Loading...
2015-090 TOWN OF QUEENSBURY wow742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20150090 Date Issued: Tuesday, September 01, 2015 This is to certify that work requested to be done as shown by Permit Number P20150090 has been completed. Location: 37 Devin Ct Tax Map Number: 523400-296-014-0002-005-000-0000 Owner: CERRONE BUILDERS Applicant: CERRONE BUILDERS This structure may be occupied as a: Fireplace By Order of Town Board Garage - 1 Car Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property ("DJ 4 1St' owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY Fora 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150090 Application Number: A20150090 Tax Map No: 523400-296-014-0001-021-000-0000 Permission is hereby granted to: CERRONE BUILDERS, INC. For property located at: 37 Devin Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: CERRONE BUILDERS, INC. Fireplace51 OAK VALLEY Way Garage- 1 Cr Attached QUEENSBURY,NY 12804-0000 Single FamilyDwelling $350,000.00 Total Value $350,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2015-090 Lot 5, House No. 37 Devin Ct. The Village at Sweet Road SFD w/attached garage 1712 s.f. $410.50 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, April 22,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To n o eens ;A : ,April 22,2015 Aff SIGNED BY 1 \ for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Received DATE l — ! ' 0 u Tax Mapp ID ol(p,> - -S TAX MAP ID 7%, �`T-�-5 1.151.5-1)3C.) Permit N N . APR 16 2015 Pe 11&. e sl 10• -F S7�`� /(� 111 Re Fee d tW ZONING /tit TOWN OF QUEEN`, Site Plan# HISTORIC SITE Yes No BUILDING&CC Subdivision # 5f6 F-Aota. SUBDIVISION NAME S V‘t 1 45F-C9 Lot# 5 TOWN BD.RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWELLINGS,DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED & MODULAR HOMES, BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. APPLICANT C r! l OWNER rls C 1/!/h ADDRESS 12+. 9 ADDRESS f r�C . MAYIA 7,1/ PHONE/E-MAIL4 6-775°/C.g.i-ro iletoU PHONE/E-MAIL C9 g(wail. Lr '- 3 "0, a -st; CONTRACTOR COST OF CONS TRUCTION(ESTIMATED): $ . /i++ ADDRESS: BUILDING ADDRESS: 31 DEJ t C+ • PHONE/E-MAIL G CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: ql-t:VPI\I (1çLP_ON t PHONE I-6331 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below New Addition Alteration 15'floor sq. ft. 2"d floor sq.ft. Total sq.ft. Height Single Family X r2— h I - Two-Family Multi-Family (# of units ) Townhouse Business Office Retail - Mercantile Factory- Industrial Attached Garage (# of I ) r yS"y 40 Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 Fuel Burning Appliance & Chimney Application,--TT Office Use Only LS a �`J `..Received DATE: 4—I S — I SU� tr ap ID TAX MAP ID: 16 2015 No. PR rmit cc Se) ZONE: ENSB\ ]OVN9J&EJRYm — OWNER C E .1I UDE-P-5 �^ PHONE/E-MAIL erroneb:hidovs an ADDRESS I51G1 - C� 7 e---r LpviF1'7 11_ 2 9 111 . cam INSTALLER/ l 1 l- PHONE/E-MAIL • BUILDER 08 m.pPrN CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: PHONE/E-MAIL "'3 ) I— (o33) BUILDING ADDRESS '31 I✓ev CA-- CL.p-r 5) ROOM OF INSTALL: L✓,1I 1 N Cq I2.-15,0 AA PLANNED INSTALL DATE: (Q I FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT X REQUIRED. FIREPLACE,FACTORY BUILT* /� NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: ; Model#: Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE y STEEL �'' Size in inches Material X DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: f V 1 A 1=Sr 'c ;Model #: 3(6.OD V- DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: EL-tt _E til E DATE: 4— 15—1 S SIGNATURE: 'r DATE: Ci—/S—/ S Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 CHECKLIST- SINGLE FAMILY PROJECT Project name: (—err- S I'Fvin) 0-4 . APR 16 2015 REQUIRED - 2 sets of the following documentation TOWN or QUCCNSDURYe No N/A 1. Building permit application completed BUILnWG & COQFc 2. Energy Code inspector's report from REScheck 3. Septic alteration (if applicable) _ 4. Solid Fuel Burning or Gas Appliance form (if applicable) 5. Driveway Permit k 6. Structural Drawings a. Floor plans _ SC b. Foundation plan X c. Cross Sections d. Elevations �( _ e. Window & Door Schedule f. Natural Light, Ventilation and Emergency Egress �( g. Plans signed/sealed by registered architect or engineer 7. Plot plans: indicate proposed structure, showing setback dimension from all surveyed property lines )( a. Show location of all existing structures on property SF b. Show location of water supply (well or water lines) �C c. Show location and configuration of septic disposal system or sewer line 8. Electrical inspection agency selected �( CHECKLIST- MULTIPLE DWELLING/COMMERCIAL Project Name: REQUIRED -2 sets of the following documentation Yes No N/A 1. Building permit application completed 2. Energy Code COMcheck and inspector's report form 3. Septic alteration (if applicable) 4. Solid Fuel Burning or Gas Appliance form (if applicable) 5. Driveway Permit 6. Structural Drawings a) Floor plans b) Foundation plan c) Cross Sections d) Elevations e) Design loads including floor, snow load and wind load f) Seismic design g) Plans sii_ ned and sealed by registered architect or engineer h) Window& Door Schedule 7. Plot plan—indicate proposed structure, showing setback dimension from all surveyed property lines a) Show location of all existing structures on property b) Show location of water supply (well or water lines) c) Show location and configuration of septic disposal system or sewer line 8. Electrical inspection agency selected 4 Town of Queensbury Building&Codes Principal Structure Application July 2014 Town of Queensbury ..L-; w L Thomas R. Van Ness Highway Department D - l Highway Superintendent 742 Bay Road, Queensbury, NY 1 APR 16 2015 Home: (518) 745-0929 Phone: (518) 761-8211 Fax: (518)745-4466 TOWN OF QUEENSBURY David Duell BUILDING& COn7c Deputy Highway Superintendent Home: (518) 745-0938 DRIVEWAY PERMIT Date: —IS - 1 S Applicant Name: ,677-2ciu BUU.De723 Telephone No.: 36,1- (o 33i Address to Be Inspected: for 5 -Pe-viA)- Ct. ( 37 D��1' C4.) Return Address: /5$9 /. 9 1'an-�' �p (2-432-i) Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: (or) Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent 7 Town of Queensbury Building&Codes Principal Structure Application July 2014 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: 812 t 115 NAME: CeArvtaWL.,-buis LOCATION: C 3' bsz C PERMIT #: 20 S—O� Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: CA/ Craig Brown, Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc 296.-14-2-5 PERMIT PLOT PLAN C26/ I HAVE PERSONALLY MEASURED THE DISTANCE FROM THE PROPERTY LINES TO THE PROPOSED STRUCTURE(S)OR SIGNS) Sic dGlc ji4ois SIGNATURE i E I2 1 -70e^.3`1 . --coer A So.o +1-EXA S E 1'l////// 25 A a� 0 l.LA g a.o• 4-25o� APPRok. Ri'PRAk. 3o'n1I;J w g0 . 00• f i1 --„ E 1 APR 16 2015 TOWN OF QUEENSBURY BUILDING& CODES Rough Plumbing / Insulation Inspection Report t-10 c`'" Office No. (518) 761-8256 Date Ins i ectio r•quest received: 7,1191 X15 Queensbury Building & Code Enforcement Arrive: _P am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's ni . s,- NAME: (fJ/DL PERMIT#: 1 'QV , LOCATION: � Jih -! INSPECT ON: mon. (7I ) 015 TYPE OF TRUCTURE:L0-1-5 � � 0, S-vy Y N N/A12.iva/ Plumbing under slab n Rough Plumbing / Nail Plates (s:p)3 -7T-gVt Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air / Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insu sidential Check/ Commercial Check -Window Sealing 4'1-k 11/ yvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing_Insulation Inspection_02 05 13 Town of Queensbury Building&Code Enforcement Office No. (518)761-8256 Rough Plumbing I Insulation Inspection Report Inspection request received: Name: C v(-0 ) Inspected on: b 1 1 2-1 2031 Location: } 'Q, ✓Z C Arrive: /(r' 5T a.m. l p.m. Permit No.: Inspector's Initials: Type of Structure: COMMENTS Y N NA Plumbing under slab --1Q 33 I Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing ‘,3-6,A,)6 Rough Plumbing/Insulation Inspection Report Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 6-iO Framing / Firestopping Inspection Report Inspection request received: 6 \ 8 l 5 Name: c X _, Inspected on: `moi l-2-U Location: 51- VPIA n Arrive: -Za a.m./p.m. Permit No.: — 0 Inspector's Initials: TYPE OF STRUCTURE: Sc N NIA COMMENTS: ir Framing C Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided t Bracing/Bridging Joist hangers ✓/ Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour )0, Firestopping G� Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/ Firestopping Inspection Report �► ' rLes - V'6-t Y L\ 04v-I t\ 1 Town of Queensbury Fire Marshal I F i-_ 0 742 Bay Road � Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/ Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. cl ^� Permit# 15- i� Schedule Inspection r( t`' Time // am m anytime Inspector Name ( y✓ IN.—) Address 5'1- bC..Ni 1 V1 Ct• Rough Final_ Appliance Manufacturer Model# PR 7 Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated 111 ��r Yes No N/A Comments Floor ProtectionV / Clearances to Combustibles (all sides) tz Firestop(s) Vertical Chase Wall Penetration / Vent Clearances to Combustibles / Vent/Chimney Termination tt(/// Chimney height must be 3 feet above roof e / penetration;2 feet above any combustible (/ construction within 10 feet Gas Shut-Off Valve Combustion Air (// Hearth Extension (if any) 1! Mantel / ...4P g Height above f/p opening `l(/Il. li Witness Operation Tank Placement(if LP) 7 a_/ taX7 eaq,C, CO Detection CSST Bonding White—Building Dept. Yello i—Customer Pink—Fire Marshal Town of Queensbury Building&Code Enforcement Office No. (518)761-8256 Rough Plumbing I Insulation Inspection Report Inspection request received: Name: Inspected on: (0 9---CAarff Location: " '-J"w\Cr Arrive: _ '41E4 a.m. / p.m. Permit No.: 1`5--01,0 Inspector's Initials: • �`Ali G Type of Structure: 5 .-k\--) COMMENTS Y N NA Plumbing under slab ‘C:11,,Nvy 1. t5t3 .( Rough Plumbing / Nail Plates k/Z Plumbing Vent/Vents in Place ✓ 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping itr/ Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/ Insulation Inspection Report Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 )Q—12— Framing / Firestopping Inspection Report Inspection request2received: Jl, (?..,1/(0.)".9.3 ^r15 1 Name: / Inspected on: glut 1 Location: 5.' bcy'r C* - Arrive: /moi• a.m./p.m. Permit No.: t'5 '-000 Inspector's Initials: �I i TYPE OF STRUCTURE: scc S� Y N N/A COMMENTS: Framing Attic Access 22"x 30"minimum 1 �, Jack Studs/Headers `:\-Q' . x' ''l - Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w)16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center 1r Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/ Firestopping Inspection Report ��4 2�4 Foundation Inspection Report Date Inspection request received:Office No. (518) 761 8256 p q 115) Queensbury Building&Code Enforcement Arrive: am/pm Depart: 2\ m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: ' PERMIT#: t LOCATION: e v i,J CT. INSPECT ON: 7 L 14 t2-0%5 TYPE OF STRUCTURE: Comments Y N N/A �-k - Jb H X33 Footings Piers Monolithic Slab Reinforcement in Place — � � The contractor is responsible for K;�►.•�. j providing protection from freezing for 48 hours following the placement SkftasS of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump ati ! Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 V ' TuES, Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 5\ 5' 15 Queensbury Building&Code Enforcement Arrive: am/pm Depart:3745n 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials NAME: CC)/ PERMIT#: \ —O T LOCATION: � " • t Ct` INSPECT ON: 5\, TYPE OF STRUCTURE: 5 Comments N N/A VAf ,50 - 2 I' rFootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014