2012-272 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20120272 Date Issued: Friday, July 13, 2012
This is to certify that work requested to be done as shown by Permit Number P20120272
has been completed.
Location: 216 QUAKER Rd
Tax Map Number: 523400-302-008-0001-047-000-0000
Owner: FRIENDS REALTY ASSOCIATES, LLC
Applicant: SLEEPY'S
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan,Variance, or
1��p W 1�e—
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code force nt
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20120272 Application Number: A20120272
Tax Map No: 523400-302-008-0001-047-000-0000
Permission is hereby granted to: SLEEPY'S
For property located at: 216 QUAKER Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: FRIENDS REALTY ASSOCIATES, L Commercial Alteration $60,000.00
421 SEVENTH AVE 15TH FLOOR Total Value $60,000.00
NEW YORK,NY 10001-0000
Contractor or Builders Name/Address Electrical Inspection Agency
SYNTEK CSI
STEVE NEARY 631-445-0785
85-R HOFFMAN Ln
ISLANDIA NY 11749-0000
Plans&Specifications
2012-272
Comm alteration- Sleepy's
$1,343.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,June 07,2013
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town ue sbury Wr07,2012
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
—_--__ -- — __
—_ ' ' _—~—_----_—� '--�—''-.����.+.~ `
' OFFICE USE ONLY
� `=^~A, � � .`.�� A4 � �
' , - .
' psew
| �,-�.`._.~
------------------^~----------------/
_
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL &BUILDING
PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW
BEFORE ISSUANCE opAVALID PERMIT FOR CONSTRUCTION.
xpPuCAwnau|LoER: owweR:
xooREaa: xooneoe: Lf "' /uoo/
JPHONEwOo ' ' PHONE mOe
l\ .
CONTACT PERSON FOR BUILDING&CODES COMPLIANC5-., '
LOCATION oFPROPERTY: .216 10
HAS THERE BEEN ASITE PLAN REVIEW;VARIANCE oRSUBDIVISION APPROVAL? OYES 'e NO
/FSO,INDICATE APPLICATION NO.AND DATE oFAPPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT
PROJECT 0
SINGLE FAMILY
(NO.of UNITS
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE V�
FACTORY OR
INDUSTRIAL
ATTACHED
OTHER
/FCOMMERCIAL onINDUSTRIAL-NAME orBUSINESS:
ESTIMATED CONSTRUCTION COST: FUEL TYPE:
HEAT TYPE: HOW MANY nnEPLpCe(a): AND/OnvVoVoaTovse(S): ______
ZONING CATEGORY: ARE THERE WETLANDS ONTHIS SITE?
|GTHIS 4HISTORIC SITE? NO
PROPOSED USE orBUILDING nnADDITION:
ARE THERE STRUCTURES NOT SHOWN ONPLOT PLAN? fJO
ARE THERE EASEMENTS oNPROPERTY? NO
^p/easemmmotc»"upnnat,�Apf'ocauoom'^mo/burning Anplm^r^nuommooyn' available it)our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed
Director of Building&Codes: 7G1'8258(for questions regarding Building Permits,construction codes
nrseptic systems)
Zoning Administrator:
1-821O(for questions regarding required permits, the permit process,
application requirements ortoschedule anappointment)
|
Permission is hereby granted to the above This application/pnopoaed action described ,
�
Applicant to erect or o|bar the building | | herein iefound hobe |naccordance with the �
�
described herein in accordance v�U` said iLof the TfQueensbury.
zonnga�ooeowno ~
. . �
� App|icudon'
. ' . .
. . . .
� � � �
^
!]U�FICODES�[/ ..-.A_ ~~., ,~' . . ~..-/ /u*/ | � DATE ,
QUESTIONS 7 CALL 761-8256 OR EMAIL
office Use Only VISIT
Operating Permit Issued: __yes w
Occupancy Type: Classification:
Assembly Occupancy Limit: Special Conditions:
Town cfQueensbury°Community Development Office°74QBay Road,Queensbury NYl28O
Inspection Form
Town of Queensbury Fire Marshal C:> Periodic Inspection Date: 7 X31 Timer
742 Bay Road,Queensbury NY 12804 o Re- pection
518 761 8206/518 761 8205 O Inspection Permit#:
Fire Marshals Representative
_MJ Palmer Business Name: a
Location: i C-a l 2
/GK Stillman Contact: Zile s - c�
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Sign:Normal FC 1011 &FC1029
Sign:backup FC 1011.5.3&FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906 1
Inspection of extinguisher FC 906
EVAC Pian FC 404.6
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3
Clearance to Electrical FC 605.3 ✓
Electric Wiring Enclosed/Labeled FC 605.3.1
Combustibles In Equipment Rooms FC315.2.3
F.D.Signage- FC 510 ..-�
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003 ---'�
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6 R7 &112
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY
Vacant Buildings FC 311
21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC
Kitchen Suppression Semi Annual
Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506 t�jC1 P� pc2J-;,v
t�
Operating Permit, if required will be issued after r�
Completion of Inspection
Inspection Form
Town of Queensbury Fire Marshal Periodic Inspection Date:411
me:
742 Bay Road,Queensbury NY 12804 o Re-Inspection _1 �7
518 761 8206/518 761 8205 o CO Inspection Permit#: /
Fire Marshals Representative ':�:j
_MJ Palmer Business Name:
Location: 1;w
XGK Stillman Contact: A)a ✓4.)
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Si n:Normal FC 1011 &FC1029
Sign:backup FC 1011.5.3&FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11 i _ /
,eZE:Z1j,5-/e57,
SecondaryAisle Width FC 1025&FC1029.11 tZJ !l
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906
EVAC Plan FC 404.6 ../
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3
Clearance to Electrical FC 605.3 ./
Electric Wiring Enclosed/labeled FC 605.3.1
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Inferior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24" Z
EVAC SIGNS IN Rooms FC 404.6 R1 &R2 .-/ &k*
Fuel Pump Warning Signs FC2205.6 —
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY
Vacant Buildings FC 311
21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE. OK NC
Date
Generator Annual DATE. OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC t I
Kitchen Suppression Semi Annual ` i�\ �� �
Fuel Islandression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:Installed/checked FC506
Operating Permit, if required will be issued after
Completion of inspection !c
�\u dQ-
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection est r iv
6C
Queensbury Building&Code Enforcement Arrive: a Depart: a
742 Bay Road, Queensbury, NY 12804 Inspector's In"
NAME: ` ` _ PERM T
LOCATION: C- I Q j W DATE: % -1
COMMENTS:
Y N NA
Chimney/'B"Vent/Direct Vent Location
Plumbing Vent Through Roof 8"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Pladomt/Decks
Interior 1 Exterior Balusters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.-38 in./Stop Rlsers 7"/Treads IV
Vestibules For Exit doors>3000 sq.it
All Doors 36 in.w/Lever Handles/Panic Hardware if required
Exits At Grade Or Platform 36 w x 440 QyCanopy or Equiv.
Gas Valve Shut-off Exposed&R29ulator 18' Above Grade
Floor Bathrwn Watertight/Other Floors Okay I
Relief Valve Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Sup&for Occu /Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors
> 10%> 1000 sq.ft.
%Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fine
Dampers/Fire Doors
Ceiling Fine Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30'x 2(r x 30°(h), Crawl Spam Access I W x 24'
Smoke Vents Or Fan, if required
Elevator operation and Si /Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters34 in. Checkout 36"
Handicapped Ramp/Handrails Continuous/12 In.Beyond[Both
sides
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded V
Site Plan/Variance required 7-t�k u13i1--)-V--
Final Survey, New Structure/Rood Plain certification ff req.
As-built Sepfic System Layout Required or On File ,
Building Number or Tenant Address on Building or Driveway
4'
Water Fountain or Cooler
Building Access AN Sides by 20'1 Driveable Surface 20'wWe �Q
Okay To Issue Temp. or Permanent C/O
Okay To Issue CIC
LABuilding&Codes FormMuilding&CodesUnspec ion FormslCommercial Final Inspection Report.doc Revised January 7,2008
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection reqttied:
Queensbury Building &Code Enforcement Arrive: 3'oD aDepart: 72.= 0 arpf�—
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: L er r PER #: 1 Zr
LOCATION: Z Z( 3 ti L EDA-f 1 :4—�Z— t Z
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior I Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Rlsem 7"I Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 in.wlLever Handy/Panic Hardware, if required
Exits At Grade Or Platform 36 w x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Wateftht/Othw Floors Oka
Relief Valve,Heat Trap I Water Temp.110 Degirees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Sup I for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/StoragetReceiving/Shipping Room(2 hr.), 1 %doors
> 10%> 1000 sq.ft.
%Hour Corridor Doors&Closers
Firewalls I Fire Separation,2 Hour, 3 Hour Complete I Fire
Dam rs/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator operation and Signage/Shaft Sealed
Handicappgd Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond[Both
sides
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded `
Site Plan/Variance r aired /� l
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File K
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler
Building Access All Sides b /Driveable Surtlike 20'wide
Okay To Issue Temp. grPennanent CIO
Okay To Issue C/C
LABuilding&Codes FormsXBuilding&Codes\lnspecbon FoansTommeraal Final Inspection Report_doc Revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection req t
Queensbury Building&Code Enforcement Arrive: ` = a pm rt: -an im
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: . ' c PERMIT#: t Z-- z-
-7Z--LOCATION: ( - �, M INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N AWA COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. .
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w 16 gauge 8 16D naps each side
Draft stopping 1,000 sq. ft floor trusses
Anchor Bolts 6 ft. or less on center
lee and water shield 24 inches from wall
Fire separation 1, 2, 3 hour �—:7 E r
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side', inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiiin ll
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Foans-OLOSulidN&CodesUnspedion Fom*WrmmhV FirostoPft lnapec ion Repott.doc Revised January 7,2008
Framing / Firestopping Inspection Re rt
Office No. (518)761-8256 Date Inspection ived:
Queensbury Building&Code Enforcement Arrive: part: - am m
742 Bay Road, Queensbury, NY 12804 Inspector's Initia s
I
NAME: iE1 'f V E MIT#.
LOCATION: v Lk �fl 1 PECT ON:
TYPE OF STRUCTURE:
Framing Y N HLA COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. .
Headroom 6 ft. 8 in.
StairweNs 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Wails
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D naps each side
Draft stopping 1,000 sq. ft floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side', inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuiiding&Codes Forms-oi.[ft11ding&CodeaMnspection Foran WMrnhV F{otoppinp inap$Cbon Report.doc Revised,Mnuary 7,2008
Inspection Form
� t
Town of Queensbury Fire Marshal 0 Periodic Inspection Date: Time: }
742 Bay Road,Queensbury NY 12804 o Re-Inspection
518 761 8206/518 761 8205 ,;,>CO Inspection Permit# p -••,i f
Fre marshals Representative -
,,MJ Palmer Business Name:
T Location: r: P s ryc-
Io,:GK Stillman Contact: t-w f ' t. c" H c',, 3
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020&FC1029 �.
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Si n:Normal FC 1011 &FC1029 .
Sign:backup FC 1011.5.3&FC1029.7.5 -
AISLES: .,
Main Aisle Width FC 1024/1025&FC1029.11
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906
EVAC Plan FC 404.6
TRUSS ID SIGNAGE FC 505.3 ^
EMERGENCY LIGHTING: ; ' +`
Interior FC 1006.3&FC1029.8 �-
Exterior FC 1006.3
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1r
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510 .>-t"ta :%•, !1 t !�< w r_p
No Smoking Signs FC 310.3 "'
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6 R1 &R2
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY
Vacant Buildings FC 311
21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: O% NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual ,
FIRE ALARM Annual `U~' DATE: OK NC
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC
Kitchen Suppression Semi Annual
Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506
Operating Permit, if required will be issued after
Completion of Inspection
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins " n st re i
Queensbury Building &Code Enforcement Arrive: a :--i a.
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: "� PERMIT
LOCATION: s' INSPECT ON: 7
TYPE OF STRUCTURE: C /4--
Framing Y N I WA COMMENTS:
Attic Access 22° x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. .
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1
%(w 16 gauge 8 16D Wads each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
lee and water shield 24 inches from wall
Fire separation 1, 2, 3 hour 7'
Fire wall 2, 3, 4 hour
Firestopping , \ rev ` ` 1 �-►�
Penetration sealed
16 inch insulation in Cavity min.
Garage Fire Separation 7Z _
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H) �-�— �� k
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuiiding&Codes Forms-01-Muilding&CodesAlrgxx tion Fom*\Framing Fir ping Inspection ReporLdoc Revised January 7,2008
U3 ea L),-1
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date inspection r e 4- `
Queensbury Building &Code Enforcement Arrive: a a m
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Sk e e A u 's P MIT##:
LOCATION: Q i V INSPECT ON:
TYPE OF STRUCTURE: e®ry -�-
Y NIA
-Rough Plumbing/Nail Plates ymaak V"'
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.1 for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report,revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firesto PP 9 Pe Po in Inspection e rt ��.
Office No. (518)761-8256 Date I n r 2 0
Queensbury Building &Code Enforcement Arrive: t�
742 Bay Road, Queensbury, NY 12804 Inspector's inttia
NAME: If elip bAS— PERMIT#: �C� "C
LOCATION: INSPECT ON: dd
TYPE OF STRUCTURE: 6 LV� C( �� --ALL.
Y A N I ULA COMMENTS:
taming
Attic cress 27 x 30" minimum . y
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly (, ,
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more f
Exterior Deck Bracing
r
Headroom 6 ft. s in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 h w 16 gauge 8 16D naps each side
Draft stopping 1,000 sq. fL floor trusses G
Anchor Bolts 6 ft. or less on center 61 p J
ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in 2@vq min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-QLDSuilding&Codesllnspection FOM07=409 FiOtopPing inapectbn RePort.doa Revised January 7,2W8