Loading...
RC-000321-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000321-2016 Date Issued: Tuesday, November 8, 2016 This is to certify that work requested to be done as shown by Permit Number RC-000321-2016 has been completed. Tax Map Number: 301.17-3-55 Location: 37 CAITLIN DR Owner: Kelaco,LLC Applicant: Collette Construction Inc. This structure may be occupied as a: Single-Family Dwelling 2400 s.f. Pointe West Subdivision,Lot 8 By Order of Town Board 2-car attached garage 580 sq. ft. TOWN OF QUEENSBURY 1-gas fireplace Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. ;`--- TOWN of QUEENSBURY 742 Bay Road, Queensbury,NY 12804-5904 (5 18)761-8201 Community Development - Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-000321-2016 Tax Map No: 301.17-3-55 Permission is hereby granted to: Collette Construction Inc. For property located at: 37 CAITLIN DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Kelaco, LLC Single Family-New $340,000.00 Owner Address: 35 Front ST Total Value $340,000.00 Lake George,NY 12845 Contractor or Builder's Name/Address Electrical Inspection Agency Collette Construction Inc. 38 Collette LN Hudson Falls,NY 12839 Plans&Specifications Single-Family Dwelling 2400 s.f. Pointe West Subdivision, Lot 8 2-car attached garage 580 sq. ft. 1- as fireplace $ 1,467.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday, May 27, 2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Towno ween ury; f/� AVede d 1,2016 SIGNED BY: ' 4 for the Town of Queensbury. Director of Building&Code Enforcement Date: � _�_- L Permit No. x Tax Map ID :�n - t� > J � Permit Fee Zone Historic? _Yes lNo Rec Fee i� Subdivision Name Lot# Site Plan# �,�;:�7ti �'t,;,-�•�' �--- Subdivision# Project Location 4,1- 3•I C�,7�,ti ��� rye��; ��'�r TOWN DD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes, but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Address }- 7y / e c Phone/Email _ -- tiTCS Ali ii d7" (G-//e '/V C ,.a: vc%i C• 1 —_. Applicant a C� le� �f�s 7'= MAI Address 'TO Cry%/r f/p GYu /Y Phone/Email I t Me)P �; d r! c:� 1�o.'� r Contractor i �'P Address ,ds' Phone/Email Contact Person for Building & Codes Compliance: p, _[,�%/„ �/ Phone TYPE OF CONSTRUCTION (Check all that apply New Addition Alteration 11 floor sf 2111 floor sf Total sf Height Single Family — Two-Family Multi-Family (# of units�) Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) ��0 Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition r A-z" Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances& Chimneys Are there structures not shown on plot plan? AJC Are there easements on the property? J 0 Site Information: a. Dimensions or acreage of lot /e/ AC&z b. Is this a corner lot? Yes _.,,/No c. Will the grade be changed as a result of construction Yes No /17,ti;aL� d. Public water or Private well(circle one) _u Private e. Sewer or Private Septic System(circle one) Sewer vat Value of all work to be performed(labor or materials) $ 3 51b DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed,I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: C.a A 4 DATE: $15-5-11C SIGNATURE: k' .. �5 � DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: S'l�� Tax Map ID TAX MAP ID: Permit No. ZONE: Pen-nit Fee OWNER e PHONE/E-MAIL ADDRESS INSTALLER/ PHONE I E-MAIL / BUILDER IAP/P � GG vC 7-W, CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: ((�� PHONE/E-MAIL e A BUILDING ADDRESS 3 C.c�l�Lln1 E�,Q ROOM OF INSTALL: /!r . PLANNED INSTALL DATE: u I 2 6 i g I FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* ✓ NOTE: FIREPLACE,MASONRY MANUFACTURER'S INSTALLATION MANUAL FURNACE GARAGE ONLY MUST BE AVAILABLE AT TIME OF INSPECTION If factory built provide manufacturer name: '16 ; Model#: � V Listed by: Number: CHIMNEY INFORMATION Masonry** (cheek one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL `TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ; Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: //e/7 DATE: SIGNATURE: DATE: ;f 5` Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 CHECKLIST—SINGLE FAMILY PROJECT Project Name: REQUIRED—2 SETS Yes No N/A 1. Building Permit completed ✓ 2. Energy Code inspector's report from REScheck completed 3. Septic alteration 4. Solid Fuel Burning or Gras Appliance form completed V 5. Driveway Permit 6. Structural.Drawings V` a. Floor plans L,/ b. Foundation plans c. Cross Sections d. Elevations e. Window&Door Schedule f. Natural Light,Ventilation and Emergency Egress 7. Plot plan.: Show proposed structure(s)with setback dimensions from all surveyed property lines ►/� 8. Electrical inspection agency selected CHECKLIST—MULTI-DWELLING/COMMERCIAL Project Name: REQUIRED—2 SETS Yes No N/A 1. Building permit application completed , 2. Energy Code COMcheck and inspector's report form completed 3. Septic alteration 4. Solid Fuel Burning or Gas Appliance form completed 5. Driveway Permit 6. Structural Drawings a. Floor plans b. Foundation plan c. Cross Sections d. Elevations e. Design loads including floor,snow&wind load f. Seismic design g. Plans signed&sealed by registered architect or engineer h. Window&Door schedule 7. Plot plan: Show proposed structure(s)with setback dimensions from all surveyed property lines 8. Electrical inspection agency selected Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: Ib Tax Map ID TAx MAP ID: Permit No. ZONE: Permit Fee APPLICANT LleA e_0 //p f f�, 4/41-f l� PHONE/E-MAm ADDRESS '7x'0 J 0,4.57_ L- - A/ •� - ����� INSTALLER/ `` PHONE/E-MAIL BUILDER (,eI!fev IN'' OWNER a A ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: K Acv ($Ike A PHONE/E-MAIL /,_r�dleoib rl, ' ((i//Q XLP Comt_(,rG6tr_ RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes No 1981-1991 Spa or Hot Tub installed Yes No 1992-Present PARCEL INFORMATION Topography _L/ Flat rolling Steep slope %Slope Soil Nature j,-*' Sand Loam Clay Other Groundwater At what depth: 9-a` Bedrock/Impervious material At what depth: -- Domestic Water Supply ✓Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: _per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size QV gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length -2-Q ft.:Each Trench S S Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and allrequirementsof the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: /C e.� fI'L T P DATE: _S f a J`!/9' SIGNATURE: DATE: �12 �t Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-7454466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: rI 5"1/6 Applicant Name: ee IAA c 0 Telephone No.: 3 K S S-8-79-72- Address to be Inspected 'n cA',f"Lrti fit. Return Address: E Liu • J, A}..Y- Applicant y.Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED { ) Slight Swale ( ) Deep Swale ( ) Level with the road { ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. .STEP 2: { ) Final Approval ( } Rejected Date: Thomas R.Van Ness,Highway Superintendent David Duell,Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 2010 New York Energy conservation Construction code MAW 2 5 2016 Energy Efficient � � EU�ILD?!4G & 110 ES Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling 1 Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Fartor SHGC Window 0.30 Door 0.21 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments CRESc eck Software Version 4.6.0 �(J Compliance Certificate Project Lot 8 - 37 Caitlin Drive Energy Code: 2010 New York Energy Conservation Location: Warren County, New York Construction Type: Single-family Project Type: New Construction MAY 2 5 2016 Conditioned Floor Area: 2,394 ft2 1 ­_­_-1_Q_U_ Glazing Area 13% T 1A OF I=tN.�Lj_ I Climate Zone: 6 (7635 HDD) BUILDNG CODES Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 37 Caitlin Drive Kenneth Collette KELACO Lot 8 Collette Construction Queensbury, NY 35 Front Street Lake George, NY 12845 commiance: Passes.using-UA trade-off compliance: 2.6%Better Than Code Maximum UA: 311 Your UA: 303 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Glazing Assembly or R-Value R-Value or Door UA Perimeter U-Factor Ceiling 1: Flat Ceiling or Scissor Truss 1,004 38.0 0.0 0.030 30 Ceiling 2: Flat Ceiling or Scissor Truss 390 38.0 0.0 0.030 12 Wall 1: Wood Frame, 16" o.c. 1,648 21.0 OX 0,057 78 Window 1: Vinyl Frame:Double Pane with Low-E 215 0,300 65 Door 1: Solid 21 0.210 4 Door 2: Solid 38 0.210 8 Wall 2: Wood Frame, 16" D.C. 1,147 21.0 0.0 0.057 56 Window 2: Vinyl Frame:Double Pane with Low-E 152 0.300 46 Door 3: Solid 18 0,210 4 Compliance Statement: The proposed building design described here 44,�q�ostent with the building plans, specifications, and other calculations submitted with th fication.The proposed b en ned to meet the 2010 New York Energy ion (M �11 n U�t� Conservation Construction IR=11t i ion 4 6.0 d to c ply ith the mandatory requi pments,listed in the REScheck Inspectio I Ced to Ith th Name-Title Signatu. U 0 Project Title: Lot 8 -3 1 -m4r, Report date: 05/25/16 Data filename: CAUsersN �4 k� \J udson\REScheck\Shea\Lot 8_37 Caitilin.rck Pagel of I kQ* ;W CREScheck Software Versions 4.6.0 �(J Inspection checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. for each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section ; Plans Verified Field Verified i & Req.3[JI Pre-lnspection/Plan Review Value I Value Complies? Comments/Assumptions 103.2 Construction drawings and ❑Complies [PR111 documentation sufficiently ❑Does Not demonstrates energy code compliance for the building []Not Observable envelope. ❑Not Applicable 103.2,Construction drawings and ❑Compiles 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code compliance for lighting and ❑Not Observable mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]"' sized per ACCA Manual 5 based Btu/hr Btu/hr []Does Not `V on loads per ACCA Manual J or Cooling' Cooling: other approved methods, QNot Observable Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) i 2 iMedium Impact(Tier 2) i 3 ILow Impact (Tier 3) Project Title: Lot 8 - 37 Caitlin Drive Report date: 05/25/16 Data filename: C:lUserslPubliclDocumentsl udson`REScheck\Shea\Lot 8-37 Caitilin.rck Page 2 of 6 2010 New York Foandatton Inspection es? Comments/Assumptions Energy, 303.14 Exposed foundation insulation ;❑Complies [FQll]? protection. ;❑Does Not - i .❑Not Observable ❑Not Applicable 403.8 !Snow melt controls. ;❑Complies [F012jz !❑Does Not ` ONot Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) '2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lot 8-37 Caitlin Drive Report date: 05/25/16 Data filename: C:\Users\Public\DocumentsVudson\REScheck\Shea\Lot 8_37 Caitilin.rck Page 3 of 6 Section Plans Verged Field Verified # Framing /Stough-In Inspection Value Value Complies? Comments/Assumptions 1402.4.4 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not -� AAMA/WDMA/CSA 101/l.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate&It;= 2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]' air handlers,filter boxes, and ❑Does Not V. building cavities used as return ducts are sealed. ❑Not Observable []Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. [-]Does Not ! [-]Not Observable -.0-Not-Applicable 403.3 HVAC piping conveying fluids R- R- [-]Complies €FR1712 above 105 QF or chilled fluids ❑Does Not below 55 4F are insulated to R-3. r ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water R- R- ❑Complies [FR18]2 pipes are insulated to R-2. ❑Does Not . ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not XA intakes and exhausts. [-]Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 JHigh Impact(Tier 1) 2 1Medium Impact (Tier 2) 13 Low Impact(Tier 3) Project Title: Lot 8 - 37 Caitlin Drive Report date: 05/25/16 Data filename: C:1Users\PubliclDocumentsWudson\REScheck\SheaNLot 8_37 Caitilin.rck Page 4 of 6 2010 We York Insulation,lnspection Complies?. Comments/Assumptioins Energy 303',1 -:;All installed insulation labeled or i❑Complies [IN131. 3installed R-values provided. ;❑Does Not ;❑Not Observable' .;i ;❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2'.' Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Lot 8-37 Caitlin Drive Report date: 05/25/16 Data filename: C:\Users\Public\Documents�udson\REScheck\Shea\Lot 837 Caitilin.rck Page 5 of 6 Section Plans Verified Field Verified & R p,lp Final Inspection Provisions Value I Value Complies? Comments/Assumptions 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not i[F117]1 of<7 ACH at 50 Pa.This []Not Observable ,9 requirement may instead be met via visual inspection, in which ❑Nat Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm ❑Complies [FI4]1 construction with maximum []Does Not t-. leakage of 8 cfm to outdoors, or ❑Nat Observable 12 cfm across systems. For rough-in tests, verification may []Not Applicable need to occur during Framing Inspection, with maximum leakage of 6 cfm across systems and 4 cfm without air handler.__ 403.1.1 Programmable thermostats _ ❑Complies [F19]2 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Nat Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water T� MComplies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable _ 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Not Observable []Not Applicable Additional Comments/Assumptions: 1 -High Impact (Tier 1) 2 ',Medium Impact{Tier 2) 3 Low Impact(Tier 3) v J Project Title: Lot 8 - 37 Caitlin Drive Report date: 05/25/16 Data filename: C:1Users\PubliclDocumentsVudsonlRE5check\Shea\Lot 8_37 Caitilin.rck Page 6 of 6 o L -0 MAY 2 5 20161 B-"ED ALL OBJECTS T7r—VN—OrdRE-FEK B-URY I Wvt SEEN OR OMER\ BUILDING & CODES WELLS TREES, mus,ETC .,SUCH AS HOUSES. E PERSQNALLY S}"ON THIS E)OSUME4,I KAV U�GRAM i DATE Sl NATUR -A pk �f`(�Iltz� . ' r f j