Loading...
2012-230 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120230 Date Issued: Friday, June 07, 2013 This is to certify that work requested to be done as shown by Permit Number P20120230 has been completed. Location: 26 CHARLTON Ln Tax Map Number: 523400-308-006-0002-011-000-0000 Owner: CLUTE ENTERPRISES, INC. Applicant: LUZERNE VENTURES, LLC This structure may be occupied as a: Garage Attached By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building& Code Enforcement or Zoning Board of Appeals. #1.1` TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120230 Application Number: A20120230 Tax Map No: 523400-308-006-0002-011-000-0000 Permission is hereby granted to: LUZERNE VENTURES, LLC For property located at: 26 CHARLTON Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: LUZERNE VENTURES, LLC Garage Attached 22 SULLIVAN Pky FT. EDWARD,NY 12828-0000 Single Family Dwelling $150,000.00 Total Value $150,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2012-230 1,224 sf Single Fam w/400 sf attached garage $304.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, May 16, 2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town i. ; . nsbury Wel •say, May 16, 2012 SIGNED BY ! for the Town of Queensbury. Director of Building&Code En\cement • OFFICE USE ONLY 1-E-7L: I -'' 1 TAX MAP NO. 3O Q. (p- a-I I PERMIT NO. -A 30 - ilFAY 1 U 2012 JFEES: PERMIT 36c,QORECREATION S o v ENGINEERING(If applicable) • ; • Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED ONSTRUCTION COST: 5Ci� 000 FUEL TYPE: �-�cc1 Q — 1,-. �; -9 t `� � HEAT TYPE: *HOW MANY FIREPLACE(S): AND W D TOVES S : �� � /OR00 S ( ) ZONING CATEGORY: ARE THERE �WETLANDS ON THIS SITE? V...5:-.)IS THIS A HISTORIC SITE? �v PROPOSED USE OF BUILDING OR ADDITION: ���4-Ets-� i `5�d �c e ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 7 0 ARE THERE EASEMENTS ON PROPERTY? Nc, `Please complete a separate Application for"Fuel Burning Appliances&Chimneys'available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents i ' obtain a certificate of occupancy. I also understand ir that I/we are required to pr. '.e an as-b. it :. ey by a licensed land surveyor of all newly constructed facilities pri. o issuance of . -• cate of occupancy. I have read and a. ee to ►- ...�".! ����Signed �Z 9 ' Director o :uildinq & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: -1/I" B 1 I" : & CODS "PROVAL ZONING APPROVAL IATDATE QUESTIONS 7 CALL 761-8256 OR EMAIL codes(c�queensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury•net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 Town of Queensbury Highway .J Yr / Michael F. Travis De artment AY 1 u 2812 P # Highway Superintendent 742 Bay Road, Queensbury, NY 12804 j Home (518) 798-0413 Office Phone: (518) 761-8211 Thomas R. Vanness Fax: (518) 745-4466 Deputy Superintendent Home (518) 745-0929 www. Queensbury.net DRIVEWAY PERMIT Date: S-19/1 Applicant Name: CX3 Address to be inspected: (5, ( � � ,.•�,Lc . Return Address: C.c) Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: Step 1: ( ) Preliminary Approval Need: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( )15" ( ) 18" ( )24" ( )36" Preliminary inspections completed by: Date: Approved by Higway Supt: Deputy Supt.: Upon completion, please resubmit this approved permit for a final approval. Step 2: ( ) Final Approval ( ) Rejected Date: Michael F. Travis, Highway Superintendent Thomas R. Van Ness, Deputy Highway Superintendent Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 I))-'II " , Revised 4/14/2010 ---7 OFFICE USE ONLY L:i --- TAX MAP NO. PERMIT NO. D-' 3°PERMIT FEE J �; -1,1.4 / U 2012 iAPPROVALS: ZONING TOWN CLERK • APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMITf_ LUi_1Pq <,.-`. .'6 'i=1''' A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE" ISSUANCE OF A VALID PERMIT. OWNER: C-\.a3 Nfe /L-t?.Lr.. INSTALLER: C___ ,Je n - ADDRESS: ADDRESS: e_ ) 7G kJ PHONE NOS. c PHONE NOS. ZCS ( (/" -1.277 LOCATION OF INSTALLATION: ,z9-c..7-c..7 �.C�YWC �o--%. JQ(p - a - II RESIDENCE INFORMATION: NO. COMPUTATION YEAR BUILT X = TOTAL DAILY FLOW BEDROOMS (Gallons per bedroom) GARBAGE GRIV_DEA 1980 or older X 150 = INSTALLED? '.-) 1981-1991 X 130 = SPA OR HOT TUB 1992-present <Z) X 110 = o INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLIN X STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT EPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH[mpi] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: iia GALLON (MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder,spa or whirlpool tub. SYSTEM TYPE: ( ' BSORPTION FIELD(WITH NO.2 STONE) Total length 151n ft. Each trench `')-- X 5 0 ID SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please •: - •at pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is bas-: pon or is •ranted in reliance upon any material misrepresentation or failure to make a material fact or circumstance kn• •n by or on beh.f of.• a..licant,shall be void. I have rea• he regulations wit : pect • i :pplication and agree to abide •y these ay all?• - er t - •• • of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanit- Sewag- 4is.- •••in- codesOqueensburv.net ...I_ �/ ® VISIT OUR WEBSITE FOR MORE INFORMATION ArrLure of Person Responsible Date www.queensburv.net Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspectlo1 Office No. (518) 761-8256 Arrive: am/pm Depart: (L) �J)Cirri/pm Date Inspection request received: Inspector's Initials: NAME: t PERMIT#: f 3 W7 LOCATION: Lc, C4, —:G` \, DATE: (c- '7--( TYPE OF STRUCTURE: Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 Inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window \f — r Plumbing fixtures C� Foundation insulation to floor/Sticker on Panel Duct work sealed property/Blower Door Test Certification P'—` 6-6,5 Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Rfrilj2C Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/,hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker d Site Plan /Variance required Flood Plain Certification, if required f Okay to issue C/C or C/O[Temporary/Permanent] t,! L:1Building&Codes Forms\Building&Codesllnspection Fomis\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 la 3 � RAJ NY onsulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 06/05/2013 Clute Enterprises, Inc. 6 Holden Avenue Queensbury,NY 12804 Inspection Address: Lot 10 - 26 Charlton Lane, Queensbury NY 12804 Report Number: 0508120 Dear Pam: At your request, the Blower Door Inspection of the post construction test to verify infiltration rate of the house as per requirements of the NYS 2010 Energy Conservation Construction Code of the above property was performed on 06/05/2013. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the house including conditioned basement=2,448 SF - Volume of the house, including conditioned basement= 19,584 CF Based on above,the following test data was collected: - Infiltration Rate, including conditioned basement at 50 Pascal =828 CFM - ACH50, Actual Changes per Hour at 50 Pascal = 828X60/19,584=2.5 <7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%, calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, .k0\stAus Gym 7-0 Stan Grajny, PE ffk NYS HERS Energy Rater BER-041Rp assao6 NYS PE 065406-1 'ORO S1C"i��� j kms, / - 3 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/p part: f .� am/pm P Date Inspection request received: Inspector's Initials: NAME: C]2Li±e- PERMIT#: / .).-3 3 v LOCATION: ,�U (tk\Cx,C z DATE: L —Co 13 TYPE OF STRUCTURE: Comments: Yes/No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location ✓/ Fresh Air Intake 4✓ 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Vz Guards at stairs,decks,patios more than 30 inches above grade 17Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or moreVr Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliantt/ Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade / Interior privacy/trim I doors/main entrance 36 inches f/ Bathroom/Kitchen watertight /7 Safety glazing/Win.* in stairwells safety gI- ing Interior Smoke De - ors/Carron tV]onoxide ►,etectors Every level: Eve Bedrr m. Outside every bedroom ea: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents /`c/� Bathroom Fans,if no window �J Plumbing fixtures � Foundation insulation to floor/Sticker on Panel ✓ / C4-0-6 Duct work sealed properly I Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency e.ress below grade ,, / 7 n ‘4 Q Gas Furnace shut-off within 30 feet or within line of site `j-1C) Oil Furnace shut-off at entrance to furnace area _ / �� Furnace/Hot Water Heater operating 't/ Low water shut-off boiler V r Relief Valve(s)installed/Heat Trap/Water Temp 110 17 Y Cr. T 27• Enclosed Stairs Sheetrock Underside minimum'/"Gypsum �,/y4 �— Basement stairs closed rise>4 inches � �� ,,rr Garage Floor Pitched -'_ (� L Garage fireproofing/3/4 hour fire door/door closer V Gas Logs in Sealed or Glass Enclosure / .....----- Final Electrical; Energy Saving Light Bulbs 50% // Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding V. As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C l C or C I 0[Temporary/Permanent] 0 0 L:\Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008;Revised 6/26/08;Revised 12/22/10, Revised 04/13/11 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: LI —S—/ 3 NAME: C-CC-tksL LOCATION: C r 1 PERMIT#: l cA o Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: /\) Craig Brown, Zoning Administrator Notes: L:1SueHemingway\Building.Codes.Inspection.FORMSIFinal Survey Zoning Administrator.doc MAP REFERENCE SUBDIVISION PLAN MADE FOR HAYES AND HAYES BY: VAN DUSEN & STEVES DATED: JUNE 15, 2007 LAST REVISED: NOVEMBER 5, 2007 LOT9 /Bh i II i LOT 10 20,669.82 2 sq. ft 0.47 acres I LANDS N/F OF VANCE S�gM3 S7 144.45 E \V� �/ S t e � 7 e s g rid S � r T T e Z'7 ® r s 3Y J• C.L 1 v ✓`/ 1 La 169 Haviland Road Queensbury, New York 12804AGENCY 518) 792-8474 New York Lie. No. 50135 'UNAUL*HZED ALTERATION OR ADDI➢ON i0 A SURVEY\ MAP KARIN A LICENSED LAND SURVEY°RS SEAL IS A MO[ATON Y SECTION 7209, SUB-0INSION 2, OF THE NEW YORK STATE EDUCATION I .- ONLY CGFIES FROM OF ORIGINAL OF THIS SURVEY MARKED Al11 AN ORIGINAL OF THE VAU SURVEYORS SEAL SHAD BE CONSIDEAE➢ i° BE VAUO 1RUE COPIER' CFATFlCbRONS INDICATE° HEREON SIGNIFY THAT THIS SUfl U WAS PREPARED IN ACCORDANCE 'MTI THE EXISTING GONE CF PRACTICE FOR LAND SURVEYORS ADOPTED BY THE NEW RS. STALE ASSOCIATION OF'SF PROFESSIONAL TO TNR}E(ORS. SAID CERiIFlCATO45 SHALL RUN ONLY TO ME PER. FOR WAGM THE SURVEY IE PREPARED, AND ON HIS BIRUF TO RIE TIRE COMPANY, GOVERNMENTAL ° LENDING INSR➢IR°" D9"° HERE°", AND TOME ASj�CNEES OF THE LENDING INETN➢ON.' Map of _ - /'y 7 1 Town of Queensbury, a Survey made for c. - �R., /A y� y1 y� ry /1 ry G 1 p 1 Fs G !s [ Warren County, New York ScQIe" 1, 20'' I' F ra I i 1 S 1 - � 1 O� 1 , 1 . CLO TE Dwc. N( 04007—to NO.' ,'DATE DESCRIPTION, lb LULL Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: /0 am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: C PERMIT NO.: I A-Q a LOCATION: d 1p efhaA CI.p I INSPECT ON: 5-167-1 I RECHECK: Comments and/or diagram Soil Type: ' oam / Clay Type of Water: unici•. Well Water Waterline -paration distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] Absorption Field: Total length � ft. Length of each trench ft. Depth of trenches Size of Stone Seepage Pits: Number Size: Stone Size: Piping Size Type Building to tank 4t- Tank to Distribution Box l Distribution Box to Field / Pit •14-if-c? ft,3; Opening Sealed: y'N End Cap �/ _ Inlet/Outlet Pipes&Baffles •Y Manholes 12"or less below grade _Y N r [provide extension collar if Yes] Y N Z�w Location Separationsc Foundation to tank `�� ft. Foundation to absorption -V ft. Separation of Pits — � Conforms as per Plot Plan _Y t q D Engineer Report and As-Built _Y V NI( r ETU Maintenance Contract _Y N provided Location of System •• 'roperty: Front Rear Left Side Right Side Middle Front Middle Rear S stem Use S ..t Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report 03 29 10.doc Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r- R - ed: S, / � L) Queensbury Budding & Code Enforcement Arrive:• 27+>� . �!- *art: :` 742 Bay Road, Queensbury, NY 12804 Inspector's In NAME: L v - rot'_ I -,.,--Ivy e-S/6 (PEr IT #: / 2 >O LOCATION: 7:4- C i, pi 14 Ch`; INSPECT ON: � -7// TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent I Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes _ Insulation / Residential Check/ Commercial Check Tyvek or Similar Exterior Sealant .Proper Vent, Attic Vent boor I Window Sealed (No Insulation) Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace r-- Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7, 2008 Rough Plumbing a Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 4// -d L3 Queensbury Building &Code Enforcement Arrive: am/pm Depart: /pm 742 Bay Road, Queensbury, NY 12804 Inspector's initials: NAME: / PERMIT #: LOCATION: v�(.Q '1P ► INSPECT ON: ►9/a-013 fyTYPE OF STRUCTURE: JAM' Y N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Y inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping d or 15 minutes Insula ' n / Residential Check/ Commercial Check ek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) ] --{D, Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape dXYA-Ifs"A- 3-(49 COMMENTS: CL— Rough Plumbing Insulation Reporirevised Nov 17 2003, revised February 15,2005, revised January 7,2008 L7 ted, g --tb Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/per am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: "�(T NAME: C,{ , fe PERMIT #: / 671- oa3o LOCATION: a C - r ( Laid, INSPECT ON: 4/-0-13 TYPE OF STRUCTURE: S F Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant ! (' Proper Vent, Attic Vent Door/Window Sealed (No Insulation) V Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008 Framing / Firestopping Inspection Report g -ID Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: _am/p rt��' - am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: .� i .� l . )("7 NAME: C L(. PERMIT#: / 01-,A,30 LOCATION: c L " 44 ��, INSPECT ON: 1/—f /1--/3 TYPE OF STRUCTURE: _ S� F C) Y N NIA COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing /Bridging Joist hangers ',� _ �,��cc� a-.- ''k ► c Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches I Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space / Bedrooms 24 in. (H) 20 in. (W) \.j 5.7 sf above / below grade 5.0 sf a rade L:1Building&Codes Forms-0LD\l;uildin9&CodesUnspection Fomns\Framing Firestopping inspection Repori.dec Revised January 7,2008 • COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No.IA-PI 36 Cert. N2 20423 Cut-in Card No. Ow Locagivire.La..L4-44 tti-Y Installation Consisting of.w.%-TvOtri Tr-195,36/ 4r2iss • Installed By PP.2/<- 6 -FC Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making i. ions at any time, and if its rules are violated,the Company shall have the right to v this c e. Date /of --/Zrr/ INSPECTOR Member N.F.P.A.,I.A.E.I. Framing / Firestopping Inspection Report tS Office No. (518) 761-8256 Date Inspection {-• - e•:ived: Queensbury Building &Code Enforcement Arrive: ""-c. ,a r!,• s.part:3:5::,&9_031f-Dm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. A NAME: \ CJ(SA" S PERMIT#: / r)3(f) LOCATION: ,C_ au 1 -i-v r1 INSPECT ON: TYPE OF STRUCTURE: S F D _ X N N/fie. , COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches I Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge�8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor n- ter ce and water sh'- • • • lc ••• Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above /below grade 5.0 sf grade _ L:1Buiiding&Codes Forms-OLD\Building&CodesVnspection Form'Framing Firestopping Inspection Report.doc Revised January 7,2008 fr 'Act I Foundation Inspection Report ,6-e±1566) Office No. (518)761-8256 Date Inspection request received: e -15 / . Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: CJ ! NAME: )-> �'�"�' � C`_���Q INSPECT ON: o� —c� .30 LOCATION: Lo J) TYPE OF STRUCTURE: S F ,(J Comments Jj©cL.Q_NNer Y N N/A 361-alt g Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place C Foundation Dampproofmg 0 Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Fonns\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1 -3 ( rc) Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: / -, am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:&AT) l ` NAME: k ulre, PERMIT#: 1 - 3 0 LOCATION: a lQ (� �� INSPECT ON: TYPE OF STRUCTURE: Comments Foottn N A iers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Walipour Reinforcement in Place ----L.-470 �//���z � ' Footing Dowels or Keyway in place Z-\) t�� � Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM IRF 6"8 41 's•2a� � LOT 9 144 • 45 2® X39, 3 s , 6 `®� ° .4 cre �, o o. • (9 r® o� acs, - .......... ? �` HL COP' ro 6), �, �� ��. `L LOT 11 e Ij O� 0 32.y,536 11 s . a y r o� ��r ao'�• > r.,,� • �c�S fir'` Sit Ox 75 acres j �3