Loading...
RC-000127-2015 C) N � �a dd rr �� Fa tn 00 00 Qj � w Q p O Z to O o 0 o p o ti a� O U z v C3 y K G -p V1 a1 Nen N i. U u m w O Q H pm yU s p O y i o G Z U adi O � cUi cUi v fu ncc ca 0 R. F F ►] O E- v� N iJ, �: ta, > Li v TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000127-2015 bf 2d 4 r�> • � Tax Map No: 266.3-1-73.6 Permission is hereby granted to: Chris Patten REVISED For property located at: 10 RIDGEWOOD CT In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvoe of Construction Owner Name: Chris Patten Single Family-New $100,000.00 Owner Address: 7 Jackson RD Total Value 5100,000.00 South Glens Falls,NY 12803 Contractor or Builders Name/Address Electrical Inspection Agency Chris Patten 7 Jackson RD South Glens Falls,NY 12803 Plans&Specifications Ridgewood Court Subdivision,Lot 6 SFD 1494 s.f. 2 car attached garage 400 s.f. Fireplace PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,July 29,2016 (if a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of rens t c s ay 2015 SIGNED BY: /// for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 41Ia T742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150324 Application Number: A20150324 Tax Map No: 523400-266-003-0001-073-006-0000 Permission is hereby granted to: PATTEN PROPERTY DEV. LLC For property located at: 10 RIDGEWOOD Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PATTEN PROPERTY DEV. LLC Fireplace 7 JACKSON Rd Garage-2 Cars Attached SOUTH GLENS FALLS NY 12803-o Single Family Dwelling $100,000.00 Total Value $100,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications BP 2015-328 Lot 6, House No. 10 Ridgewood Court Ridge Road Subdivision Single-Family Dwelling 1,494 sq. ft. with 2-car attached garage (400 sq. ft.) and fireplace $358.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,July 29,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town Que sbu / 4„, , ly 29,2015 SIGNED BY I for the Town of Queensbury. Director of Building&Code Enforcement l Rip 11,ide) ,4 • PRINCIPAL STRUCTURE APPLICATION Office Use Only Received Date: '7 - 20 1 STax Map ID 2.. -7,3 l-13. _ Permit No. Tax Map ID � (o G � �- � - ]3 ,(o __ - ' it Fee . OiS- 3.a. Zone S R ` 1 A e Fee Historic Site Yes L----No Site Plan# Subdivision Name 'Rt� p ) [�ffv, Lot# GSubdivision# TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS - SINGLE FAMILY, DUPLEXES/TWO-FAMILY, MULTIPLE FAMILY, APARTMENTS, CONDOMINIMUMS, TOWNHOUSES,AND/OR MANUFACTURED&MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. Applicant CA�f I S 1J Te Owner �C4k Q(114/ � IO'I LL1LJ Lu_ Address TaKSC Address 6mi I�,McJUV /28103 Phone/E-mail p U l 0 t 6(,.b' Phone/E-mail Contact Person for Building&Codes Compliance: C 1111 -PC,-4 1 '\ Phone 7/6-Y6 6-Y6 S I, S TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1St floor sf 2nd floor sf Total sf Height Single Family (2 L `1 Two-Family Z T Multi-Family (#of units ) /� Townhouse .22_N- Townhouse Business Office Chris Patten BP 2015-324 Retail -Mercantile Lot 6, House No. 10 Ridgewood Court SFD, 2-car att. garage and fireplace Factory- Industrial Attached Garage tLz ( rD (1, 2, 3, 4+) , (OL S i Other Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 If commercial or industrial please indicate of business ff Proposed use of building or addition CI()elk I�iw� I�,ec1 e"--h'o.,i Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys 92S Are there structures not shown on plot plan? iv 0 Are there easements on the property? Site Information a. Dimensions or acreage of lot I ,�ZSp b. Is this a corner lot? c. Will the grade be changed as a result of construction Yes V--No d. Public water or Private well ?n vo e. Sewer or Private Septic System P A-t C Value of all work to be performed (labor or materials) $ )QO,6irt. �1 ,��♦� 60-21/ DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application,plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: C/\ ç '/ r ' DATE: 7 /zo/ i5 SIGNATURE: ✓ ► DATE: 7( Ji For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 • SEPTIC DISPOSAL APPLICATION Office Use Only Received -7 DATE: 1 0— �S Tax Map ID 3a TAX MAP ID: Z69‘,3 (—73 r� Permit No. C(,s- Permit Fee ZONE: SR I —� APPLICANT C� - I S PHONE/E-MAIL -lit, -tit,S ci ADDRESS `) 3 -rd Glevt& Fodt1 A)/ l'2813) INSTALLER/ ?GL i. 4 '(4-1 O(wt a'► PHONE/E-MAIL Pa- e"W1@—)Y ` ' °D� BUILDER OWNER L ADDRESS Lo} �p Rt) yr' — (� CONTACT PE SON FOR BUILDING&CODE COMPLIANCE: C4- - ' ►!V � '� PHONE/E-MAIL RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes 9'No 1981-1991 Spa or Hot Tub installed _Yes D4 No 1992-Present ' t O L+ 5 PARCEL INFORMATION Topography ✓ Flat rolling Steep slope %Slope Soil Nature land Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: NA Domestic Water Supply Municipal VWell(if well,water supply from any septic system absorption is/00}ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size lap gallons(min. size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length /(.)6 ft.;Each Trench el 0 Seepage Pit with#3 stone How many: ; Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: (''S DATE: 2 d—15 SIGNATURE: DATE: `7— ?,o— 15 Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 \, July 22, 2015 D Job#49384 Chris Patten Patten Property Development JUL 2 3 2015 7 Jackson Road South Glens Falls,NY 12803 TOWN OrQUEENSE3URY BUILDING &CODES RE: Septic System Lot 6 Ridgewood Court Subdivision, Ridge Road, Queensbury,NY Dear Mr. Patten: At your request we have performed a percolation test on Lot #6 of the Ridgewood Court Subdivision. The test was performed in the location you chose for the proposed septic system. Percolation test Test run at a depth of 24" in a 30" deep hole Stabilized percolation rate— 1" in 4 minutes 20 seconds The percolation test result is consistent with the percolation test results provided on the approved subdivision drawings. As discussed the septic system size and layout should follow the standard septic system details provided on the approved subdivision plans. The proposed 3 bedroom house will require a 1,000 gallon septic tank and a minimum of 138 lineal feet of absorption trench. Please call me if you have any questions. Sincerely, Thomas W. Nace, P.E. Chris Patten BP 2015-324 Lot 6, House No. 10 Ridgewood Court SFD, 2-car att. garage and fireplace Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: ` 2 o - I S Tax Map ID TAX MAP ID: �(Q(� ,3 - �j, �o ;:: :e if JUL 42 2 5 ZONE: r A- OWNER CAN`,I S t oc\A-44ek PHONE/E-MAIL ADDRESS I "TaGftsc IU [�,�`C4e4 F Ls INSTALLER/ "D 4 W( `r rof — PHONE/E-MAIL Pofi-Q,,1 3'14 r, BUILDER ---(— 1�rt lac t_ Go z. /-,- _1' G 96S-11 eJ► .I % c c��-'^ CONTACT PERSON FOR BUILDING&CODE COMPLIANCE:/ r1$ PHONE/E-MAIL q yt Sy BUILDING ADDRESS Lv4- ROOM OF INSTALL: (—rAvvvi �l,/ PLANNED INSTALL DATE: - Zv - I S FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* r / NOTE: ` y MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: rn 9 ; Model #: " 9 CO DU Listed by: ,,-i lace_G ci4y Number. CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ; Model #: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: hr1S Pte. (\ DATE: 7/2.o/13 SIGNATURE: U DATE: 2-0/5 Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: "7 .]D l5 Applicant Name: CAN is R.. -fes Telephone No.: -) 61(p —4 (o S1-1 Address to be Inspected Loi( c o �a.,WJ n,+l Return Address: Tvc.kso ti. C.CA1etig ((S ,f V!"/ 7V3 Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( 12" ( 15" ( 18" ( 24" ( 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 -RA Foundation Inspection Report pass ve . Office No. (518)761-8256 Date Inspection request received: 6174 12.Q,1S Queensbury Building&Code Enforcement Arrive: am/pm Depart:/ " , .m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials NAME: A�"-YL—T PERMIT#: 2013 LOCATION: 10 e_koc —vsic .4 INSPECT ON: el'2-i 12Q.lS TYPE OF STRUCTURE: S' Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 -1—t-r-LA Rough Plumbing I Insulation Inspection Report Inspection request received ? 2a\2p‘S Name V \ Inspected on 81 - 1 2_0 k 3 Location ID V-kd, e c ood c*- Arrive ' am/pm Permit No. '2.015-32 Inspector's Initials .d 1A--. Type of Structure 5 ---------., COMMENTS Y N NA Plumbing under slab Rough Plumbing /Nail Plates jeg) <5b,t -2 1 1-46 Plumbing Vent/Vents in Place 1 Vz inch minimum Drain Size (/-- Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/ Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape Blower Door Test Air Saling ft). _31 )Wty;KI 71/41L)ALI L-4.:_yv 'lir 4-1.3 (41...)-g ai)/gA'L------" -\-7`.*9 , vfc.....R1--1„ ........ ,A cd}e..... ......._, 1 1 1 1 Town of Queensbury Building & Code Enforcement Office No. (518)761-8256 t -1® Foundation Inspection Report OkY,A(1) Office No. (518) 761-8256 Date Inspection request received: 61 1, 12-1J Queensbury Building&Code Enforcement Arrive: am/pm Depart \ am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: !> PERMIT#: 2015-'321- G LOCATION: I© e,1 e Nn O C . INSPECT ON: 1 X.,15 TYPE OF STRUCTURE: ST—ti Comments N N/A Footings 04P J7 (0 - Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour / Reinforcement in Place / Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 '.1. BoundarymformationshownhereonperMap Ref. 1. 2 North 0nenta&onandbearingbaseperMapRef 1. 3. Warren County taxparcel266.3-1-73.6 4. Thelocatton ofundergmunai mprovements or encroachments if any exist or as shown hereon are not certified There may be other underground utilities, the existence of which are unknown. Size and location ofaB underground utilitiesmust he verified by theappmprfate authorities The UndergmundFacilitiesPmtective Organization mustbenobfied prior to conducting test borings, excavation and consbuction. 5. This survey wasprepared without the henebtofan up to date abstract of title 6 Reproduction or copying of this document may he a violation ofcopyrlghtlaw unless permission of the author and/ or copw*tholderis obtained. 7 A copy of this document withouta proper application of the surveyor's embossed seal should be assumed to be an unauthorized copy DEEDRBFERENCB! 1. Conveyance to Robert Wall by deed filed in the Warren County Clerks Office on Ociober3, 2006in Book 3070 of Deeds atpage 296 MAPRF.FF.RENCE L Map entitled RIDGEWOODHOMES RIDGEROAD 5L7BDIVI5I0N'prepared by PanDusen and Steves Land Surveyors; dated Mays, 2005, lastzevi ed July 11, 2005, filed in the Warren County Clerks Office on Aprils, 2007 asmapnumber G5 RD - �"\ RIDGEWOOD COURT N I Lands Now or Formerly of Wall Book 3070 Page 296 266.3-1-73.7 SEPTIC :)LOT DI ens I HAVE SEEN OR OBSERVED ALL OBJECTS SUCH AS HOUSES, WELLS, TREES, FENCES, ETC SHOWN ON THIS DOCUMENT I HAVE PERSONALLY D A�DISANCES ORSTHONTHISTHISDIAGRAM SIGNATUR REE Lands Now or Formerly of Curran Book 1315 Page 134 266.3-1-74 Proposed I Driveway I I ah /cis L=26.41' R=2500' Ch= 56055642E 25.20' 6 L=80.46' R=70 GYP ti1 � Ch= S55°IS'39'6 75.29' C0.01pased \ 16.0' Well I \ a Proposed b \ I � Concrete ti ` � ` I Foundation -- f-503, 16.58' 12.1 I I I I I I �pdcAProposea II I I I ti I I w H AREA =1.021 acres I ItA I I � I � I � I � I I L----------------------� once �siora rsEcoao/oemavnox oanrrta :. e xou oma. i.mo a.rpy, suc APIROVELtK,1ID DRAFnD: PM PROD. NO: 15 SCALE: I"a90' DAn:)/V/15 i 7 O N NV N M O Q r O •� (L -0' : m � N CU O IS Z �; d (�6 M O U (L = N L (.0 0 Z p LL U J U) Lands Now or Formerly of Wall Book 3070 Page 296 266.3-1-73.5 L ? u 2015 Map ofa Proposed Plot Plan ra„a9noworr�,atyot Robert Wall zvimoFQUS 'RuiZY WARR"CYIUNIY, AVi YORK N Darrah Land Surveying PLLC 15030-1 3764Narth StmmRmd Hadley, New Yorki2R, Phroi,,�(378f79B-4692 1` I0F1 PRO/IrZt 1,S'/30