Loading...
2015-035 4111A.. TOWN OF QUEENSBURY c4co 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 n Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20150035 Date Issued: Thursday, April 09, 2015 This is to certify that work requested to be done as shown by Permit Number P20150035 has been completed. Location: 677 GLEN St Tax Map Number: 523400-302-010-0001-007-000-0000 Owner: GLEN ST LLC Applicant: F.H. ALEXANDER, INC. This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property /� dlit owner of the responsibility for compliance with Site Plan, Variance, or /d other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWOF QUEENSBURY illaki, ktpa 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150035NApplication Number: A20150035 Tax Map No: 523400-302-010-0001-007-000-0000 Permission is hereby granted to: F.H. ALEXANDER, INC. For property located at: 677 GLEN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GLEN ST LLC Commercial Alteration $66,427.00 PRICE CHOPPER SUPERMARKET Total Value 501 DUANESBURG Rd $66,427.00 SCHENECTADY,NY 12306 Contractor or Builder's Name /Address Electrical Inspection Agency F.H. ALEXANDER, INC. BRIAN FLATT BFLATT(a,CNYMAIL.C OM 313 USHERS Rd BALLSTON LAKE NY 12019-0000 Plans&Specifications 2015-035 pharmacy alterations only 264 sq. ft. $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, March 04,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbre the ex,' .tionq date. rq Dated at the Town f u �, 1 �f W, '' ay March 04,2015 rimaikpX SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only / i2 11I15- Received ` �� lei DATE 1 Tax Map ID .,2,/6-/- TAX MAP ID ?i"l�'U 3ioZ- 010 -0001 ._ Permit No. 0/ 'Lt3�. 00100c - Permit Fee ZONING Lr © E te;ge,a HISTORIC SITE Yes $ No Subdivisio , FEB242015 -SUBDIVISION NAME Lot=-# „ TOWN OF QUEENSBURY TOWN Ba RESOLUTION 8 -2013: $850 RECREATION FEE FOR NEW DWELLING"UNITS,INCLUDING SINGLE:FAMILY DWELLINGS,DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED & MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. APPLICANT /1C1,..a)c,Are-10 kr - s N v OWNER �L�� ��+ t -L (ea-v.-v:7 Citft, AD °DREi'5 t YktevL i \ ADDRESS 5-01 1'/qf u-5t� Y-e I zU, -u-(0\A- c:n•-c•-1 A-NJ 123 C .__PHONE/E-MAIL -0 7 _N2,APHONE/E-MAIL t t_.ci.N\ CONTRACTOR �+•( Pct k4- iN.612.- 7 COST OF CONSTRUCTION(ESTIMATED): $ ADDRESS: 3 t'-, BUILDING ADDRESS: 0.1 tAPf' Frt�—��tS�1 �?�r-ems�1CSN tL-r✓ i Atm( /2Ut PHONE/E-MAIL.X577.—Otr2`11 • ZAN.V.W i~'h :`i 7D wP- k CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: '-'17)An. PHON '8"11-C '7 TYPE OF CONSTRUCTION A-CV -m,v Check all that apply Please indicate measurements as required below New Addition Alteration 1St floor sq. ft. 2nd floor sq.ft. Total sq.ft. Height Single Family Two-Family Multi-Family (#of units ) Townhouse Business Office Retail-Mercantile , — Factory- Industrial Attached Garage (#of ) Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business pa.,t.,e- &toPpc�12._ Proposed use of building or addition Source of heat(circle one) eg4 Oil Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? _ Site Information a. Dimensions or acreage of lot b. Is this a corner lot? c. Will the grade be changed as a result of construction Yes No d. Public water or Private well e. Sewer or Private Septic System �, Value of all work to be performed(labor or materials) $ L (�tp� �,c' DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed,subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: —1-440 DATE 2J244 l- c SIGNATURE: . DATE -7.� FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 . Town of Queensbury Building&Code Enforcement Office-No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: Pv\ Gno•c Inspected on: 1-ct Location: (Qc'c E Az r �f Y Arrive: Permit No.: Inspector's Initials: Algfiik • COMMENTS Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 inch Platform I Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch—38 inch/Step Risers 7"I Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch w/Lever Handles/Panic Hardware, if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve, Heat Trap I Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%> 1000 sq.ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification, if req. c As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Yj Water Fountain or Cooler /O Building Access All Sides by 20'/Drivable Surface 20'wide Special Inspections/Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O Okay To Issue C/C Commercial Final Inspection_11 27 12 G RX Date/Time 05/18/2015 08:00 15182731202 P.002 May. 18. 2015 8:02AM MDIA No. 5016 P. 2/14 �ti•V:; y :;:a. Q�:�C�:j���S��•\,•r��..�C`�•��:!�v.�,;aya` .,�/;^�:,�•�•,� �"�i�•�ic"/'��:7k.:A.Tw.vzz-4.::..i. .... ,l''JT- :..z/S4S,.%S..: `gin v:;�JiJ ✓ i�J':' /Z\::isze `;J ffei, `v :--Y<���� L"474.� ✓` j&Vs::- `W': ✓- ;.A.V.:'•i�=: t.:;<$.i;,•i�;;Vg.:•t:. gig., MIDDLE DEPARTMENT INSPECTION AGENCY, INC. �•? .`.9 `t� ty that the electrical wiring to the electrical equipment listed below has been examined and is approved as `., %`.3 being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date c��� (ttaj noted below and is issued subject to the following conditions. • (� • i Owner' Price Chopper Date: �� �) PP 04/01/2015 eV 0 Occu ant: �"� �� p Same Location: Upper Glen St 's) (`•) Occupancy Queensbury, Warren Co. NY 4 �� Non- Residential �N Applicant 6�' Sheft Electric � � �} 2451 Hermance Rd •f`fi� �') Galway, NY 12074 • rA. j <<:S C Joseph A.Holmes r No. 141489166155EL • Equipment � F`5 X4'.3-Switches;4-Fixtures;2-2000 KW Electric Heaters • t1) :,,,g s'''0 • l ((y4� This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use.occupancy and C$ above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership 1k' ? (rci inspection. No warranty is expressed or implied as to the mechanical safety.effi. of the property Indicated above, this certificate shalt be immediately null and void. (j 'ctiiyi ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes Invalid based upon the above conditions, f; aV be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department 51 system to which this certificate applies be altered in any way,including but not limit- Inspection Agency.Inc- An application for inspection must be submitted to Middle fgti 1� ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc.to initiate the inspection and revalidation (j.5 (�1 , any of the components installed as of the above noted date,this certificate shall be r (.� process. A fee will be charged far this service, <<?� (:•f;0::4h'.:a:.e.leg : =:���S3a 'c:�:�: �'`f;�•rv�%MV:4�i 0v0: {t 4 .n?.��:;c��r.J:ti.%';�55.•i 'i'.i-". :Sgei^��:.v.;;Atvi�t•i4:.�•ri-,•s••`=•-,1"' !.?�x.� .�:vJ;�1i�✓.�'L<v.�-v's�!t:� �'v%V:ms's ?�lha;�c��A `.`-'�.?n:::�J:J tic y :'i y ii. ei,"-•,;. r: .r J ✓ ,iiv 1r 4035 Town of Queensbury Building&Code Enforcement "ueS Office No. (518)761-8256 Commercial Final Inspection Report 10 -l Z__ Inspection request received: 5\,G' Name: "Ci){ anc Inspected on: .' \-5‘ 2-C'lc=' Location: (2-1-`1-Gty\ Sr. Arrive: i1 a.m.l p.m. Permit No.: Inspector's Initials: (0%— • COMMENTS Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete tC).a'1► Exterior Finish I Grade Complete 6"in 10'or Equivalent Interior 1 Exterior Guardrails 42 inch Platform/Decks 0Z— Interior I Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch–38 inch/Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch w/Lever Handles/Panic Hardware, if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap I Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%>1000 sq.ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp/Handrails Continuous/12 inch Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded g„�, e4 Site Plan I Variance required Final Survey, New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'I Drivable Surface 20'wide Special Inspections I Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O r/ Okay To Issue C/C Commercial Final Inspection_11 27 12 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Framing I Firestopping Inspection Report Inspection request receiveg: 51'2-(42t Name: QC, VY 1 Ce ey Inspected on: 'Z- 20�� Location: 10E14 tel►' , Arrive: /1/• -° a.m.)p.m. c � ' Permit No.: V� �JJ Inspector's Initials: i� TYPE OF STRUCTURE: ' Y N N/A COMMENTS: (-Framing Attic Access 22"x 30"minimum pp ro Jack Studs/Headers Truss Siecification Provided rac• Bridgin. Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w)16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall -9V Fire separation 1,2,3 hour � �� Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side IA inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing / Firestopping Inspection Reporticv Town of Queensbury Building&Code Enforcement Office No. (518)761-8256 8-I 0 Rough Plumbing I Insulation Inspection Report Inspection reques eceived: Il?-4l3 j Name: Y �('c On° V Inspected on: 3I 24 Location: Arrive: C „tm •.m. Permit No.: 15– O 3 3 Inspector's Initials: Type of Structure: COMMENTS Y NA Plumbing under slab C\c—, "' Q 2' Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place -' \ – ` kj 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/Insulation Inspection Report Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 0 — --itio/L-. Framing 1 Firestopping Inspection Report Inspection request r ved: 3t 1 S s Name: �l Le s-->/ Inspected on: \Zgrl ,'a 3 1 6 i S Location: 1 Arrive: - �Ari�� .m. Permit No.: c`,2C 13 —03:3 Inspector's Initials: / _� , TYPE OF STRUCTURE: pl rn��� �-� --, v N NIA COMMENTS: rami Attic Access 22"x 30"minimum Jack Studs I HeadersZ- '2---' Truss Specification Provided _ ��� Bracing/Bridging 37& Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls , Metal Strapping for Notches Top Plate 1 %(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side''%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off, if required Framing / Firestopping Inspection Report