Loading...
2012-209 tl-POI kl I I I II TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120209 Date Issued: Tuesday, January 08, 2013 This is to certify that work requested to be done as shown by Permit Number P20120209 has been completed. Location: 93 ROUND POND Rd Tax Map Number: 523400-296-005-0001-012-000-0000 Owner: GUIDO PASSARELLI Applicant: GUIDO PASSARELLI This structure may be occupied as a: Fireplace By Order of Town Board Garage Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. -O./4 TOWN OF QUEENSBURY 742 Bay Road,Quccnsbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120209 Application Number: A20120209 Tax Map No: 523400-296-005-0001-012-000-0000 Permission is hereby granted to: GUIDO PASSARELLI For property located at: ROUND POND Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GUIDO PASSARELLI Fireplace 2955 VETERANS Rd W Suite 2B Garage Attached STATEN ISLAND,NY 10309-0000 Single Family Dwelling Total Value Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2012-209 SFD 2,816 sq ft 2 car attached garage $635.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, May 21,2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ue bury; on• , � a 21, 2012 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement i I '! Revised 4/14/2010 Town of Queensbury Highway Lf RAI` G 8 2012 Michael F. Travis Department Highway Superintendent 742 Bay Road, Queensbury, NY 12804 L. �.i,' `_ Home (518) 798-0413 LUIi.iJ ^1: ^F L Office Phone: (518) 761-8211 Thomas R. Vanness Fax: (518) 745-4466 o1.O l 3-")-te")- Deputy Superintendent Home (518) 745-0929 www. Queensbury.net DRIVEWAY PERMIT � Date: /eJ d,'/ Applicant Name: �� Address to be inspected: 4-6 S d / R0 u h eo Return Address: a91f v� (413 c Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location_ The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: Step 1: ( ) Preliminary Approval Need: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( )15" ( ) 18" ( )24" ( )36" Preliminary inspections completed by: Date: Approved by Higway Supt: Deputy Supt.: Upon completion, please resubmit this approved permit for a final approval. Step 2: ( ) Final Approval ( ) Rejected Date: Michael F. Travis, Highway Superintendent Thomas R. Van Ness, Deputy Highway Superintendent Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 5 w r �y[ OFFICE USE ONLY q TAX MAP NO. 9 5-1.-_I_� ,__..__-_.----.-PERMIT NO. / a_._..,( .•vaQ 9 • FEES: PERMIT ` 3 d-' RECREATION ,0 --ENGINEERING_ _ __ f Si) fr- (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: - c,ic-1 c..) R. 5 C• `P '! , OWNER: /` /2 A/yr/ ,,_,'. Op ft; ou A. ADDRESSC: CT S z) (--42.1` 8n, R(i 4.,k,, - s ADDRESS: -1-$51'3z.1^ /5i?Y1 a )14o wD .I� / O'. PHONE NOS. q, ') 6 c) 2a Cr 3f PHONE NOS. j CONTACT PERSON FOR BUILDING&CODES COMPLIANC ; ,\ r/ L ,t1or\---PHONE:_ j 7 — 7_ LOCATION OF PROPERTY: fS/� 3 �� PDviec 1 HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? J YES 0 NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: ‘ ' d - ---? PLEASE INDICATE MEASUREMENTS AS REWIRED-BELOW: CHECK ALL THAT z APPLY TO YOUR z O0 ct d d o F- PROJECT P 00 � p • CC J Dew O W J11 � L~L W Q a = U �- o • = O O Z Z Q < :- � N U) 0 U_ O F- W W - F- u_ a = otS SINGLE FAMILY \' /67 �3 O 4( TWO-FAMILY MULTI-FAMILY /N/ 1 5P-- (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE • RETAIL- MERCANTILE FACTORY OR INDUSTRIALA-- ATTACHED • a ' ,A, S GARAGE('r)3) 0 / �� OTHER (:)T IF COMMERCIAL OR INDUSTRIAL-!rCL AME OF BUSINESS: ESTIMATED CONSTRUCTION COST: `"f_>(),Om)) FUEL TYPE: �9S ?-67A l HEAT TYPu2. `HOW MANY FIREPLACE(S): / AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? /,/z IS THIS A HISTORIC SITE? _1(h, PROPOSED USE OF BUILDING OR ADDITION: 6)k,v 4:71-- (40 n, ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? /J4( ARE THERE EASEMENTS ON PROPERTY? //t) "Please complete a separate AppI cat cn for"Fuel Burning Appliances&Chimneys' available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true' and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read . -- • •- . •0 fe. ilif / 44-1 J Signed �� • ..,, Jr 1-r -- 0-).-,s 0_ Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) • Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein i accordance with said zoning Laws of the Town of Queensbury. Application: Al h/ Ali :UILF 'G : CODES AP!.R'1VAL ZONING APPROVAL ( 12 7/ D, 'E DATE QUESTIONS 7 CALL 761-8256 OR EMAIL codesna queensbury.net Office Use Only. VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 dOeiki.)017e5;:› Community Development Office Mb 0 2012 Town of Queensbury • 742 Bay Road • Queensbury, New York •12804 Office Use Only TAX MAP NO. PERMIT NO. \-1,_--ziR PERMIT FEE APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: T<,i!e- M��C�f li c. INSTALLER: /vi,1(e PI,, YYl S 5-c?Li .r-7 N. ADDRESS: .rlC'c3 r--6 y./al-}t ADDRESS: 71,4 A r/H PHONE NOS. y/,.- . 3 7 9, PHONE NOS. ,36/ - '/07'rC. LOCATION OF INSTALLATION: ze J j R ad Ad '�oxd !t `' .'` /3 RESIDENCE INFORMATION: YEAR BUILT NO.OF X COMPUTATION = TOTAL DAILY FLOW BEDROOMS _ (Gallons per bedroom) GARBAGE GRINDER 1980 or older X 150 = INSTALLED? /Y.0 1981 -1991 X 130 = SPA OR HOT TUB 1992-present Lf X 110 = INSTALLED? 1�0 PARCEL INFORMATION: I TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE I SOIL NATURE: SAND r"--- LOAM CLAY OTHER I GROUNDWATER: AT WHAT DEPTH? I BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH[mpi] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: GALLON(MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: y 9dt ❑ABSORPTION FIELD(WITH NO. 2 STONE) Total length ft. Each trench `1a X c7' ❑SEEPAGE PIT(S)(WITH NO. 3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? _________ ❑ HOLDING TANK SYSTEM Total required capacity? -- Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanitary Sew,�a�e Disposal • �..ance. codes(olqueensbury.net i 43 t, *// VISIT OUR WEBSITE FOR MORE INFORMATION Signature of Person Responsible Date www.queensbury.net • Revised 4/14/2010 OFFICE USE ONLY TAX MAP NO. PERMIT NO. PERMIT FEE • . APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. _ OWNER: /,•• e- /�3 � i, •++-C- INSTALLER: /i ffB /11o•v✓l sur L'-4f ADDRESS: --,Z"74Jrz Z /)s �i'ti'�K/ A ADDRESS: /---r A nx PHONE NOS. '8`/ 77..a PHONE NOS. ,.lv / - LOCATION OF INSTALLATION: ,L. r tit Po wc1 RESIDENCE INFORMATION: YEAR BUILT NO.OF X COMPUTATION - OTAL ILY F BEDROOMS (Gallons per bedroom) GARBAGE GRINDER 1980 or older X 150 - INSTALLED? 0) 1981-1991 X 130 SPA OR HOT TUB 1992-present X 110 /7/1/1) - INSTALLED? /yb r• PARCEL INFORMATION: ✓ TOPOGRAPHY: FIAT ROLLING ' STEEP • 0' %SLOPE ✓ SOIL NATURE: SAND r/ L• CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? ----- ✓ BEDROCK/IMPERVIOUS MATERIAL: AT W DEPTH? - ✓ DOMESTIC WATER SUPLY: MUNICIP• WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS - PER MINUTE PER INCH[mph (Test to be-. pleted by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONS r- d CTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planni :oard approved subdivision). TANK SIZE: /2 re G• •N(MIN.SIZE IS 1,000 GAL)Add 250 gallons to the size of the septic tank for e. garbage grinder,spa or whirlpool tub. SYSTEM TYPE: ❑ABSORPTI' FIELD(WITH NO.2 STONE) Total length ,20,C)ft. Each trench X l"` ❑SEEPAe PIT(S)(WITH NO.3 STONE) How many? Size? ❑AL ATIVE SYSTEM Bed or other type? ❑HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? . NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanitary Sewage Disposal Ordinance_ codes(a?queensburv.net f / Ott to 5 1 /7 VISIT OUR WEBSITE FOR MORE INFORMATION Signature of a on Responsible D [/ www.queensburv.net Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/p epart: (. \�—"�am/pm Date Inspection request received: Inspector's Initials:p NAME: I C-0rt, 0 L PERMIT#: I .)--- E° LOCATION: 9 3 Re,r c ,Nisi P 4 DATE: / ! -/ TYPE OF STRUCTURE: S F Comments: YesNo N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location f Fresh Air Intake ✓ 3 inch Plumbing Vent through roof minimum 18 inches 7/f Roof Complete/Exterior Finish Complete Platform at all exterior doors i..7, Handrail 4 or more risers j, Guards at stairs,decks, patios more than 30 inches above grade t/ Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more / Handrail Termination at Newell Post or Wall f Interior/Exterior Railings 34 inches to 38 inches ,,� Deck Bracing/Handicapped Ramp Compliant / r/ Grade away from foundation 6 inches with 10 feet � 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade , /% Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Wi�ow in stairwells safety glazing Interior Smoke DelSctors/Carbon MonoxidO Detectors Every level: -' Every Bedrogr 1: ,/ Outside every bedroom rea: - j Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area t/ Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents ` Bathroom Fans,if no window ti// Plumbing fixtures //� Foundation insulation to floor I Sticker on Panel r/ Duct work sealed properly/Blower Door Test Certification ,.// Floor truss,draft stopping finished basement 1,000 sq.ft. ./ Emergency egress below grade / Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area FurnacelHot Water Heater operating Low water shut-off boiler / ,/ Relief Valve(s)installed/Heat Trap/Water Temp 110 S/ Enclosed Stairs Sheetrock Underside minimum Y2 Gypsum Basement stairs closed rise>4 inches / Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer 4 f Gas Logs in Sealed or Glass Enclosure (/ Final Electrical; Energy Saving Light Bulbs 50% _ Final Survey Plot Plan i// _ Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles // Flex Gas Pipe Bonding k// As Built Septic System/Sewer Dept. Inspection Sticker t/ Site Plan /Variance required / Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] ;� L:IBuilding&Codes Forms1Building&CodeslInspection Fomis\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 I1Finallp Queensbury3 Buildin & Code Enforcement - esi� ntal n- ectlon Office No. (518) 761-8256 Arrive: am/pm Depart2� �t) am/pm P Date Inspection request received: Inspector's Initials: NAME: PO ,?(ISI)Ci. PERMIT#: 0--°(‘) c2 LOCATION: ` .3 fcl-t LA,A.;- (,--,r4 R ri DATE: ). TYPE OF STRUCTURE: F Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete I Exterior Finish Complete V Platform at all exterior doors vvv/'/ Handrail 4 or more risers VZ Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches ,� Deck Bracing/Handicapped Ramp Compliant // Grade away from foundation 6 inches with 10 feet f f ZrA3-/ aft, 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade i/,, Interior privacy/trim/doors I main entrance 36 inches Vz V Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety lazing Interior Smoke D, tors/Carbon Mpoxii Detectors . Every level: ✓✓ Every Bedrop6i ,,,✓✓✓/// ✓ ---1___411t) 1-- Outside Outside every bedroonyerea: d Inter Connected: V Battery backup: / \i�-("ut-. d.--t CD Attic access 30 inches x 22 inches x 30 inches(height)in accessible area t/ � Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents ������_� .- Bathroom Fans,if no window / Plumbing fixiufes---1 4-.1../V oun tion insulation ' floor/Sticker on Panel .0) properly/Blower Door Test Certification .�� Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade J <t--�- 1-6- -'5314,-r-4) Gas Furnace shut-off within 30 feet or within line of site r t ! Oil Furnace shut-off at entrance to furnace area / Furnace/Hot Water Heater operating t/ Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 �, I/ � �� Enclosed Stairs Sheetrock Underside minimum1/2"Gypsum Basement stairs closed rise>4 inches ✓j ��l Garage Floor Pitched kr✓ ��; Garage fireproofing/'/4 hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Y`V� / Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding V/ As Built Septic System/Sewer Dept. Inspection Sticker i Site Plan /Variance required0 Flood Plain Certification, if required J Okay to issue C/C or C/0[Temporary/Permanent] L:1Building&Codes Forms\Building&Codestinspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury, NY 12804 Date received: —i'c NAME: sgaro I f LOCATION: 73 60/14/►c (0,1c1 PERMIT#: • Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: Cr rgBiown, Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc • G. y V ,iv I I-Wll�o g .7.0- r. Xy� 'o, C 0, o", 5* V, SITE LOCATION MAP iJ > r Q,4 g, V -V GRAPHIC SCALE 50 0 24 2 00 Ya'! v IN "FEET Vo, I inch 50 ft. ---- CERTIFICATION I HEREBY CERTIFY TO "T IBRAHIMIGOUDA :0 BELKIS GOUDA FIDELITY NAT16N'AL TITLE INSURANCE COMPANY. nAT w[C LAAD WAC DDC�DADCn MnkJ Ahl Arnlhl Mrl n LOT It LANDS N/F MICHAEL T. LEROUX L. 2964 P. 075 LOT 9 serzsvat LANDS N/F KENNETH J LINGLE L. 3669 P. 174 105.1' LOT 5 AREA LOT 4 0.701 ACRES —LANDS N/F PAI 11 : F)[('.APR 10 G. y V ,iv I I-Wll�o g .7.0- r. Xy� 'o, C 0, o", 5* V, SITE LOCATION MAP HE � CERTIn CATION S 'HEREON 'SHALL BE PARTY,:OR PARTIES, HEREON NAMED AND NE3LE:-TO-ADDITIONAL�,'INSTITU-hONS OR Q OTWrO TUAM Aq LiAY PF7'nP IT,Z.,<ROUND POND SUBDIVISION VADE,WR 41, M iJ > r Q,4 g, V -V Ya'! v Al Vo, ---- CERTIFICATION I HEREBY CERTIFY TO "T IBRAHIMIGOUDA :0 BELKIS GOUDA FIDELITY NAT16N'AL TITLE INSURANCE COMPANY. nAT w[C LAAD WAC DDC�DADCn MnkJ Ahl Arnlhl Mrl n HE � CERTIn CATION S 'HEREON 'SHALL BE PARTY,:OR PARTIES, HEREON NAMED AND NE3LE:-TO-ADDITIONAL�,'INSTITU-hONS OR Q OTWrO TUAM Aq LiAY PF7'nP IT,Z.,<ROUND POND SUBDIVISION VADE,WR 41, M Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/pm Depart: -3) am/pm Date Inspection request received: Inspector's Initials: ,� NAME: c457Crt \ PERMIT#: Z-_Zc-c LOCATION: > DATE: l! ti c> TYPE OF STRUCTURE: t-2 Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exteri• doors Handrail 4 or more 's-rs Guards at stairs,d=- - patios more than 30 inches a•*ice grade SriXk" di'� r�-^'C___ Guard at stairwell •t 34 ches or more Guard at deck, po es • inches or more --, Handrail Terminat'•n at N:well Post or Wall f _ co .)- ..--.5517_43-X.... Interior/Exterior R.ilings 34' ches to 38 inches ...------ Deck _!Deck Bracing/Ha dicapped -amp Compliant Grade away from •undation 6' dies with 10 fee 6 inch clearance t• sill plate Gas Valve shut-o' exposed/reg .tor 18 inch: above grade Interior privacy/tri /doors/main :ntrance ., inches Bathroom/Kitchen watertight Safety glazing/Wi •ow in stairwells -• ety • azing Interior Smoke Det- ors/Carbon Mon.,'d. Detectors Every level: Every Bedroom: Outside every bedr•om area: Inter Connected: Battery backu•: Attic access 30 inche. x 22 inches x 30 i ch-. (height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq. -150 sq.ft.vents Bathroom Fans,if no 'ndow Plumbing fixtures Foundation insulation tb floor/Stick- on Panel Duct work sealed properly/Blower V oor Test Ce :fication Floor truss,draft stopping finished •asement 1,006 sq.ft. Emergency egress beloyv grade Gas Furnace shut-off within 30 feet or within line of-le Oil Furnace shut-off at etitrance furnace area Furnace/Hot Water Heater oper.ting Low water shut-off boiler Relief Valve(s)installed/ ea rap/Water Temp 110 Enclosed Stairs Sheetr U•derside minimum%"Gy•-um Basement stairs closed rise 4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker Site Plan /Variance required ti,), Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent] L:1Building&Codes Forms\Building&Codesllnspection Forms1Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 rme\1/4a. 3 `, 3cD Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ m rt:! am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: ..��••__�� NAME: ��J� PXX� PERMIT NO.: l c)NO�I LOCATION: I) Lt evi .0 .'1 d • - INSPECT ON: 11, RECHECK: Comments and/or diagram Soil Type: San / Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A [150'to well required if NO] Absorption Field: Total length f ckft. Length of each trench ft. Depth of trenches `Z ft. Size of Stone i2 Seepage Pits: Number Size: _ x Stone Size: Piping ize Type Building to tank 4" tLk 4 Tank to Distribution Box £'i Distribution Box to Field/ Pit Opening Sealed: /I__N End Cap ✓1' N Inlet/Outlet Pipes&Baffles 'A' N Manholes 12"or less below grade _Y_N [provide extension collar if Yes] _Y N Location / Separations Foundation to tank L U ft. Foundation to absorption '-A ft. Separation of Pits —MT ft. Conforms as per Plot Plan Engineer Report and As-Built —Y N ETU Maintenance Contract _Y_ N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S stem Use S s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report 03 29 10.doc C(cto —3 1- r I " • Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: AO Queensbury Building &Code Enforcement Arrive: am/pm art: I am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ' l 1 NAME: r4.5 5"9re//, _ PERMIT #: 1 --z__- 2-07 LOCATION: (73 (7z-z-(-1 On pi INSPECT ON: 1 qh,V, TYPE OF STRUCTURE: L Y N N/A Rough Plumbing /Nail Plates Plumbing Vent 1 Vents in Place 1 Yz inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction Pressure Test Drain/Vent Air/ Head 5 P.S.I. or 10 ft. above hi hest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firesto po- g pping Inspect�On Deport /6 -1 7--ft, Office No. (518) 761-8256 Date Inspection request received: `z---- Queensbury Building &Code Enforcement Arrive: _amlpm Depart: /L y-, am/ m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: n 1 /.1 PERMIT#: ) 2 - �v 7 LOCATION: - INSPECT ON: 9//71) - - TYPE J/Z1) - -TYPE OF STRUCTURE: ,.,� Y� N NIA COMMENTS: ?cframing V/ Attic Access 22" x 30" minimum \// Jack Studs/ Headers •�/ Bracing I Bridging :/ Joist hangers V/ Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches/ Holes/Bearing Walls \/ Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) ' 5.7 sf above/ below grade 5.0 sf grade L:1Building&Codes Fomes-OLD\BuiIding&Codes\Inspection Forms'Framing Firestopping Inspection Report.doc Revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: / C)( (( 1/2"- Queensbury Building & Code Enforcement Arrive: am/pm Depart: J 0 *�.Tam/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: .t 1 U NAME: nn S5 e��it ,m„,,;,_ PERMIT #: LOCATION: - INSPECT ON: /0/1-z-# TYPE OF STRUCTURE: . 'f Y N N/A Rough Plumbing / Nail Plates Plumbing Vent I Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction f, Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air I Head 50 P.S.I for 15 minutes Insulation I Residential Check I Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7, 2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/Rip Depart: H ' ) am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's lnitials:�` NAME: (, I PERMIT #: / ,)0? LOCATION: 3 Amyx'Mirt INSPECT ON: 4) -? - / TYPE OF STRUCTURE: LS -i Y N N/A Rough Plumbing /Nail Plates Plumbing Vent I Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet 1 change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes _ Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check , Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window SealedjNo Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 C/& ;`--- ( - / -3 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: /0/_C//v l Queensbury Building &Code Enforcement Arrive: am/p De art: L am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 0./ - �J NAME: PERMIT * _2—°c LOCATION: 7 j (2-cv/9 n r t,2_0;+% INSPECT ON: )1' v TYPE OF STRUCTURE: -_`1` _IL_ N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Yz inch minimum Drain Size Washin. Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head ,--- - 50 50 P.S.I for 15 minutes /Insulation I Residential Check I Com, : ial Check Tyvek or Similar Exterior Sealant r , Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape ___I j , OMME iTS7.--------1 ( ' • Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ Are ed: Queensbury Building &Code Enforcement Arrive:Lei'-?6 am part: ��,"3') arr mom, 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ` -- NAME: V� PE' #: 1 Z- Z09 LOCATION: - (� ov t ev to R\) INS- CT ON: J - 7 TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 '/ inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain I Vent Air/ Head 5 P.S.I. or 10 ft. above hi hest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation /Residential Check/Commercial Check Q0E6.-1 (2$3.5 Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent otJ V C I+ >f Door/Window Sealed (No Insulation) pts cDc- Duct/Hot Water Piping Insulation 13 s P 00-x- If required unheated spaces \ AoV& F Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report 1-1 1 d« I Ci m) Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ��A NAME: Pa S 5 a r ,\\ i PERMIT#: / o� LOCATION: �3 ?� s? t I n cl �'�.�, c•] INSPECT ON: TYPE OF STRUCTURE: W j N NIA COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing / Bridging Joist hangers Jack Posts/Main Beams1�- Exterior sheeting nailed properly 12" O.C. -, - L.. �� — Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/ Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center vIEe and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space / Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above / below grade 5.0 sf grade L:\Building&Codes Fomes-OLD\auikiin9&Code3Unspection Forms\Framing Firestopping Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report ,\f\ o n6ta (3 ( - 3 Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: l c NAME: , )mac PERMIT#: / LOCATION: (r 3 aINSPECT ON: <3_/ S TYPE OF STRUCTURE: ' r— Y N NIA COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing I Bridging Joist hangers Jack Posts I Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center / Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wail 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall _ ^ Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forma-OLD Building&CodeSUnspection Forms1Framing Firestopping Inspection Repott.doc Revived January 7,2008 Framing / Firestopping Inspection Report - text_ Office No. (518) 761-8256 Date Inspection request received: CZ— Queensbury Building &Code Enforcement Arrive: am/pm Depart. ' am •m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 4 n \' t-e t` PERMIT#: I L " RX LOCATION: C , r) IA 6 -.I INSPECT ON: c/2 (!%1Z TYPE OF STRUCTURE: Y 1417/N/A COMMENTS: Framing Attic Access 22" x 30° minimum > `' t>` ''1`'� �'• `�'T U Jack Studs/Headers i;.) Bracing 1 Bridging Joist hangers S c'c ' t c S l-��V-��-e C t ve'1 ` Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. <,!b Stairwells 36 in. or more Exterior Deck Bracing Pa-`- ( Headroom 6 ft. 8 in. • Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate ---(1171")<_3 4-k � 1 '/(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall ;! , . t 3t3f-)C Fire separation 1, 2, 3 hour / Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (VV) 5.7 sf above/below grade 5.0 sf grade L:1Buiiding&Codes Fors-OLD\Buiiding&CodesUnspection Forms‘Framinp Firestopping Inspection Repoct.doc Revised January 7,2008 [1\POCiatA g Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Dep . am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:6 -) NAME: 0-&- . PERMIT#: LQ 09 LOCATION: `7 3 �n-t-,L..n . r '1,-Ri INSPECT ON: g TYPE OF STRUCTURE: ...s Comments Y N NSA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for r&'\ --? providing protection from freezingc)- A for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab / Backfill Approval ` c--74 Under Slab PVC/Cast/Co PPer Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Bullding&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /-3 (D,?) Foundation Inspection Report Office No.(518)761-8256 Date Inspection :• rem:tv; ,: Queensbury Building&Code Enforcement Arrive: : i( p /G Depart: ®I I. .m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial* ;or NAME: P 6i P: #: / � - o 9 LOCATION: CJ' `3 Haund T ON: (� TYPE OF STRUCTURE: g r— Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM LL) ed A _.,_SCA(a<A ,)*--ki (3 e ri) Foundation Inspection Report Office No.(518)761-8256 Date Inspection req :•: Queensbury Building&Code Enforcement Arrive: 7_°6- : +ifri d epart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: —4.1 e NAME: I (.L sem., 2Q6, 'ERMIT#: I o� C% Jn LOCATION: I[.2 n etc INSPECT ON: 7 – TYPE OF STRUCTURE: r Comments DO Y / N �- Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM LOT 9 t lCA LOT 8 S8475"09 E 150.00' LOT 8 I,Y; n u 2012 ; 1 E LOT 4 i COPY L 0 T 6 LOT 5 121.0' / J� TOWN OF QU J • . to 0 OSE'/� $ 4' BUILDING & B LOT 4 i ReviewedY LOT 5 Mme=: AM" ��. Date: / 0.70± acres 40.4 ' �� k•l I LOT 6 PROPOSEDco / • HOUSE a//0, i1 { , _��.~ 43.7' 1 r . 1 l �0 •�: `) .4' r "I have seen or observed, or believe I saw evidenc ' of, . ° t all ohjects such as houses, wells, trees, fences, etc , 1- 44.7 44.7' l shown on this document. I also represent tf?Z; I ha ,e z persopally measured the distances set Isrth on th. d!egram " ,"�� i ) I. N890320"W 70.85' ly3l //f k� D4; ia N843900"W . Si NATURE ATE ROUND POND ROAD 6004 93 4,,, 4,4, . Li's CL i j._ I N I F C V N � N .GSZ�L M,SL,gReoS o v co o � 3 O � M N a Z ko y o O Fo yp h 0 4x r � N o 2 M a "�1 .�b'soz \\ Q � 3„SZ,gQeOly o Q �a a 7 N a N F O �4z0XL- \ �•. 02 0-1 J Fw - I I '$safe r I U� 1 gym" (o C3 C3 � `\ l 1 � ( II � '1 � I � � I�� I i I � � �+ moi ► i '- - --� i � \\ 0 '194 1 I � I j 1 I I III 1 1 1 I I I I 11 N o NOFNVH I r L 'o ♦ H r 'co -C6. / W o \ o_ ' r t �n r m u / 'o ew _� Y d M to cr) CO of � �6SJ6 '00,0Z .r _.. � H H 9Z 80.90 N w PA u /ON -•ot,� �� w Jnr ' as ti UNp P o i q o w N CO ,,cs•zoz � o �� .T ..9z.80.80 N 4. M.O OH UM �1 OJ d Lo O N ¢,U O o d w' J O H4 M l6'609 A o a „9z,80.80 r5�Al. co 231 A 50 u- t o a o " tnu n2 ~O d N O cn o . .ss•ozz o a o .7 .,9z,8.0.80 N `4 � me .o 'r� Lq co .. p C) Q'L O o M d