Loading...
2015-359 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20150359 Date Issued: Monday, November 28, 2016 This is to certify that work requested to be done as shown by Permit Number P20150359 has been completed. Tax Map Number: 523400-308-014-0001-052-000-0000 Location: 183 PITCHER Rd Owner: FOREST PARK -- 65 GREGWOOD CIRCLE Applicant: FOREST PARK 21 & 23 BRIWOOD CIRCLE This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QQUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the �J4A property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 0,0 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150359 Application Number: A20150359 Tax Map No: 523400-308-014-0001-052-000-0000 Permission is hereby granted to: FOREST PARK 21 & 23 BRIWOOD CIRCLE For property located at: 183 PITCHER Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: FOREST PARK-- 65 GREGWOOD C Septic Alteration Residential 31200 NORTHWESTERN Hwy Total Value FARMINGTON HILLS MI 48834-00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2015-359 Residential Septic Alteration 21 & 23 Briwood Circle $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,August 13,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the ex iration date.) Dated at the Tow of Qu a sbu 4 T4/ ,, • ugust 13, 2015 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement SEPTIC DISPOSAL APPLI ." 117, (E, E Use Onl 1 ' 1e ved DATE: $ I I I S 2tC A"r 1 1 I �� i ap ID ' hwu "ermi` No. n- „uEENsBTAX MAP ID: 3t�`�S, I�� - I - J oZ Rl�ermi FeeZONE. TOBptGODE' - APPLICANT Oce -i- Vac ,)c_ m -1c, L.L L PHONE/E-MAILt ( a$, 7(.�5.-7-7 -7(p ADDRESS 1%3 9 i-+c he.c 1 . GY O ul-i3 'J U fLI ��r I D S()L L04- Off► '� D3 INSTALLER/ J PHONE/E-MAIL BUILDER r1 �i ong (sl )d3)"1x01 OWNER Ca1105 Q �' l ADDRESS L1 3b Q")- 5'O J�1-c - )c NN/ ►�c6a9 CONTACT PERSON FOR BUILDING&CODE COMPLIANCE': ���im 3 0- cd,t PHONE/E-MAIL CSI$, �3a- L-7 C"7 RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed _Yes _No 1981-1991 3 11 0 3 3 O Spa or Hot Tub installed _Yes _No 1992-Present 3 1 1 0 3 3 D PARCEL INFORMATION 0 Q Q aockxthe d pian n� Topography Flat rolling Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size I O0j') gallons(min. size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length 1.9C) ft.;Each Trench x 55 Q � � Seepage Pit with#3 stone How many: y ;Size JC m ,e5 Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: � . iQ ay) (� Y y1 DATE: YI I 1115-' SIGNATURE: ��'y,'„ i - , C� DATE: � Y� / • Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 Town of Queensbury Building &Code Enforcement Z — V 1 Office No. (518)761-8256 Septic Inspection Report Inspection request received: 2 '1//S Name: w4iec 1" 4! "�' 6L r'- H petted on: g, a C 4- Location: 3 r, wb U.C`C. Arrive: A,�m. p.m. Permit No.: i I , Inspector's Initials: �� C• • ents and/or dia•ram Soil Tyr6siaillace4-Glay r Type of Wat . Municipal/)Well Water Waterline separation distance 10 ft. "r' —^ Z— v3 ..uJ \o oO GAll1)1 Well separation distance ft. �� \ Other wells: ft. C2_5 Well Casing Length 50'+/- Y N_N/A [150'to well required if NO] �—`Ev_ \�t�V 'J. Absorption Field: Total length 2—Zo ft. Length of each trench AQ'tWft. Depth of trenches 71—Z'_ft. Size of Stone N,a _ aec._z4 Ltd Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank LA 11 ,t't tiO Tank to Distribution Box 4 '1 /c `,1/4 yo Distribution Box to Field/Pit L1 'k P\)(-- i--u ,R Q . 2^1-4 Opening Sealed: 2( N End Cap N Inlet/Outlet Pipes&Baffles _s2( N Manholes 12"or less below grade _ N [provide extension collar if Yes] N Location/Separations Foundation to tank ft. SEC - _L� � Foundation to absorption ft. �� �� Separation of Pits ft. gbit- Conforms as per Plot Plan _Y Engineer Report and As-Built Y N ETU Maintenance Contract provided Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: / Approved 1/ Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report �� 0 N F- lo 0 aa - DESIGN INFORMATION SOILS INFORMATION: DESIGN ELOW DESIGN PERC. REO'D LENGTFI OF PT - PERCOLATION TEST (LOCATIONS, SEE PLAN) �M DTP - DEEP TEST PIT TEST PERFORMED ON 6-05-15 WITH STONE INDUSTRIES AND NYSDOH 6 660 GAL/DAY 1-5 MPI 275°-25X 206° REPRESENTATIVE IN PROPOSED TREATMENT AREA. TRENCH SYSTEM WITH ADS HANCOR ARC 24 CHAMBERS TOTAL NUMBER OF LATERALS = 4 LENGTH OF EACH LATERAL = 55'—Oa TOTAL LENGTH OF LATERALS = 220' * PER NYSDOH APP. 75—A(FEB 3, 2010). A 20X REDUCTION IN TRENCH LENGTH IS ALLOWED WITH USE OF GRAVEL.LESS CHAMBERS WITH 1.6SF/FT OF BOTTOM AREA & VOLUME OF 7.5GAL/FT & OPEI SIDEWALLS. TABLE 6C OF NYSDOH 'GREEN' HANDBOOK. i O O I PARKING 4 LATERALS AT 55' EACH. ADS HANCOR ARC 24 CHAMBERS. SEE DETAILS. LOCATE WATER LINE AND MAINTAIN 10' HORIZONTAL SEPARATION TO SEPTIC. TYP. i AS—BUILT TIE—IN DIMENSIONS FT A B C D D—BOX L1 BEGIN L1 END L4 BEGIN L4 END DTP 10 (SEE SITE PLAN FOR LOCATION) 09-139 DARK SANDY TOPSOIL 89-27' LIGHT BROWN SAND 279-67' TAN/BROWN SAND NO GROUNDWATER OR MOTTLING NOTED PT #1 STABILIZED PERCOLATION RATE: 1:10 MPI PT J22 STABIUZED PERCOLATION RATE: 1:15 MPI PARKING I SITE INFORMATION: TOPOGRAPHY AT TREATMENT FIELD IS RELATIVELY LEVEL DWELLI!YG SUPPLIED WITH MUNICIPAL WATER. NO ACTIVE NEIGHBORING WELLS NOTED/VISIBLE WITHIN 100° OF TREATMENT AREA. NORTH M R 1 N C' 1. SEE NOTE SHEET. CALL ENGINEER TO CLARIFY ANY DESIGN DETAILS. 2, USE DIMENSIONS GIVEN: DO NOT SCALE DRAWINGS. 3• ALL PERMITTING/VARIANCES TO BE OBTAINED BY CONTRACTOR AND/OR PROPERTY OWNER. EXISTING FAILED. SEPTIC SYSTEM CONSISTS OF COMBINED LOTS I, 21,23,25,27,29&31 FLOWING INTO A 1500 GALLON SEPTIC TANK THEN TO A DRYWELL. PROPOSED PLAN IS TO PROVIDE EACH 3 BEDROOM LOT WITH SEPTIC__I?.I INDIVIDUAL 1000 GALLON SEPTIC TANKS AND A TREATMENT AREA DESIGNED ' FOR TWO LOTS WHICH EQUALS S BEDROOMS TOTAL B � HAVE SEEN QR O�3 S� � J�� ��(: 0 I�CrT� `�JCH AS HOUSES, kNELI ! r;l S I Ellt�c E 1"0. ,.'1GWN ON THIS DOCUlN _N I: I I-,,�Vr � EI�St . IAkLY S (l D THE DISTANCEtT ORTH G�!'f HlLv5� DD AG -�, NI. Irl, DATE 2 y 0 SIGNKTURE Lor INFORMATIoN rn TAX MAP #: 308.14-1-52 s� TOWN OF QUEENSRURY rmn EXISTING 3 g ° LOT X23 BEDROOM DWELLING W ,, J ° IeWI.I L1 NEW 9 000 OGALLO� oO�dCR�TE � •` � 3 i l\i��lk PROJECT — - — d NOT ' TANK WITH FILTE .SEEi'LWILS t • ter: " ' -VVYE SHED D -BOX 1 EXISTING 2 NEW 1000 GALLON CONCRETE LOT #21 BEDROOM TANK WITH FI TERISEE DETAILS. DWELLING —SOLID 4"0 SCH40 AT J" PER FOOT ACTUAL SEPTIC COMPONENT LAYOUT INSTALL AS SHALLOW AS POSSIBLE. TYPICAL. MAY VARY DUE TO BURIED UTILITIES. / INSTALLER TO LOCA-TE-TE—Ui�C�ERCaR�TJND IUTILITIES PRIOR TO CONSTRUCTION. & r 4� SEP11C SITE PLAN PLOT PLAN INFORMATION OBTAINED FROM WARREN COUNTY GIS m AND AS PURPORTED BY PROPERTY MANAGER. THIS DRAWING DOES NOT REPRESENT A LAND SURVEY AND MUST NOT BE CONSTRUED AS SUCH. �s� � 95®z� � oppss1®,�A� LOT SIZE: 48,9 ACRES APPROVAL STAMP / NOTES a AIPPHI )VI () TOWN OF QUA-F� BUILDING 0 Reviewed By. Oates PRo,IEcl: SEPTIC REPLACEMENT DESIGN / GRAVELLESS CHAMBER FOREST PARK — LOT #21 & #23 163 PITCHER ROAD, 9UEENSBURY, NY (TOWN OF QUEENSBURY) DRAWINGRKn ENGINEERING, P66C SITE PLAN 225 RUGGLES RD., SARATOGA SPRINGS, NY 518.581.3893 FILE NAME S1TF SUBMITTAL / REVISION ISSUED FOR REVIEW/APPRC SCALE APP'D. DATE DATE AL RKR a/S/15 REVISION C-001 ov �0 aiL SEE PLAN FOR NUMBER OF LATERAL LINES ONE CHAMBER LONGITUDINAL SECTION FROM SEPTIC TANK 4' DIA. SOLID PVC OUTLET — 2' MIN. —CLEAN SAND, PEA GRAVEL OR AGGREGATE (3/4' - 1 1/2') 1. PIPE JOINTS TO BE SEALED LIQUID TIGHT. 2. SPEED LEVELING DEVICES SHALL BE USED ON ALL OUTLET PIPES. 3. SEPTIC TANK TO D -BOX: 4' PVC OR SDR21, LIQUID TIGHT .HINTS, MIN. SLOPE 1/8' PER FOOT. 4. THE SLOPE OF OUTLET PIPES BETWEEN THE DISTRIBUTION BOX AND DISTRIBUTION LATERALS SHOULD BE SLOPED AT LEAST 1/32" PER FOOT AND CONSTRUCTED OF 4" PVC SCH. 40 OR SDR21 WITH LIQUID TIGHT JOINTS. 5. USE DOUBLE SIDED STICKING RUBBER BUTYL FOR DOSED SYSTEMS. NEW CONCRETE DISTRIBUTION BOX SCALE: NONE MOUND TOPSOIL FOR SETTLING. SEED AND COVER WITH STRAW. 6' 6°' TYP. 1 F— MIN. V_ ,1W, ADS - N O.7 —R 2 -- DUE TO GRADE CHANGE BURIAL DEPTH WILL VARY. INSTALL LATERAL END VENTS IF TOP OF CHAMBER >3' DEEP. �— PROPOSED GRADE, SLOPE TO DRAIN. SEED AND MULCH. INSTALL LEVEL. REMOVE nFRRIS. RAKE FLOOR & WALLS. GROUND WATER, BEDROCK OR IMPERMEABLE STRATA �JION 24" DIA — OUTLET PROVIDE EFFLUENT FILTER. SEE NOTES. FILTER (POLYLOK PL -1 22) NISHED GRADE '11ARaft, SEED & MULCH '�'WATERPROOF SEAL POLY RISER OUTLET CAULKED JOINT SANITARY TEE W/ EFFLUENT FILTER 3' MIN IF DESIGNED TO USE EXISTING SEPTIC YANK; P13MP OUT AND INSPECT EXISTING TANK. PROVIDE WRITTEN REPORT IO ENGINEER. 1. MINIMUM TANK CAPACITY AS FOLLOWS: — FOR 3 BEDROOMS OR LESS TANK SHALL BE 1,000 GALLONS, WITH 27 S.F. SURFACE AREA. — 4 BEDROOMS SHALL HAVE A 1,250 GALLON TANK WITH 34 S.F. SURFACE AREA — FOR EACH ADDITIONAL BEDROOM ADD 250 GALLONS & 7 S.F. SURFACE AREA. - FOR HOT TUR/SPA AND/OR GARBAGE GRINDER ADD 250 GALLONS TO TANK SIZE FOR EACH. 2. BUILDING TO SEPTIC TANK: 4' PVC SOH. 4O PIPE, LIQUID TIGHT JOINTS, MIN. SLOPE 1/4' PER FOOT. 3. SEPTIC TANK TO D -BOX OR . PUMP TANK:. 4� PVC SCH. 40 PIPE OR SDR21, LIQUID TIGHT JOINTS, MIN. SLOPE 1/�' PER FOOT. 4. SEPTIC TANK TO CONSTRUCTED PER NYSDOH GUIDUNES. FOR EACH MOBILE HOME UNIT PROVIDE NEW 1000 GAL CONCRETE SEPTIC TANK SCALE: NONE m ,A `-' - s- PROJECT NOTES• 1. SYSTEM DESIGNED IN ACCORDANCE NTH 2010 NYSDOH APPENDIX 75-A. SEE NYSDOH'S "APPENDIX 75-A, WASTEWATER TREATMENT STANDARDS INDIVIDUAL HOUSEHOLD SYSTEMS"& "NYSDOH — (GREEN) DESIGN HANDBOOK" FOR ADDITIONAL DESIGN AND INSTALLATION GUIDELINES. NO GUARANTEE ON SYSTEM PERFORMANCE OR LONGEVITY. 2. INFORMATION ON THESE DRAWINGS IS FOR SEPTIC SYSTEM DESIGN PURPOSES ONLY. 3. CONSTRUCTION SHALL BE AS SHOWN ON THESE DRAWINGS AND IN ACCORDANCE WITH ALL NYSDOH AND SYSTEM MANUFACTURER'S REQUIREMENTS. 4. ALL WORK MUST COMPLY WITH LOCAL, STATE & FEDERAL SAFETY REGULATIONS, (NYSDOH, OSHA, NYSDOT). PERMITTING REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 5. HEAVY EQUIPMENT SHALL BE KEPT AWAY FROM THE TREATMENT FIELD. NO VEHICLES ALLOWED ON TREATMENT FIELD. 5. SMEARED TREATMENT AREA FLOORS AND WALLS ARE f0 BE RAKED. 7. TREATMENT FIELD SHALT. BE GRADED TO SHED RAINFALL AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS. B. RECOMMENDA71ON: DOWNSLOPE OR SHALLOW WELLS SHOULD HAVE UV TREATMENT OR CHLORINATION AND FILTRATION SYSTEM INSTALLED. WELL WATER QUALITY SHOULD BE TESTED PERIODICALLY. 9. INSTALL EFFLUENT FILTER IN SEPTIC TANK, (POLY-LOK PL -122) WITH A RISER OR EQUAL. 10. GARBAGE GRINDERS AND WATER TREATMENT SYSTEM SHALL NOT ATTACH TO SEPTIC. NO SUMP PUMP DISCHARGE ALLOWED. LEAKING FIXTURES WILL CAUSE FAILURE OF SEPTIC SYSTEM. APPROVAL STAMP / NOTES 'TIC REPLACEMENT DESIGN / GRAVELLESS CHAMBER FOREST PAR LOT #21 & +423 183 PITCHER ROAD, QUEENSBURY, NY (TOWN OF QUEENSBURY) ENGINEERING, PLLC 225 RUGGLES RD., SARATOGA SPRINGS, NY 518.581.3893 FILE NAME SCALE t _ NO. T SUBMITTAL / REVISION PP'D. DATE DATE A ISSUED FOR REVIEWW/APPROVAL RKR 6/5/95 RAN DRAWING TITLE DETAILS DETAILS AS NOTED JUNE 2015 A C-100 If/ 4F 2