LOCATION: INSPECT ON: - TYPE OF STRUCTURE: Y A COMMENTS: Framing Attic Access 220 x 3W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams _�\ Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s w 16 gauge 8 16D naus each side Draft stopping 1,000 sq.ft floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from.wall Fire separation 1, 2, 3 hour F' hour Firestopping PenetmfioKsealed 16 inch insulation in cavity min. Garage Fire Separation House side%Inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtvvall Windows Habitable Space/Bedrooms 24 In. (H) 20 in. (VV) 5.7 sf above/below grade 5.0 sf grade L Tuilding&Codes Forms-0LOSuliding&Codesllnspedion Fom*1Frwr4n9 Fir"doWng Inapedon Repoit.doc Revised January 7,2000 } Framing / Firestopping inspection Report -- Office No. (518)761-8256 E'n Queensbury Building 8r Code Enforcement p e ; Z a /pm 742 Bay Road,Queensbury, NY 126N NAME: — _ — PERMIT#: —Z LOCATION: LA A INSPECT ON: TYPE OF STRUCTURE: Y N A CO MMENTS: Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D name each sloe stopping 1,000 sq.ft floor trusses chor Bolts 6 ft. or less on center Ice and water shield 24 inches from.wall Fire separation 1, 2,3 hour Fire wall.2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceifinghyall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. 6.7 sf above/below grade 5.0 sf grade LABuiiding&Codes Forrns-(3 Zufiding&CodesUnspedion FonnNFrtming Firedopping hapsction Report.doc Revimed January 7,2008 Septic Inspection Re Office No. (518)761-8256 Date In o Queensbury Building&Code Enforcement Arrive: = e m 742 Bay Rd., Queensbury, NY 12804 Inspector's In NAME: � � — � PE IT NO.: —Z LOCATION: 7—LA— IN ECT ON: —7= RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft: Well Casing Length 50'+/- Y N N/A 150'to well required if NO Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Pi in Size Type Building to tank Tank to Distribution Box Distribution Box to Field Pit Opening Sealed: _Y N End Ca Y_N Inlet/Outlet Pi s&Baffles Y N Manholes 12"or less below grade Y_N �� �� 1 [provide extension collar if Yes Y NC Location I Separations - Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plo Y Engineer Report a As-Bu' ETU Maintenan ct _Y_N provided — Location of System on Property: ° Front Rear Left Side Right Side Middle Front Middle Rear stem Use S to Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Bu11d1ng Codes Fomms\Inspection Forms\Septic Inspection Reporl`03 2910.doc Septic Inspection Report Office No. (518)761-8256 Date Ins on est cei Queensbury Building &Code Enforcement Arrive: epart: G an / mD 742 Bay Rd., Queen�7ce Y 12804 Inspector's Initials.NAME: RMIT NO.: — LOCATION: NSPECT ON: RECHECK: Comments and/or diagram Soil T m Clay Type of Water: unici al ell Water Waterli a se rati ce ft. We aration distance ft. Other wells: ft. Well Casing Length 50'+/- Y N N/A 150'to well required If NO Absorption Field: Total length ft. Length of each trench ft. Depth of trenches 7= ft. Size of Stone See a e Pits: Number Size: x Stone Size: Piping Size Type Building to tank Hit Tank to Distribu ' Box LA ' Distribution Box to iel Pit " Opening Sealed: N End Cap N Inlet/Outlet Pipes&Baffles Y Manholes 12"or less below grade N p�RvJ� [provide extension collar' Y!N -- 'G R�1� U�Eb MOST Location Separations Foundation to tank �- ft. gE �V�v- -D Foundation to absorption ft. Separation of Pits Conforms as per Plo-tAaA, Y e 'F_7�-TE %tuO C-z�P� En ineer Report a As-Built _Y N e7V--- ETU Maintenance ct _Y_N <�' `Ta ' provided -* Location of System on Property: Front(Re;araL ft Side Right Side Middle Front <iddleear System Use S to ' Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\13uilding Codes Forms\Inspection Fortes\Septic Inspection Repoi#_03 2910.doc Foundation Inspection Report Office N o.(518)761-8256 Date Inspection request received: QuejMy Building 8t Code Enforcement Arrive: am/pm Depart:��- am,/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: . LOCATION: INSPECT ON: TYPE OF STRUC on i Crrl needs -/Z;l CJ 5"7F Footings MA pen%,. Monolithic Slab C5Lrd �,ke, Reinforcement in Place tl - The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place �, `A-I Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight.or Sump Footing Drain Stone: 12 inch width .6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior Rough Grade 6 inch drop within 10 ft. L:\Buliding&Codes Forms\Building&Codes\InspeMon Fomns\Foundatlon Inspemon Report.doc Last printed 12/20/2005 9:24:00 AM _ 1 T --. _:. - - -- - - . -__ . - �NN,K ,ova �a��__��a�.•_ - - -- --- - - �a a�a� OF x 2?6 REScheck Software Version 4.4.1 Compliance Certificate Project Title: 24X26 COLONIAL (1300) Energy Code: 2010 New York Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Glazing Area Percentage: 10% Heating Degree Days: 7635 Climate Zone: 6 Construction Site: Owner/Agent: Designer/Contractor: LOT 17 CLUTE ENTERPRISES,INC 24 GENEVA DR 6 HOLDEN AVE QUEENSBURY,NY 12804 QUEENSBURY,NY 12804 518-793-7277 Compliance: .. Compliance:5.7%Better Than Code Maximum UA:209 Your UA:197 The%Better or Worse Than Code index reflects how close to compliance the house is based on code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Gross • Assemblyor or •• Perimeter U-FaGtor Ceiling 1:Raised or Energy Truss 625 30.0 0.0 20 Wall 1:Wood Frame,16"o.c. 200 19.0 0.0 9 Window 1:Vinyl Frame:Double Pane With Low-E 30 0.330 10 Door 1:Solid 20 0.160 3 Wall 2:Wood Frame,16"o.c. 184 19.0 0.0 11 Wall 3:Wood Frame,16"o.c. 200 19.0 0.0 9 Window 3:Vinyl Frame:Double Pane with Low-E 15 0.330 5 Door 2:Glass 40 0.310 12 Wall 4:Wood,Frame,16"o.c. 184 19.0 0.0 10 Door 3:Solid 18 0.160 3 Wall 5:Wood Frame,16"o.c. 200 19.0 0.0 10 Window 5:Vinyl Frame:Double Pane with Low-E 30 0.330 10 Wall 6:Wood Frame,16"o.c. 200 19.0 0.0 12 Wall 7:Wood Frame,16"o.c. 200 19.0 0.0 10 Window 4:Wood Frame:Double Pane With Low-E 38 0.330 13 Wall 8:Wood Frame,16"o.c. 200 19.0 0.0 12 Basement Wall 1:Solid Concrete or Masonry 200 0.0 '13.0 10 Wall height:7.8' Depth below grade:7.0' Insulation depth:7.8' Basement Wall 2:Solid Concrete or Masonry 184 0.0 13.0 9 Wall height:7.8' Depth below grade:7.0' Insulation depth:7.9 Basement Wall 3:Solid Concrete or Masonry 200 0.0 13.0 10 Wall height:7.8' Depth below grade:7.0' Insulation depth:7.8' Basement Wall 4:Solid Concrete or Masonry 184 0.0 13.0 9 Wall height:7.8' Depth below grade:7.0' Insulation depth:7.8' Project Title:24X26 COLONIAL(1300) Report date:06/17/11 Data filename:\\Clutel\shared data\Clutel\Rescheck\GENEVA DR SUB-DIVISION\2011-LOT 17-24 GENEVA DR-QSBY-24X26 COLONIAL .rck Page 1 of 5 ,4 Compliance Statement: The proposed building design described here is consist i the bui ding plans,specifications,and other calculations submitted with the permit application.The proposed building h een designed d me the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.4.1 and to co with the mand a it ents listed in the REScheck Inspection Checklist. C— J �r(-z Name-Title ign Date 0 Project Title:24X26 COLONIAL(1300) Report date:06/17/11 Data filename:\\Clute%hared data\Clutel\Rescheck\GENEVA DR SUB-DIVISION\2011-LOT 17-24 GENEVA DR-QSBY-24X26 COLONIAL.rck Page 2 of 5 t REScheck Software Version 4.4.1 Inspection Checklist Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation. Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R 19.0 cavity insulation Comments: ❑ Wall 2:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 3:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 4:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 5:Wood Frame,16"o.c.,R-19.'0 cavity insulation Comments: ❑ Wall 6:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 7:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 8:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,7.8'ht/7.0'bg/7.8'insul,R-13.6 continuous insulation Comments: ❑ Basement Wall 2:Solid Concrete or Masonry,7.8'ht/7.0'bg/7.8'instil,R-13.0 continuous insulation Comments: ❑ Basement Wall 3:Solid Concrete or Masonry,7.8'ht/7.0'bg/7.8'insul,R-13.0 continuous insulation Comments: ❑ Basement Wall 4:Solid Concrete or Masonry,7.8'ht/7.0'bg/7.8'insul,R-13.0 continuous insulation Comments: Windows: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor.0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3:Vinyl Frame:Double Pane with Low-E,U-factor.0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 5:Vinyl Frame:Double Pane with Low-E,U-factor.0.330 For windows without labeled U-factors,describe features: Project Title:24X26 COLONIAL(1300) Report date:06/17/11 Data filename:\\Clutel\shared data\Clutei\Rescheck\GENEVA DR SUB-DIVISION\2011-LOT 17-24 GENEVA DR-QSBY-24X26 COLONIAL.rck Page 3 of 5 V #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 4:Wood Frame:Double Pane with Low-E,U-factor.0.330 For windows without labeled U-factors,describe features: #Panes Frame type Thermal Break? Yes No Comments: Note:Up to 15 sq.ft.of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements. Doors: ❑ Door 1:Solid,U-factor.0.160 Comments: This door is exempt from the U-factor requirement. ❑ Door 2:Glass,U-factor.0.310 Comments: ❑ Door 3:Solid,U-factor.0.160 Comments: Air Leakage: ❑ Joints,,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are either 1)Type IC rated with enclosures sealed/gasketed against leaks to the ceiling,or 2)Type IC rated and ASTM E283 labeled,or 3)installed inside an air-tight assembly with a 0.5"clearance from combustible materials and a 3"clearance from insulation. Sunrooms: ❑ Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum skylight U-factor of 0.75.New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Vapor Retarder: ❑ Vapor retarder is installed on the warm4n-winter side of all non-vented framed ceilings,walls,and floors;or it has been determined that moisture or its freezing will not damage the materials;or other approved means to avoid condensation are provided. Comments: Materials Identification and Installation: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Insulation is installed in substantial contact with the surface being insulated and in a manner that achieves the rated R-value. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R values and glazing U-factors are dearly marked on the building plans or specifications. Duct Insulation: ❑ Ducts in unconditioned spaces or outside the building are insulated to at least R-8. ❑ Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6. Duct Construction: ❑ Air handlers,filter boxes,and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and mechanically fastened. ❑ All joints,seams,and connections are made substantially airtight with tapes,gasketing,mastics(adhesives)or other approved closure systems.Tapes And mastics are rated UL 181A or UL 181B. ❑ Building framing cavities are not used as supply ducts. ❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. ❑ Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International Mechanical Code. Temperature Controls: ❑ Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Circulating Service Hot Water Systems: Project Title:24X26 COLONIAL(1300) Report date:06/17/11 Data filename:\\Clutellshared datalClutelXRescheck\GENEVA DR SUB-DIVISION12011-LOT 17-24 GENEVA DR-QSBY-24X26 COLONIAL .rck Page 4 of 5 Circulating service hot water pipes are insulated to R-2. Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Certificate:' A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window U-factors;type and efficiency of space-conditioning and water heating equipment. NOTES TO FIELD:(Building Department Use Only) Project Title:24X26.COLONIAL(1300) Report date:06/17/11 Data filename:\\Clutel\shared data\Clutel\Rescheck\GENEVA DR SUB-DIVISION12011-LOT 17-24 GENEVA DR-QSBY-24X26 COLONIAL .rck Page 5 of 5 . 2010 New York Energy Conservation Construction Code Certificate Insulation . Ceiling/Roof 30.00 Wall 19.00 Floor/Foundation 13.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.33 0.70 Door 0.31 0.70 Heating Cooling Heating System: Cooling System: Water Heater. Name: Date: Comments: Revised 4/14/2010 WINDOW SCHEDULE JOB SITE/ADDRESS: ��I' 'w <:c� �r`�J ' DATE: �- OWNER: APPLICATION NO.: WINDOW NO. WINDOW WINDOW UNIT OR STOCK ROUGH ROUGH SQ.FT. SQ.FT. CLEAR CLEAR SPECIAL OR LETTER MANUF. MODEL NUMBER OPENING OPENING VENT EGRESS OPENING OPENING HARDWARE ON PLAN NAME TYPE CALL SIZE WIDTH HEIGHT /CLEAR WIDTH IN HEIGHT IN OR OPENING INCHES INCHES INSTRUCTI o v ONS e .T �3 ?� o� Town of Queensbury* Community Development Office* 742.Bay Road, Queensbury NY 12804 Revised 4/14/2010 BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS Habitable Area of Required Actual light Required Actual Ventilation Square Foot Opening Remarks Room Room light square footage ventilation Square Footage for Egress In Square 8%of room 4%of room Feet area area -7 Town of Queensbury*Community Development Office* 742 Bay Road, Queensbury NY 12804