2015-131 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20150131 Date Issued: Monday, July 20, 2015
This is to certify that work requested to be done as shown by Permit Number P20150131
has been completed.
Tax Map Number: 523400-289-014-0001-016-000-0000
Location: 17 PIONEER Pt
Owner: JANE NOLAN BARTON & OTHERS
Applicant: JANE NOLAN BARTON & OTHERS
This structure may be occupied as a:
Septic Alteration Residential
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
1011%
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20150131 Application Number: A20150131
Tax Map No: 523400-289-014-0001-016-000-0000
Permission is hereby granted to: JANE NOLAN BARTON & OTHERS
For property located at: 17 PIONEER Pt
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JANE NOLAN BARTON & OTHERS Septic Alteration Residential
445 RIDGE Rd Total Value
QUEENSBURY,NY 12804
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2015-131
septic alteration
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, May 01,2016
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of ee ury; ida vivo' 01, 2015
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
SEPTIC DISPOSAL PERMIT
L-4 Office Use Only
C
DATE .. $ 'Ceived
nn ID
TAX MAP ID 280. 6 E MAY 0 1 2015 P rM No. 2.015 -1'71
_ Permit:Fee LtD VA
LOCATION OF INSTALLATION 17&19 P1 S NEER POINT"' QUEENSBURApproliais:
(GLEN LAKE) - a & CODES
APPLICANT TERRY&JANE BARTON / COLLEEN HOGAN CLARK PHONE/E-MAIL JANE.BARTON50@YAHOO.COM-
ADDRESS 445 RIDGE ROAD,QUEENSBURY NY 12804 / 3305 HIDDEN RIVER VIEW ROAD,ANNAPOLIS MD 21403
INSTALLER/BUILDER: (TO BE DETERMINED) PHONE/E-MAIL (410)693-3341(COLLEEN) 4
ADDRESS:
OWNER (SAME AS APPLICANT) PHONE/E-MAIL
Address
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: HUTCHINS ENGINEERING PHONE (518)745-0307
RESIDENCE INFORMATION
Year Built #of bedrooms X Gallons per bedroom =Total Daily Flow
1980 or older Garbage grinder installed Y ✓ N
1981-1991 Spa or Hot Tub installed _Y ✓ N
1992-Present 5 110 550
PARCEL INFORMATION
Topography ✓ Flat rolling Steep slope %slope
Soil Nature ✓ Sand Loam Clay Other
Groundwater At what depth? >7'
Bedrock/Impervious Material At what depth? >7'
Domestic Water Supply GLEN LAKE Municipal Well (if well,water supply from any septic system absorption is ft.)
Percolation Test Rate: 1-5 per minute per inch(test to be completed by licensed engineering I architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION
Tank Size 1,500 gallons(minimum size 1,000 gallons,add 250 gallons to size for each garbage grinder or spa or hot tub)
System Type Absorption field with#2 stone Total length ft.;Each trench x
Seepage Pit with#3 stone How many: ;size
Alternative System Bed or other type? PRESBY SYSTEM ABSORPTION BED
Holding Tank System Total required capacity? Tank size #of tanks
Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2) We will no longer
allow systems to be covered until such time as an As-Built plan is received & approved. The installed system must match the septic system
layout on file—no exceptions.
DECLARATION: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or
failure to make a material fact or circumstance know by or on behalf of an applicant, shall be void. I have read the regulations
and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
Print Name: a(lee, Necnn C io -Ic
Signature: Date: `1 - 2 /S
Town of Queensbury Building&Codes ✓ �_ Septic Disposal Permit July 2014
QQSVC- t 6-1U-e UNC
I-
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256
Septic Inspection Report
Inspection request received:
Name: 02\,a5I -1 &L,44,(-4 . Inspected on: I ( [�5
Location: 1,9 o/JC Arrive: / cc a.m.lp.m.
Permit No.: /P t4C \, ( Inspector's Initials:
Comments and/or diagram
Soil Type: Sand/Loam/Clay
Type of Water: Municipal/Well Water
Waterline separation distance ft.
Well separation distance ft.
Other wells:
Well Casing Length 50'+ - Y N N/A
[150'to well required if NO]
Absorption Field: Total lengt ft.
Length of each trench ft.
Depth of trenches ft.
Size of Stone U(/
Seepage Pits: Number
Size: x /
Stone Size: fiil\j/(9et ‘tr-L
4X7
Piping ize Type . 4- �,."�-(
Building to tank %
Tank to Distribution Box
Distribution Box to Field/Pit
Opening Sealed: _Y N
End Cap _Y_N
Inlet/Outlet Pipes&Baffles _Y N
Manholes 12"or less below grade Y N
[provide extension collar if Yes] Y N
Location/Separations
Foundation to tank ft.
Foundation to absorption ( ft.
Separation of Pits ft.
Conforms as per Plot Plan
Engineer Report and As-Built Y N
ETU Maintenance Contract provided N
Location of System on Property:
Front R r Left Side Right Side Middle Front Middle Rear
S stem Use Stat :
Approved
Partial Approved and needs to be re-inspected, please call the Building&Codes Office
Disapproved
Septic Inspection Report
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256 a — ‘C
Septic Inspection Report
Inspection request received:� 51!'Z1\t
_bpd bA-o, Inspected on: 5 22-120,1 S
•
Location: 1 L Pi O A' Pte,4-- Arrive: ' "�� a.m./p.m.
Permit No.: Y 5—1' 1 Inspector's Initials: AP ,nialli
Comments andlor diagram
Soil Type: an Loam/Clay
Type of r: Municipal/Well Water
Waterline separation distance ft.
Well separation distance ft. v ' / Z"-c_c,n. .4-
Other wells: ft.
Well Casing Length 50'+/- Y N N/A f -i -- - "� �R__) ,
[150'to well required if NO] --:51--
Absorption Field: Total length w ft. 1, r7E 1s44',- f,9
Length of each trench ft.
Depth of trenches ft. f7'RJl - 5 ,(
Size of Stonel'AAAs 1
Seepage Pits: Number
Size:
Stone Size:
Piping Size • Type
Building to tank 4`` A)(2, c
--.
Tank to Distribution Box c�"/
Distribution Box to Field/Pitit., `c S2—
Opening Sealed: N
End Cap ✓Y N
Inlet/Outlet Pipes&Baffles NL ,��,
Manholes 12"or less below grade YY /�- LJ�' ��
/�
[provide extension collar if Yes] _Y N Gr
Location/Separations ov �,�`- ��
'Fq, O �p /DOS
Foundation to tank t(./ ft. 1
Foundation to absorption ft. • ' v --
Conformsn of Pirs ft. v V I_W ` � '
Conforms as per Plot Plan N/
Engineer Report and As-Built Y IA
ETU Maintenance Contract provided Y N
Location of S st • on Prise :
Front 'ear Left Side Right Side Middle Front Middle Rear
System Use Status:
pproved
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved 0
Septic Inspection Report
7
sgi
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256 • 0--/el
iOlth
or eiertt r
Septic Inspection Report
Inspection request received: Si f
Name: '�fpil ('(c) - v., Inspected on: e /0 /,5
Location: I -71 1 Dv1-eer t6 i.,t ` 77Arrive: .tspo 4op• •..
Permit No.: R(') i. - 13 i !�`a Inspector's Initials: ,,
••� ments and/or dia•ram
Soil Type: Sand I Loam I Clay
Type of Water: Municipal/Well Water tR ]-
� e
Waterline separation distance ft.
Well separation distance ft. G'13� _ Co
a ,)-(, .
Other wells: ft. II
Well Casing Length 50'+/- Y N N/A
[150'to well required if NO]
Dam cr r
Absorption Field: Total length ft.
Length of each trench ft. (9i ) Cl/�i ,O alO A
Depth of trenches ft.
Size of Stone
Seepage Pits: Number
Size: x
Stone Size:
Piping Size Type
Building tolbrrlt-C[704 Q 31. oto WI 802_,b-----
Taggo Dim Kea.vA Ak► f 414 • r PLS 1 Fns NtRo,IS
Distribution Box to Field/Pit
Opening Sealed: _Y_N
End Cap _Y_N
Inlet/Outlet Pipes&Baffles _Y—N
Manholes 12"or less below grade _Y_N
[provide extension collar if Yes] _Y_N
Location I Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan __Y__N
Engineer Report and As-Built _Y__N
ETU Maintenance Contract provided _Y__N
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
System Use Status.
Approved
Partial Approved and needs to be re-inspected, please call the Building&Codes Office
Disapproved
Septic Inspection Report4
MAP REFERENCES
1. "MAP OF A SURVEY MADE FOR W- TERRANCE
AND JANE BARTON" DATED AUGUST 20, 2004, BY
VAN DUSEN & STEVES LAND SURVEYORS,
QUEENSBURY NY
2. "MAP OF A SURVEY MADE FOR MICHAEL &
PATRICIA O'CONNOR" DATED APRIL 12, 2013,
REVISED DECEMBER 2, 2013 BY VAN DUSEN &
STEVES LAND SURVEYORS, QUEENSBURY NY
3. "MAP OF A SURVEY MADE FOR ROBERT &
RENEE LITTLE AS TRUSTEES FOR THE ROBERT &
RENEE LITTLE REVOCABLE TRUST DATED JANUARY
4, 2013," REVISED MAY 7, 2014 BY VAN DUSEN &
STEVES LAND SURVEYORS, QUEENSBURY NY
289.14-1-17
LANDS N/F OF
COLLEEN HOGAN
6' t TO SHORE
DOCK
CIR5 \
/ o xx 10 GLEN
� I � 7 tic • v`,
289.14-1-19 �'S0 �`��� `XE
WATER TO CAMP
FROM LAKE ( -� LANDS OF 9F ••A�
LITTLE WATER TO CAMP
PROP. E -ONE
PROP. 1-1/4" I t1OUSE
HDPESDR-9 1
9.01± FORCE MAIN 1 3 -BEDROOM
PROP. 4" PVC -'�-I RESIDENCE
SDR -35 HIGH VENT ➢ Q
LINE FROM D -BOX C
TO HOUSE SEWER I
n� 1
O
I � E
PR
F� u PROP. E -ONE SEP ;
'-� GRINDER PUMP f
STATION
w' a
� PROP. HOUSE
SEWER
a
;LL
15TORY I1
WOOD FRAME
�, / -- House i
Qif
2 -BEDROOM '
rf SEASONAL
RESIDENCE
PUMP HOUSE
FOR WATER 5UPPLY 4
PROM LAKE ; - O
a' 289.14-1-I6� PROP. 1500 GAL
T'� LANDS OF STANDARD R/fTED
PRECAST CONCRETE /
/.% BARTON SEPTIC TANK;
/ PROP. DIST. a
Box AREA
PROP.
13,358 Sq.Ft.
4" MANIFOLD
& LOW VENT
0.31 acres
r,
KE
I
9.14-1-15 °45p'1g^ E
° LANDS OF
j0'CONNOR� _
i
O n/ !'$ AREA PP 420.41 '
x
y �l .F XO 334.6 Sfl I
o/y 0.24 Act WATER TO CAMPi
N 82
200.00'
0�-_ --- _
y 34 1p °
10,017 sq.ft.,
w� 0.23 acres
w tl 289.14-1-14 - 1�
o I LANDS OF—'--=-
m 3 LITTLE
a ; mIU EXIST.
+1 a
WELL I
N
EXTENSION TO GRADE WITH TRAFFIC RATED
CAST IRON MANHOLE COVER,
SYRACUSE CASTINGS 11020 OR EQUAL
PRECAST CONCRETE
RISER AS REQUIRED
4" PVC
INLET
ASPHALT SWAIF
N82`34'1,j
ton
12" MIN.
COVER
2'
a;
MIN. SLOPE
�'
I
Ie�PROX.
=-----
-- I
l
_XIIING
1/4" PER FOOT
c u�,
SEPTIC"
50-85%
1I
25-607
16"
SCUM
GRINDER PUMP - E/ONE DH071 (1 PER RESIDENCE)
0-10%
N n
0-2% (MUST BE OBTAINED
BY WASHING)
WATERTIGHT SLEEVE
KNOCK -OUTS IN THE DISTRIBU70N BOX TO THE HOUSE SEWER ORIENTED SLOPE
I
FIBER MAT DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
DESIGN PERCOLATION RATE = 1-5 MIN/IN
Drawn: LWD
AND SEAL (TIP.)
EFFLUENT
x�
1
1
SAND BED AREA PROVIDED = 496 SF
AES PIPE LENGTH REQUIRED =
LODGE
50 LF/BEDROOM x 5 -BEDROOMS = 250 LF
o
� �
INSTALL (10) LATERALS 0 30 LF IN 16'x31' SAND BED
foo
nI
M b
SITE PLAN
SCALE: I"=20'
APPROXIMATE
FINISH GRADE
GRINDER PUMP \ FROM LAKE ,
STATION
EXIST. HOLDING TANK \ \V, U,
TO BE ABANDONED
1 PROP.11/4"�
HDPE SDI
FORCE MAIN \
- I PUMP mou5r
' WATER TO CAMP \ \
FROM LAKE 5' ± TO SHORE
AREA
Io 12357.1 Sq.Ft. \
z 0.28 Acres aRs
cA�PO� - -
ROX
yOf T. \ I LANDS N/F OF
f�\ 1 0 P GARDNER
\
EXIST.
PROP. TRAFFIC RATED \ WELL
ABSORPTION BED
1111111111111111111 \ 596 SF W1300 LF
OF PRESBY AES PIPE I
Alk
1111111 � � £
gill
VIII IIII0111,1 it
IIII�IIIIII
111111111 JIII !I I RU511
STONE GRADE TO DRAIN
1 \ \
AWAY FROM PUMP
10.
Imo` I STATION
ORP16• �� S gPC'fr--1 � � � \
ED
ELECTRICAL - —
I
QUICK i
DISCONNECT
I: QUICK DISCONNECT yyi
'I ASSY
1I
APPROX.
EXISTING
SEPTIC ( 1 SS CAST BALL
VALVE
((( I
-0 O
N II
1.25' DISCHARGE
n\
— y
`� mma:sx
4" PVC SDR -35 BY-PASS
VENT FROM D -BOX TO
HOUSE SEWER LINE
�'
I
Ie�PROX.
=-----
-- I
l
_XIIING
WATER SAVING FIXTURES (INSTALL IF NECESSARY)
c u�,
SEPTIC"
50-85%
1I
25-607
SYSTEM DESIGN FLOW - 550 GPD
SCUM
GRINDER PUMP - E/ONE DH071 (1 PER RESIDENCE)
0-10%
N n
0-2% (MUST BE OBTAINED
BY WASHING)
I
KNOCK -OUTS IN THE DISTRIBU70N BOX TO THE HOUSE SEWER ORIENTED SLOPE
I
FIBER MAT DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
DESIGN PERCOLATION RATE = 1-5 MIN/IN
Drawn: LWD
y
EFFLUENT
(PER INSTALLATION MANUAL)
1
1
4" PVC SDR -35 BY-PASS
VENT FROM D -BOX TO
HOUSE SEWER LINE
MINIMUM 2X K10TH
MAXIMUM 4)WIDTH
n. n
1500 GAL PRECAST CONCRETE
SEPTIC TANK NOTES SEPTIC TANK TRAFFIC RATED
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE
DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED
BY UTOPIA ENTERPRISES OR EQUIVALENT.
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE.
WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE A STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY
CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUM SEALANT. JOINTS BELOW THE LIQUID LEVEL
MUST BE TESTED BEFORE BACKFILLING.
5
/ BAFFLE---—
Y PRECAST CONCRETE
DISTRIBUTION BOX
USE SPEED LEVELERS TO ASSURE -
ALL OUTLETS ARE AT EXACTLY
THE SAME ELEVATION
4" PVC SDR -35 SOLID HEADER TO -
PERFORATED ABSORPTION BED PIPING,
1/8" PER FOOT MIN SLOPE
SEPTIC TANK DETAIL
RID1
GEOTEXTILE
FABRIC
COARE
FIBER
BIO-ACCELE
I
,o Pay.
gOCELERAT OK F
ENVIRO-SEPTIC PIPE SECTION
N TS
MIN. SLOPE
SPACE
1/8" PER FOOT
100%
OUTLET 4" PVC EFFLUENT SEWER
18"MIN.
WATER SAVING FIXTURES (INSTALL IF NECESSARY)
_�-
(1.6 GPF MAX FLUSH, 3.0 GPM MAX. FAUCETS)
MINIMUM 2X K10TH
MAXIMUM 4)WIDTH
n. n
1500 GAL PRECAST CONCRETE
SEPTIC TANK NOTES SEPTIC TANK TRAFFIC RATED
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE
DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED
BY UTOPIA ENTERPRISES OR EQUIVALENT.
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE.
WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE A STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY
CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUM SEALANT. JOINTS BELOW THE LIQUID LEVEL
MUST BE TESTED BEFORE BACKFILLING.
5
/ BAFFLE---—
Y PRECAST CONCRETE
DISTRIBUTION BOX
USE SPEED LEVELERS TO ASSURE -
ALL OUTLETS ARE AT EXACTLY
THE SAME ELEVATION
4" PVC SDR -35 SOLID HEADER TO -
PERFORATED ABSORPTION BED PIPING,
1/8" PER FOOT MIN SLOPE
SEPTIC TANK DETAIL
RID1
GEOTEXTILE
FABRIC
COARE
FIBER
BIO-ACCELE
I
,o Pay.
gOCELERAT OK F
ENVIRO-SEPTIC PIPE SECTION
N TS
ELBOW LEVEL WITH TOP
OF OFFSET ADAPTOR
GEOTEXTILE
FIBER WRAP 2"-4" 1—I
RANDOMLY
ORIENTED
FIBER MAT m7
ENVTRO- -
SEPTIC PIPE
4" MAX INTO
)FFSET ADAPTOR
LBOW SIDE VIEW
PI AN VIS fr RAISED CONNECTION DETAIL
LEVEL
OFFSET
ADAPTOR
BACKFILL MATERIAL
BACKFILL MATERIAL TO BE GRANULAR BACKFILL MATERIAL WITH
NO PAR71CLES GREATER THAN 3
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/8" PER FOOT MINIMUM SLOPE.
STABILIZATION FABRIC
STABILIZATION FABRIC TO BE WOVEN GEOTEXTILE WITH
POLYPROPYLENE YARNS, TENCATE MIRAFI HP370 OR EQUIVALENT.
FORCEMAIN
PIPING TO BE 1-1/2' SDR -9 HDPE.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/4" PER FOOT MINIMUM SLOPE.
SYSTEM FILL
SYSTEM "SYSTEM FILL" MATERIAL SHALL BE SAND OR SANDY
LOAM WITH IN-PLACE PERCOLA77ON RATE OF 2-5 MIN/INCH. SEL
FILL MATERIAL NOTES FOR MORE INFORMATION.
SYSTEM SAND
SYSTEM SAND TO BE WASHED CONCRETE SAND CONFORMING TO
NYSDOT ASTM C-33 (SEE DESIGN AND INSTALLATION MANUAL FOR
COMPLETE SAND AND FILL SPECIFICATIONS)
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED.
MULCH, AND ESTABLISH TURF.
TEST PIT
TP -1 - 3/27/15 BY. T. HUTCHINS, P.E-
0-2" ASPHALT SURFACE
SILT
PRESBY SYSTEM SAND GRADATION
WASTEWATER SYSTEM DESIGN
SPACE
2 -BEDROOM SEASONAL RESIDENCE + 3 -BEDROOM RESIDENCE
100%
5 -BEDROOMS TOTAL
95-1007
WATER SAVING FIXTURES (INSTALL IF NECESSARY)
80-100%
(1.6 GPF MAX FLUSH, 3.0 GPM MAX. FAUCETS)
50-85%
DESIGN FLOW - 110 GPD/BEDROOM
25-607
SYSTEM DESIGN FLOW - 550 GPD
SCUM
GRINDER PUMP - E/ONE DH071 (1 PER RESIDENCE)
0-10%
SEPTIC TANK - (1) 1500 GAL PRECAST CONCRETE TANK
0-2% (MUST BE OBTAINED
BY WASHING)
LEACH FIELD - PRESBY ABSORPTION BED
KNOCK -OUTS IN THE DISTRIBU70N BOX TO THE HOUSE SEWER ORIENTED SLOPE
I
FIBER MAT DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
DESIGN PERCOLATION RATE = 1-5 MIN/IN
Drawn: LWD
SAND BED AREA REQUIRED = 469 SF
EFFLUENT
(PER INSTALLATION MANUAL)
169 Haviland Road
Queensbury, NY 12804
(518) 745-0307 Phone
Hutchins Engineering 518 745-0308 Fox
SAND BED AREA PROVIDED = 496 SF
AES PIPE LENGTH REQUIRED =
LODGE
50 LF/BEDROOM x 5 -BEDROOMS = 250 LF
AES PIPE LENGTH PROVIDED = 300 LF
STACK EXISTS WITHIN THE HOUSE AND THAT A TRAP IS NOT �� PIPING HAS BEEN INSTALLED.
ENVIRO-SEPTIC
INSTALL (10) LATERALS 0 30 LF IN 16'x31' SAND BED
POTABLE WATER SUPPLY IS EXISTING LAKE WATER SUPPLY
SYSTEM MATERIAL SPECIFICATIONS
ELBOW LEVEL WITH TOP
OF OFFSET ADAPTOR
GEOTEXTILE
FIBER WRAP 2"-4" 1—I
RANDOMLY
ORIENTED
FIBER MAT m7
ENVTRO- -
SEPTIC PIPE
4" MAX INTO
)FFSET ADAPTOR
LBOW SIDE VIEW
PI AN VIS fr RAISED CONNECTION DETAIL
LEVEL
OFFSET
ADAPTOR
BACKFILL MATERIAL
BACKFILL MATERIAL TO BE GRANULAR BACKFILL MATERIAL WITH
NO PAR71CLES GREATER THAN 3
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/8" PER FOOT MINIMUM SLOPE.
STABILIZATION FABRIC
STABILIZATION FABRIC TO BE WOVEN GEOTEXTILE WITH
POLYPROPYLENE YARNS, TENCATE MIRAFI HP370 OR EQUIVALENT.
FORCEMAIN
PIPING TO BE 1-1/2' SDR -9 HDPE.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/4" PER FOOT MINIMUM SLOPE.
SYSTEM FILL
SYSTEM "SYSTEM FILL" MATERIAL SHALL BE SAND OR SANDY
LOAM WITH IN-PLACE PERCOLA77ON RATE OF 2-5 MIN/INCH. SEL
FILL MATERIAL NOTES FOR MORE INFORMATION.
SYSTEM SAND
SYSTEM SAND TO BE WASHED CONCRETE SAND CONFORMING TO
NYSDOT ASTM C-33 (SEE DESIGN AND INSTALLATION MANUAL FOR
COMPLETE SAND AND FILL SPECIFICATIONS)
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED.
MULCH, AND ESTABLISH TURF.
TEST PIT
TP -1 - 3/27/15 BY. T. HUTCHINS, P.E-
0-2" ASPHALT SURFACE
SILT
PRESBY SYSTEM SAND GRADATION
SIEVE
PERCENT PASSING
3/8" (9.5 -mm)
100%
No. 4 (4.75 -mm)
95-1007
No. 8 (2.36 -mm)
80-100%
No. 16 (1.18 -mm)
50-85%
No. 30 (600 -tun)
25-607
No. 50 (301
5-30X
No. 100 (150 -pm)
0-10%
No. 200 (75 -pm)
0-2% (MUST BE OBTAINED
BY WASHING)
�
I CHECK VALVETHE
2-30 MEDIUM BROWN GRAVELLY SAND, SOME
CONTRACTOR SHALL SUBMIT SIEVE ANALYSIS ID LNGINLLK ruN
HDPE GASKETED LID STRAIN RELIEF CORD
50% COBBLES & BOULDERS
APPROVAL PRIOR TO PLACEMENT OF SYSTEM SAND,
CONNECTOR30-74"
\
�'
MEDIUM BROWN GRAVELLY SAND, SOME SILT
GRINDEL R NOTES
70% COBBLES & BOULDERS
SYSTEM INSTALLS
1
ALL OPENINGS WATERTIGHT.
DRY EN77RE DEPTH, NO GROUNDWATER EVIDENCE ENCOUNTERED
SHOWNONTHISDRAWINGAND IN
KNOCK -OUTS IN THE DISTRIBU70N BOX TO THE HOUSE SEWER ORIENTED SLOPE
I
FIBER MAT DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
WASTEWATER REPLACEMENT PLAN
prepared for:
Terry & Jane Barton & Colleen Hogan
17 & 19 Pioneer Point - Glen Lake
Town of Queensbury, Warren County, NY
Drawn: LWD
Checked: GTH
ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL
Date: 12/19/2014
169 Haviland Road
Queensbury, NY 12804
(518) 745-0307 Phone
Hutchins Engineering 518 745-0308 Fox
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP
HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF
v'
CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM.
STACK EXISTS WITHIN THE HOUSE AND THAT A TRAP IS NOT �� PIPING HAS BEEN INSTALLED.
ENVIRO-SEPTIC
THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK
OFF
INSTALL CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE
LEACH FIELDS.
18"
-- PROTECTIVE
—
I
t
I—
LOCATION.
SYSTEM 70 BE INSTALLED IN ACCORDANCE WITH PRODUCT DESIGN
- CABLE
-
14"
INSTALL POWER & CONTROL WIRING TO CONTROLLER
AND INSTALLATION MANUAL, STATE AND LOCAL REGULATIONS. FOR
(HDPE) =I I
PUMP OFF
WITH ALARM IN HOUSE IN ACCORDANCE KITH
PRODUCT INFORMATION OR THE NEAREST DEALER CONTACT PRESBY
NATIONAL ELECTRIC CODE (N.EC) REQUIREMENTS.
ENVIRONMENTAL, INC. 143 AIRPORT ROAD, WHITEFIELD, NH 03598,
\
PHONE 1-800-473-5298 WWW.PRESBYENWRONMENTAL.COM
POWER/ALARM CABLE
SET ALARM LEVEL AS INDICATED.
AFTER EXCAVATION OF ABSORPTION BED TO THE DEPTHS REQUIRED,
J? PUMP.
774E WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND
E/ONE EQUALIZER
Q
RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH.
—
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO
4"0 LOW VENT ATTACHED
PURCHASING POM, .
TO VENT MANIFOLD �
PLACEMENT OF SYSTEM SAND, PRESBY ENVIRO SEPTIC® PIPE AND
2"0 INTERNAL WELL
SCREEN OPENING
FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED
VENT
AN ELECTRICAL INSPECTION BY CERTIFIED ELECTRICAL
TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN
- 91
8"
INSPECTION AGENCY IS REWIRED PRIOR TO START-UP
THE PIPE.
- INLET GROMMET TO ACCEPT
OF PUMP STATION. ELECTRICAL INSPECTION SEAL IS
3'
- 4.5" O.D. PVC HOUSE SEWER
TO BE AFFIXED TO PUMP STA77ON CONTROL PANEL.
ELBOW LEVEL WITH TOP-
MINIMUM OF 6" OF SYSTEM SAND, MEETING SPECIFIED GRADATION,
s
OF OFFSET ADAPTOR
ARUND MFERENCE OF ADVANCED ENWRO-SEP77C
--4'
ABSORPTION FIELD VENTING NOTE
APES. (SEE DESIGN AND I STALLA71ON MANUAL FOR COMPLETE SAND
THE PRESBY AES ABSORPTION FIELD REWIRES HIGH AND LOW
MW. TOPSOIL
AND FILL SPECIFICATIONS.)
f -
VENTING, WITH THE LOW VENTING BEING PROVIDED BY MANIFOLD
\
,
PIPING THE ENDS OF THE PRESBY AES LATERALS AND
, \\\\ \ \\ \ \ �\
\/j �,\.,\.� /\/�,/, �;\y\\j\j\\j\\j\j
\ \j THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING
ALARM
CONNECTING TO A STAND PIPE, 3' MINIMUM ABOVE FINISHED
STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED
GRADE..
GEOTEXTILE
—� T y �
JOINTS, OR OWNER UNSUITABLE CONDITIONS.
INLET
FIBER WRAP 2 4 f
�� I
DUAL WALL - SEMI -POSITIVE
CORRUGATED HDPE — - - 0 29.5 --- DISPLACEMENT TYPE
TANK PUMP
EIONE DH071 GRINDER PULP ASSEMBLY DETAIL
12" MIN.
COVER 2" MIN. DROP
BETWEEN INVERTS
2" MIN.
STABILIZATION ROAD FABRIC OVER SYSTEM12" MIN. GRAVEL SUBBASE 20 MIN.
SAND & 3' BEYOND EDGES OF SAND 9ELOW PAVEMENT AS
"I nnum nnnr°nrn
EXCAVATE NATIVE COBBLY, BOULDERY SAND 70 12" MIN. I' VENT MANII OLD - ENWRO-SEPTIC PIPE (TYP.) SYSTEM SAND
BELOW SYSTEM & BACKFILL W/FINE-MEDIUM SAND FILL
ABSORPTION FIELD SECTION - TRAFFIC RATED
NTS
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE
MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM.
Qj
CONSTRUCTION.DEPARTMENT
TO Cq"IVIG DEPART�LWW YORK PRIOR TO
VENT DETAIL Based on our limited examination, compliance
with our comments shalt not be construed as
NTS TOWN OF QUEENSBURY indicating the plans and specifications are in
BUILDING & COD S T. Newco rk Sta H1tn the Building Codes of
Reviewed By:
Date: t �_• �_
2015
Barton/Clark BP 2015-131 TOWN OF QUEENSBURY
445 Ridge Road (�ODES
Septic Alterations 289.14-1-16 -
Dig PSafely.
New/York
10 Call Before You Dig
19 Walt The Required Time
® Confirm Utility Response
® Respect The Marks
® Dig With Care
800.962"7962
ww dlgsafelynewyork.eom
TAX MAP # 289.14-1-16 & 17
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL
ENGINEER IS A VIOLATION OF NYS EDUCATION LAW
I CHECK VALVETHE
T
HIGH VEN7ING IS PROVIDED THROUGH THE BUILDING'S MAIN = LVF J ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND
RANDOMLY
41.6'
�'
THROUGH -THE -ROOF PLUMBING VENT, BY PIPING ONE OF THE , I DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DISCHARGE
0
[ �'h
26"
_T
No.
Revisions
KNOCK -OUTS IN THE DISTRIBU70N BOX TO THE HOUSE SEWER ORIENTED SLOPE
I
FIBER MAT DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
WASTEWATER REPLACEMENT PLAN
prepared for:
Terry & Jane Barton & Colleen Hogan
17 & 19 Pioneer Point - Glen Lake
Town of Queensbury, Warren County, NY
Drawn: LWD
Checked: GTH
ALRM
Date: 12/19/2014
169 Haviland Road
Queensbury, NY 12804
(518) 745-0307 Phone
Hutchins Engineering 518 745-0308 Fox
LINE. IT MUST BE VERIFIED THAT A THROUGH -THE -ROOF VENT
I
STACK EXISTS WITHIN THE HOUSE AND THAT A TRAP IS NOT �� PIPING HAS BEEN INSTALLED.
ENVIRO-SEPTIC
OFF
OFFSE
INSTALLED IN THE MAIN HOUSE SEWER LINE. I - T
PIPE ADAPTOR THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS
ANTI -SIPHON
18"
I
IF EITHER OF THESE RESTRICTIONS EXIST, THEN A HIGH -VENT I NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME
VALVE
PUMP ON
MUST BE PROVIDED, IN WHICH THE DISTRIBU77ON BOX KNOCK -OUT SYSTEM SAND I ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR
-
14"
IS PIPED TO A VERTICAL STAND PIPE WHICH IS 10 -FT HIGHER ` _ — — — _ — — -,.-J GARBAGE GRINDERS.
PUMP OFF
THAN THE LOW VENT.
DUAL WALL - SEMI -POSITIVE
CORRUGATED HDPE — - - 0 29.5 --- DISPLACEMENT TYPE
TANK PUMP
EIONE DH071 GRINDER PULP ASSEMBLY DETAIL
12" MIN.
COVER 2" MIN. DROP
BETWEEN INVERTS
2" MIN.
STABILIZATION ROAD FABRIC OVER SYSTEM12" MIN. GRAVEL SUBBASE 20 MIN.
SAND & 3' BEYOND EDGES OF SAND 9ELOW PAVEMENT AS
"I nnum nnnr°nrn
EXCAVATE NATIVE COBBLY, BOULDERY SAND 70 12" MIN. I' VENT MANII OLD - ENWRO-SEPTIC PIPE (TYP.) SYSTEM SAND
BELOW SYSTEM & BACKFILL W/FINE-MEDIUM SAND FILL
ABSORPTION FIELD SECTION - TRAFFIC RATED
NTS
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE
MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM.
Qj
CONSTRUCTION.DEPARTMENT
TO Cq"IVIG DEPART�LWW YORK PRIOR TO
VENT DETAIL Based on our limited examination, compliance
with our comments shalt not be construed as
NTS TOWN OF QUEENSBURY indicating the plans and specifications are in
BUILDING & COD S T. Newco rk Sta H1tn the Building Codes of
Reviewed By:
Date: t �_• �_
2015
Barton/Clark BP 2015-131 TOWN OF QUEENSBURY
445 Ridge Road (�ODES
Septic Alterations 289.14-1-16 -
Dig PSafely.
New/York
10 Call Before You Dig
19 Walt The Required Time
® Confirm Utility Response
® Respect The Marks
® Dig With Care
800.962"7962
ww dlgsafelynewyork.eom
TAX MAP # 289.14-1-16 & 17
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL
ENGINEER IS A VIOLATION OF NYS EDUCATION LAW
0
ISSUED FOR PERMIT
5/1/15
No.
Revisions
Date
WASTEWATER REPLACEMENT PLAN
prepared for:
Terry & Jane Barton & Colleen Hogan
17 & 19 Pioneer Point - Glen Lake
Town of Queensbury, Warren County, NY
Drawn: LWD
Checked: GTH
Scale: NOTED
Date: 12/19/2014
169 Haviland Road
Queensbury, NY 12804
(518) 745-0307 Phone
Hutchins Engineering 518 745-0308 Fox
29838-01
I 0 1-1/4" Ile
TO +� 2"HDPESDR-9\ AREA \
HDPE SDR -9 �� o FORCE MAIN 12357.1 Sq.Ft. \ ,
FORCE MAIN z 0.28 Acres .1K5
k 2 E -ONE SEP 4,
A3Ci g` I GRINDER PUMP SF
_ STATION i \ / CA�POPIT \
�l
4' HOUSE
SEWER PROX.
LANDS N/F OF
P EPO�� iGARDNER
o I \ O PF
I STORY
I WOOD FRAME
4r - MOUSE 1F•4la0'+
° 2 -BEDROOM
jj SEASONAL
cs ( RESIDENCE n \ I n \
PUMP HOU5E
FOR WATER 5UPPLY h ~ Z3• ' \ \ I ��F�
FROM LAKE m
TRAFFIC RATED \�
om 289.14-1-16 / HIGH EN 596 SF W1300 LF EXIST.
\ F ABSORPTION BED \
LANDS OF
BARTON / l000 GA • I \ S \ OF PRESBYAES PIPE � WELL
PRECAST
11uul1uia1111111I I
SEPTIC TANK \ \
46-'F PRECAST CONC. s I 111111111111111111 \ \ �.
( DIST. BOX
AREA 11111111111111111
GLEX 13,358 Sq.Ft. �c
0.31 acres •FkV" II 1111111111111111111 �� ro �c�F
rjj'°^°� 3 0 0 /� 111 IIIIIIIIIIIIIIIII�e�
LAKE N� ' ,�yv111111111111111 �� cRUSnEU v4F
STONE GRADE TO DRAIN
\ \
r ID a \ AWAY FROM Pump
STATION
9.14-1-15 s � as'1B" -
E
LANDS OF \ `L
`z0'CONNOR
A
�I AREazoai '�� ELECTRICAL
y ° 0 334.6 .F 5 ii _ _ / QUICK
S
DISCONNECT
.
i
024 Acx
/h WATER TO CAMP'',
",FROM KE
QUICK DISCONNECT
ASSY
L
APPROX. l ,
EXISTING'
SEPTIC J 1 SS CAST BALL
VALVE
200.00'
5 N;82°34"
W
10,017 aq.ft. �� C; �
0.23 acres 1.25" DISCHARGE
tl 289.14-1-14 ti \
u..........
o I LANDS OF
I
PHONE 1-800-473-5298 WWW.PRESBYENVIRONMENTAL.COM
6' ± TO
SHORE
_'
NIS
m
O
MAP REFERENCES
a ;
M
EXIST.
_
+
m_
I
�I�
o
zl
WELL
No.
N •
N
25-60%
No.
DOCK
5-30%
1. "MAP OF A SURVEY MADE FOR W. TERRANCE
�►-
'
No.
200 (75 -Nm)
'
1482°34'10"W
AND JANE BARTON" DATED AUGUST 20, 2004, BY
ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL
HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF
AN ELECTRICAL INSPECTION BY CERTIFIED ELECTRICAL
•
aRs
507 COBBLES & BOULDERS
THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK
VAN DUSEN & STEVES LAND SURVEYORS,
4.5" O.D. PVC HOUSE SEWER
PIPING HAS BEEN INSTALLED.
INSTALL CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE
30-74" MEDIUM BROWN GRAVELLY SAND, SOME SILT
y
NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME
QUEENSBURY NY
ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR
PROTECTIVE
LOCATION.
\
`pC\ .
2. "MAP OF A SURVEY MADE FOR MICHAEL &
CABLE SHROUD
VENT DETAIL
CONSTRUCTION.
SYSTEM TO BE INSTALLED IN ACCORDANCE WITH PRODUCT DESIGN
PATRICIA O'CONNOR" DATED APRIL 12, 2013,
(HDPE)
INSTALL POWER & CONTROL WIRING TO CONTROLLER
DRY ENTIRE DEPTH, NO GROUNDWATER EVIDENCE ENCOUNTERED
A
q�0,
REVISED DECEMBER $ 2013 BY VAN DUSEN &
CONNECTING TO A STAND PIPE, 3' MINIMUM ABOVE FINISHED
GEOTEXTILE
0
2
��(EJV
`T ✓ �
SIEVES LAND SURVEYORS, QUEENSBURY NY
"MAP
INLET
/
Io
�'i
sti0�
�1Ii�
3. OF A SURVEY MADE FOR ROBERT &
289.14-1-17
WATER
RANDOMLY
I�
289.14-1-19
\ 9
.AXE
RENEE LITTLE AS TRUSTEES FOR THE ROBERT &
FROM AKE
LANDS OF F
KNOCK -OUTS IN THE DISTRIBUTION BOX TO THE HOUSE SEWER
RENEE LITTLE REVOCABLE TRUST DATED JANUARY
LANDS NIF OF
LINE. IT MUST BE VERIFIED THAT A THROUGH-7HE-ROOF VENT
\ LITTLE w CAMP
4, 2013," REVISED MAY 7, 2014 BY VAN DUSEN &
COLLEEN HOGAN
STACK EXISTS WITHIN THE HOUSE AND THAT A TRAP IS NOT
ENVIRO-SEPTIC
\ FROM
FPPOM LAKE
STEVES LAND SURVEYORS, QUEENSBURY NY
18
EXIST. 3500 GAA
\
PIPE
PUMP„ON
,._
IF EITHER OF THESE RESTRIC77ONS EXIST, THEN A HIGH -VENT
HOLDING TANK
CONVERTED
\gpO LP '
'
PROVIDED,KNOCK-OUT
14"
TO SEPTIC TANK
IS PIPED VERTIC L STANDS PIPE WHICH ISO10 -FT HIGHER
PUMP OFF
THAN THE LOW VENT.
i S
HOUSE
\
9.0'±
3-BEDRO0Iy
a
<P�
PUMPHOUSE
RESIDENCE
O
IRSIx
,�',�
\
_
M
q.a, 500 GAL WATER TO CAMP \
PUMP STATION ' /
37 ` 18. _�
e°
�y4
x
m
O
.417.7
FROM LAKE
\
5' ± TO SHORE
I 0 1-1/4" Ile
TO +� 2"HDPESDR-9\ AREA \
HDPE SDR -9 �� o FORCE MAIN 12357.1 Sq.Ft. \ ,
FORCE MAIN z 0.28 Acres .1K5
k 2 E -ONE SEP 4,
A3Ci g` I GRINDER PUMP SF
_ STATION i \ / CA�POPIT \
�l
4' HOUSE
SEWER PROX.
LANDS N/F OF
P EPO�� iGARDNER
o I \ O PF
I STORY
I WOOD FRAME
4r - MOUSE 1F•4la0'+
° 2 -BEDROOM
jj SEASONAL
cs ( RESIDENCE n \ I n \
PUMP HOU5E
FOR WATER 5UPPLY h ~ Z3• ' \ \ I ��F�
FROM LAKE m
TRAFFIC RATED \�
om 289.14-1-16 / HIGH EN 596 SF W1300 LF EXIST.
\ F ABSORPTION BED \
LANDS OF
BARTON / l000 GA • I \ S \ OF PRESBYAES PIPE � WELL
PRECAST
11uul1uia1111111I I
SEPTIC TANK \ \
46-'F PRECAST CONC. s I 111111111111111111 \ \ �.
( DIST. BOX
AREA 11111111111111111
GLEX 13,358 Sq.Ft. �c
0.31 acres •FkV" II 1111111111111111111 �� ro �c�F
rjj'°^°� 3 0 0 /� 111 IIIIIIIIIIIIIIIII�e�
LAKE N� ' ,�yv111111111111111 �� cRUSnEU v4F
STONE GRADE TO DRAIN
\ \
r ID a \ AWAY FROM Pump
STATION
9.14-1-15 s � as'1B" -
E
LANDS OF \ `L
`z0'CONNOR
A
�I AREazoai '�� ELECTRICAL
y ° 0 334.6 .F 5 ii _ _ / QUICK
S
DISCONNECT
.
i
024 Acx
/h WATER TO CAMP'',
",FROM KE
QUICK DISCONNECT
ASSY
L
APPROX. l ,
EXISTING'
SEPTIC J 1 SS CAST BALL
VALVE
200.00'
5 N;82°34"
W
10,017 aq.ft. �� C; �
0.23 acres 1.25" DISCHARGE
tl 289.14-1-14 ti \
u..........
o I LANDS OF
I
4" PVC
INLET
MIN. SLOPE
1/4" PER FOOT
WATERTIGHT SLEEVE-,
AND SEAL (TIP.)
SITE PLAN
SCALE: 1'=20'
APPROXIMATE
rFINISH GRADE
3
0
4" PVC SDR -35
BY-PASS VENT
CHECK VALVE
41.6"
DISCHARGE
ANTI -SIPHON
VALVE
RID
GEOTEXTILE
FABRIC
COAR�
FI BER
BIO-ACCELE
I
P$
\ACCELERATOFe F
ENVIRO-SEPTIC PIPE SECTION
NTS
WASTEWATER SYSTEM DESIGN
SPACE 2 -BEDROOM SEASONAL RESIDENCE - BARTON
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 220 GPD'
PUMP STATION - E -ONE DH071 GRINDER PUMP STATION
SEPTIC TANK - 1000 GAL PRECAST CONCRETE
SCUM 3 -BEDROOM SEASONAL RESIDENCE - HOGAN
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
SEPTIC TANK - EXIST. 3500 GAL PRECAST CONCRETE f
HOLDING TANK CONVERTED TO SEPTIC TANK /J
EFFLUENT PUMP STATION - 500 GAL PRECAST CONCRETE /
LEACH FIELD - PRESBY ABSORPTION BED j -moi J
_UDGE ABSORPTION FIELD SYSTEM DESIGN FLOW - 550 GPD
DESIGN PERCOLATION RATE = 1-5 MIN/IN
SAND BED AREA REQUIRED = 469 SF
(PER INSTALLATION MANUAL)
SAND BED AREA PROVIDED = 496 SF
AES PIPE LENGTH REQUIRED = A� r
50 LF/BEDROOM x 5 -BEDROOMS = 250 LF
AES PIPE LENGTH PROVIDED = 300 LF"mom
INSTALL (10) LATERALS ® 30 LF IN 16'x31' SAND BED
POTABLE WATER SUPPLY IS EXISTING LAKE WATER SUPPLY `.
SYSTEM MATERIAL SPECIFICATIONS
ELBOW LEVEL WITH TOP
OF OFFSET ADAPTOR
GEOTEXTILE
FIBER WRAP 2"-4"
+ � LEVEL
RANDOMLY
ORIENTED
FIBER MAT
ENVIRO-
SEPTIC PIPE
4" MAX INTO
)FFSET ADAPTOR
LBOW SIDE VIEW
PLAN VIEW RAISED CONNECTION DETAIL
OFFSET
ADAPTOR
BACKFILL MATERIAL
BACKFILL MATERIAL TO BE GRANULAR BACKFILL MATERIAL WITH
NO PARTICLES GREATER THAN 3".
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/8" PER FOOT MINIMUM SLOPE.
STABILIZATION FABRIC
STABILIZATION FABRIC TO BE WOVEN GEOTEX77LE WITH
POLYPROPYLENE YARNS, TENCATE MIRAFI HP370 OR EQUIVALENT,
FORCEMAIN
PIPING TO BE 1-1/2" SDR -9 HDPE.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/4" PER FOOT MINIMUM SLOPE.
SYSTEM FILL
SYSTEM "SYSTEM FILL" MATERIAL SHALL BE SAND OR SANDY
LOAM WITH IN-PLACE PERCOLATION RATE OF 2-5 MINANCH. SEE
FILL MATERIAL NOTES FOR MORE INFORMATION.
SYSTEM SAND
SYSTEM SAND TO BE WASHED CONCRETE SAND CONFORMING TO
NYSDOT ASTM C-33 (SEE DESIGN AND INSTALLATION MANUAL FOR
COMPLETE SAND AND FILL SPECIFICATIONS)
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED,
SITE LOCATION —J LOCATION MAP
PRESBY SYSTEM SAND GRADATION
PHONE 1-800-473-5298 WWW.PRESBYENVIRONMENTAL.COM
LITTLE
PERCENT PASSING
_'
NIS
m
O
PROX
a ;
M
EXIST.
EXI N(
SEPTIC
+
m_
I
�I�
o
zl
WELL
No.
N •
N
25-60%
No.
50 (300-µm)
5-30%
No.
ASPHALT 5WALE --�
0-107
No.
200 (75 -Nm)
0-2% (MUST BE OBTAINED
BY WASHING)
1482°34'10"W
4" PVC
INLET
MIN. SLOPE
1/4" PER FOOT
WATERTIGHT SLEEVE-,
AND SEAL (TIP.)
SITE PLAN
SCALE: 1'=20'
APPROXIMATE
rFINISH GRADE
3
0
4" PVC SDR -35
BY-PASS VENT
CHECK VALVE
41.6"
DISCHARGE
ANTI -SIPHON
VALVE
RID
GEOTEXTILE
FABRIC
COAR�
FI BER
BIO-ACCELE
I
P$
\ACCELERATOFe F
ENVIRO-SEPTIC PIPE SECTION
NTS
WASTEWATER SYSTEM DESIGN
SPACE 2 -BEDROOM SEASONAL RESIDENCE - BARTON
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 220 GPD'
PUMP STATION - E -ONE DH071 GRINDER PUMP STATION
SEPTIC TANK - 1000 GAL PRECAST CONCRETE
SCUM 3 -BEDROOM SEASONAL RESIDENCE - HOGAN
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
SEPTIC TANK - EXIST. 3500 GAL PRECAST CONCRETE f
HOLDING TANK CONVERTED TO SEPTIC TANK /J
EFFLUENT PUMP STATION - 500 GAL PRECAST CONCRETE /
LEACH FIELD - PRESBY ABSORPTION BED j -moi J
_UDGE ABSORPTION FIELD SYSTEM DESIGN FLOW - 550 GPD
DESIGN PERCOLATION RATE = 1-5 MIN/IN
SAND BED AREA REQUIRED = 469 SF
(PER INSTALLATION MANUAL)
SAND BED AREA PROVIDED = 496 SF
AES PIPE LENGTH REQUIRED = A� r
50 LF/BEDROOM x 5 -BEDROOMS = 250 LF
AES PIPE LENGTH PROVIDED = 300 LF"mom
INSTALL (10) LATERALS ® 30 LF IN 16'x31' SAND BED
POTABLE WATER SUPPLY IS EXISTING LAKE WATER SUPPLY `.
SYSTEM MATERIAL SPECIFICATIONS
ELBOW LEVEL WITH TOP
OF OFFSET ADAPTOR
GEOTEXTILE
FIBER WRAP 2"-4"
+ � LEVEL
RANDOMLY
ORIENTED
FIBER MAT
ENVIRO-
SEPTIC PIPE
4" MAX INTO
)FFSET ADAPTOR
LBOW SIDE VIEW
PLAN VIEW RAISED CONNECTION DETAIL
OFFSET
ADAPTOR
BACKFILL MATERIAL
BACKFILL MATERIAL TO BE GRANULAR BACKFILL MATERIAL WITH
NO PARTICLES GREATER THAN 3".
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/8" PER FOOT MINIMUM SLOPE.
STABILIZATION FABRIC
STABILIZATION FABRIC TO BE WOVEN GEOTEX77LE WITH
POLYPROPYLENE YARNS, TENCATE MIRAFI HP370 OR EQUIVALENT,
FORCEMAIN
PIPING TO BE 1-1/2" SDR -9 HDPE.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/4" PER FOOT MINIMUM SLOPE.
SYSTEM FILL
SYSTEM "SYSTEM FILL" MATERIAL SHALL BE SAND OR SANDY
LOAM WITH IN-PLACE PERCOLATION RATE OF 2-5 MINANCH. SEE
FILL MATERIAL NOTES FOR MORE INFORMATION.
SYSTEM SAND
SYSTEM SAND TO BE WASHED CONCRETE SAND CONFORMING TO
NYSDOT ASTM C-33 (SEE DESIGN AND INSTALLATION MANUAL FOR
COMPLETE SAND AND FILL SPECIFICATIONS)
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED,
SITE LOCATION —J LOCATION MAP
PRESBY SYSTEM SAND GRADATION
PHONE 1-800-473-5298 WWW.PRESBYENVIRONMENTAL.COM
SIEVE
PERCENT PASSING
3/8" (9.5 -mm)
100%
No.
4 (4.75 -mm)
95-100%
No.
8 (2.36 -mm)
80-100%
No.
16 (1.18 -mm)
50-85%
No.
30 (600-µm)
25-60%
No.
50 (300-µm)
5-30%
No.
100 (150 -pm)
0-107
No.
200 (75 -Nm)
0-2% (MUST BE OBTAINED
BY WASHING)
ALARM
PHONE 1-800-473-5298 WWW.PRESBYENVIRONMENTAL.COM
MULCH, AND ESTABLISH TURF.
CONTRACTOR SHALL SUBMIT SIEVE ANALYSIS TO ENGINEER FOR
HDPE GASKETED LID STRAIN RELIEF CORD
THE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND
NATIONAL ELECTRIC CODE (N.E.C.) REQUIREMENTS.
APPROVAL PRIOR TO PLACEMENT OF SYSTEM SAND.
CONNECTOR
PLACEMENT OF SYSTEM SAND, PRESBY ENVIRO-SEPTIC® PIPE AND
TEST PIT
FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED
GRINDER PUMP NOTES
PUMP TO BE EIONE DH071 GRINDER PUMP.
SYSTEM INSTALLATION NOTES
E/ONE EQUALIZER
MINIMUM OF 6" OF SYSTEM SAND, MEETING SPECIFIED GRADATION,
TP -1 - 3/27/15 BY. I. HUTCHINS, P.E.
REQUIRED AROUND CIRCUMFERENCE OF ADVANCED ENWRO-SEPTIC
SEAL ALL TANK OPENINGS WATERTIGHT.
0-2" ASPHALT SURFACE
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN
N 2"0 INTERNAL WELL
\ \\ \.
A/A/ THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP
2-30" MEDIUM BROWN GRAVELLY SAND, SOME SILT
ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL
HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF
AN ELECTRICAL INSPECTION BY CERTIFIED ELECTRICAL
•
- CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM.
507 COBBLES & BOULDERS
THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
4.5" O.D. PVC HOUSE SEWER
PIPING HAS BEEN INSTALLED.
INSTALL CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE
30-74" MEDIUM BROWN GRAVELLY SAND, SOME SILT
LEACH FIELDS.
NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME
ABSORPTION FIELD VENTING NOTE
ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR
PROTECTIVE
LOCATION.
70% COBBLES & BOULDERS
ROOF FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE
THE PRESBY AES ABSORPTION FIELD REQUIRES HIGH AND LOW
CABLE SHROUD
VENT DETAIL
CONSTRUCTION.
SYSTEM TO BE INSTALLED IN ACCORDANCE WITH PRODUCT DESIGN
(HDPE)
INSTALL POWER & CONTROL WIRING TO CONTROLLER
DRY ENTIRE DEPTH, NO GROUNDWATER EVIDENCE ENCOUNTERED
AND INSTALLATION MANUAL, STATE AND LOCAL REGULATIONS. FOR
ALARM
DUAL WALL — SEMI -POSITIVE
CORRUGATED HDPE 0 29.5" DISPLACEMENT TYPE
TANK PUMP
El ONE DHO71 GRINDER PUMP ASSEMBLY DETAIL
12" MIN.
a a COVER 2" MIN. DROP
MIN. SLOPE
BETWEEN INVERTS
2" 1/8" PER FOOT_
2" MIN.
IIOUID LEVEL OU11ET 4" PVC EFFLUENT SEWER
' I 116"18"MIN.
�
off¢
foo
• J
2X WIDTH
1000 GAL PRECAST CONCRETE SEPTIC TANK
SEPTIC TANK NOTES
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE
DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED
/ BAFFLE ---
PRECAST CONCRETE
DISTRIBUTION BOX
USE SPEED LEVELERS TO ASSURE -
ALL OUTLETS ARE AT EXACTLY
THE SAME ELEVATION
4" PVC SDR -35 SOLID HEADER 70 -
PERFORATED ABSORPTION BED PIPING,
1/8" PER FOOT MIN SLOPE
BY UTOPIA ENTERPRISES OR EQUIVALENT. SEPTIC TANK DETAIL
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. NTS
WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE A STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY
CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL
MUST BE TESTED BEFORE BACKFILLING.
PRODUCT INFORMATION OR THE NEAREST DEALER CONTACT PRESBY
ENVIRONMENTAL, INC. 143 AIRPORT ROAD, WHITEFIELD, NH 03598,
PHONE 1-800-473-5298 WWW.PRESBYENVIRONMENTAL.COM
WITH ALARM IN HOUSE IN ACCORDANCE WITH
AFTER EXCAVATION OF ABSORPTION BED TO THE DEPTHS REQUIRED,
POWER/ALARM CABLE
THE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND
NATIONAL ELECTRIC CODE (N.E.C.) REQUIREMENTS.
RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH.
4"0 LOW VENT ATTACHED
TO VENT MANIFOLD
PLACEMENT OF SYSTEM SAND, PRESBY ENVIRO-SEPTIC® PIPE AND
SET ALARM LEVEL AS INDICATED.
FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED
TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN
PUMP TO BE EIONE DH071 GRINDER PUMP.
THE PIPE.
E/ONE EQUALIZER
MINIMUM OF 6" OF SYSTEM SAND, MEETING SPECIFIED GRADATION,
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO
REQUIRED AROUND CIRCUMFERENCE OF ADVANCED ENWRO-SEPTIC
PIPES. (SEE DESIGN AND INSTALLATION MANUAL FOR COMPLETE SAND
PURCHASING PUMP.
AND FILL SPECIFICATIONS.)
N 2"0 INTERNAL WELL
\ \\ \.
A/A/ THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING
STRAIGHT CONTINUOUS GRADES K1774OUT SAGS, HUMPS, SEPARATED
VENT
JOINTS, OR OTHER UNSUITABLE CONDITIONS.
AN ELECTRICAL INSPECTION BY CERTIFIED ELECTRICAL
J ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND
INLET GROMMET TO ACCEPT 91.8"
DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
INSPECTION AGENCY IS REQUIRED PRIOR TO START-UP
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
4.5" O.D. PVC HOUSE SEWER
PIPING HAS BEEN INSTALLED.
OF PUMP STATION. ELECTRICAL INSPECTION SEAL IS
TO BE AFFIXED TO PUMP STATION CONTROL PANEL.
THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS
® -
NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME
ABSORPTION FIELD VENTING NOTE
ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR
_
GARBAGE GRINDERS.
ROOF FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE
THE PRESBY AES ABSORPTION FIELD REQUIRES HIGH AND LOW
INSTALLER ADVISED TO CONTACT DIG SAFELY NEW YORK PRIOR TO
VENT DETAIL
CONSTRUCTION.
VENTING, WITH THE LOW VENTING BEING PROVIDED BY MANIFOLD
PIPING THE ENDS OF THE PRESBY AES LATERALS AND
36'
CONNECTING TO A STAND PIPE, 3' MINIMUM ABOVE FINISHED
GEOTEXTILE
GRADE.
INLET
FIBER WRAP
THE HIGH VENTING IS PROVIDED THROUGH THE BUILDING'S MAIN
RANDOMLY
THROUGH -THE -ROOF PLUMBING VENT, BY PIPING ONE OF THE
26"
KNOCK -OUTS IN THE DISTRIBUTION BOX TO THE HOUSE SEWER
ORIENTED
ALRM
LINE. IT MUST BE VERIFIED THAT A THROUGH-7HE-ROOF VENT
FIBER MAT
STACK EXISTS WITHIN THE HOUSE AND THAT A TRAP IS NOT
ENVIRO-SEPTIC
INSTALLED IN THE MAIN HOUSE SEWER LINE.
18
PIPE
PUMP„ON
IF EITHER OF THESE RESTRIC77ONS EXIST, THEN A HIGH -VENT
PROVIDED,KNOCK-OUT
14"
IS PIPED VERTIC L STANDS PIPE WHICH ISO10 -FT HIGHER
PUMP OFF
THAN THE LOW VENT.
DUAL WALL — SEMI -POSITIVE
CORRUGATED HDPE 0 29.5" DISPLACEMENT TYPE
TANK PUMP
El ONE DHO71 GRINDER PUMP ASSEMBLY DETAIL
12" MIN.
a a COVER 2" MIN. DROP
MIN. SLOPE
BETWEEN INVERTS
2" 1/8" PER FOOT_
2" MIN.
IIOUID LEVEL OU11ET 4" PVC EFFLUENT SEWER
' I 116"18"MIN.
�
off¢
foo
• J
2X WIDTH
1000 GAL PRECAST CONCRETE SEPTIC TANK
SEPTIC TANK NOTES
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE
DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED
/ BAFFLE ---
PRECAST CONCRETE
DISTRIBUTION BOX
USE SPEED LEVELERS TO ASSURE -
ALL OUTLETS ARE AT EXACTLY
THE SAME ELEVATION
4" PVC SDR -35 SOLID HEADER 70 -
PERFORATED ABSORPTION BED PIPING,
1/8" PER FOOT MIN SLOPE
BY UTOPIA ENTERPRISES OR EQUIVALENT. SEPTIC TANK DETAIL
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. NTS
WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE A STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY
CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL
MUST BE TESTED BEFORE BACKFILLING.
PRODUCT INFORMATION OR THE NEAREST DEALER CONTACT PRESBY
ENVIRONMENTAL, INC. 143 AIRPORT ROAD, WHITEFIELD, NH 03598,
STABILIZATION ROAD FABRIC OVER SYSTEM 12" MIN. GRAVEL SUBBASE 2ABOVE STABILIZATION FABRIC
" MIN. BINDER COURSE FOR GRAVEL SURFACED AREAS, VENT, SEE DETAIL--/
SAND & 3' BEYOND EDGES OF SAND BELOW PAVEMENT ASPHALT PAVEMENT INSTALL 12" ITEM 2 OR 4 GRAVEL 3' MIN
IV 3' MIN. 16' BED WIDTH - --- 3' MIN. —
BELOW SYSTEM & BACKFILL W/FINE-MEDIUM SAND FILL
ABSORPTION FIELD SECTION - TRAFFIC RATED
NTS
Dig FSafely.
NeWFl York
® Call Before YOU Dig
0 Wait The Required Time
Ij Confirm Utility Response
El Respect The Marks
E] Dig With Care
800.962-7962
w .dlgsafelynewyork.com
IULI
! !LL G� 2015 k
1 L _
JCD - \5\
RECORD DRAWING
TAX MAP # 289.14-1-16 & 17
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL
ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.
PHONE 1-800-473-5298 WWW.PRESBYENVIRONMENTAL.COM
AFTER EXCAVATION OF ABSORPTION BED TO THE DEPTHS REQUIRED,
THE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND
RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH.
4"0 LOW VENT ATTACHED
TO VENT MANIFOLD
PLACEMENT OF SYSTEM SAND, PRESBY ENVIRO-SEPTIC® PIPE AND
SCREEN OPENING
FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED
TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN
3'
THE PIPE.
ELBOW LEVEL WITH TOP
MINIMUM OF 6" OF SYSTEM SAND, MEETING SPECIFIED GRADATION,
OF OFFSET ADAPTOR
REQUIRED AROUND CIRCUMFERENCE OF ADVANCED ENWRO-SEPTIC
PIPES. (SEE DESIGN AND INSTALLATION MANUAL FOR COMPLETE SAND
4" MIN. TOPSOIL
AND FILL SPECIFICATIONS.)
\ \\ \.
A/A/ THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING
STRAIGHT CONTINUOUS GRADES K1774OUT SAGS, HUMPS, SEPARATED
P ^ _
2,-4"-- /
JOINTS, OR OTHER UNSUITABLE CONDITIONS.
LEVEL
J ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND
'
DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
SLOPE
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER
s
OFFSET
PIPING HAS BEEN INSTALLED.
�
- ADAPTOR
THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS
® -
NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME
',IAND I
ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR
_
GARBAGE GRINDERS.
ROOF FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE
MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM.
INSTALLER ADVISED TO CONTACT DIG SAFELY NEW YORK PRIOR TO
VENT DETAIL
CONSTRUCTION.
NTS
STABILIZATION ROAD FABRIC OVER SYSTEM 12" MIN. GRAVEL SUBBASE 2ABOVE STABILIZATION FABRIC
" MIN. BINDER COURSE FOR GRAVEL SURFACED AREAS, VENT, SEE DETAIL--/
SAND & 3' BEYOND EDGES OF SAND BELOW PAVEMENT ASPHALT PAVEMENT INSTALL 12" ITEM 2 OR 4 GRAVEL 3' MIN
IV 3' MIN. 16' BED WIDTH - --- 3' MIN. —
BELOW SYSTEM & BACKFILL W/FINE-MEDIUM SAND FILL
ABSORPTION FIELD SECTION - TRAFFIC RATED
NTS
Dig FSafely.
NeWFl York
® Call Before YOU Dig
0 Wait The Required Time
Ij Confirm Utility Response
El Respect The Marks
E] Dig With Care
800.962-7962
w .dlgsafelynewyork.com
IULI
! !LL G� 2015 k
1 L _
JCD - \5\
RECORD DRAWING
TAX MAP # 289.14-1-16 & 17
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL
ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.