Loading...
BINS-003423-2019 06102019INSPECTION WORKSHEET (BINS-003423-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-000367-2016 Case Module:Permit Inspection Date:Mon Jun 10, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Insulation Job Address:Parcel Number:74, 76, 80, 82, 86, 88, 92, 94 Wedgewood DR Bldg. 6 Queensbury, NY 12804 302.9-1-28.1 Contact Type Company Name Name Granted Permission Schermerhorn R.E. Holdings VANDERWARKER, DARREN Architect Rucinski-Hall Architecture Contractor Schermerhorn R.E. Holdings VANDERWARKER, DARREN Primary Owner SCHERMERHORN WEDGEWOOD LLC Applicant Schermerhorn R.E. Holdings VANDERWARKER, DARREN Checklist Item Passed Comments Building Inspector Notes NO 6/10/19 Insulation Partial Approval - Sound batt Insulation in end units at first floor unit ceilings. - Sound batt Insulation in apartment common walls behind utility soffits. - Exterior Wall Insulation at front doors of center units and rear exterior walls behind utility soffits. Window Sealing NO U Factors = .3 cfm for windows, .5 cfm for doors NO Tyvek or Similar Exterior Sealant NO Jun 10, 2019 Page (1) INSPECTION WORKSHEET (BINS-003423-2019) Checklist Item Passed Comments Proper Vent, Attic Vent NO Insulation Residential Check Commercial Check NO 6/10/19 Insulation Partial Approval - Sound batt Insulation in end units at first floor unit ceilings. - Sound batt Insulation in apartment common walls behind utility soffits. - Exterior Wall Insulation at front doors of center units and rear exterior walls behind utility soffits. Blower Door Test NO Combustion Air Supply for Furnace NO Fresh air supply 3' from grade NO Duct Insulation - if required in unheated spaces NO Door / Window Sealed (No Insulation)NO Air Barrier behind Knee Walls NO Tub Shower R-20 with Vapor Barrier NO All Ductwork Sealed Return and Supply NO Duct Blaster Test for duct work, R-8 NO All Return Air Hard Duct Work NO House Wrap Taped at all Seams NO Jun 10, 2019 Page (2) O'Brien, John (Inspector)