Loading...
2015-046 TOWN OF QUEENSBURY Fors 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 ��� Q rY Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20150046 Date Issued: Friday, May 22, 2015 This is to certify that work requested to be done as shown by Permit Number P20150046 has been completed. Location: 607 AVIATION Rd Tax Map Number: 523400-302-006-0001-041-000-0000 Owner: DONNA E BALTIS, ESTATE OF Applicant: STARBUCKS - DANIEL BRENNAN This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or , I other issues and conditions as a result of approvals by the Planning Board Direc . ir ' ing co, "'f;`ment or Zoning Board of Appeals. TOWN OF QUEENSBURY ` 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 3,7 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150046 Application Number: A20150046 Tax Map No: 523400-302-006-0001-041-000-0000 Permission is hereby granted to: STARBUCKS - DANIEL BRENNAN For property located at: 607 AVIATION Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DONNA E BALTIS, ESTATE OF C/O PETER BALTIS Commercial Alteration $80,000.00 141 SWIFT Rd Total Value $80,000.00 VOORHEESVILLE,NY 12186-0000 Contractor or Builder's Name /Address Electrical Inspection Agency CHOICE TRADITIONS. INC. NY 12804-0000 Plans&Specifications 2015-046 Starbucks Coffee Commerical Interior Alt. 2999 sq. ft. $599.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,April 07,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To n of ens e , pril 07,2015 SIGNED BY + for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only DATE MARCH 03, 2015Received EI Tax Map TAX MAP ID 302.6-1-41 - Permit N it: Permit 6 -1 .4.61Prffir ZONING C-1 — fhAti 0 5 t ec Feel Site Plan HISTORIC SITE Yes X No TOWN OF QUE:..§.B1*.1440n# BUILDING & ;ODES I SUBDIVISION NAME Lot# TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS, INCLUDING SINGLE FAMILY DWELLINGS, DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED&MODULAR HOMES, BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. APPLICANT STARBUCKS - DANIEL BRENNAN OWNER PETER BALTIS ADDRESS 50 HOLT ROAD ADDRESS 141 SWIFT ROAD ANDOVER MA 01810 VOORHEESVILLE, NY 12186 PHONE/E-MAIL 603-505-5633 - PHONE/E-MAIL (518) 475-0088 danbrennan07@comcast.net CONTRACTOR Choice Traditions. Inc COST OF CONSTRUCTION(ESTIMATED): $ 80 K ADDRESS: 1126 Industrial Parkway, Unit 5 BUILDING ADDRESS: Starbucks Cofee -607 Aviation Rd, Brunswick, OH 44212 Queensbury, NY 12804 PHONE/E-MAIL JIM SANTEE -(330) 441-1198 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: DANIEL BRENNAN PHONE603-505-5633 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below New Addition Alteration 1st floor sq. ft. 2nd floor sq.ft. Total sq. ft. Height Single Family Two-Family Multi-Family (#of units ) Townhouse Business Office Retail - Mercantile 2,999 SF Factory- Industrial Attached Garage (#of ) Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business STARBUCKS COFFEE iProposed use of building or additionEXISTING TO REMAIN Source of heat (circle one) CGas Oil Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? NO Are there easements on the property? NA Site Information NA a. Dimensions or acreage of lot NA b. Is this a corner lot? NA c. Will the grade be changed as a result of construction Yes X No d. Public water or Private well PUBLIC e. Sewer or Private Septic System PUBLIC Value of all work to be performed (labor or materials) $ 80 K DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: DANIEL BRENNAN DATE 03-03-15 SIGNATURE: a', f� DATE 03-03-15 FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 Ilaz 42/ 3;49' /• ....._. Inspection Form Town of Queensbury Fire Marshal Periodic Inspection Date: //5TimeJ 742 Bay Road,Queensbury NY 12804 o e-Inspection 518 761 8206/518 761 8205 CO Inspection Permit#: /6 �✓ Fire Marshals Representative " ' n����� _ Mi almer Business Name: �C. 67 Location: LAK Stillman Contact: /V Sic,< ,-J�✓�/G 7131/' Type of Inspection N/A Yes No EXITS: Exit Access FC 1014&FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign: Normal FC 1011 &FC1029 Sign: backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 ///:, Secondary Aisle Width FC 1025&FC1029.11 ✓ FIRE EXTINGUISHER: Hung FC 906 Inspection of extinguisher FC 906 EVAC Plan FC 404.2 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: Interior FC 1006.3&FC1029.8 Exterior FC 1006.3 Clearance to Electrical FC 605.3 Electric Wiring Enclosed/Labeled FC 605.3.1 Combustibles in Equipment Rooms FC315.2.3 F.D.Signage- FC 510 ��` No Smoking Signs FC 310.3 , =M 0 �'� Storage FC 315.2 5.2 Compressed Gas FC 3003 .I Vehicle Impact Protection FC 312.1 / Ii ,_ Interior Finishes FC 803-804 ✓ Smoke Detectors FC 907 ../1 V CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) ..„..../9 Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATELY Vacant Buildings FC 311 _ - ' Emergency Disconnect FC 2203.2 `/ 21 DAYS SYSTEMS: FC 901.6 Imp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual ,/ FIRE ALARM Annual '7//y / DATE: OK NC HVAC Shutdown / Sprinkler System Annual 1 Sprinkler FDC /j Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection Town of Queensbury Building&Code Enforcement Office No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: 1`—( rER coc. V r Inspected on: —at —1 Location: _ Arrive: .C Permit No.: F " O kLQ Inspector's Initials: COMMENTS C c-x- c—\' ‘cQ-kc vtaKi7..) act- Y N NA Chimney/"B"Vent I Direct Vent Location Plumbing Vent Through Roof 6"I Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 inch Platform/Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch—38 inch/Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch wlLever Handles/Panic Hardware,if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade , Floor Bathroom Watertight/Other Floors Okay Relief Valve, Heat Trap 1 Water Temperature 110 Degrees Maximum447 Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%> 1000 sq.ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame kZ/ Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed • Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors 17/ Handicapped Bath/Parking Lot Signage /4.9. Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch, Checkout 36 inch a Handicapped Ramp/Handrails Continuous/12 inch Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded (� , Site Plan/Variance required �( Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/Driv Surface 21'w'i Special Inspections/Engineer) rc r h- itect Ap. Okay To Issue Temporary orPermanen • V Okay To Issue C/C Commercial Final Inspection_11 27 12 CALLISON A N A R C A D I S COMPANY CITY COMMENTS - REVISION # 1 04/03/15 To: Town of Queensbury,Building Department: John O'Brien FILE COPY From: Leo Estrada 2001 Bryan Street,Suite 3900 Dallas,TX 75206 Re: Starbucks—607 Aviation Drive TOWN OF QUEENSBURY Callison Project#:213534.63 BUILDING DEPARTMENT Based on our limited examination,compliance City Comments Revision with our comments shall not be construed as indicating the plans and specifications are in To Whom It May Concern: full compliance with the Building Codes of New York State. The following responses are for the comments received: 1. Comment: Please add to plans a 20"x 30"access panel for behind the back bar plumbing wall. Response: G-000: Cover Sheet a. Added sheet 1-2103:Interior Elevations and I-2104: Interior Perspectives to Sheet Index. G-0002: Scope of Work a. Added sheet note#66 to sheet: "New 20"x30"wall access panel at back bar plumbing wall"and added to plan. b. Relocated existing 3-comp sink,sanitizer and ice machine in Back of House to make room for access panel. c. Added sheet note#70 to sheet:"Relocated existing 3-comp sink and sanitizer"and added to plan. d. Added sheet note#71 to sheet: "Relocated existing ice machine and bin"and called out on plan. e. Added sheet note#71 to sheet: "Relocated existing pastry rack"and called out on plan. G-0003:Food Service Plan a. Relocated existing 3-comp sink,sanitizer and ice machine to make room for new • plumbing wall access panel in Back of House. G-0004:Egress Plan a. Relocated existing 3-comp sink,sanitizer and ice machine to make room for new plumbing wall access panel in Back of House. 2001 BRYAN STREET, SUITE 3900 DALLAS, TEXAS 75201 T 214 446 0950 F 214 446 0951 www.callison.com Starbucks—607 Aviation Drive,Callison Project#:213534.63 City Comments-Revision 1 04/03/15 • Page 2 I-1101:Demolition Floor Plan a. Relocated existing 3-comp sink, sanitizer and ice machine to make room for new plumbing wall access panel in Back of House. b. Added sheet note"WW"to sheet: "Existing 3-comp sink to remain and be relocated"and called out on plan. c. Added sheet note"XX"to sheet: "Existing ice machine and bin to remain and be relocated"and called out on plan. d. Added sheet note"YY"to sheet: "Existing pastry rack to remain and be relocated" and called out on plan. I-1103:Interior Floor Plan&Door Schedule a. Dimensioned new wall access panel on plan. b. Added sheet note#8 to sheet:"20"x30"access panel for Back of House plumbing wall"and added note to sheet. I-1104:Penetration Plan a. Relocated existing 3-comp sink,sanitizer and ice machine to make room for new plumbing wall access panel in Back of House. b. Added new floor sink at relocated 3-comp sink.Called out with sheet note#3 and floor sink detail. c. Added sheet note#10 for existing floor sink to left of ice machine to be reused. 1-1109:Floor Finish Plan a. Relocated existing 3-comp sink, sanitizer and ice machine to make room for new plumbing wall access panel in Back of House. b. Called out new floor sink at relocated 3-comp sink with sheet note#1. c. Called out existing floor sink to be used for ice machine with sheet note#7. I-1111: Wall Finish Plan a. Added interior elevation tag 1/1-2103 to plan to show location of new interior elevation added to set identifying location of access panel. 1-2103: Interior Elevations a. Added sheet 1-2103:Interior Elevations to set. b. Added interior elevation 1/1-2103 to set showing size and location of new access panel. I-2104: Interior Perspectives a. Changed sheet number of Interior Perspectives sheet to I-2104 to add new I-2103: Interior Elevations sheet. 2. Comment: Please add to plan an 18"vertical grab bar in each restroom as per ADA requirements. Response: G-0002: Scope of Work a. Added sheet note#67 to sheet: "New 18"vertical grab bar in restrooms". . Starbucks—607 Aviation Drive,Callison Project#:213534.63 City Comments-Revision 1 04/03/15 . ' Page 3 b. Added sheet note to plan in both Restrooms A and B. I-1105:FF and E Plan a. Added sheet note#10 to sheet: "New 18"vertical grab bar". b. Added sheet notes#10 to plan in Restrooms A and B. 1-1106:FF and E Schedules a. Added Design ID Number 10769(18"vertical grab bar)to Specialty Equipment Schedule"E"for G.C.to order. I-4102:Enlarged Restroom Plan and Elevations a. Added 18"vertical grab bar in Restrooms A and B shown in 1/1-4102. b. Tagged and dimensioned grab bar in all applicable elevation views,2/1-4102 through 9/14102. I-6001: Schedules b. Added Design ID Number 10769(18"vertical grab bar)to Specialty Equipment Schedule"E"for G.C.to order. Sincerely, Leo Estrada, Project Manager Enclosure c: Starbucks: Michelle Matanich Rispoli Callison: Billy Plummer M mo-subject-author-date created/Original sent via: Mail Courier Express Service Fax Hand Delivered Other,Copies sent via: Mail Fax Courier Express Service Other Various r