Loading...
RC-000034-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000034-2016 Date Issued: Monday, August 28, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000034-2016 has been completed. Tax Map Number: 239.12-2-19 Location: 61 ASSEMBLY POINT RD Owner: Dawn Hamilton,Jeffrey Hamilton Applicant: Howland Construction This structure may be occupied as a: SFD w/FP: 1st floor: 1,222 sq. ft.2nd floor: 806 sq.ft.Total sq. ft.:2,028 (no garage);Cross Ref.AV 63-2015& By Order of Town Board PZ-0002-2015&SP 60-2015;ZBA Cond.of App.on Reso.:5.Approval TOWN OF QUEENSBURY Conditions:a.We condition this that the applicant must follow the guidelines of the shoreline re-buffering of the Town of Queensbury;b.Also,the driveway should not be paved in the future unless they come back&ask for a variance. Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY N 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 - Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit NUmber: RC-000034-2016 Tax Map No: 239.12-2-19 Permission is hereby granted to: Jeffery Hamilton,Dawn Hamilton For property located at: 61 ASSEMBLY POINT RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Dawn Hamilton Single Family-New $500,000.00 Owner Address: 1203 Aston CT Total Value $500,000.00 Chester Springs,PA 19425 Contractor or Builder's Name/Address Electrical Inspection Agency Howland Construction 7 IROQUOIS DR DR Queensbury,NY 12804 Plans&Specifications Single Family Dwelling: Ist floor: 1,222 sq.ft.. 2nd floor: 806 sq.ft./Total sq.ft.: 2,028 with fireplace (no garage) Cross Ref. AV 63-2015&PZ-0002-2015 and SP 60-2015 ZBA Condition of Approval on Resolution: 5. Approval Conditions: a. We condition this that the applicant must follow the guidelines of the shoreline re-buffering of the Town of Queensbury. b. Also,the driveway should not be paved in the future unless they come back and ask for a variance. $405.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,February 13,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o een ry; /f Fr*, e 2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement `V %l X� PRINCIPAL STRUCTURE APPLICATION Office Use Ont Dare: 1 /Z., / /4i Permit No. Tax Ma ID 2` ,q i z - 2 - 1 Map _ �l Permit Fee (.a 7e 3 Zone Historic? _Yes -- No Ree Fee ,/vice- Subdivision Name Lot# �— Site Plan# 5 Project Location { TOWN Bp.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) _ 5� , ►� Address -3 d� 5�6& a;r FSt5 A r<W 2-s r . Phone/Email — 3Zi— Applicant 1 ­,�1 ('r3As�rJ C+C 0'N__ AU Address Phone/Email - U RY Contractor --- w� a -e rL) Address _ Phone/Email DC'Pk p Contact Person for Building& Codes Compliance: Phone TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 2°a floor sf Total sf Height Single Family f 1 ZZZ 3 C'C' Z C L'3- Two-Family �Two-Family Multi-Family (#of units�) Townhouse Business Office Hamilton RC-000034-2016 Retail-Mercantile 61 Assembly Point Road Factory-Industrial S FD cross ref. A V & SP Attached Garage (1, 2, 3, 4+) r Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 I f.comrnercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Gas Oil ropane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances&Chimneys Are there structures not shown on plot plan? Are there easements on the property? AI O Site Information: a. Dimensions or acreage of lot 0-LI b. Is this a corner lot? Yes -y- No c. Will the grade he changed as a result of construction �c Yes No d. Public water or Private well(circle one) Public Pn t e. Sewer or Private Septic System(circle one) Sewer rivat Value of all work to be performed(labor or materials) $ St'o4goo -- DECLARATION.- 1. ECLARATION.1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement I description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: �,1e r� 40-31(-_k DATE: //Z1 A" SIGNATURE.--- DATE: ZQ ll� For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Y/N/ N Residential Plan Review: One &Two Family Dwellings Two(2)full sets of plans Over 1,500 sq.ft. requires engineering stamp Design loads on plans: 90 Wind Floor Loads 40 psf (north of Rt. 149 60) 50 Ground Snow Load Sleeping Areas&Attics 30 psf �j Calculations Window schedule with glass size Door schedule/Main entrance 36" door Emergency Escape or Bedrooms and Habitable Space Abo e/Below grade: 5.7 sq.ft. G de: 5.0 sq.ft. /4411 " (h)x 20"' (w)minimum maximum 'height above door Residential: Check paperwork compliance and Inspection checklist-Okay Driveway length: 300'or more-12'width required/500'or more—turnaround required Foundation insulation to basement floor Damp proofing/Waterproofing materials on plans Foundation drainage on plans, if required 6"drop in 10' Exterior grade Framing cross section for each roof line,Vertical fire stopping every 10'where required Ice&Snow Shield -24" inside exterior wall/24" inside knee walls Platforms at exterior doors Stairway headroom 6'8";all stairs 36"width Stair Run and Rise / Winder Run and Rise f Spiral not allowed from 2"d story Smoke Detectors-battery backup and proper location interconnected Bathroom fixtures-proper clearance Hall width-36"width Handrails more than four risers on open sides Railing&Guards>30"/ Basement stairs included/Closed risers more than 4" in height Safety glazing notes for required areas / Garage fire separation Garage floor sloped Attic access Roof over 30"-22"x 30"/Crawl spaces 18"x 24"access Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' of \� sleeping area Soil Test results, if required Septic to well or water line separation All p4perwork signed Note on plans energy saving light bulbs Blower door test agency paperwork . Floodplain Permit Required -Check Map Residential Plan Review-1 & 2 Family Dwellings 10-2-2014 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: 112,7116 Tax Map ID TAX MAA ID: 2,3_3. lz —-7 —f�f Permit No. ZONE: — Permit Fee APPLICANT S r PHONE/E-MAIL ADDRESS (© fRA INSTALLER/ I PI IONE/E-MAIL BuiLDER OWNER 640 -3Zt -7 r g0 ADDRESS k CONTACT PERSON FOR BUILDING&COBE COMPLIANCE: I[ 2_, PHONE/E-MAIL _ — S RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =totaI Daily flow 1980 or older Garbage grindSAWs 1$1 L .lj Yes _No 1981-1991 Spa or Hot Tub installed Yes No 1992-Present PARCEL INFORMATION Topography Flat rolling Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth:36"-a, 62,1 Bedrock/Impervious material At what depth: Domestic Water Supply Municipal _(c, Well(if well,water supply from,any septic system absorption is_ft.) Percolation Test Rate: 3,m'�Ns eac per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size LCnq_gallons(min.size 1,000 gallons,add 2.50 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: "e.n- r Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: k/� DATE: 117 r//0 SIGNATURE:.- DATE: ? Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: Tax Map ID � • 1Z Permit No. C� 3 " -�U TAx MAP ID: I �o _z 1 '. Jki-o 2 8 2016 Permit Fee ZONE: W � OWNER 5 y PHONE/E-MAIL _ 3Z.1-Z`l 96 ADDRESS & A% INSTALLER/ Cc�V�y T { ��0. PHONE/E-MAIL BUILDER �-;f �t+.Ce �(s cam. 6(9Z-3(g CONTACT PERSON FOR BUILDING&CODE COMPLIANCE:PHONE/E-MAIL 66,?--3185 BUILDING ADDRESS 61 fW ROOM OF INSTALL: )j rc,P" k _ PLANNED INSTALL DATE: �` /r FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& I FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. F CTORY BUILT NOTE: MANUF'ACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: Apof- d ec, t j V& ; Model#: Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL _>!�_TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ; Model #: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: I - DATE: L� / SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Devised January 2016 REScheck Software Version 4.6.2 -40 Af Compliance Certificate Project Hamilton, Jeff and Dawn Energy Code: 2010 New York Energy Conservation Location: Warren County, New York FILE Copy Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 2,028 ft2 Glazing Area 8% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 61 Assembly Pt Rd. Dean Howland Howland Construction Queensbury, NY 12804 Howland Construction 7 Iroquois st 7 Iroquois st Lake George, NY 12804 Lake George, NY 12845 518-668-3185 518-668-3185 dean@howlandconstruction.com Dean@howlandconstruction.com Compliance: Passes using UA trade-off Compliance: 13.5%Better Than Code Maximum UA: 304 Your UA: 263 The%Better or worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Assembly or R-Value R-Value 1-1-Factor UA Perimeter Ceiling 1: Flat Ceiling or Scissor Truss 1,222 0.0 40.0 0.024 29 Wall 1: Wood Frame, 16" o.c. 1,400 21.0 0.0 0.057 80 Wall 2: Wood Frame, 16" o.c. 955 21.0 0.0 0.057 44 Window 1: Metal Frame:Double Pane with Low-E 190 0.300 57 Basement Wall 1: Solid Concrete or Masonry 770 0.0 13.0 0.058 42 Wall height: 5.0' Depth below grade: 4.0' Insulation depth:5.0' Door 1: Solid 38 0.300 11 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6.2 and t�ly_with the mandatory requirements listed in the REScheck ln§qectipn�rChecklist. Name-Title Signature p Y�_ Date AlL Project Title: Hamilton,Jeff and Dawn ` i Report date: 02/01/16 r"tilCl`. Pa e 1 of 6 Data filename: Untitled.rck z" 9 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req,l4 103.2 Construction drawings and ❑Complies Requirement will be met, [PR111 documentation sufficiently ❑Does Not demonstrates energy code compliance for the building ❑Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code compliance for lighting and ❑Nat Observable mechanical systems.Systems ❑Nat Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR212 sized per ACCA Manual S based Btu/hr Btulhr ❑Does Not on loads per ACCA Manual J or Cooling: Cooling: other approved methods. Btu/hr Btu/hr ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Hamilton,Jeff and Dawn Report date: 02/01/16 Data filename: untitled.rck Page 2 of 6 Section # Foundation Inspection Complies? Comments/Assumptions 1303.2.1 Exposed foundation insulation ❑Complies Requirement will be met. (F011]2 protection. ❑Does Not ❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies (FO12]2 ❑Does Not ❑Not Observable ❑Nat Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Hamilton,Jeff and Dawn Report date: 02/01/16 Data filename: Llntitled.rck Page 3 of 6 Section Plans Verified Field Verified # Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions I& keq.ID 402,4.4 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met, [FR16]2 sealed at housing/interior finish []Does Not p and labeled to indicate&It;=2.0 - cfm leakage at 75 Pa. ❑Nat Observable ❑Not Applicable 403.2.2 All Joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes, and ❑Does Not building cavities used as return ❑Not Observable ducts are sealed. ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. []Does Not °* ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑complies [FR17]2 above 105 QF or chilled fluids []Does Not below 55 QF are insulated to R-3. ❑Nat observable ❑Not Applicable 403.4 Circulating service hot water R- R- ❑complies [FR18]2 pipes are insulated to R-2. ❑Does Not []Not Observable []Not Applicable 403.5 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not V intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Hamilton,Jeff and Dawn Report date: 02/01/16 Data filename: Untitled.rck Page 4 of 6 303.1 All installed insulation labeled or LJComplies Requirement will be met. [IN13]7 ,installed R-values provided. ❑hoes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Lown Impact(Tier 3) Project Title: Hamilton,Jeff and Dawn Report date: 02/01/16 Data filename: Untitled.rck Page 5 of 6 Section # Insulation Inspection Complies? Comments/Assumptions &Req.ID Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &'Req.ID 402.4.2, Building envelope tightness ACH 50= ACH 50= ❑Complies Requirement will be met. 402.4.2.1 verified by blower door test result []Does Not [FI17]1 of&It;7 ACH at 50 Pa.This requirement may instead be met ❑Not Observable via visual inspection,in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm ❑Complies [F14]1 construction with maximum ❑Does Not leakage of 8 cfm to outdoors, or .12 cfm across systems. For ❑Not Observable rough-in tests, verification may ❑Not Applicable need to occur during Framing inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1,1 Programmable thermostats ❑Complies [F19]7 installed on forced air furnaces. ❑Does Not []Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. , ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies Requirement will be met. (F17]2 ❑Does Not ❑Not Observable _❑Not Applicable 3033 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Not Observable L ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) Z Medium Impact('tier 2) 3Low Impact(Tier 3) Project Title: Hamilton,Jeff and Dawn Report date: 02/01/16 Data filename: Untitled.rck Page 6 of 6 2010 New York �} Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 13.00 Floor 0.00 Ceiling / Roof 40.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.30 Door 0.30 CoolingHeating& Heating System: Cooling System: Water Heater: Name• Date• Comments Truss ID Signage required at Electrical Deter for all 2015 Residential and Duplex Permits 6 inch circle with white reflective background and red letters and red striping c"••';I' ry l 6� ++tea^J Circle one "to be used / I NOTE: Boundary information reproduced from a survey performed by David J. Bolster for Jeffrey M. Hamilton & Dawn. M. Hamilton, dated 14 December 2012. As built survey performed by D.L. Dickinson a ' Associates, 2 February 2017. MAP 9,00t Dock& Boathouse per Bolster survey 0 0 4.8' I 0e Py 66'1 C� o Lake Georgen, Area = 0.211 acres Y o 4 8'/8 50'1 along shoreline as it winds & turns. _� o �. /0 Lake Elevation 9-29-15 = 319.07' HOUSE / ` cyton ane \\\0 Sepf/ / /84 39 ` PORCH r, j� 9.0' ST oNF RETAiyj l`'� n �� 44 co j IV Parking /b of an a5-built survey for Ry Ilk& 51tu to In >a p I 3`900„� I Town of Queensbur County of Warren ;,�;.,�,,,, r� &0 State o New York — Mappinq Notes Scale: 1 — 20 feet ate: 2 February 2017: j p .s0 0 Note: Only title surveys bearing the maker's 5—y.,d Map by y j ,. - - =-- =-��-