Loading...
CC-000073-2016 TOWN OF QUEENSBURY 742 Bay.Road,Queensbury,NY 12804-5904'(518)761-8201 Community Development-.Building&Codes (518)761-8256 CERTIFICATE -OF OCCUPANCY Permit Number: CC-000073-2016 Date Issued: Thursday, December 7,,2017 This is to certify that work requested to be done as shown by Permit Number CC-000073-2016 has been completed. Tax Map Number: 309.10-1-10 Location: 64 MAIN ST Owner: Apex Solar Power Applicant: Stan Dobert This structure may be occupied as a:Interior Commercial Alterations Basement Office Only By Order of Town Board Apex Solar Power TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a,result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building-&Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000073-2016 Tax Map No: 309.10-1-10 RENEWED Permission is hereby granted to: Apex-Demarse LLC For property located at: 64 MAIN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Apex Solar Power Factory-Industrial-Alteration $20,000.00 Owner Address: 64 MAIN ST Total Value $20,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Apex-Demarse LLC 64 MAIN ST Queensbury,NY 12804 Plans&Specifications Interior Commercial Alterations: 1932 s.f.basement,405 s.f.main,2337 total square footage Apex Solar Power $467.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,March 2,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensb or the a ratio date. Dated at the Town o Queens �We March 2,2016 SIGNED BY: tltltltl for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF-QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERM-IT. Permit Number: CC-000073-2016 Tax Map No: 309.10-1-10 Permission is hereby granted to: Apex-Demarse LLC . For property located at: 64 MAIN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name:. Apex Solar Power Factory-Industrial-Alteration . $20,000.00 Owner Address: 64.MAIN ST Total Value $20,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Apex-Demarse LLC 64 MAIN ST Queensbury,NY 12804 Plans&Specifications Interior Commercial Alterations: 1932 s.f.basement,405 s.f.main,2337 total square footage Apex Solar Power $467.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,March 2,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queen ury; Wednesday,March.2,2016 SIGNED BY: or'the Town of Queensbury: Director of Building&Code En a en PRINCIPAL STRUCTURE APPLICA 'Z�ON, Office Use-:Only Date: 2-16-16 -- �ICI r N � ©�-� 2�1 Tax Map ID 309.10-1- ,309.10-1-10 F a PermitlE o Zone MAIN STREET Historic? t- Re4ee/ _Yes- =_No JU6 d %,, Subdivision.Name N/A Loft#�fh : r �`�6" Plan. L ^r,,_3ubdivisi n.# Project Location 64 Main Street Queensbury, NY 128W TOWN BD.RESOLUTION 86-2019 850 recreation fee for new;dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townh"buses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owners) Stan Dobert Address 64 Main Street Queensbury, NY 12804 Phone/Email (518) 309-2786 work (970) 531-7855 mobile / mdobert@gmail.com Applicant Stan Dobert Address see above Phone/Email see above Contractor Address Phone/Email Q Dr3ii2 �L .CC." Contact Person for Building;&.Codes Compliance: Dave Hatin Phone (518) 761-8256 Andrew Allison (518) 792-1651 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1s'floor sf 2"d floor sf Total:sf' Height Single Family TwoTamily Mu ti-Family {#of units Townhouse Basement: Main Level: 2,337 Main:9'4'VAI ES Business Office X 1,932 405 Basement: 8'-4' Retail-Mercantile Factory.-Industrial Attached.Garage (1, 2, 3, 4+) Other Town of Queensbury Building&.Codes Pr'inc pat structure Application revised January 2016 If.cemmercial or industrial please indicate name of business Apex Solar Power 1 Proposed use of building or addition Office Space Source of Heat(circle one) Gas Oil Propane Solar. Other Fireplace: Complete a separate application for Fuel Burning N/A Appliances&Chimneys Are'there structures not shown on plot plan? N/A ALTERATIONS DO NOT AFFECT PLOT PLAN Are there easements on the property? N/A ALTERATIONS DO NOT AFFECT EASEMENTS Site Information: a. Dimensions,or.acreage of lot 1.981 ACRES b. Is this a corner lot? X Yes No c. Will the grade be changed as a result of construction X Yes No d. Public water or Private well(circle one) Public Private e. Sewer or Private Septic System(circle one) ewer Private Value of all-work to be performed(labor or materials) $ 12 Z) o vc) DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: ��-� bb I DATE: Z ) I\o SIGNATURE: DATE: It'll U L/11 T For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 COMlcheck Software Version 400.2:0 it FEB19 16�LU Envelope Compliance Certificate Tu,.J�,;, C;- ; �L;�;�SBU�Y BUILDI�!� & CODES koject Information Energy Code: 2014 New York Energy Censer:Cont3fr.Code(by application ot.90.1(2010)Standard). Project Title: Apex Basement Renovation 'Location: Warren County,New York Climate Zone: 8a Project Type: Alteration vertical Glazing/Well Area: 1°�0 Construction Site: Ownar/Agent: Designer/Contraotor: 64 Main St Stan Dobert Andrew Allison Queensbury,NY-12804 Apex Solar Power q)A Architecture Planning. 64 Maln'St 3 Broad Street Queensbury,NY 12804 2nd Floor (518)309-2786 work - (970)531• Glens Falls,NY 12801 7855 mobile (518).7924651 ext.161 mdobert@gmall.com oalllsoniipojaarchitecture.com. . Building Arita Floor area 1-Basement that has been finished to house offioes.(Office) 1885 Nonresidential Envelope Assemblies WValue Proposed Max.Allowed Post-Alteration Assembly Cavity, Cont. U-Factor SHOC.. U-Factor,. SHOC Basement Wall 1:-Solld Concrete:12"Thickness,Normal Density, 16.0 7.6- 0.046. -- 0.108 -- Furring:Wood,Wall Ht8.0,Depth_ B.G.6.0,(Bldg.Use 4, . Basement that has been finished to house offices.] Window 1:Vlnyl/Fiberglass.Frame,Clear,]Bldg.-Use 1- 0.490' -- 020 0.400. Basement that has been finished to house offices.) Flood:Slab-0n=Grade:Unheeted,(Bldg.:Use 1-Basement that 1.000 -- 0.660 has been finished to house offices.) Floor 2:Wood-Framed,1Bldg.Use 1:-Basement that has been 38.0 '0.0 0.026 •-- 0.033 — finished to house offices.] ExtetlorWell 1:Wood-Framed,IS"o.o.,[Bldg.Use 1-Basem6nt -- -- — that has been finished to house offioes.l,Exemption:Cavity filled . with minimum R-3/inch Insulation Door 1:Insulated Metal,Swinging,[Bldg:Use 1-Basement that has been finished to house.oHices.] Roof 1 c Attic Roof With Wood Joists,(Bldg.Use f-Basement that 0.0 0.0. 0.613 -- 0.027. •- haQ been finished to house offices:] (a)Fenestration product performance must be certilled In accordance with NFRC and requlrea supporting documentation. (b)Slab-On•Grade proposed and budget U-factors shown in table are F-factors. ,� ED ARC. tlr�>` Foy r��,v�, . Project Title: Apex Basement Renovation Report dater 02/16/16. Data filename: 5:11 AjA Architecture Projects\15114 APEX Solar RenvoationlAPEX BASEMENT COMCHECK.cck Page 1 of 16 I -61qpb FAILS Project Title:. Apex Basement Renovation Report date: 02/16/16 Data filename: S:\1 AJA Architecture Projects\15114 APEX Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 2 of 16 1 COMllcheck.Software Version 4.0.200 Interior Lighting Compliance Certificate Project Information Energy Code: 2014.New York Energy Conser..Constr.Code(by application-of 90.1 (2010)Standard) Project Title: Apex Basement Renovation Project Type: Alteration . Construction Site: Owner/Agent: Designer/Contractor. 64 Main St Stan Dobert Andrew Allison Queensbury, NY 12804 Apex Solar Power AJA Architecture&Planning, 64 Main.St 3 Broad Street _ Queensbury;NY 12804. 2nd Floor (518)309-2786.work - (970)591- Glens Falls,NY 12801 7855 mobile (SIB)792-1651-ext.101 mdobe'l@gmall.com. - aaII1son@a)aarchi1:ecture;e0m Allowed Interior Lighting Power A a C D Area Category Floor Area. Allowed. Allowed Watts (ft2) Watts 1 ft2 (B X C) 1-Common Space Types:Offica-Enclosed 92 1.11 102 2-Common Space Types:Office-Enclosed 92 .1.11 102 3-Common Space Types:Offce-Enclosed 90 i.11 100 4-Common Space_Types:Office-Enclosed 90 1.11 100 5-Common Space TypswMce-Enclosed 91 1_.11 101 . &Common Space Types:Office-Enclosed 91 I'll 101 7-Open Floor Cubicles(Common Space Types:Office-.Open Plan) 523 0..98 613 8-Unisex Bathroom.(Common Space.Types:Restrooms) 47 0.98 46 9-File storage(Common Space Types:Storage) 63 0.63 33 10-Enclosed exitsfairway(Common Space Types:Stairwey). 73 .0.69 6D 11-Break Room wl kitchenette(sink,fridge,counter,&storage.(Common Space 159 0.65. 103 Types:Dining Area-General) 12-Meeting Room(Common Space Types:ConferencelMeeting!Multipurpose). 179 1-,23 220 Totes Allowed Watts= 1572 Proposed Interior Lighting.Power A B C D E. Fixture ID:Description I Lamp I Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. . Common Space Tynes:Office-Enclosed:(92 sa.ft.l .LED 1:RECESSED LED CAN LIGHT:.Other. 1 2 8. 16 . LED 2:RECESSED LED CAN LIGHT:Other: 1 2 8 16 Common Space Tvnes:Office-Enclosed(9090 m4ft LED 3:RECESSED LED CAN LIGHT:Other 1 2 8 16 LED 4:RECESSED LED CAN LIGHT:Other. 1 .2 8 16 Common Space pes:Office-Enclosed(91 sq.ft.l LED Si RECESSED LED CAN LIGHT:Other. 1 2 8 16 LED 6:RECESSED LED CAN LIGHT;Other: 1 2 8 16 Project TlUe: Apex Basement Renovation Report date: 02/16/16 Data filename: S:\l AJA Architecture Projects\15114 APEX Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 3 of 16 A . B C D E. Fixture ID:Description!Lamp/Wattage Per Lamp!Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt: . opiin Floor cubicles'(Common Space Types:Of c -Open Plan 523 sq=fL,) LED.7:RECESSED LED CAN LIGHT:Other. 1 14 8 112 Unisex-Bathroom(Common Space Types:Restrooms 47 sq.fta Incandescent 10:3 ARM OVER-SINK FiXTURE:Incandescent 60W: .3 1 180 180 Compact Fluorescent 2:BATHROOM.VENT/LIGHT'COMBO:Other Electronic: 2 1 25.' 25 File storage f Common Space Tvnes:Storage_63 sq.ft.1 Compact Fluorescent.l:Other:Electronic: 1 3 18 64 . Enclosed exit stairway(Common Space Types:Stains+ay 7�; .ft.1 LED 8:RECESSED LED CAN LIGHT:Other. 1 4 8 32 Break Roomw/kltchenette(,sink:fridge coUnte.&sto agd(Common S hbb Tynes:Dining Area General-15g sn:ft.)) LED 9:RECESSED LED CAN LIGHT:Other. 1 .4 8 32 Meeting Room(Common-Space Tynes:Confeience/Meeting/Multipurpose 179 sa,ft.) LED 10:RECESSED LED CAN.LIGHT:Other: 1 4 8 . 32 . . Total Proposed Watts 563 Iriterior Lighting * . Interior Lighting Corno lance•Statement Compliance Statement: The proposed interior lighting alteration project.represented-ln this document is consistent with the . building plans,.specifications;and other calculations submitted with,this permit application.The proposed Interior'lighting systems have been designed.to meet the 90:1.(2010)Standard requirements in CoMcheck V&s.lon 4.02,0 and to comply with the mandatory requirements listed In the Inspection Checklist; Name-.Title Signature Date 00 (ZE D.q RC J. LO Project Title: Apex Basement Renovation Report date: 02/16/16 Data filename: SAI A)A Architecture Projects115114 APEX Solar RenvoationlAPEX BASEMENT COMCHECK.cck Page 4 of 16 'COMcheck Software Version 4.0.24-0 Mechanical Compliance Certificate Project Information Energy Code: 2014.New York Energy Conser.Constr.Code.(by application of 90.1 (2610)Standard). Project 170a: Apex Basement Renovation Location: Warren County,New York Climate Zone: 6a Project-Type:. Alteration . Construcdon Site: Owner/Agent: DesignedContractor. 64 Main St Stan Dobert. Andrew Allison Queensbury,NY 1.2804 Apex Solar Power AJA Architecture&Planning. 64 Main St 3 Broad Street Queensbury,NY 12804 2nd Ploor (518)309-2786 work = (970)531- Glens Palls,NY 12801 7855 mobile (518)792-1651 ext. 101 . mdobertogmail.com. aallison@ajaarchitecture.com Mechanical Systems List Quantity. System Type&Description 6 HVAC System 1 Split System Heat Pump Heating Mode Capacity=18 kBtuth, Proposed.Efficiency=10.60 HSPF,Required Efficiency=7.70 HSPP_ Cooling Mode:Capacity.=18.kBtu/h,. Proposed Efficiency=19.00 SEER;Required Efficiency=13.00 SEER Fan System: None SYSTEM.COMPLIANCE REQUIRED. Mechanical Compliance Statement Compliance Statement., The proposed mechanical-alteration project represented In this document Is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 90.1(2010)Standard requirements in COMcheck Version 4:0.2,0 and to comply with the mandatory requirements listed in the Inspection Checklist. Name-Title 5 gnature Date '(ARE D-ARC SEE _!Sp7F Dew IN CAS J.q44 �I .� SYsrE tV o'r 5 0 N.A 02879$.,, � Project Title: Apex Basement Renovation Report date; 02/16/16 _ Data filename: S:\1 AJA Architecture Projects\15114 APEX Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 5 of 16 -COMcheck. Software Version 4.0.2.0 Inspection Checklist Energy Code: 90.1 (2010) Standard Requirements:.100.0%0:were addressed directly In,the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user"certifies-that a code..requirement will be met and how that is documented,.or that an exception Is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided: section. # Plan Review Compl[es? Comments/Assumptions ."." . 4,2.2,5.4. Plans and/or specifications provide all ocomplies Requirement will be met. 3.1.1,5'7 information with which compliance ;❑Does Not [PR1]1 :can be determined for the building ❑Not Observable envelope and document where -exceptions to-the standard are :❑Not Applicable claimed., 4,12,6.4. :Plans,specifications,and/or ;Zcomplies- Requirement will be met, 4,2,1,6.7, calculations provide all Information ;❑Does Not 2 -with which.compliance.can.be _ [PR2]1 determined for the mechanical []Not Observable,, :systems andequipment.and !❑Not Applicable document where exceptions to the standard are claimed.Load calculations per acceptable englneering standards and handbooks. 4.2.2,8.4. .Plans,specifications,and/.or .-[:]Compiles Requirement will be met. calculations provide all information 'E]Ddds Not 2,8.7 with which compliance can beX z ❑Not Observable, "PtSTt�:$0'1'ic ti C1.'R,Cu"'cS [PR6] "determined for the electrical systems and equipment and document where ❑Not Applicable , V•5� D. exceptions are claimed.Feeder connectors sized in accordance with approved plans and branch circuits 1 sized for maximum drop of 3a/a. . 4:12,9.4.- Plans;specifications,and/or Zlcomplles. Requirement-will,be met. 4,9.7 calculations provide all Information UDoes Not [PR4]1 i with which compliance can be ❑Not Observable determined for the interior lighting and electrical systems and equipment ;❑Not Applicable ; and document where exceptions to :the standard are claimed.Information 1 provided should include interior 1 :Ilghttng power calculations,wattage of 'bulbs and ballasts,transformers.and i control devices. 6,72.4 `.Detailed instructions for HVAC '❑Complies 'Exception:Requirement does not apply. � [PR5]1 systems commissioning included on Does Not p,. ►SS o N N"b t S o-r ;the plans or specifications for projects ' >=50,000 ft2. ❑Not Observable: T,6DU 17Z a ❑Not Applicable Additional Comments/Assumptions: [_1 High Impact(Tier 1) 2 Medium Impact(Tier 2) T,3;Low Impact(Tier 3) Project Title: Apex Basement Renovation Report date: 02/16/16 Data filename: S:\i AJA Architecture Projects\15114 APEX'Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 6 of 16. Se ion °=Footing/Foundation 'Plans Verified Field Verified Inspection, Value Compiles? Comments/Assumptions 5.5.3.3 Below-grade wall insulation R- R- R- '❑Complies ,See the Envelope Assemblies [FO1]2 value; -❑Does Not table for values. QNot Observable i ❑Not Applicable 5.8.1.2 Below-grade wall insulation ;OComplies ,Requlrementwill be met, [FO21 Installed per manufacturer's ;Oboes Not. ,.S�AC-ELS.�ttu z p Instructions.. x fib;S��'`'E. ! ;PJNot Observable 5�� .Sg t . ;[J]Not Applicable V.VATa ' 1tM 5:5:3.5 `Slab edge insulation R-value. R= R ;OComplles see the:>_nvelopeAssemblies [FO3j1 - ❑ Unheated ❑ Unheated UDoes Not table for values. Heated ;.[]'Heated p�Not Observab Not Applicebf 5.8.1.2 -Slab.edge insulation Installed per; ;❑Complies �Requlrement will be met.- [F®4l2 manufacturer's Instructions. } rob, i "Rot Observa e ; -- Not Appllcab Slab edge Insulation ft ft ❑Complies see the'EnvelopeAssemblies [0O512 depth/length. - I Z]Does Not table for values, ®Not ObservabI []Not Applicabi 5.8.1.7.3 Insulation.In contact with the i '[]Complies. :Requirement will be met. [F07)1 -ground has.<-0.3%water ; ,[]Does Not absorption rate per ASTM'C272. f iMNot-Observable . ❑Not Applicable •Freeze protection and-snow/Ice f❑Complies Exceptions Requirement (FO3]3 melting,system sensors for future,' :❑D.oes Not does not apply. connection to controls. I QNot Observable te�. . �ialNot Applicable',' 6;4 4 1'S j Bottom surface of floor-stru-ctures R­ R-' '®Compiles Exception.Requirement IO1l�j3 !Incorporating radiant heating '❑Does Not does not apply.. Insulated to>-R-3.5.' 7 :®Not Observable See the Envelope Assemblies C QNotApplicable table.for values, Additional Comments/Assumptions: rl High-Impact(Tier 1) 2 Medium Impact(Tier 2) 3. Low Impact(Tier 3) . . Project Title: Apex Basement Renovation Report date: 02/10/10. Data filename: S:\1 AJA Architecture Projects\iM.4 APEX Solar'Renvoation\APEX BASEMENT COMCHECK.cck Page 7 of 16 section Plans Verified: Field Verified 0. Framing/Rough-In Inspection ;- Complies?: Comments%Assumptions, Value Value 5,4,y3,2 Factory-built fenestration and ❑Complies ;Requirement will be-met. rFI1111, doors are labeled as meeting air S ❑Does Not leakage requirements. ❑Not Observable Mot Applicable 5,4:3.4 1 Vestibules are installed where i .RComplies Requirement will be met, [FR4]. building entrances separate ! ❑Does Not conditioned space from the ! r exterior,and meet exterior .[]Not-Observable envelope requirements.Doors [ Not Applicable have self-closing devices,and are; >=7 ft apart. + 5.5.4.3a Vertical fenestration 0-Factor. U U. .-OComplies Does Not table fo Envelope oe Assemblies [FRB] ❑ MNot Observable ; ,❑Not.Applicable " 5.5.4,3b Skylight fenestration 11-Factor: . p p U- U- :C]Com Iles See the Envelop a Assemblies [FR9)1 ❑Does Not table for values. I ONot Observable 1 RNot Applicable 5.5.4.4.1 ;Vertical fenestration 5HGC value. 5HGC: : 5HGC: ;OComplies 'See the Envelope Assemblies [FR10)1 : ❑Does Not 'table for values, �VNot.Observable [Not Applicable 5,5,4.4.2. Skylight SHGC value. ? SHGC: 5HGC: '❑Complies See the Envelope Assemblies [FR11]1 . ]Does Not table for values. :❑Not Observable. NNot Appilcable 5.8,2,1 Fenestration products rated In ][]Complies i Requirement will be met. [FR12)2 accordance with NFRC; f :,❑Does Not . Not Observable I :[]Not Applicable 5.8.2.2 Fenestration products are ❑Compiles .:Exception:The Installer or . [FR13)1 certified as to performance labels; .'[]Does Not supplier has provided. or certificates provided, certification listing U-factor, , ,®Not Observable .5HGC,and air leakage rate. + :ONot Applicable 5.8.2.3,5. U-factor of opaque doors U- 1 U- UComplles ;See the Envelope Assemblies 5.3,6 associated with the building ❑ Swinging ❑ swinging .❑Does Not :table for values. JFR1412 thermal envelope meets ❑ Nonswinging. ;Q Nonswinging. i1�iVot Observable requirements. ❑Not Applicable 5.4,31 :Continuous alr barrier Is : ,OComplles ;Exception: Requirement [FR1511 wrapped,sealed,caulked, 131)oee Not does not apply. gasketed,and/or taped In an approved manner,except In j `P[Not Observable I semlheated spaces and in `❑Not Applicable :climate zones 1-6. Additional Comments/Assumptions: r11High Impact(Tier 1) 2 Medium,Impact(Tier.2) 31Low impact(Tier 3) . Project Title:. Apex Basement Renovation Report date: 02/16/16 Data filename: S:\i AJA Architecture Projects\15114 APEX Solar RenvoatlonWPEX BASEMENT COMCHECK.cck Page 8 of 16 Section Mechanlcel Rough-ln Plans Verified Field Verified complleis? . Comments/Assumptions Re .ID inspection Value. . Value 6.4.1.4,6. 'HVAC equipment efficiency Efficiency: a Efticlency-I& ,Complies See the Mechanical Systems list 4.1.5 verified.Non-NAECA HVAC I ❑ for values. [MEl]2 :equipment labeled as meeting Does Not W i``LAgy DA 5r:V) :❑Not Observable :[]Not ApplicableP' 6.43,41 <Stair and elevator shaft vents :❑Complies '(Exception:Requirement [M3I3 'have motorized dampers that i❑Does Not does not apply. automatically'close. } :❑Not Observable ;XNot Applicable Outdoor air and exhaust systemsrClComplies :Requirement will be met: 6 4 3,4:3 k have motorized dampers that ':[],Does Not L)Pr r MACS [ME4j3 ;-automatically shut when not in ❑Not Observable ` htpTo X 126 1 use and meet maximum leakage i ;❑Not Applicable rates.Check.gravlty dampers ppr 4,where allowed. i ;643:4.5 !Enclosed parking garage :❑Complies .Exception:Requirement C ventilation has automatic "[]Does Not does not apply,ME'39j3 contaminant detection and capacity to stage or modulate .-[]Not Observable s-fans-to 50%or less of design Not Applicable _ `•capacity. ;6;4z=3 4':4, ,Ventilation fans>0,75 hp have 1 k❑complies Requirement will be met. automatic controls to shut off fan.; , Does Not cor✓trto"I D vi A. when not required. f. ❑Not,Observable.; Au-7 p >~(a.�c2uct1 ❑Not Applicable CC)"- 'Rol_l..K _ — 6.4.3.9 -Demand control ventilation !❑Complies Exception:Systems with a [ME6I1 provided for spaces>506 ft2 and ❑Does Not design outdoor airflow less >40 people/1000 ft2 occupant 1. , Ethan 1200 cfm. .density and served by systems ❑Not Observable with air side economizer,auto + it Not Applicable EG b -►-a v chf modulating outside air damper r C oJutRot_ ob�Ar control,or design airflow>3,000 �P)F WIZUN7 M 0 D A—.S cfm. 6.4.3.10 Single zone HVAC systems with ! l❑Complies - Exception:Requirement [ME4012 :fan motors>=5 hp have variable:; ❑Does Not does at apply. airflow controls.Air conditioning15 fFLO N k U N t equipment with a.cooling < ?❑Not Observable -See the Mechanical Systems list capacity>=110,000 Btu/h has ? of Applicable for values. _ variable airflow controls, V6 4 41,-1__ Insulation exposed to weather ' ❑Complies Requirement will be met. [iN6y+) i protected from damage. Oboes Not Insulation outside of the ;,MNot Observable ! l conditioned space and associated; ❑Not Applicable with cooling systems Is vapor pp retardant: 6.4.4.1.2 'HVAC ducts and plenums R- R• ;❑Compiles Exception: Ducts/plenums [ME812 insulated.Where ducts or '❑hoes Not located in heated,semi- plenums are installed In or under ; I []Not Observable ;heated,or cooled spaces, a slab,verification may need to occur during Foundation ; Not Applicable Inspection, .6.4.4.1.3 HVAC piping Insulation thickness. ; in. In. •❑Complies .Requirement will be met. [ME912 Where piping Is.installed in or :[]Does Not ; under a slab,verification.may need to occur during Foundation ❑NoC Observable Inspection. JEW Applicable '6 4,T'.4 Thermally ineffective panel ❑Compiles Exception:Requirement [ME41j surfaces of sensible heating ❑Does Not :does not apply. 3 panels have insulation>=R=3.5. i '❑Not Observable I RNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3,; Low Impact(Tier 3)�� Project Title: Apex Basement Renovation Report date: 02/16/16 Data filename: S:\3 AJA Architecture Projects\15114 APEX Solar RenvdatIon\APEX BASEMENT COMCHECK.cck Page 9 of 16 Section Mechanical 12'ough-ln Plans Verified Field Verified , #. Complies. . Comments/Assumptions &.Re .ID lnspectlon Value: . Value . 6.4.4.2.1 Ducts and plenums sealed based.r ;❑Complies .Requirement will be met. [ME16]2 'on static pressure.and location. UDoes Not ❑Not Observable ; ❑Not Applicable 6 4 4J.2 i Ductwork operating>3 In,water ❑Complies Exception:Requirement [ME11 1 column requires air leakage I i❑Does Not -does not apply. testing. ;❑Not Observable ; Not Applicable 6 5,2 3 Dehumidification controls ; _ ElComplies. Exception,Cooling capacity [ME19,1 provided to prevent reheating,. , ' Does Not !40 kBtu/h. I recooling,mixing of hot and cold ? ST aN�Ax o 5Y5T airstreams or,concurrent heating ; :❑Not Observable ; �,5 and cooling of the same 3 Not Applicable , I Kw iJCe airstream; 5.5 3 3 Multiple zone VAV systems with ❑Complies 'Exception:Requirement [ME42] DbC of Individual zone boxes ;❑Does Not does notapply. !have static pressure setpoint b reset controls. i [3Not Observable See the Mechanical Systems list `ONot Applicable for values.. :6 5 4 1 . HVAC pumping systems>10 hp f C1Complies Requirement will be met. M25j designed for variable fluid flow. s :❑Does Not NJ ❑Not Observable .EgNot Applicable 6.5.6.1 i Exhaust air energy recovery on ❑Complies ,Exception:Requirement IME5611 :systems meeting Table 6,5,6,1. Z]Does Not does not apply, []Not Observable f ,®Not Applicable 6.5.7.1.1 •Kitchen hoods>5,006 cfm have v i❑Complies Exception:Requirement [ME32]2 make up air>=50Wof exhaust r❑Does Not: :does not apply, air volume. []Not Observable Jallot Applicable 646 7 1.5 Approved field test used to_ i � ;❑Complies Exception:Requirement [P� 49j evaluate design airflow rates 1❑Does Not :does not.apply.' and demonstrate proper capture r and containment of kitchen i ❑Not Observable i exhaust systems, i QNot Applicable 6.5.7.2 Fume hoods exhaust systems 'E Complles Exception:Requirement IME3331 >=15,000 cfm have VAV hood `❑Does Not does not apply. exhaust and supply systems, i ',❑Not Observable direct make-up air,or heat 'recovery, I®NotApplicable :6.518.1 Unenclosed spaces that are ;,❑Complles Exception:Requirement [ME34]2 heated use only radiant heat. ![:]Does Not does not apply, ❑Not Observable ',Not Applicable. Additional Comments/Assumptions: 1 Hlgh Impact Merl) 2 Medlum Impact(Tier 2) 3,_�Low Impact(Tier 3) �� Project Title: Apex Basement Renovation Report date: 02/16/16 Data filename: S:\1 AIA Architecture Projects\15114 APEX Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 10 of 16 Section Rough-In Electrical Inspectlon. Complies? Comments/Assumptions & Re .Ib . 8.4.2 ,At least 50%of all 125 volt 15-and "[]Complies' Requirement:Requirement will be met. [EL10]2 :.20-Amp receptacles_are controlled by 13Does Not an automatic control device. ❑Not Observable ®Not Applicable. 9.4.1.1 Automatic controls to shut off all []Complies Requirement will be met. [EL112 building lighting, ':[]Does Not ❑Not Observable 19Not Applicable 9.4.1.2 Independent lighting controls Installed-5aComplies- Requirement.will be met. CEl 2]Z ;per approved lighting plans and all ❑Does Not manual controls readily accesslble'and;©Not Observable visible to occupants, _ ❑Not Applicable 9.4,1.3 Parking garage lighting Is equipped '"❑Complies Exception: Requirement does not apply, CEL1112 with required ilghting controls and lJDoes Not daylight transition zone lighting, ❑Not Observable .:LiNot Applicable . 9.4.1.4 ,Primary sidelighted areas>r4-;250 ft2 ❑Complies Exception: Requirement does not apply. [EL12]1 are equipped with required lighting - . t❑Does Not controls. ❑Not Observable-: ' Not Applicable , 9.4.1,5 'Enclosed spaces with daylight area -❑Complies Exception: Requirement does not apply. [EL1311 under skylights and rooftop monitors '[]Does Not >900 ft2 are equipped with required Observable . lighting controls, ..,[]NotVNot Applicable 1 9,4.1,E Separate lighting control devices for ❑Complies• Re-qulrement will be met. [ELO - specific uses Installed per approved ❑Does Not lighting plans, ❑Not observable ; Not Applicable- i 9.4.2 Exit signs do not exceed 5 watts per, •RComplies :Requirement will be met. [EL6]1 face. lboes Not. ❑Not Observable .'❑Not Applicable 9.6.2 :Additional Interior.lighting power ❑Compiles Requirement will be met, [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and {?Not Observable: tseparatedfrom.generallighting, W Not Applicable 10.4.1 Electric:motors meet.requirements ,❑Complies Requirement will be met, [EL9]2 where applicable, 13Does Not ❑Not Observable' WNot Applicable i. Additional Comments/Assumptions: 1 High .impact(Tier 1) 12 1 Medium Impact(Tier 2) _�3' Low Impact(Tier 3) Project Title: Apex Basement Renovation Report date: 02/16/16 Data filename: S:\1 AAA Architecture Projects\15114 APEX Solar Renvmdon\APEX BASEMENT COMCHECK.cck Page 11 of 16 Section Plans-Verified Ole ld l/erified: # - Insulationdnspection Complies. Comments/Assumptions &.Re :ID Value -Value 5.43.1. !All sources of air leakage in the `❑Complies Requirement will be met. [IN111 building thermal envelope are Does Not sealed,caulked,gasketed, _ ; Not Observable weather stripped or wrapped.with, i moisture vapor-permeable. ❑Not Applicable. wrapping-material to minimize airs leakage. 5.5.3.1 Roof R-value,For some ceiling R- ; R- ❑Complies See the Envelope Assemblies [IN211 systems;verification may need to:❑_Above deck :E Above deck :❑Does Not :table for values occur during Framing Inspection, ❑ Metal ❑ Metal ;❑Not Observable. [] Attic ;❑ Attic QNot Applicable 5.8,1.2,5..!Roof insulation installed per t.❑Compiles. Requirement will be met, 8.1.3 manufacturer's instructions; ;❑hoes Not [IN311 Blown or poured loosd4iil insulation Is Installed only where' ❑Not Observable. . :the roof slope is<=3 in 12. oNot Appllcable ; 5.5.3,2 Above-grade wall.insulation R R- R- ,'❑Complies See the Envelope Assemblies [IN611 value.. ❑ Mass. ❑..Mass :❑hoes Not table for values. ❑ Metal ;❑ Metal Mot Observable ❑-Steel [J steel ;❑Not Applicable ❑ Wood ;❑ Wood 5,8:1.2 Above-grade wall insulation. i 12complies "Requirement will be met, [IN7]1 :instal►ed per manufacturer's.. $ ❑Does Not Instructions, ;0rNot Observable _ QNot Applicable 5.5,3.4 :Floor insulation R-value, ❑Compiles :See the Envelope Assemblies [IN812 ❑.Mass ❑.Mass Does Not - :table for values. ❑ Steel ❑ Steel ,RNot Observable ; ❑ Wood- ❑ Wood :❑Not Applicable 5',81.2 Floor insulation Installed per- ❑Complies Requirement will be met, [IN9)2 manufacturer's Instructions. ❑Does Not ?RNot Observable f ;UNot Applicable, 5.9.1.1 ;Building envelope Insulation Is r o0Complies Requirement will be met, [IN1012 :labeled with R-value'or Insulation ❑boas Not i certificate providing R-value and l other-relevant data. ' ❑Not Observable UNot Applicable 5.8.1.4 Eaves are baffled to deflect air to :❑Complies ;Requirement will be met. IIN1112 above the insulation. ❑Does Not of Observable i + of Applicable 5;8.1.5 insulation.is installed in ❑Complies ' Requirement will be met, [IN1212 substantial contact.with the ❑Does Not inside surface separating ; conditioned,space from iNOC Observable I unconditional space. ;❑Not Applicable 5.8:1.6 Recessed.equipment installed in `r ❑Compiles Requirement will be met,. (IN1312 building envelope assemblies ❑Does Not does not compress.the adjacent. ; Not Observable insulation. . ; 113Not Applicable , 1 High.lmpact(Tier 1) 2 Medium Impact(Ter 2) ;3.Low Impact(Tier 3) Project Title: Apex Basement Renovation Report date: 02/16/16 Data filename: SAI AJA Architecture Projects115114 APEX Solar RenvoationWPEX BASEMENT COMCHECK•cck Page 12 of 16 section Plans Verified Field Verified insulation Inspection Compltes?,., . ,Comments/Assumptions &;Re a1D Value Value 5.8,1.7 Exterior insulation is protected ;❑Complies s Requirement will be met. [IN34]2 from damage with a protective I❑Does Not material.Verification for exposed foundation Insulation may need i ;®Not Observable to occur during Foundation" JRNot Applicable. Inspection. y 5.8.1.7.1 Attics and mechanical rooms ❑Complies :Requirement will be met. [IN15]2 :have Insulation protected where 4 T❑Does Not adjacent to attic or equipment Not Observable access. { j Not Applicable 5.8.1.7.2 Foundation vents do'not Interfere! fL]Complies. :'Requirement will be met. [IN16]2 with insulation. i #.❑Does Not i i ?❑Not observable l allot Applicable -50 1 8; Insulation Intended to meet the ( ❑Complies Requirement will be met. (lldi7]�: roof insulation requirements i i❑l)oes Not cannot be Installed on top of a I suspended ceiling.Mark this 1 [:]Not Observable requirement compliant If ANot Applicable Insulation is Installed accordingly,! { Additional Comments/Assumptions: 1 High.lmpact(Tier 1) 2 Medium Impact(Tier.2) lTLow Impact(Tier 3) Project Title: Apex Basement Renovation Report date: O iWi6 Data filename: S:\1 AjA Architecture Projects\15114 APEX Solar Renvoation\APEX BASEMENT CONICHECK.cck Page 13 of 16 Section Finallnspectlon I Complies? Comments/Assumptions :.&ROAD, 5 A3.3 . Weatherseals installed on all loading Uco'mplies ,Exception:Requirement does notapply. [FI1]1 dock cargo doors in Climate Zones 4-. !❑Does Not g :❑Not Observable <G?Not Applicable i.Thermostatic_ controls have a 5°F ❑Complies Exception:Thermostats requiring manual changeover [FI3)3 'deadband. []Does Not ;between heating and cooling. '❑Not Observable a ; Not Applicable ; .;Temperature controls have setpoint :OCompiles Requirement will be met., [F120j3 i-overlap restrictions, ❑Does Not ❑NotObservable ZNot Applicable {HVAC systems equipped with at.least ;iRComplles Requirement will be met, ' one automatic shutdown control. ;0Does Not ❑Not Observable _ ?❑Not Applicable 624 3 3 2 i Setback controls allow automatic ❑Complies -Requuir mentwill be met. iFi22]3 11 restart and temporary operation as :❑Does Not uGt{ d&V' X --F-6 required for maintenance. '❑Not Observable MA$b.k ONot Applicable t. 6 4,35 Heat pump controls prevent :❑Complies Requirement will be met, supplemental electrlc'reslstance heat ❑Does'-Not D�cr 5 -1- 'To #^14.1 ETA from coming on when not needed. P []Not Observable V-V-_Ps ai A t[L. '1JNot Applicable 1K i f.�i t:;. 5 tr'.A p KV 1�' When humidification and ❑Complies Requirement will be met,. dehumidification are provided to a ;❑Does Not ji Rv N zone,simultaneous operation Is prohibited: '❑Not Observable I NDJr'��M? ❑Not Applicable ; )U . L,6 i7 t F N Furnished.HVAC as-bullt drawings ❑Complies Requirement will be met, [Fal7]3 submitted within 90.days of system ❑Does Not acceptance. [Not Observable ❑Not Applicable 6 77'2.2 Furnished 0&M manuals for HVAC ❑Compiles Requirement will be met, systems within 90 days of system ;❑Does Not pjzONA DEcD c..l .�(,;.w i P f--e✓wT / acceptance. :❑Not Observable C o'P 1 rS U Po vj.'9EPV E 61 i❑Not Applicable ; 6.7.2.3 An air and/or hydronlc system °❑Compiles 'Exception:Requirement does not apply, [FI9]1 balancing report is provided for HVAC ;❑Does Not ;systems serving zones>5,000 ft2 of : conditioned area, [:]Not Observable ❑Not'Applicable 6.7.2.4 HVAC control systems_have been ❑Compiles Requirement will be met. [FI10]1 tested to ensure.proper operation, ❑Does Not 5�}{ c.� . W.��t .p,Rp v i Pa 5-AWT up callbrat Ion and adjustment of controls;` Not Observable :QNotApplicable 8'7 Furnished as-built drawings for .❑Complies s Requirement will be met. �[FI16j3 electric power systems within 30 days ![]Does Not of system acceptance. ;❑Not Observable! , UNot Applicable , ; :_ 2 i Furnished O&M instructions for UlComplies Requirement will be met. P ;❑ t I systems and equipment to the Does Not building owner or designated representative, gNot Observable' iNot Applicable 1 High.Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ~� Project Title; Apex Basement Renovation Report date: 02/16/16 Data filename: S:\1 AJA Architecture Projects\15114 APEX Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 14 of 16 C ,Section." #.,: Finallnspection Complies? Comments/Assumptions' .&Re .ID 9:2,2:3 'Interior installed lamp and fixture L�"Complles .See the Interior Ughting fixture schedule for values. IFI1811 . _'lighting power is consistent with what UDoes Not Is shown on the approved lighting plans,demonstrating proposed watts ;[]Nof Observable: are less than or equal to allowed UNot Applicable i watts. ; '10.4:3 Elevators are designed.with the ;OCompiles Exception:Requirement does not apply: [FI24]2 proper Ilghting,.ventilation power,-and UDoeS Not standby mode. 3Not Observable ji�Not Applicable Additional Comments/Assumptions:, �1 High Impact(Tier 1) 2 Medium Impact(Tier 2) Ti-Ti-ow impact(Tier 3)� Project Title: Apex Basement Renovation Report.date: '02/16/16 Data filename: S:\1 A]A Architecture Projects\151,14 APEX Solar Renvoation\APEX BASEMENT COMCHECK.cck Page 15 of 16 Project Title: Apex Basement Renovation Report date:.02/16/16 Data filename: SAI AJA Architecture Projects115114 APEX Solar Renvoatlon\APEX BASEMENT COMCHECK,cck Page 16 of 16 s � PLAN REVIEW CHECKLIST Non-Residential Occupancies March 2010 NYS BUILDING CODE(BC) Building: A e NYS FIRE CODE(FC) Location: fi NYS PLUMBING CODE(PC) Address: NYS MECHANICAL CODE(MC) NYS FUEL GAS CODE(FGC) Date: /�3 /f- NYS ENERGY CODE(ECC) Reviewer: THIS CHECKLIST CONSISTS OF PAGES LEGEND: NR=Not Required NS=Not Shown NA=Not Applicable No. Topic Code Page Required Actual Section No. or Allowed 1 jurisdiction BC-101.2 1 2 Flood Plain BC-1612 287 3 Separated or Non-Separated BC-302.3 18 Occupancies* 4 Occupancy BC-302 17 5 Type of Construction BC-Table 601 77 6 No.of Sleeping Units/Level BC-202 13 No.of Units-Total BC-310 30 No.of Occupants BC-Table 1004.1.2 189 7 Covered Malls BC-402 33 Hi-Rise (75'Rule) BC-403 35 Atriums BC-404 37 8. Basement Definition BC-502.1 67 9 Heights&r Building Areas Maximum Tabular Area BC-Table 503 68 Maximum Tabular Height BC-Table 503 68 Maximum Stories BC-Table 503 68 Mezzanines BC-505 69 Note: *Non-separated occupancies impose the most restrictive requirements Page 1 of 8 Required Actual No. Topic Code Page Section No. or Allowed 10 Sprinkler System BC-903 160 Basement Sprinkler BC-903.2.10.1 161 Water Source Sprinkler BC-903.3.5 163 Water Source Site BC-508.1 33 11. Frontage use Sprinkler Credit Area Modifications(calc.) BC-506 70 Height Modifications BC-504 69 12. Height&Area Summary: Tabular Area BC-Table 503 68 Frontage Credit BC-506.2 70 Sprinkler Credit BC-506.3 70 Minimum Building Area BC-506.3 70 Total Allowable Area 13. Fire Apparatus Road FC-503.1 31 150'rule 14. Exterior Walls Distance Separation* BC-Table 602 77 Exterior Wall Openings BC-Table 704.8 82 Parapets BC-Table 704.11 83 Exterior Wall Coverings BC-Table 1405.2 241 Combustible Exterior Walls BC-1406 244 15. Fire Rated Construction incidental Use Areas BC-Table 302.1.1 17 Accessory Occupancy BC-Table 302.2 18 Mixed Occupancy BC-Table 302.3.3 19 Fire Walls BC-705 84 Fire Barrier BC-706 86 Shaft Enclosure BC-707 87 Fire Partition(Tenant Sep.) BC-708 89 Exception BC-302.3.2 18 Smoke Barriers BC-709 90 Opening Protectives BC Table 715.3 95 Fire Blocking BC-717 101 Draft Stopping BC-717 102 16. Space Min.Room Dimensions BC-1208.1 235 Min.Ceiling Height BC-1208.1 235 Distance separations are doubled if fire fighting water is not available,FC-508,Page 33 Page 2 of 8 cm r �.q � � No. Topic Code Page Required Actual Section No. or Allowed _ -- 17. Ventilation Nat.or Mech. BC-1203 233 L 18. Light Nat.or Mech. BC-1205 234 19. Exits 2°d exit to legal open space ,�! \ One Exit Permitted BC-Table 1014.1 204 Stair Enclosure BC-1019.1 208 Emergency Egress BC-1025 217 �\ Distance of Travel BC-Table 1015.1 206 Exit Passageways BC-1020 210 v�ith�` Corridor Width BC-1016 206 Occupant Load BC-1004 189 Capacity of Exits(calc.) BC-Table 1005.1 190 Corridor Wall Fire Rating BC-Table 1016.1 206 Corridor Dead End BC-1016.3 207 Door Width/Canopies Over Required BC-1008.1.1 193 Exits BC-1008.1.2 193- / Door Swing BC-1008.1.9 197 / Panic Hardware ddd _ 20. Stairs Riser BC-1009.3 198 Tread BC-1009.3 .198 Width BC-1009.1 198 Headroom BC-1009.2 198 Vertical Rise BC-1009.6 199 / Handrails BC 1009.4 199 �( 21. Structural Snow Loading—Ground BC Fig 1608.2 274 Snow Loading—Roof(calc.) ASCE 7-98 Drifting Snow BC-1608-7 273 Ponding - BC-1608.3.5 273 Floor Loading BC.Table 1607.1 269 Balcony Loading BC-Table 1607.1 269 Wind Loading(calc.) BC-1609 273, Roof Walls Windows Seismic Loading(calc.) 291 Foundation Depth 338 Page 3 of 8 Y No. Topic Code Page, Required Actual Section No. or Allowed 22. Interior Finishes BC-Table 803.5 338 23. Swimming Pools BC-3109 532 24. Sun Rooms BC Appendix I 581 25. Electrical Exit Signs BC-1011 201 Emergency Lights BC-1006 191 Exterior Emergency Lights Emergency Power BC-2702 517 26. HC-ACCESS Exempt Buildings BC-1104.4 221 Parking BC-Table 1106.1 222 Route BC-1104 220 � Entrance BC-1105 221 No.of Sleeping Rooms BC-Table 1107.6.1.1 224 0Zh S No.of Dwelling Units BC-1107.6 . 223 Special Occupancies BC-1108 225 Toilet Facilities BC-1109.2 228 Sinks BC-1109.3 228 ei-V Kitchens BC-1109.4 229 Storage BC-1109.8 229 Dress,Fit,Locker Rms. BC-1109.12.2 229 Point of Sales BC-1009-12.3 229 Areas of Refuge BC-1107.6 192 Signage BC-1110 230 Tactile Exit Signs BC-1011.3 202 Supplemental HC Re 'mts Appendix E 569 27. SPECIAL INSPECTIONS BC-1704 318 28. Fire Protection Equipment Fire Safety&z Evacuation FC-404 25 Hazard Communication FC-407.5 27 Tenant Identification FC-408.11.2 30 High Piled Storage FC-503.1.3 31 �\ Premise Identification FC-505 32 KeyBox FC-506 33 Room Identification FC-510 34 Central Station Monitoring FC-901.9 54 Sprinkler Systems - FC-903 57 Other Extinguishing Syst. FC-904 61 Kitchen Hood Extinguisher FC-610.3 43 Note: Fire Protection Equipment continued on Page 5. Page 4 of 8 No. Topic Code Page Section No. 28. Fire Protection Equipment Continued from Page 4 "K-Extinguisher FC-904.11.5 64 Standpipe Systems FC-905 64 Fire Extinguishers FC-906 66 Fire Alarm Systems&s SD FC-907.2 .68 Manual Fire Alarm Boxes FC-907.4 75 Smoke Alarms FC-907.2.10 70 Audible Notification Device FC-907.10 75 Duct Detectors FC-907.12 76 Fire Extinguishing Systems FC-907.14 76 Smoke Control FC-909 77 Smoke Vents FC-910 84 Fire Dept.Connection FC-912 88 Fire Pumps FC-913 88 Truss Placards NYCRR Part 1264 Motor Fuel Disp.Facilities FC-2203 175 High Piled Storage FC-2301 193 Hazardous Materials FC-2701 215 Operating Permits TOCP 208-107B Assistive Listening Devices NYCRR Part 1203 Shield Electrical Panels NFPA13 (02 edition) Attic Access or Crawl Spice 29. PLUMBING CODE Floor Drains for Bathroom,Laundry,Mechanical Room Cleanouts Plumbing Schematic PC-Table 403.1 19, Fixture Count Water Supply PC-603.1 31 Service Pipe Size- PC-603.2 31 Water/Sewer_Separation PC-Table 604.5 33 Fixture Pipe Size PC-Table 605.3 34 Pipe Material—Service P&Table 605.4 34 Pipe Material—Distribution EC-804.5 58 Pipe Insulation PC-Table 608.1 40 Backflow Prevention PC-305.6 12 Pipe Freezing Sanitary Drainage PC-Table 709.1 52 Drain Pipe Size Drain Pipe Material - PC-Table 702.1 46 AG Drainage&r Vent PC-Table 702.2 46 UG Drainage&t Vent PC-Table 702.3 Building Sewer PC-Table 910.4 63 Vent size Page 5 of 8 Y T , No. Topic Code Page Required Actual Section No. Or Allowed 29. Plumbing Code Continued from Page 5 Pipe Hangers PC-Table 308.5 15 Air Admittance Valves PC-917 66 T Mechanical Code - Ventilation'Rates MC-Table403.3 26 Dryer Exhaust MC-504 36 Kitchen Exhaust MC-506 37 Kitchen Hoods MC-507 40 Kitchen Make-Up Air MC-508 42 Air Plenums MC-602 51 Duct Construction MC-603 52 Duct Insulation MC-604 53 Smoke Duct Detectors MC-606 54 Fire&s Smoke Dampers MC-607.5.1 55 Combustion Air MC-701 59 31_ Fuel Gas Code Appliance Location FGC-303 16 Combustion Air FGC-304 16 Accessed Service . FGC-306 20 Clearance to Combust. FGC-Table 308.2 22 Pipe Material FGC-403 57 Shut Off Valves FGC-409 62 Chimney Termination FGC-Fig.503.5.4 68 Clothes Dryer Exhaust FGC-614 108 32. EnerUode Pipe Insulation-Heating EC-803.3.7 57 Duct Insulation-Sealing EC-803.28 46 Pipe Insulation-Hot Water EC-804.5 58 HWH Heat Trap EC-804.4 58 Climate Zone EC-Table 301.1 9 NYS COMcheck Compliance Report Computer Software Envelope Required Mechanical Lighting, 32. Elevator&z Conveyer Sys. Hoist Enclosures BC-3002.1 525 Emergency Signs BC-3002.3 252 Hoistway Venting BC-3004 526 Machine Rooms BC-3006 526 Shunt Trip BC-3006.5 527 Plumbing System BC-3006.6 527 Page 6 of 8 PLAN REVIEW CHECKLIST CONTINUED SEISMIC REVIEW SUMMARY ITEM Value BCNYS BCNYS Code Section Page No. Site Class Table 1615.1.1 295 (default to site-class D) Section 1615.1.1 292 S.(short period) Figure 16150) 293- S,(1 second period) Figure 1615(2) 294 F.(site coefficient-short) Table 1615.1.2(t) 296 F,(site coefficient-1 sec.) Table 1615.1.2(2) 296 S.(short period adjusted) Equation 16-38 292 Sma(1 sea period adjusted) Equation 16-39 292 SDs(short period)' Equation 1640 292 SDI(1 sec. period) Equation 16-41 292 Seismic Use Group Table 1604.5 266 Seismic Design Category Table.1616.3(i) 299 (short period) Seismic Design Category Table 16163(2) 299 (1 sec. period) Seismic Design Category This category determines the (most severe of above two) Design analysis and whether MEP systems must be braced Analysis Procedure Used Section.1616.6 300 Building Components Section 1621 315 Subject To Seismic Design Requirements: Architectural Section 1621.1.2 315 Mechanical Section 1621.1.3 315 Plumbing Section 1621.1.3 315 Electrical Section 1621.1:3 315 Page 7 of 8 PLAN REVIEW CHECKLIST CONTINUED NOTES FOR PREVIOUS REVIEW PAGES r y -Y Page 8 of 8 Aug. 4, 2016 9: 16A4MDIA No. 3571 P. 4/6 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. 'e.W.e*that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date f noted below and is issued subject to the following conditions. Owner: Apex Solar Date: 07/22/2016 Occupant:Basement Locatio 64 Main St Occupancy on-Residential R1ueensbury,Warren Co. NY Applicant: Apex Solar Power 64 Main Street Queensbury, NY 12804 L J Joseph A.Holmes No. 145778202866EL Equipment: 12-Switches; 54-Receptacles; 36-Fixtures; 3 -Smoke Detectors; 5-Mini Splits; 2-Exit/Emergency Combos; 1 - 500 KW Electric Heater;2-1000 KW Electric Heaters This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and above and the Installation inspected as of the above noted date based on a visual ownership as indicated herein, upon a change to the use,occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,effi- of tha property Indicated above,this certificate shall be immediately null and void. ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes Invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon rainspectlon by Middle Department system to which this certificate applies be altered In arty way.including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency. Inc.to Initiate the inspection and revalldation any of the components installed as of the above noted date,this certificate shall be process. A tee will be Charged for this Service. GC" V� a