2011-286 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P2011.0286 Date Issued: Tuesday, August 28, 2012
This is to certify that work requested to be done as shown by Permit Number P20110286
has been completed.
Location: 56 MELDON Cir
Tax Map Number: 523400-289-020-0001.-030-000-0000
Owner: MICHAELS GROUP HOLDINGS,LLC
Applicant: MICHAELS GROUP
This structure may be occupied as a:
Fireplace By Order of Town Board
Garage Attached TOWN OF QUEENSBURY
Townhouse
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan,Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Co Enfo ement
or Zoning Board of Appeals.
TOWN OF iQUEENSBU.RY
742 Bay Road,Queensbury,NY 12804-5902 (518)16178201
Pf
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20110286 Application Number: A20110286
Tax Map No: 523400-289-020-0001-030-000-0000
Permission is hereby granted-,to:- TOWN OF OUEENSBURY
For property located at: 56.MELDON Cir
in the Town of Queensbury,to*construct place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NY,S Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: MICHAELS GROUP HOLDINGS, LI
10 BLACKSMITH Dr Fireplace
MALT' NY 12020-0000 Garage Attached
Townhouse $200;000.00
Total Value $200,000.00 "
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2011-286
.2025 sq ft townhouse with 417 sq ft garage& 1 fireplace
$467.55 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,June 22,2012
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration_date.)
Dated at the To n o ueens ry; a esday,June 22,2011
SIGNED BY ` V for the Town of Queensbury.
Director of Building&Code Enforcement
-------------------------------------------------------
ONLY '
TAX MAP NO. CJ y PE RMIT NO.
o� JUN 14 2Q11
FEES: PERMIT RECREATION ENGINEERING ;
(If applicable) TOWN OF QUEENSBU
-------------lt�--------------------- ---------------------- _-BLHLE)MC&-CODES=
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: THE M14iAfE f, CI rIMP OWNER:
ADDRESS: 10 BLAC1--AA%1 1 -DR, HA-LTA ,NY ►zo-L ?, ADDRESS: "
PHONE NOS. PHONE NOS. "
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: 'f• �(4�,x-ko PHONE: a6-1 -314 4
J
LOCATION OF PROPERTY: /S i��� . G L Lf C_l -c
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z
APPLY TO YOUR Z O d d W LL
PROJECT 0 a 0 O Cl) w
O O =
O W O" LL LL W ¢ a U
W 0 J LL O Z C7 H I- O I- C W
Z Q Q N(n 0LL HLL d206
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY(NO.�
TOWNHOUSE
4 6-1 s s6 Z oz- 5
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED / /
GARAGE(1,2,3)
OTHER
Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804
'f
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST:W Z 0n, 0 o O FUEL TYPE: ti A-S
HEAT TYPE? PHA. *HOW MANY FIREPLACE(S)___AND/OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: S►Nc,Le r—AM%x-%e rt6S�o�C.�
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY?
'Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I
certify that the application, plans, and supporting materials are a true and complete
statement/description of the work proposed, that all work will be performed in accordance with the
NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain
a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by
a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of
occupancy.
I have read and agree to t ab ov /" .
Signed
J /
Director of Building & Codes: 761-8256 (for questions CQUESTIONS? CALL 761-8256 OR EMAIL
regarding Building Permits, construction codes or septiccodes(M-nueensbury.net
systems)
OUR WEBSITE FOR MORE INFORMATION
Zoninq Administrator: 761-8218 (for questions regarding www•aueensbury.net
required permits, the permit process, application requirements or to
schedule an appointment)
-------------------------------
This application/proposed action described ; Permission is hereby granted to the above
herein is found to be in accordance with the Applicant to erect or alter the building described
zoning Laws of the Town of Queensbury. herein in accordance with said Application:
+ ,
,
I
0 ,
ZONING APPROVAL DATE o BUILDING &CODES APPROVAL DATE 01
----------------- -0 --------------------------------------------
QTown of Queensbury■ Community Development Office • 742 Bay Road, Queensbury, NY 12804
Fire Marshal's Office ; 01
Town of Queensbury • 742 Bay Road - Queensbury, New York ■12804 o r+ 0
S Date ip
Michael J.Palmer,Fire Marshal-Gary Stillman,Depuhj Fire Marshal ; ',
0
I
0------------_-
APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS
Application is hereby made to the Building &Codes Office for the issuance of a Building & Use Permit
pursuant to the New York State.Fire-Prevention & Building Code. The applicant or owner agrees to comply
with all applicable laws, ordinances, regulations,and all conditions that are part of those requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORTANT NOTE/TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED.
OWNER: /l�� l.�. C'OJ;� INSTALLER/BUILDER:
ADDRESS: IO iygk l.(S,,,- 4 Y i- �zI f ADDRESS:
PHONE NOS. 9 PHONE NOS.
LOCATION OF PROPERTY: ! / -c. bti �l --///C. SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: S
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:_r/l3/Chi l o C S(1t.- PHONE: 7—.3 14
✓ FUEL BURNING APPLIANCE _ WOOD COAL PELLET GAS OIL
INFORMATION
STOVE
FIREPLACE INSERT
FIREPLACE,FACTORY BUILT*
FIREPLACE,MASONRY
FURNACE(GARAGE ONLY)
*IF FACTORY.BUILT, PLEASE PROVIDE: MANUFACTURER NAME: r7�r.�s-)L c; . MODEL NO. $/-- 7 TW,
LISTED BY: y L NUMBER:
QUESTIONS?
CALL 761-8205 or 761-8206
CHIMNEY INFORMATION . BLOCK BRICK STONE OR EMAIL:
firemarshal(a)-pueensburv.net
MASONRY" CHECK ONE ✓ VISIT OUR WEBSITE
TILE STEEL SIZE IN FOR MORE INFORMATION
INCHES www.aueensbury.net
✓ ��
FLUE CHECK ONE x
DOUBLE -TRIPLE WALL INSULATED DIRECT VENT CHIMNEY
WALL LINER
CHIMNEY MATERIAL CHECK ONE ✓
r
**IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER.NAME: ��'} ! �S tLC MODEL NO. �G-7�✓t' T
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION 8,BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
, i. Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/grn De art: fl - am/pm
Date Inspection request received: // Inspector's Initials: /
NAME: r-0 cL PERMIT#:
LOCATION: 5 C-i r DATE:
TYPE OF STRUCTURE: • T d \[N .S L
a Comments:
Ye No NIA
4" Building Number Address visible from road V �J -
Chimney Height/"B"Vent/Direct Vent Location /`f
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant-,
Grade away from foundation 6 inches with 10 feet.
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing \
Interior Smoke De ors/Carbon Mpnoxid etectors �\
Every level: Every Bedrogfn: /
Outside every bedroom ay�a: ✓ /
Inter Connected: ✓ Batte ku ••--//bac
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft:150 s .ft.vents,, "\
Bathroom Fans if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification/
Floor truss,draft stopping finished basement 1,000 s .ft./
Emergency egress below grade /.
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to fumace area
FurnaceMot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
LOkay to issue C/C or C/G Temporary/Permanent
LABuilding&Codes FormslBuilding&Codesllnspectfon FormslResidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08;Revised 12122/10,Revised 04/13/11
GRAMY Consulting, LLC
69 Hayden Point Loop
Diamond Point, NY 12824
5.18 221-3240
08/09/2012
Mr.Joseph G.Dolan,Purchasing Manager.
The Michaels Group
10 Blacksmith Drive
Malta,NY 12020
Inspection Address:5 n Circle,Queensbury,N-Y-12805--/
Report Number:6809120
Dear Joe:
At your rcquest,the Blower Door Inspection to verify infiltration rate of the house as per
requirements of the NYS 2010 Energy.Conservation Construction Code of the above .
property was performed on 08/09/2012.GRAJNY Consulting;LLC is:pleased to submit
the following report:
The following data was provided:
Square Footage of the house,including conditioned basement=3,494 SF
Volume of the house,including conditioned basement=30,441 CF
Based on above the following test data was collected:
- Infiltration Rate,including conditioned basement at 50 Pascal=2,003 CFM_,..
- : ACH50,Actual Changes perrJiour_at 501?ii� 22,,003X60/3Q441=3 9<7---'
The Instruments used-for test were provided-by the Energy Conservatory Digital Gauge
DG73 rated accuracy=+/-1%,calibrated minimum once pet year:
Thank you for selecting our.company.We appreciate the opportunity to be of service:
Please call this office if there are any questions.
F NEW
Sincerely, ��P�E�Aus �f
Stan Grajny;PE w
NYS HERSEnergy Rater B -041
NYS PE 065406-1 Ep 0s54oe '
'°�bFEsslC/��
Final Survey Inspection
Dept. of Community Development'
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received: 3
NAME: M A d d's lTro(t p
LOCATION: 56 N) G yj o,,a cr
PERMIT M
Final Survey Plot Plan
Approved Denied
The attached final
survey has been
received by the
Dept. of
Community
Development.
Upon review the
survey has been:
Craig wn,Zoning Administrator
Notes:
L:\.SueHemingway\Building.Codes.Inspection.FORMS\Fina1 Survey
Zoning Administrator.doc
MAP REFERENCE
HILAND CROSSINGS
A SUBDIVISION MADE FOR
THE MICHAELS GROUP
BY VAN DUSEN & STEVES
DATED APRIL 15, 2009
LAST REVISED OCTOBER 15, 2009
FILED IN THE WARREN COUNTY
CLERK'S OFFICE ON NOVEMBER 6, 2009
HOA
HOA
Zo
5
LOT 13
#54
MELDON
CIRCLE
Z-"\
V`\ �Zd
�' Area
wo. s 7, 103.54 sq. ft.
•Oo 0.16 acres
01A �2
AS
LOT 14
#56
MELDON
CIRCLE
2 STORY
WOOD FRAMED
DUPLEX
2� R
ASPHALT
DRIVE
1D D� /
SPI`
LOT 15
#60
MELDON /
CIRCLE
/ LOT 16
#62
MELDON
CIRCLE
1
5� �dwoi-1,
a� u 'S e�
&D.
S
Land Surveyors
169 Haviland Road Queensbury New York 12804
(518) 792-8474 New York lAc. No. 50135
'UNAUTHORIALTERATION OR ADDITION TO A SURVEY
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
VIOLATION OF SECTION noa. Sue -DIVISION z OF THE
NEW YORK STATE EDUCATION LAW,'
COPIES FROM THE AL ORIGINAL OF THIS SURVEY
MARKED
MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS
SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.'
IS SURVEY WAS INDICATED HEREON SIGNIFY THAT
THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE
EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ZADOPTED ONAL
BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL
LAND SURVEYORS SAR) CERTIFICATIONS SHALL RUN ONLY
N THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND
ON HIS BEHALF TO TIE TITLECOMPANY, GOVERNMENTAL
AGENCY AND LENDING RiSTTUITION LISTED HEREON. AND
TO THE ASSIGNEES OF THE LFNOING INSTITUTION.'
Map of a Survey made for
The Michaels Group
Town of Queensbury, Warren County, New York
1latel August /, e01L!
Scale jZED W--
•�O,
MICHAELS
DWG. NO. 99312 14
N0.
DATE
DESCRIPTION
Report
Rough Plumbing I Insulation InspeC on
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depa am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: 4�Ck PERMIT
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout evey 100 feet/chan a of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
d .
50 P.S.I r 15 minutes
'tnsulation/ esidential Check/Commercial Check
T ek or Skhilar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly1 No duct tape
COMMENTS: — C'
��� �
�
Rough Plumbing Insulation ReporLrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
+ I
/0"
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: A Ilk, L MAPERMIT#:
LOCATION: , � INSPECT ON:
TYPE OF STRUCTURE:
comm elm
Y N N/A
Piers
ono ithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Fonns\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Framing / Firestopping Inspection Report
Office No. (618)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm r1kepa f,- am/pm
742 Bay Road, Queensbury, NY 12804 inspector's Initialsc'�
NAME:
PERMIT
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y A COMMENTS:
Framing
Attic Access 27 x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 161)naAs each side
Draft stopping 1,000 sq.ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from.wall
Fire separation 1, 2, 3 hour
Fire wall.2, 3, 4 hour <
irestopping ` !
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuild ft&Codes Fonnsd3LDOuli ft&CodesUnspeWon FemTrunirg Firedopping InspecOm Report.doc Revised January 7,2008
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Gas Fireplace/Stove Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# 11�2f6 Schedule Inspection l�%I Time 2, 5 am pm anytime Inspecto�t�
Name )&4 e L-5 �rOOaddress �(o ��/G�rn ( �'�'/�_. Rough In Final_
Appliance Manufacturer Model# \ V � ��� X1
Direct Vent Factory Built Chimney/ Flue Size-&'� Double Wail 1, Triple Wall Insulated
Yes No N/A Comments .
Floor Protection
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve � � �
Combustion Air
Hearth Extension(if any)
Mantel
Height above Vp opening
Witness Operation
Tank Placement(if LP)
01
CO Detection
CSST Bonding
White—Building Dept. Yello —Cust mer Pink—Fire Marshal
Rough Plumbing / Insul�tion` n ction Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart:•,am/pm
742 Bay Road, Queensbury, NY 128.04 Inspector's Initials�_�
NAME: &`CLe-,,[�; PERMIT#: �� a
LOCATION: INSPECT ON: /d Z` ���
TYPE OF STRUCTURE: R
Y N NIA
Ro h Plumbing/N I Plates
Plu -tent/ nts in Place
1 %inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent .V
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air I Head
50 P.S.1 for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or.Similar Exterior Sealant
Proper Vent,Attic Vent
Door I Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulaft Repotrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping In tie iotin Repo
Office No. (518)781-8258 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p�m Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
/ LI-11
NAME: PERMIT
LOCATION: INSPECT ON: — --�
TYPE OF STRUCTURE: �i
Y X N WA COMMENTS:
Framing
ss 27 x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 w 16 gauge 8 16D naus each side
Draft stopping 1,000 sq.ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from.wall
Fire separation 1, 2, 3 hour
F' 1.2, , 4 hour n
irestopping
on sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side's Inch or 5/8 inch Type X
Garage side 5/8 inch Type X U<PF2%5z— t ; —�—�
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H) ,
20 in. OM �TL
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes FomOLOSuildtng&CodesUnspeation FomssTrwWrrg Firsuopptnp Inap®dion Repwtdoo Revtrled January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: - am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: I l y
NAME: WqA r- PERMIT
LOCATION: INSPECT ON: l 1
TYPE OF STRUCTURE:
Y
Framing IVA COMMENTS:
� --
Attic Access 27 x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12°O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %N 16 gauge 8 16D naus each sWe
Draft stopping 1,000 sq.ft. floor trusses
Anchor Bolts 6 ft or less on center
Ice and water shield 24 inches from.wall
Fire separation 1, 2, 3 hour
Fire wall.2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Celfing1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
L:U3uilding&Codes Formsd3LDUSuliding&CodesUnspeftn FomielFnuning FlnstoWng Inspedon Repatdoc Revised January 7,2008
AD
rraming�Firestop Ing Inspection R port
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm
742 Bay(toad, Queensbury, NY 12804 Inspector's Initials:
NAME: A'rlln-'e-fr' r®Z9 PERMIT*
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: � ���tiT �
Y N I MA COMMENTS:
Framing - --
Attic Access 22"x 3T minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly,
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D naus each side
Draft stopping 1,000 sq.ft floor trusses
6 ft. or less on center
Ice and water sh Id 24 inches from.wall
2, 3 hour
Fire wall.2, 3, 4 hour �,,.,`�
Firestopping
Penetration sealed �' _ 7 —
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 518 inch Type X
Garage side 5/8 inch Type X
Ceilinghwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W).
5.7 sf above/below grade
5.0 sf grade
LASuitding&Codes Forms-0LOftlidinp&CodesNnspection FomwWwning FihstoWng Inspection Report.doc Revved January 7,2=
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building 8t Code Enforcement Arrive: am/pm Depart: am'/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's initials:
66: P-
NAME: PERMIT#: .
LOCATION: c INSPECT ON:
TYPE OF STRUCTURE:
on �
A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing 01
1
Foundation Waterproofing
Footing Drain Daylight-or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
ackfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R.
Rough Grade 6 inch drop within 10 ft.
L:\Buliding&Codes Forms\building&Codes\Inspection forms\Foundatlon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: andpm Depart:/2a
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:�—��
5pm
NAME: f i %/' PERMIT
LOCATION: �, ���'_ INSPECT ON: —
TYPE OF STRUCTURE:
Comm n
Y N N/A
Footings
Piers
�ab�
Reinformceme-nfin-Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place l
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing.Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\InspeWon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building 8c Code Enforcement Arrive: am/pm Depart: in . , pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: `
NAME: PERMIT Ih
LOCATION: - , INSPECT ON:
TYPE OF STRUCTURE:
Comm n
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place e r
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
.R-
Rough Grade 6 inch drop within 10 ft.
L:\Bullding&Codes Forms\Building&Codes\Inspetton Eons\Foundation Inspection Reportdoc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials��
NAME: &Leks, PERMIT#:
-- �
LOCATION: K6 INSPECT ON.
TYPE OF STRUCTURE:
Comm a
Y N NA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this se on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inch footing
6 l for et areas under slab
B
P1 bing Under Slab
/Cast/Copper
Foundation Insulation Interior/Exterior
.R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\InspeMon Forms\Foundation Inspecction Report.doc
Last printed 12/20/2005 9:24:00 AM
l �
a7�aio
N0073W VOH
Z9#
9L 107
/
/
.970a10
N0007.73W /
9L107 / \
l'o
/ t o
(01
_ IA
t� —
co
ch
O
T
� � 3aB9,9f9LN
w
` VOH
I
REScheck Software Version 4.4.1
Compliance Certificate
Project Title: TH138 Wakely
Energy Code: 2010 New York Energy Conservation
Construction Code
Location: Warren County, New York
Construction Type: Detached 1 or 2 Family
Building Orientation: Bldg.faces 45 deg.from North
Conditioned Floor Area: 1469 ft2
Glazing Area Percentage: 11%
Heating Degree Days: 7635
Climate Zone: 6
Construction Site: Owner/Agent: Designer/Contractor:
56 Meldon Circle The Michaels Group,LLC
Queensbury,NY 10 Blacksmith Drive
Permit Date:May 31,2011 Malta,NY
Compliance:
Compliance:2.6%Better Than Code
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or D..
Perimeter U-Factor
Foundation Wall:Solid Concrete or Masonry 388 0.0 13.0 20
Orientation:Front
Wall height:7.6'
Depth below grade:6.6'
Insulation depth:7.6'
Foundation Wall:Solid Concrete or Masonry 277 0.0 13.0 13
Orientation:Back
Wall height:7.6'
Depth below grade:6.6'
Insulation depth:7.6'
2x 6030 Sliding Windows:Vinyl Frame:Double Pane with Low-E 36 0.320 12
SHGC:0.26
Orientation:Back
Foundation Wall:Solid Concrete or Masonry 274 0.0 13.0 . 14
Orientation:Left Side
Wall height:7.6'
Depth below grade:6.6'
Insulation depth:7.6'
Foundation Wall:Solid Concrete or Masonry 380 0.0 13.0 20
Orientation:Right Side
Wall height:7.6'
Depth below grade:6.6'
Insulation depth:7.6'
1x Std Basement Window:Wood Frame:Double Pane with Low-E 2 0.310 1
SHGC:0.28
Orientation:Right Side
1st Floor Walls:Wood Frame, 16"o.c. 510 19.0 0.0 26
Orientation:Front
Mud#20:Solid 19 0.170 3
Orientation:Front
Foyer#1:Solid 21 0.170 4
Orientation:Front
1x Breakfast(C):Vinyl Frame:Double Pane with Low-E 11 0.310 3
SHGC:0.28
Orientation:Front
I Breakfast(0):Vinyl Frame:Double Pane with Low-E 18 0.310 6
Project Title:TH138 Wakely Report date: 06/08/11
Data filename: F:\SHARE\Design\Res-Check\Hiland Crossings\56 Meldon Circle.rck Page 1 of 6
SHGC:0.28
Orientation:Front
1st Floor Walls:Wood Frame,16"o.c. 393 19.0 0.0 16
Orientation:Back
1x Master Bed(L):Vinyl Frame:Double Pane with Low-E 33 0.310 10
SHGC:0.28
Orientation:.Back
2x Master Bed(B):Vinyl Frame:Double.Pane with Low-E 19 0.310 6
SHGC:0.28
Orientation:Back
1x Living(P):Vinyl Frame:Double Pane with Low-E 13 0.310 4
SHGC:0.28
Orientation:Back
1x Living(D):Vinyl Frame:Double Pane with Low-E 5 0.310 2
SHGC:0.28
Orientation:Back
I Living(M):Vinyl Frame:Double Pane with Low-E 36 0.310 11
SHGC:0.28
Orientation:Back
Living#19:Glass 19 0.290 6
SHGC:0.20
Orientation:Back
1st Floor Walls:Wood Frame, 16"o.c. 360 11.0 0.0 32
Orientation:Left Side
1st Floor Walls:Wood Frame, 16"o.c. 380 19.0 0.0 19
Orientation:Right Side
2x Living(E):Vinyl Frame:Double Pane with Low-E 29 0.310 9
SHGC:0.28
Orientation:Right Side
1x Dining(H):Vinyl Frame:Double Pane with Low-E 33 0.310 10
SHGC:0.28
Orientation:Right Side
2nd Floor Walls:Wood Frame,16"o.c. 288 19.0 0.0 15
Orientation:Front
1x Bed#2(G):Vinyl Frame:Double Pane with Low-E 32 0.310 10
SHGC:0.28
Orientation:Front
2nd Floor Walls:Wood Frame, 16"o.c. 41 19.0 0.0 2
Orientation:Back.
2nd Floor Walls:Wood Frame,16"o.c. 271 19.0 0.0 16
Orientation:Left Side
2nd Floor Walls:Wood Frame,16"o.c. 370 19.0 0.0 22
Orientation:Right Side
1x Loft Bath(AA):Vinyl Frame:Double Pane with Low-E 5 0.310 2
SHGC:0.28
Orientation:Right Side
Ceiling:Raised or Energy Truss 1469 38.0 0.0 36
2x Skylights @ Living(1306):Wood Frame:Double Pane with Low-E 14 0.450 6
SHGC:0.26
Furnace:Forced Hot Air 92 AFUE.
Air Conditioner:Electric Central Air 13 SEER
Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation
Constriction Code requirements in REScheck Version 4.4.1 and to comply with t requirements listed in the REScheck Inspection
Checklist. r
F�JNEIVNameLos-A-i
-Title Sign re � '� 0� Date
ODO
.�
0683��
p;�oSSl(��P .;
Project Title:TH138 Wakely Report date: 06/08/11
Data filename:F:\SHARE\Design\Res-Check\Hiland Crossings\56 Meldon Circle.rck Page 2 of 6
REScheck Software Version 4.4.1
Inspection Checklist
CNJ(
Ceilings:
❑ Ceiling:Raised or Energy Truss,R-38.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above-Grade Walls:
❑ 1st Floor Walls:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
❑ 1st Floor Walls:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
❑ 1st Floor Walls:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ 1st Floor Walls:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
❑ 2nd Floor Walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
❑ 2nd Floor Walls:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
❑ 2nd Floor Walls:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
❑ 2nd Floor Walls:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
❑ Foundation Wall:Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul,R-13.0 continuous insulation
Comments:
❑ Foundation Wall:Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul,R-13.0 continuous insulation
Comments:
❑ Foundation Wall:Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul,R-13.0 continuous insulation
Comments:
❑ Foundation Wall:Solid Concrete or Masonry;7.6'ht/6.6'bg/7.6'insul,R-13.0 continuous insulation
Comments:
Windows:
❑ 2x 6030 Sliding Windows:Vinyl Frame:Double Pane with Low-E,U-factor:0.320
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Std Basement Window:Wood Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Breakfast(C):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
Project Title:TH138 Wakely Report date: 06/08/11
Data filename:F:\SHARE\Design\Res-Check\Hiland Crossings\56 Meldon Circle.rck Page 3 of 6
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Breakfast(0):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled 0-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Master Bed(L):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe.features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 2x Master Bed(B):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Living(P):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Living(D):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ I Living(M):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 2x Living(E):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Dining(H):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Bed#2(G):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 1x Loft Bath(AA):Vinyl Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Note:Up to 15 sq.ft.of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements.
Skylights;
❑ 2x Skylights @ Living(D06):Wood Frame:Double Pane with Low-E,U-factor:0.450
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Mud#20:Solid,U-factor:0.170
Project Title:TH138 Wakely Report date: 06/08/11
Data filename: F:\SHARE\Design\Res-Check\Hiland Crossings\56 Meldon Circle.rck Page 4 of 6
Comments:
This door is exempt from the U-factor requirement.
❑ Foyer#1:Solid,U-factor:0.170
Comments:
❑ Living#19:Glass,U-factor:0.290
Comments:
Heating and Cooling Equipment:
❑ Furnace:'Forced Hot Air:92 AFUE or higher
Make and Model Number:
❑ Air Conditioner:Electric Central Air: 13 SEER or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are either 1)Type IC rated with enclosures sealed/gasketed against leaks to the ceiling,or 2)Type IC rated and ASTM
E283 labeled,or 3)installed inside an air-tight assembly with a 0.5"clearance from combustible materials and a 3"clearance from
insulation.
Vapor Retarder:
❑ Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors;or it has been determined that
moisture or its freezing will not damage the materials;or other approved means to avoid condensation are provided.
Comments:
Materials Identification and Installation:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Insulation is installed in substantial contact with the surface being insulated and in a manner that achieves the rated R-value.
❑ Materials and equipment are identified so that compliance can be,determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
Duct Insulation:
❑ All ducts not completely inside the building envelope are insulated to at least R-6.
Duct Construction:
❑ Air handlers,filter boxes,and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and
mechanically fastened.
❑ All joints,seams,and connections are made substantially airtight with tapes,gasketing,mastics(adhesives)or other approved closure
systems.Tapes and mastics are rated UL 181A or UL 181 B.
❑ Building framing cavities are not used as supply ducts.
❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
❑ Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International
Mechanical Code.
Temperature Controls:
❑ Thermostats exist for each.separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Heating and Cooling Equipment Sizing:
❑ Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code.
Circulating Service Hot Water Systems:
❑ Circulating service hot water pipes are insulated to R-2.
❑ Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the
system is not in use.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2.
Certificate:
Project Title: TH138 Wakely Report date: 06/08/11
Data filename:F:\SHARE\Design\Res-Check\Hiland Crossings\56 Meldon Circle.rck Page 5 of 6
2010 New, York Energy
Conservation
Construction Code
Certificate
Insulation Rating R-Value
Ceiling/Roof 38.00
Wall 19.00
Floor/Foundation 13.00
Ductwork(unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.32 0.26
Skylight 0.45 . 0.26
Door 0.17 0.20
CoolingHeating&
Forced Hot Air Furnace 92 AFUE
Electric Central Air Conditioner 13 SEER
Water Heater:
Name: Date:
Comments: