Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2010-241
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE (.3%.1rc OCCUPANCY Permit Number. P20100241 Date Issued: Friday, May 21, 2010 This is to certify that work requested to be done as shown by Permit Number P20100241 has been completed. Location: 1002 STATE ROUTE 9 Tax Map Number. 523400-296-013-0001-065-000-0000 Owner. STEWARTS SHOPS CORP. Applicant: GLENS FALLS NATIONAL BANK This structure maybe occupied as a: Certificate of Occupancy (COM) By Omer of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY (Qt 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20100241 Application Number. A20100241 Tax Map No: 523400-296-013-0001-065-000-0000 Permission is hereby granted to: GLENS FALLS NATIONAL BANK For property located at: 1002 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tine of Construction Value Owner Address: STEWARTS SHOPS CORP. Certificate of Occupancy(COM) P.O. BOX 435 SARATOGA SPRINGS,NY 12866-( Total Value Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2010-241 Glens Falls National Bank $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,May 20,2011 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Thursday,May 20,2010 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement NILLIOP CONSTRUCT'ON RX:518-798-8338 Ray 18 2810 1011 P001!0 ._„ • • , Comnuinity Development Office v Town of Ifetu Ibrcr - 742 Bay Road ur:e�icbury, Neuf York •72c7(4 • A)..0 0 Marilyn L<i ha, Luct4hve L)irectur•i)tn'u/Nnt:n, _)irector of BrriittrnW[Ct?de • Creri,,Brc+rorr,Zoning Aiirnirtr*trop?r-1vlicitrre!(. Palmer,Fire Martha! _ ' " NEW BUSINESS CERTIFICATE OF OCCUPANCY PERMIT APPLICATION 0 241( (See- TAX MAP# i • I3 / u BLDG. PERMIT FILE# ° 209--6/`J ffapplicable Name of Business: 61/e ivs r //-5 A/a71 o r)a•/ }C M k Address /} C� of Business: /0 e Si-ate ,\o i-,,f'c / QUESTIONS? CALL 761-1266 OR EMAIL codes(a)queensburv.net /I 1 J/t, l /� f/ VISIT OUR WEBSITE FOR MORE Person in Charge or Manager: �'J /-j J INFORMATION 1Twww.qusonsbury.net Business Phone Number lS) / 93 - 4l f Type of Business: ,60/4k Owner of Property: 5yievia rats Phone Number(s):( i?,f 38/—4,26/ FI8 nC .M' Owners Address: Po 60i 7..35- ara t-i6a ,Spr;n651 NSI / ,'fir �i Please provide an accurate layout of your store showing nail wails, exits, stockrooms, rest rooms, counters and fixture layout on a separate sheet of paper Z11 Signature: ? Date: 6-774C74° Qf person submiYing Lyis tam Notes/ Comments: TOWN 0 i" 7UE@r:4NSI< S.✓' c:; ".Nota:This application is for occupancy only, with no work requiring a-oeilorinsrpi7f .'1U �,� -rift Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection reque ed: Queensbury Building& Code Enforcement Arrive: _Z du}rj- ts' /Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: r NAME: C-,LE 65 k=011_5 tJP►\1©t L cz1e.,PERMIT#: i —Z 1 LOCATION: _hTE11:31 V,th DATE: 5 — ♦ -- i \D ( COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in. w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System _ Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Y2 doors .-. > 10%> 1000 sq.ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame ■■■ Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required ■■■ Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage �6 g � J � Public Toilet Room Handicapped Accessible V Handicapped Service Counters, 34 in.,Checkout 36" y, Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] 1-Fe ik J LJ \ Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Side • '' 'veable Surface 20'wide ©� To Okay To Issue Temp or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Inspection for Permit to Occupy Fire Marshal's Office Request Recd Permit No.( O/44- 2.rl/ Town of Queensbury 742 Bay Road Queensbury,NY 12804 Scheduled Inspection Date: `� 120/10 . S ,ice _ 1 Phone: (518)761-8206 Business Na e:�} N� Time: t1r7 / c.' Fax (518)745-4437 Location: Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Sign-normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hung Inspection of extinguisher FIRE ALARM SYSTEM t �u Fan Shutdown Fire Sprinkler System (FDC) Fire Suppression-kitchen Fire Suppression-Gas Isian i Generator 3 Hood Installation Elevator k Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Elochical r Electric vexing Enclosed/Labeled Combustible Waste Vehicle Impact Protection Knox Box F.D.Signage-Utility Rooms No Smoking Signs Maximum Occupancy Sgn Emergency l,ecvolieRTA ... Approved (If no other approvals apply,,the B&C Office wi issue the Certificat- .f Occupancy) o Denied / call for Recheck Inspect By: 44; lig L:\FireManfie\FM Forms Masters\permilto occupyfonn.doc Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No./®`---.p71/1 T742 Bay own of Queensbury �j�J �J l�') (�/J� Y� Queensbury.NY i 2804 Scheduled Inspection Dote: 6//(/r�®/7i' Time: L' ''�� -" Phone: (518)761-8206 Business Name: A 5' G /l41/77,0-4/ t 7 Fax: (518)745-4437 Location: V---.ci# ? Type of Inspection N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Sign-normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hung Inspection of extinguisher ` FIRE ALARM SYSTEM X JtUii a �m M-"i'l Fan Shutdown f 'i Fire Sprinkler System (FDC) //yLLQ/l " l ��i-v!_" �////__- Fre Suppression-kitchen (� / / Fire Suppression-Gas Islan Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed/Labeled k" Combustible Waste Vehicle Impact Protection Knox Box F.D.Signage-Utility Rooms No Smoking Signs 4041- Maximum Occupancy Sin Simaer"lelt Emergency Evacuation Plan ❑ pproved (If no other approvals apply,the B 8,C Office will issue the Certificate of Occupancy) Denied /call for Recheck Inspec - • By: re i L'\FreMarshal\FM Forms Masters\permitto oc cupyform.doc Commercial Final Inspection Report Office No.: (518) 761-8256 Date Ins.ection r- .- ec ' ed: Queensbury Building&Code Enforcement Arrive: • '. VW. Depart: 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: C - _ D._A 1 t :1 L Qfl 1�-) PERMI ' #: * 2.3--1 LOCATION: 4 AIRCEIL—kC) COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Completeirk7 Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.-38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in. w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 11/2 doors > 10%> 1000 sq. ft. %Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" >� Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler _ Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O r 1 `Q Y\.K.6%€ Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.do