Loading...
RC-000235-2015 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: RC-000235-2015 Date Issued: Wednesday, November 4, 2015 This is to certify that work requested to be done as shown by Permit Number RC-000235-2015 has been completed. Tax Map Number: 308.18-1-45.12 2�\y Location: 41 REVERE RD Owner: Dave Monsour Applicant: Dave Monsour This structure may be occupied as a: SFD 2584 s.f.,3-car attached garage By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director o Building&Code En rcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 qL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000235-2015 Tax Map No: 308.18-1-45.12 �����D Permission is hereby granted to: Dave Monsour For property located at: 41 Revere RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Dave Monsour Single Family-New $230,000.00 Owner Address: 41 Revere RD Total Value $230,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications SFD w/FP 2584 s.f.,3-car attached garage Bedford Close,Lot 58,Section 2 PERMIT FEE PAID-TWS PERMIT EXPIRES: Monday,May 16,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ueens�' 5 SIGNED BY: / r the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150179 Application Number: A20150179 Tax Map No: 523400-308-018-0001-045-012-0000 Permission is hereby granted to: MONSOUR ENTERPRISES LLC For property located at: in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DAVID MONSOUR 53 PINEWOOD Rd Fireplace QUEENSBURY,NY 12804-0000 -3 Cars Attached Single Sin ingle le Family $230,000.00 Total Value $230,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications BP 2015-179 Lot 58, House No. 41 Revere Road Bedford Close, Section 2 Single-Family Dwelling 2,584 sq. ft. with 3 car attached garage 921 sq. ft. $654.95 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, May 22, 2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the xpiration� dat:.) Dated at the To n of u e s 1 �•;, ry V � y, May 22,2015 \ SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement I 'PRINCIPAL STRUCTURE APPLICATION Office Use Only DATE 3671/fc Received Tax Map ID TAX MAP ID �•,, 15 -I- 4? 1 ! PermitINo. 026/ 77 Pecfflit ZONING 44` I MAY 1 8 21 Site Pla # izi3date- HISTORIC SITE Yes No TOWN F QUEESubdivisio # �a t, BUIL!"ING_ _& Cry SUBDIVISION NAME /%14t AJ C IcY Lot# ' rr 5 c� TOWN BD.RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DVA/ELGS,DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/ORU {y`MMUFACTURED & MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. APPLICANT Vli ai Oii )'/1-411/ .e 2,C'S L L( OWNER ADDRESS 6:1) Pi it‘ iix`X:d.JL(f ADDRESS PHONE/E-MAIL 1--) --/ '� /f�i�' (s'!.IG(e - f)�M PHONE/E-MAIL CONTRACTOR ti(-7I Nl it - COST OF CONSTRUCTION(ESTIMATED): $ j1 3C) "? ADDRESS: BUILDING ADDRESS: 1-/ v'c I ('vhy PHONE/E-MAIL CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 1)10 A10 i tSuv PHONE 4/6►.-17/3 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below New Addition Alters ion 1st floor sq.ft. 2nd floor sq.ft. Total sq.ft. Height Single Family 58 Two-Family Multi-Family (#of units ) Townhouse Business Office Retail - Mercantile Factory- Industrial Attached Garage 3 / (# of ) — 9 1 -r Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business Proposed use of building or addition I-4u.Ak_ Source of heat (circle one) rea-S) Oil Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys _ Are there structures not shown on plot plan? Are there easements on the property? �'c� Site Information a. Dimensions or acreage of lot f 5-C acx: b. Is this a corner lot? �(1 c. Will the grade be changed as a result of construction Yes X No d. Public water or Private well ?t,,b`.r_ e. Sewer or Private Septic System `), L. Value of all work to be performed (labor or materials) $ 3v,aX DECLARATION: 1 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/ description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: i- !'dtiir(( 4o(1.7\c- k.V DATE 3/0)t SIGNATURE: DATE ?--/-1`))I FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 SEPTIC DISPOSAL PERMIT Office Use Only DATE _i_Va"2 1 t 6 Received Tax Map ID TAX MAP ID �(,t_. I --t5 -1"15, 1 a Permit No. Permit Fee LOCATION OF INSTALLATION L/ I ilei?-td/P_ d (co t%e rl.t.A.-,9. Approvals: APPLICANT �(4,3O Uy FA L(a pii S 5 LL _ PHONE/E-MAIL %'bl 17/3 je16040 50c.,-ctom ADDRESS 53 kb:A i;kr1 yc( if)1/1 LfiZ_b_ ri l7' ia20V INSTALLER/BUILDER: JCL/VI e, PHONE/E-MAIL ADDRESS: OWNER L7 CI me_ PHONE/E-MAIL Address Ala/I' (J' 7 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: I J G(7►(!J ! Le PHONE 111.4-I !l3 RESIDENCE INFORMATION Year Built #of bedrooms X Gallons per bedroom =Total Daily Flow 1980 or older Garbage grinder installed Y N 1981-1991 Spa or Hot Tub installed ,*.Y _N 1992 Present 1 f ID ',it/0 PARCEL INFORMATION Topography X Flat rolling Steep slope %slope Soil Nature ' ( Sand Loam Clay Other GroundwaterAt what depth? iti') r3 vVLA,kc( (. ,tLk -, d i�t.� i 0 ' tley/ Bedrock/Impervious Material At what depth? vl i/1 P Domestic Water Supply yi Municipal Well(if well,water supply from any septic system absorption is ft.) Percolation Test Rate: P 1,A per minute per inch(test to be completed by licensed engineering/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank Size /a tso gallons(minimum size 1,000 gallons,add 250 gallons to size for each garbage grinder or spa or hot tub) System TypeAbsorption field with#2 stone Total length ,''L-tL ft.;Each trench le '` x (-77- Seepage Pit with#3 stone How many: ;size Alternative System Bed or other type? Holding Tank System Total required capacity? Tank size _ #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. DECLARATION: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance know by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Print Name: 36(g_.t7v15f-LV Date: %,� l LI- Signature: Oa ilk 174l. Date: 1)n It' 6 Town of Queensbury Building&Codes Principal Structure Application July 2014 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury, NY 12804 Home: (518) 745-0929 Phone: (518) 761-8211 Fax: (518)745-4466 David Duell Deputy Highway Superintendent Home: (518) 745-0938 DRIVEWAY PERMIT Date: ,34-)/i5" Applicant Name: NV-DA, c_-usc LL Telephone No.: Nhl-IV 13 Address to Be Inspected: q I (Low_ .1d (%y ltY ldeot# Return Address: 53 Ane u J Cvhy IIY lAP5/ Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( )36" Preliminary inspection completed by: Date: Approval by Highway Supt.: (or) Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent 7 Town of Queensbury Building&Codes Principal Structure Application July 2014 • • Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: 3/a-711 S Tax Map ID Permit No. TAX MAP ID: .IS-t- K,5-1a Permit Fee ZONE: OWNER fibiL E I h( `L l-CN , PHONE/E-MAIL Y:1.i Y '161-1773 l ,'ui CLC ti 1-Cco ADDRESS 53 pi t Xd 6x&ey.XV AL( I a 30'4 _ INSTALLER/ PHONE/E-MAIL 4461-01 /1101120ta Ertirapli 5 eS,LLL BUILDER auk ,c�oC: corn CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: f a IMolft?l GY PHONE/E-MAIL 'I kJ-171 5/Clo e_ roc,-E.co vvl BUILDING ADDRESS Li/ th'o&e AI &Licht bu 'V ROOM OF INSTALL: 6yp64- PLANNED INSTALL DATE: �(a.rl �(�I FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& J STOVE J FINAL INSPECTION ARE if FIREPLACE INSERT REQUIRED. NOTE: j FIREPLACE,FACTORY BUILT* MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: 4�, 10 ; Model#: Listed by: .*Lvocio, yv +4,-h3e. Number: 5e50- gd�ti - ie i/15-fi-Jtocl b , cares c, F,y,alliri Ahiri G4AtimpIiii4ki/1Lr CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: _ ;Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: d ✓'l.n 4.so LAX DATE: 3/2 7J/.5- SIGNATURE: SIGNATURE: (1 ;_b DATE: 3/a7/in" Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 Rough Plumbing 1 Insulation Inspection Report � -fes Inspection request received I1 ,-2,egcj Name (V n ,Q U V Inspected on ( 2 S Location iN Arrive am I pm Permit No. 12-p cj_ n-k-. Inspector's Initials Type of Structure COMMENTS Y N NA Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent /Vents in Place 1 Y, inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I.or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation /Residential Check / Commercial Check —v� Window Sealing �\ T Tyvek or Similar Exterior Sealant l Proper Vent,Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 41/ tido I� Town of Queensbury Building &Code Enforcement Ct Office No. (518)761-8256 NJ Septic Inspection Report Inspection request received: 6111112"c' Name: M Inspected on: a Location: 14li Uez Arrive: a.m./p.m. Permit No.: Inspector's Initials: Comments and/or diagram Soil Type San Clay Type of WMfrAZgaLbiI4WWeII Water Waterline separation distance ft. Well separation distance Other wells: Well Casing Length 50'+/- _Y_N_NIA [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone 2 Seepage Pits: Number Size: Stone Size: Piping Size Type Building to tank Tank to Distribution Box ` got Distribution Box to Field I Pit ` Opening Sealed: Y N End Cap N Inlet/Outlet Pipes&Baffles _N Manholes 12"or less below grade _Y_N [provide extension collar if Yes] _Y_N Location I Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits L Or ft. Conforms as per Plot Plan _ Engineer Report and As-Built _Y ETU Maintenance Contract provided _Y_N Location-ef-S tem on Pro e : root Rear Left Side Right Side Middle Front Middle Rear System Use S%/ Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report MAPN0TE5 1 V L Boundary information shown hereon was compiled from an actual field survey / conducted on March 13,2019 2. North orientation and bear7rtg base permap reference 1. !% Lands Now or Formerly of Imn Rod \ 3. Warren County taxparcel308.18-1-X5.12. Found Joseph A2°fini to \ 4. The location of underground improvements or encroachments,if any exist,oras Book J165 Foga 143 shown hereon,are not certified. There maybe other underground utilities, the existence of which are unknown. Size and location ofall underground utilities must Imn Rod be verified by the appropriate authorities The Underground Facilities Protective Found \ Cganiza don must be notified prior to conducting test borings,excavation and construct n. \ 4'wood Fence 5,3o E ,5�tba,Ci` 5. This survey was prepared without the benef t of an up to date abstract of title. II t 6. Field data capture took place with an accumulated snow cover of 8"to 12" Every Hydrant effort has been made to prepare a complete plotting of the conditions iron 7. Repmducb'on or copying of this documentmay be a violation ofcopyrightlaw d° Froposed F i1I unless permission of the author and/or copynghtholder w obtained. Drivewa �\ 0, \ 5B'5.x2' 2'f 8 % 8. A copy of this document without a proper application of the surveyors embossed I \ :3.5' f �•bf Z '°'�`' -g, , I seal should be assumed to bean unauthorized copy. )' \ Ibrmrletlon 13.3P \ �; f �� � .T9.&EDIFEFERFIVCE Nand Hole' L Conveyance to Monsour Enterprises,LLCby deed dated March 20,2015,filed in the d Warren County Clerks Offr`ce on Apr l X 2015in Baok5139 ofDeeds atpage270 Found \ 7.0' A66' �}.6 I �� Cable/ elT ephone MAPREPERENCFS. Pedestals I Map entitled"Bedford Close Section Two;prepared by Coulter&McCormack,dated july7,1976,filed in the Warren County Clerks Cffrce on Olctober25,lfiMas map number 1750. J i j � ti •� lr°nRod �4'woodFtee ';, Monsour Enterprises LLC BP 2015-179 N �" 4 Found Lot 58 Ho I I use No. 41 Revere Road 1 FfV 1 8 2015 Bedford Close, Section 2 u� 3 Single-Family Dwelling, 3-car att. garage I TOWN p=Q4J;~ vSur' r Lands Now or Formerly of ��� 'Fr��� � i;! Bi)I ;IMG & CODES f S F DATE R6VSONS REOORD/OESMFMON ORAFiER K� Map ofa Proposed PlotPlan \ -A ADD"M DO DOM04W 91 Robert Francomano ' �. rrorImKVrLi'M LdldArbwor = d7af 0 1015 MonsourEntee ses,LLC Book 614 page 689 ' =_ V !' x,3;1 APPROVFI}R74lD 2rVWNOFQUWMURY wAMWCULNswMW _5r mr,�J nxa - - alaP 1.1Wn DW Darrah.Land 5urveying,PUC 15009-2 :'' `° PRo%Mz tst 9764N0jMMomRb4dJ*dley,Now York37W 'M&Y 80LO W S4MPS M TE SURYEYOR•S 093OSSM �� •'�'�P-, �'., r'.,' Phone: ,9 1-w 4m SM9FP 10F1 SEN.NM MW2E TRUE Nro CORE=COM OF THE SUMT S SGftB:t'-!o ( l oracac i KnRxv+o WNW _ AA7H:3/9/75 PROM2 13W L l;3 Rough Plumbing I Insulation Inspection Report Inspection request received E! 1�12wS Name 1\ACdr&zzikAY Inspected on S I Lzt\1-CA5 Location Zk\ ey s • Arrive /a am/pm Permit No Inspector's Initials ri _mit) Type of Structure S� COMMENTS Y N NA Plumbing under slab Rough Plumbing /Nail Plates �` � Plumbing Vent /Vents in Place 1 V2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check `( Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent / Door / Window Sealed (No Insulation) ‘// Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace ,g Duct work sealed properly /No duct tape Bloierer Door Test / (Air Sealing ,/J Town of Queensbury Building & Code Enforcement Office No. (518) 761.8256 411111111111111 Town of Queensbury Fire Marshal � 742 Bay Road � Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/ Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# V ` Schedule Inspection ‘,20 i Time am pm anytime Inspector Name 1'�k.,1,R y, -- Address ', QQ I ''J I Rough In VFinal_ Appliance Manu cturer Model# ( t O .� 1 3 _ `� —5- Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) ‘7. Firestop(s) Vertical Chase V N Wall Penetration Vent Clearances to Combustibles `1/ Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve 7 Combustion Air % Hearth Extension (if any) V Mantel t/ Height above f/p opening Witness Operation Tank Placement(if LP) V CO Detection -1.,q1,5k...3(=-1.74- (/ CSST Bonding White—Building Dept. Venom—Customer Pink—Fire Marshal I Town of Queensbury Building & Code Enforcement 8 - t o Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: 1 2)04_5 Name: 'I`A4Ynti_�5,Q_✓0'.),-t.v Inspected on: e(253,t(2_,akS Location: Al Rv✓? bad Arrive: a.m./p.m. Permit No.: ��—� Inspector's Initials: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs I Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts I Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. R. \--) c'` Z P' Notches I Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour (Di Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off, if required Framing /Firestopping Inspection Report MO4i i -3 Rough Plumbing / Insulation Inspection Report Inspection request received 6\ Name 1\4C3,M4AA.0 Inspected on j 1-4--1 215 Location /, n Arrive 2.% 1c am tfin Permit No. 1 'D- 9 Inspector's Initials ejil\--) Type of Structure COMMENTS Y N NA Plumbing under slab '�. Rough Plumbing /Nail Plates Plumbing Vent / Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape Blower Door Test Air Sealing Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Town of Queensbury Building &Code Enforcement ,.te Office No. (518) 761-8256 �— �C an—.... Framing I Firestopping Inspection Report Inspection request received: ql5f ' S Name: (Y.04 SU(,C( Inspected on: /L�I�' 82 6 „ /,/ Location: 11 1 � y , Rc� Arrive: 41101c���_ a.m.l p.m. Permit No.: gD 15—]/-7 9 / Inspector's Initials: _ TYPE OF STRUCTURE: 5 c( 1' S-cd-,c c2 1>n - Y N NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs I Headers „.)5.4 j Truss Specification Provided � C.) � ,iJ L Bracing/Bridging Joist hangers /4 / Jack Posts/Main Beams Exterior sheeting nailed properly 12”O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses A�� and water ft.or less on center /� ce and water field 24 inches from wall / Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above I below grade 5.0 sf grade Design Professional Sign-off,if required Framing/ Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report ?- /OC(A Office No. (518) 761-8256 Date In ction r uest received: g) , / Queensbury Building & Code Enforcement Arrive. `c am/pm 742 Bay Road, Queensbury, NY 12804 Inspector' In' i s: ____ 04, NAME: AZ61,XcehAir PERMIT #: 1SI] 79 LOCATION: I 'K INSPECT ON: 4e111:0/,S TYPE OF STRUCTURE: ?O — 7 J Y N N/A Plumbing under slab Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain /Vent Air / Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes In a tial Check/ Commercial Check indow Sealing l.4 yv r imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 05 13 "F)Town of Queensbury Building & Code Enforcement \ � Office No. (518) 761-8256 Framing I Firestopping Inspection Report Inspection request received: 8\b12-CAS Name: ManC-QA- ✓ Inspected on: E31, Location: 4( e veArrive: a.m.l p.m. Permit No.: Inspector's Initials: TYPE OF STRUCTURE: 3f ry NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Z k , 1115 Truss Specification Provided 1 Bracing/Bridging Joist hangers V/ Jack Posts/Main Beams V Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour �J Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in.(H) • 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing / Firestopping Inspection Report 6. ? Town of Queensbury Building &Code Enforcement At:), Office No. (518)761-8256 Rough Plumbing / Insulation Inspection Report Inspection request received: 6`be.\ I Name: Tp,�n.5�.✓ Inspected on: �\� L"7-J;21 Location: y1 ?--wkyQ Arrive: d� • �►a.�s Permit No.: 5 - lam. Inspector's Initials: ��O. Type of Structure: SFdA COMMENTS NA I Plumbing under slab ztk2k 11-1.3 Rough Plumbing / Nail Plates / X1,1 `I a'-- c''c Plumbing Vent/Vents in Place / ti�st ov✓s v 1 1/2 inch minimum Drain Size ou,Y -Eo rno,vrcw\1 (11% 15� Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction _ AI P essure Test Dr.'.r Vent i' Head 5 '.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/Insulation Inspection Report 57 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart. m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials/1� NAME: r - PERMIT#: LOCATION: e INSPECT ON: TYPE OF STRUCTURE.-,/ Comments Y N N/A ( �u Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing et areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 I , ' Foundation Inspection Report • Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: _ • m 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials• p • NAME: lqW5D1A.r ' PERMIT#: , LOCATION: ° ' 1 R INSPECT ON: (14 TYPE OF STRUCTURE:'-512i frG Z�/ (34-6 Comments Y N N/A Bi` �� Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing . •• • et areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 Foundation Inspection Report Wj I -� c-lecex Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: ; \ a pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials- 3 NAME: MO YA.SOL,tv PERMIT#: LOCATION: i, Yu¢NQX INSPECT ON: 6 I fl TYPE OF STRUCTURE: Sc II Comments Y N N/A jczff �j , - 2 I-1S Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 REScheck Software Version 4.6.1 Compliance Cer ' 1Z Monsour Enterprises LLC BP 2015-179 Lot 58, House No. 41 Revere Road Bedford Close, Section 2 Project New Single Family Residence Single-Family Dwelling, 3-car att. garage Energy Code: 2010 New York Energy Conservation CJ Location: Warren County, New York MAY 18 2015 FUJI Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 45 deg. from North TOWN OF QUEENSBURY Conditioned Floor Area: 2,596 ft2 BUILDING & CODES Glazing Area 13% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 41 Revere Road David&Lauren Monsour Ethan Peter Hall Queensbury,NY 12804 53 Pinewood Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-461-1713 Saratoga Springs,NY 12866 dave@gocif.com 518-580-1905 ephall@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 0.4%Better Than Code Maximum UA: 470 Your UA: 468 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Assembly Gross Area Cavity Cont. or U-Factor UA Ceiling 1: Raised or Energy Truss 2,596 38.0 0.0 0.025 65 Wall 1: Wood Frame, 16"D.C. 735 21.0 0.0 0.057 34 Orientation: Front Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 93 0.300 28 Orientation: Unspecified Door 1:Solid 38 0.300 11 Orientation: Unspecified Wall 2:Wood Frame, 16" D.C. 665 21.0 0.0 0.057 35 Orientation: Right side Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.300 5 Orientation: Unspecified Door 2:Solid 18 0.300 5 Orientation: Unspecified Door 3:Solid 20 0.300 6 Orientation: Unspecified Wall 3:Wood Frame, 16" D.C. 735 21.0 0.0 0.057 31 Orientation: Back Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 148 0.300 44 Orientation: Unspecified Door 4: Glass 40 0.300 12 Orientation: Unspecified Project Title: New Single Family Residence Report date: 05/18/15 Data filename: Y:\Monsour Residence\Monsour.rck Pagel of 7 Gross Area Cavity Cont. Assembly Pen or R-Value R-Value U-Factor UA meter Wali 4:Wood Frame, 16"o.c. 665 21.0 0.0 0.057 36 Orientation: Left side Window 4:Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.300 11 Orientation: Unspecified Basement Wall 1:Solid Concrete or Masonry 654 15.0 0.0 0.055 36 Orientation: Front Wall height: 8.9' Depth below grade: 7.6' Insulation depth: 8.5' Window 5:Vinyl/Fiberglass Frame:Double Pane with Low-E 6 0.300 2 Orientation: Unspecified Basement Wall 2:Solid Concrete or Masonry 592 15.0 0.0 0.055 32 Orientation: Right side Wall height: 8.9' Depth below grade: 7.6' Insulation depth:8.5' Window 7:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.300 5 Orientation: Unspecified Basement Wall 3:Solid Concrete or Masonry 654 15.0 0.0 0.055 36 Orientation: Back Wall height:8.9' Depth below grade: 7.6' Insulation depth:8.5' Basement Wall 4:Solid Concrete or Masonry 592 15.0 0.0 0.055 32 Orientation: Left side Wall height: 8.9' Depth below grade:7.6' Insulation depth:8.5' Window 6:Vinyl/Fiberglass Frame:Double Pane with Law-E 6 0.300 2 Orientation: Unspecified Compliance Statement: The proposed building design described here Is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6. d to co ly w' the andatory requirements listed in the REScheck Inspection Checklist. � � Ethan Peter Hall-Architect r Name-Title S ID ate w Project Title: New Single Family Residence Report date: 05/18/15 Data filename: Y:\Monsour Residence\Monsour.rck Page 2 of 7 REScheck Software Version 4.6.1 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.lD 103.2 Construction drawings and ❑Complies Requirement will be met. [PR111 documentation sufficiently ❑Does Not ,0 demonstrates energy code ❑Not Observable Location on plans/spec: A- compliance for the building ❑Not Applicable 2 envelope. pP 103.2, Construction drawings and ❑Complies Requirement will be met. 403.7 documentation sufficiently ❑Does Not [PR3]1 demonstrates energy code ❑Not Observable Location on plans/spec:A- 14 compliance for lighting and 2 mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. [PR2]2 sized per ACOA Manual S based Btu/hr Btu/hr ❑Does Not V; on loads per ACCA Manual J or Cooling: Cooling: ❑Not Observable Location on plans/spec:A- other approved methods. Btu/hr_ Btu/hr ❑Not Applicable 2 Additional Comments/Assumptions: 11 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Single Family Residence Report date: 05/18/15 Data filename: Y:\Monsour Residence\Monsour.rck Page 3 of 7 2010 New York Foundation Inspection Complies? Comments/Assumptions Energy 303.2.1 Exposed foundation insulation ❑Complies Exception: Requirement is not applicable. [FOil]2 protection. ❑Does Not J []Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies Exception: Requirement is not applicable. [F012]2 :❑Does Not MV []Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Single Family Residence Report date: 05/18/15 Data filename: Y:\Monsour Residence\Monsour.rck Page 4 of 7 Section Plans Verified Field Verifled # Framing/Rough-In Inspection Re .ID Value Value Complies? Comments/Assumptions & 402.4.4 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not Q AAMA/WDMA/CSA 101p.S.21A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate&It;= 2.0 ❑Not Observable Location on plans/spec: A- dm leakage at 75 Pa. ❑ 2 No[Applicable 403.2.2 All joints and seams of air ducts, ❑Complies Requirement will be met. [FR13]1 air handlers,filter boxes, and ❑Does Not 111 building cavities used as return ❑Not Observable Location on plans/spec:A- ducts are sealed. ❑Not Applicable 2 403.2.3 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not 0 ❑Not Observable Location on plans/spec:A- ❑Not Applicable .2 403.3 HVAC piping conveying fluids R-_ R-_ ❑Complies !Exception: Requirement is (FR17]' above 105 QF or chilled fluids ❑Does Not not applicable. below 55 QF are insulated to R-3. - ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water R-_ R-_ ❑Complies Requirement will be met. [FR18]2 pipes are insulated to R-2. - ❑Does Not +. ❑Not Observable Location on plans/spec:A- ❑Not Applicable 2 403.5 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR191' installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable Location on plans/spec: A- ❑NotApplicable 2 Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Ter 3) Project Title: New Single Family Residence Report date: 05/18/15 Data filename:Y:\Monsour Residence\Monsour.rck Page 5 of 7 2010 New YorkInsulation Inspection Complles? Comments/Assumptions Energy I 303.1 All installed insulation labeled or ❑Complies Requirement will be met. [IN13]2 installed R-values provided. []Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Ter 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact Crier 3) Project Title: New Single Family Residence Report date: 05/18/15 Data filename:Y:\Monsour Residence\Monsour.rck Page 6 of 7 Section Plans Verified Field Verified # Final Inspection Provisions & Re .ID I I Value Value Complies? Comments/Assumptions 402.4.2, Building envelope tightness ACH 50=_ ACH 50 =_ ❑Complies Requirement will be met. 402.4.2.1 verified by blower door test result ❑Does Not [FI17]1 of<7 ACH at 50 Pa.This ❑Not Observable Location on plans/spec:A- Q, requirement may instead be met 2 via visual inspection,in which []Not Applicable case verification may need to occur during Insulation Inspection. - 403.2.2 Duct tightness via post- _cfm _cfm []Complies Exception:All ducts and air [F1411 construction with maximum ❑Does Not handlers are located within 11 leakage of 8 cfm to outdoors, or [-]Not Observable conditioned space. 12 cfm across systems.For rough-In tests,verification may ❑Not Applicable Location on plans/spec:A- need to occur during Framing 2 Inspection,with maximum leakage of 6 cfm across systems and 4 cfin without air handler. 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed on forced air furnaces. ❑Does Not J ❑Not Observable Location on plans/spec:A- ❑Not Applicable 2 403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. u ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies Exception: Requirement is [F[11]1 'systems have automatic or []Does Not not applicable. accessible manual controls. [-]Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [F17]2 ❑Does Not ❑Not Observable _ ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: ------------- 1 JHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Ter 3) Project Title: New Single Family Residence Report date: 05/18/15 Data filename:Y:\Monsour Residence\Monsour.rck Page 7 of 7 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Coaling System: Water Heater: Name: Date: Comments 1. Boundary information shown hereon was compiled from an actual field survey conducted on March 13, 2015. 2. North orientation and bearrngbasepermap reference l. li,onRod^^ \ ----- - 3. Warren 8. Countytaxparo&3018-1-45.12. Found \ Robert Franeomano Book 614 Page 689Aff \ e� 4. The location of undergroundimpmvementsorencroachments ifany exist,oras shown hereon, arenot cerhfied. There maybe other underground utilities, the existence of which are unknown. Size and location ofaE underground utilities must be verified by the appropriate authorities. The Underground Facilities Protecctive Organization must be notified prior to conducting test borings, excavation and construction. 5. This survey was prepared without the benefit of an up to date abstract of title 6. Field data capture took place with an accumulated snow cover of 8" to 12". Every efforthas been made to prepare a complete plotting of the conditions 7. Reproduction or copying of this documentmay he a violation ofcopyrightlaw unless pe=Lwon of the author and/ or coppriotholderis obtained. 8. A copy of this document withouta properappEcation of the surveyor's embossed seal should be assumed to bean unauthorized copy. DEEDREFERENCE: L Conveyance to MonsourEnterprises, LLC by deed dated March 20, 2015 filed in the Warren County Clerks Office on Aprd is 2015m Book 5139 of Deeds atpage270. N 1. Map entitled "Bedford Close Section Two'; prepared by Coulter & McCormack dated July 7 1976, filed in the Warren County Clerks Office on October 25, 1976 as map number 1750. Monsour Enterprises LLC BP 2015-179 Lot 58, House No. 41 Revere Road Bedford Close, Section 2 Single -Family Dwelling, 3 -car att. garage FMAY 182015 '] TOVu . 6 � N \ MAPNOTES \ 1. Boundary information shown hereon was compiled from an actual field survey conducted on March 13,2015.Improvements shown hereon perfield data captured October 1,2015 Lands Now o� Former/ of 2. North orientation and beanngbasepermap reference 1 Iron Rod \ NG Found Joseph Ini to \ sU 1`C 3. Warren County tax parcel308.18--1-45.12.Book 3165 43 L of 4. The location of undergroundimprovements or encroachments,Many exist,oras shown hereon,are not certified. There may be other underground utilities,the kon Rod existence of which are unknown. Size and location ofaR underground utilities must N71 03530'B Found be verified by the appropriate authorities The Underground Facilities Protective 200.00' \ Organization must be notified prior to conducting test borings,excavation and ctconstruction. \ 5. . This survey was prepared without the benefit of an up to date abstract of title. ' \ Hydrant 6. Reproduction or copying of this documentmay be a violation ofcopyrightlaw ' Blacktop \ unless permission of the author and/or copyright holder is obtained. Driveway\ Iron Rod \ A copy of this document without a proper application of the surveyor's embossed Found �Vmyl Stockade Fence 7.3 \ alony1ropertyLine �\ \ y5. �, seal should be assumed to be an unauthorized copy. \ 5.5' X8.5' \ Steel 3.25' Garage \ 2.0' x Fence 12.5' •683 1 g31 Wood O \ Frame 23. \ aResidence� \ \ Wooden\ Paver v DEED REFERENCE Shed \ Patio \ b� m Inground Covered w \ Conc.\ Water and Hole 1. Conveyance to MonsourEnterprises,LLCby deed dated March 20,2015,f led rn the Pool Area ,Cone. Walk o o \ 283 Porcl4 \ \ - shut off Warren County Clerks Office on Apri110,2015m Book 5139 of Deedsatpage 270. Q o_ o \ 4.0 - \a Iron Rod Gas Meter Found N \\ /�C�a �1 0, 975Cable/Te l pone MAPREFERENCES Mee. � Pedesas Usti �� vinyl 1 Map entitled"Bedford Close Section Two prepared by Coulter&McCormack,dated v O O Stockade 0 5�3�� July 7,1976,filed in the Warren County Clerks Office on October 25 1 a Fence75%See,1M-- 513 00, Y tl' P o \/ 200. \ number 1750. 7. tD y kon Rod �4'Wood ce L SUR " EY t O Found N w . QF N 1 r ARS F� / r M p i Lands Now r Former/ of MSTI"M.�3 R"N DATE REVISIONS o/�scR� DR*rM MEW=r e Map of a FLr7al Survey womnf ffSEMM 72CO `�• Robert Francomano aUBMEM s��� imc LandsNoworFom�erlyof O 2016 MonsourEntezprises,LLC Dwn*UW .P" / ✓�' Book 614 Page 689 APPROVED.-FaID TOWNOFQUEF.NSBURY WARRENCOUNTY,NEWYORK p3 !. . $ :o v Darrah Land Surveyin&PLLC 15009-3 `rl�N0 PRoJ.NO.- 150�A7 3764NorthSf+Phoneore .-(518)793-4692 d Hadley,New York11835 'atr BOUMW SURVEY YAPS VM ME SlR2VE10RS Sr�r. IOFI SEAL AFE GDKWE TRUE NW COFO1E�f COPE OF THE SURVEMS - SCALE 1-40 PROJNO.15009 OfaGNAI.NORK Nm WNW DATE:10/29/15