Loading...
RC-000327-2016 TOWN OF QUEENSBURY 742 Bay Road Queensbury,NY 12804-5904 (518)761-8201 -- Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000327-2016 Date Issued: Friday, September 16, 2016 This is to certify that work requested to be done as shown by Permit Number RC-000327-2016 has been completed. Tax Map Number: 308.12-1-33 Location: 104 BURNT HILLS DR Owner: Michaels Group Homes,LLC Applicant: Michaels Group Homes,LLC This structure may be occupied as a: Single Family Dwelling w/FP 2524 s.f. 2-car Garage 472 s.f. By Order of Town Board Laric Development,Lot 8 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, �d Variance,or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building&Code Enforcement :r TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-000327-2016 Tax Map No: 308.12-1-33 Permission is hereby granted to: Michaels Group Homes, LLC For property located at: 104 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tuve of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $250,000.00 Owner Address: 10 Blacksmith DR Total Value $250,000.00 Malta,NY 12020 Contractor or Builder's Name 1 Address Electrical Inspection Agency Tony LoCascio Plans& Specifications Single Family Dwelling wIFP 2524 s.f. 2-car Garage 472 s.f. Laric Development, Lot 8 $ 1,475.60 PERMIT FEE PAID -THIS PERMIT EXPIRES: Monday, June 5,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town r7;j 4Frg-M , 2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement i PRINCIPAL STRUCTURE APPLICATION Office Use Only Received Date: Tax Map ID Tax Map 1D -3 3 Permit No. r�,- �v2�- 2-0 1a Permit Fee �rlv• rp Zone M Rec Fee Historic Site Yes X No Site Plan## L"_ren,rs of# Subdivision# 'a&��an I � Subdivision Name �f �,� Project Location too �r�e.�r 1'i tins 1ztu= TOWN 1313. RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family, duplexes/two-family, multiple family,apartments, condominiums,townhouses, and/or manufactured & modular homes, but not mobile homes. This is in addition to the permit fee(s). Applicant MwjAma sr, (sima.P PvLuEs.,LLL Owner ' O V.AiE Address to sl„rnN4 Iazxua Address MAA-rA,i t14`r Iza ZJb Phone/E-mail ac,y X331 Phone/E-mail Contact Person for Building&Codes Compliance: (�4 5 G10 Phone'$5 7 31191-'-6 TYPE OF CONSTRUCTION v'Check all that apply New Addition Alteration I"floor sf 2na floor sf Total sf Height Single Family t�1 ka 5 C� 42.4 � 2,5 2 4 Two-Family Multi-Family D C El- (#of units l4 EI; i Townhouse MAY 3 1 U16LUI Business Office TO N C?FQUEM 5UF2Y U1LD1 Retail -Mercantile Factory- Industrial Attached.Garage (1,(D3, 4+) X 417. Other If commercial or industrial please indicate of business Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 Proposed use of building or addition 'GIMLA,,e o�►►�t�r -- so Source of Heat(circle one) (QD Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? Ev p Site Information a. Dimensions or acreage of lot 2- b. b. Is this a corner lot? AJ U c. Will the grade be changed as a result of construction Yes No d. Public water or Private well 1PUek C_ e. Sewer or Private Septic System sett., Value of all work to be performed (labor or materials) $ Z n DECLARATION.- 1. ECLARATION:1. 1 acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the I year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application,plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations 4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: �a � S cl DATE: S ? SIGNATURE: DATE: —A For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duel] Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT � • �� �y _ 2iD1 � Date: 92ev 1 ta LWN fir' Applicant Name: t�+�c_►-t .s �rzu a is , u� + Telephone No.: �+�. +�.cna� 1 2016 Address to be Inspected t o 4 +gutan +ei1C.t 5. L»�� EENS8l1RY & C©DES Return Address: +b .AJA,I%-" Z*Z4 1 Z I 1ti.�c. ,N•.i I-WZO Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( } Deep Swale { } Level with the road ( } Level with the top of the paved wing Size culvert pipe to be used(if necessary) O I2" O 15" ( ) I8 O 24" ( } 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: Tax Map ID TAX MAP ID: Permit No. , 3�.�{ 2,0 t ZONE: Permit Fee APPLICANTMIG-16. L_S C,lizcat eP I-tRj+1 es" LLL PHONE/E-MAIL C51q ,c65c, , 63 11 ADDRESS Io 6l?EaLS�atii�-4 �¢i�l�, t%A ,tV�f 17-0Z-C:) INSTALLER/ CMp4 z LxY-.D. FR-r a n b 1S 1=w_A A, 'M KtL; PHONE/E-MAIL �5k9-� . -14-7 .C1 16-11 BUILDER OWNER INA104AAE,,S GZEXA7 "c7Y. e5, LLL sts .Qfy9 . b311 ADDRESS Ct�P'�t-_-T1V_vGR47'11 CONTACT PERSON FOR BUILDING&CODE.COMPLIANCE: TM-r L.0C.t-�SC%0 PHONE/E-MAIL 5kS•744 ,ZciC,3 RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes K No 1981-1991 Spa or Hot Tub installed Yes c No 1992-Present 3 a 3 3 PARCEL INFORMATION I n ( Topography X Flat rolling Steep slope %Slope -- , Soil Mature Sand Loam Clay er AY 3 ���� Groundwater At what depth: Bedrock/Impervious material At what depth: P461BUILDING & CODS Domestic Water Supply - (_Municipal Well(if well, water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size t)� gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total lengthft.;Each Trench Seepage Pit with 43 stone How many: ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2) We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirem //o--f the Town of Queens ury Sanitary Sewage Disposal Ordinance. PRINT NAME: i��' Sud DATE: 3 SIGNATURE: DATE: Town of Queensbury Building&C cs Principal Structure Application Revised September 2015 Fuel Burning Appliance & Chimney Application Office Use Onay Received DATE: Tax Map ID TAX MAP ID: Permit No. F C • 32'�._2�L� Permit Fee $S� ZONE: OWNER M11G4 iL� l S CJML% ' Home;., LLC_ PHONE/E-MAIL -5 CbC'%9 • (P iA I ADDRESS Lo FbLAQ4s1-ktT%A D1u1 , M,at."Tp. , WY IZ02-0 INSTALLER/ pS�T �j � � PHONE/E-MAIL 5+q2>,g66ci."i u BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: r� G PHONE/E-MAIL X51 :31 Q 4 BUILDING ADDRESS 104 s3t�cz H1L�Sztiy r ROOM OF INSTALL: L-ty I►a-G PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE, FACTORY BUILT* X NOTE: MANUFACTURER'S FIREPLACE, MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: Hewr -4cju:> ; Model#: sL_--15a Listed by: v•t_ Number: y L.- 15m-3 13 CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: -. ;- kl. DECLARATION: Construction/installation must conform to NYS F r Bui evention & lding e` and/or manufacturer requirements. The applicant or owner agrees to com 1 th Wiplaida1� es i iances, regulations, and all conditions that are part of these requirements and al o wi L allow inspector's to e ter p etnises to perform required inspections. T5Wtd OF QUE ff_R B RY BUILDING & CODES I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: +,f'' o�445aa DATE: ' SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 REScheck Software Version 4.6.2 Compliance Certificate Project The Parker Energy Code: 2010 New York Energy Conservation --------- - --�--- -• Location: Warren Countv, New York ECEif Construction Type: Single-family Project Type: New Construction i Orientation: Bldg. faces 45 deg. from North MAY 3 1 2016 Conditioned Floor Area: 2,524 ft2 Glazing Area 13% TOWN OF QUt�'S 't.J Y Climate Zone: 6 (7635 HDD) BUILDING & 'C'00E" Permit Date: 23 May, 2016 Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 104 Burnt Hills Drive The Michaels Group, LLC Queensbury, NY 10 Blacksmith Drive Malta, NY 12020 ,Compliance: Passes using performance 308.12-1-33 Rt-000327-2016 Compliance: 3.6%Better Than Code Michaels Group 1.04 Burnt Hills Dr., Lot 8 SFD W/FP 2524 SJ., 2-car garage 472 SJ. Envelope Assemblies AssemblyGross Area Cavity Cant. Perimeter Foundation Wall: Solid Concrete or Masonry 274 0.0 13.0 0.052 14 Orientation: Left side Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' 1x Std Basement Window: Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC: 0.27 Orientation: Left side Foundation Wall: Solid Concrete or Masonry 175 0.0 13.0 0.052 9 Orientation: Front Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Foundation Wall: Solid Concrete or Masonry 342 0.0 13.0 0.052 18 Orientation: Back Wall height: 7.6' Depth below grade; 6.6' Insulation depth: 7.6' 1x Std Basement Window: Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC: 0.27 Orientation: Back Foundation Wall: Solid Concrete or Masonry 429 OA 13.0 0.052 22 Orientation: Right side Wall height: 7.6' Depth below grade: 6.6' Insulation depth; 7.6" Project Title: The Parker Report date: 05/24/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge1104 Burnt Hills Drive.rck Page 1 of 8 Gross Area Cavity Cont. Perimeter 1x Std Basement Window: Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC: 0.27 Orientation: Right side 1st Floor Walls: Wood Frame, 24" o .c. 207 21.0 0.0 0.056 7 Orientation: Front Mud #20: Solid 19 0.170 3 Orientation: Front Foyer#1: Solid 21 0.170 4 Orientation: Front 2x Home Office (0): Wood Frame:Double Pane with Low-E 36 0.300 11 SHGC: 0.27 Orientation: Front 1st Floor Walls:Wood Frame, 24" o .c. 405 21.0 0.0 0.056 17 Orientation: Back 2x Great Room (E): Wood Frame:Double Pane with Low-E 29 0.300 9 SHGC: 0.27 Orientation: Back Ix Great Room (R): Wood Frame:Double Pane with Low-E 27 0.300 8 SHGC: 0.27 Orientation: Back 2x Dining (C): Wood Frame:Double Pane with Low-E 21 0.300 6 SHGC: 0.27 Orientation: Back 1x Dining (H): Wood Frame:Double Pane with Low-E 33 0.300 10 SHGC: 0.27 Orientation: Back 1st Floor Walls: Wood Frame, 24" o .c. 324 21.0 0,0 0.056 18 Orientation: Left side Ix Powder(AM): Wood Frame:Double Pane with Low-E 7 0.300 2 SHGC: 0.27 Orientation: Left side 1st Floor Walls: Wood Frame, 24" o .c. 509 21.0 0.0 0.056 27 Orientation; Right side Ix Mud (AC):Wood Frame:Double Pane with Low-E 4 0.300 1 SHGC: 0.27 Orientation: Right side #19 Dining: Glass 19 0.290 6 SHGC: 0.20 Orientation; Right side 2nd Floor Walls: Wood Frame, 24" o .c. 424 21.0 0.0 0.056 19 Orientation: Front 2x Bed #3 (AT): Wood Frame:Double Pane with Low-E 32 0,300 10 SHGC: 0.27 Orientation: Front Ix Hall (AT):Wood Frame:Double Pane with Low-E 16 0.300 5 SHGC: 0.27 Orientation: Front 2x Bonus (AT): Wood Frame:Double Pane with Low-E 32 0.300 10 SHGC: 0.27 Orientation: Front 2nd Floor Walls: Wood Frame,24" o.c. 264 21.0 0.0 0.056 11 Orientation: Back Ix Master Bed (G): Wood Frame:Double Pane with Low-E 32 0.300 10 SHGC: 0.27 Orientation: Back 2x Bed #2 (AT):Wood Frame:Double Pane with Low-E 32 0.300 10 SHGC: 0.27 Orientation: Back 2nd Floor Walls:Wood Frame,24" o .c. 288 21.0 0.0 0.056 14 Orientation: Left side Project Title: The Parker Report date: 05/24/16 Data filename: F:IShare\Design\Res-Check\Burnt Ridge1104 Burnt Hills Drive.rck Page 2 of 8 Gross Area Cavity Cant. Perimeter 2x Master Bed (Z):Wood Frame:Double Pane with Low-E 26 0.300 8 SHGC: 0.27 Orientation: Left side 1x Master Bath W; Wood Frame:Double Pane with Low-E 4 0.300 1 SHGC: 0.27 Orientation: Left side 2nd Floor Walls: Wood Frame, 24° o .c. 448 21.0 0.0 0.056 25 Orientation: Right side 1x Main Bath (AM): Wood Frame:Double Pane with Low-E 7 0.300 2 SHGC: 0.27 Orientation: Right side Ceiling: Raised or Energy Truss 1,603 38.0 0.0 0.025 40 Cantilever:All-Wood joist/Truss:Over Unconditioned Space 40 30.0 0.0 0.033 1 Floor Above Garage: All-Wood Joist/Truss:Over Unconditioned Space 398 30.0 0.0 0.033 13 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy , Conservation Construction Code requirements in REScheck Version 4.6. ciwith the mandatory requirements listed in the REScheck Inspection Checklist. lj '�`�`i'pt Name-Title Sig L Date nYQ `-"Iva v p 06831 slo Project Title: The Parker Report date: 05/24/16 Data filename: F:1Share\Design\Res-Check\Burnt Ridge1104 Burnt Hills Drive.rck Page 3 of 8 REScheck Software Version 4.5.2 Inspection checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section plans Verified Field Verified # Pre-Inspection/Plan Review Value ValueComplies? comments/Assumptions & Req.1D 103.2 Construction drawings and ❑Complies [PR111 documentation sufficiently []Does Not demonstrates energy code compliance for the building []Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code compliance for lighting and ❑Not Observable mechanical systems.Systems E]Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not f on loads per ACCA Manual J or Cooling: Cooling: other approved methods. Btu/hr Btu/hr []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 ,High Impact(Tier 1) 2 (Medium Impact(Tier 2) 3 1 Low Impact (Tier 3) Project Title: The Parker Report date: 05/24/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\104 Burnt Hills Drive.rck Page 4 of 8 Section # Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 Exposed foundation insulation ❑Complies [FO11]2 protection. ❑Does Not ❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 3 Low Impact(Tier 3) Ll Project Title: The Parker Report date: 05/24/16 Data filename: F:15hare\Design\Res-Check\Burnt Ridge1104 Burnt Hills Drive.rck Page 5 of 8 section Plans Verified Field Verified # Framing I Rough-In Inspection Value Value Complies? Comments/Assumptions & Re ,ID 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/i.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not U), and labeled to indicate&It;= 2.0 '' cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes, and ❑Does Not building cavities used as return ducts are sealed. ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR1513 ducts or plenums. ❑Does Not V, ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not v below 55 QF are insulated to R-3. ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water R- R- ❑Complies [FR18]2 pipes are insulated to R-2. ❑Does Not V. ❑Not Observable ❑Not Applicable _ 403.5 Automatic or gravity dampers are ❑Complies mT [FR 1912 installed on all outdoor air ❑Does Not intakes and exhausts. ,_. ❑Not Observable ❑Nat Applicable Additional Comments/Assumptions: Z High lmpact(Tier 1) 2 Medium Impact(Tier 2) 3 j Low Impact(Tier 3) Project Title: The Parker Report date: 05/24/16 Data filename: FAShare\Design\Res-Check\Burnt Ridge1104 Burnt Hills Drive.rck Page 6 of 8 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID _ 303.1 All installed insulation labeled or ❑Complies [IN13]2 installed R-values provided. ❑Does Not ❑Not Observable ❑Not Applicable Additional CommentslAssumptions: 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Cow Impact(Tier 3) Project Title: The Parker Report date: 05/24/16 Data filename: F:15harelDesignlRes-ChecklBurnt Ridge1104 Burnt Hills Drive.rck Page 7 of 8 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .10 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [FI1711 of&lt;7 ACH at 50 Pa.This requirement may instead be met ❑Not Observable via visual inspection, in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm ❑Complies [FI4]1 construction with maximum ❑Does Not #_ leakage of 8 cfm to outdoors, or 12 cfm across systems. For ❑Not Observable rough-in tests, verification may ❑Not Applicable need to occur during Framing Inspection, with maximum leakage of 6 cfm across systems and 4 cfm without air handier. 403.1.1 Programmable thermostats ❑Complies [FI 912 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. []Nat Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Nat Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: The Parker Report date: 05/24/15 Data filename: F:\Share\Design\Res-Check\Burnt Ridge1104 Burnt Hills Drive.rck Page 8 of 8 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 13.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass &Door Rating U-Factor- SHGC Window 0.30 0.27 Door 0.17 0.20 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments u��lya N P I LLJ� �(cl $zN 3 00 '9Lsa ,89'96 o LL '8£ N a °u ti o Ll N a) ri m N � m rn D OOm N U C=Q �y oa M Off_ N i, ALn O<,� n I M� 2N �D Cm G Z C u.Oz C �p E ti O tc,„�= A M ri InU?0O rn m S uL I _ F I ® z Lu h O o U NV d P=-4 m Q) J p Z c�cm N� v M c m ^ m I 6 Q d)U j $ tp U W G ~ fN N O O \ ~ 4] W _7 N I Y O z 3 I1n0 ON V� Fd iL1 3� HOZ r� a 9041 � a �6 o � w m N W � v