Loading...
2012-425 ��� TOWN OF QUEENSBURY 742 Bay Road, Qucensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120425 Date Issued: Thursday, May 23, 2013 This is to certify that work requested to be done as shown by Permit Number P20120425 has been completed. Location: 152 RIVER St Tax Map Number: 523400-303-020-0002-040-000-0000 Owner: RICHARD MOZAL Applicant: RICHARD MOZAL This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. r TOWN OF QUEENSBURY F 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120425 Application Number: A20120425 Tax Map No: 523400-303-020-0002-040-000-0000 Permission is hereby granted to: RICHARD MOZAL For property located at: 152 RIVER St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RICHARD MOZAL Residential Alteration $30,000.00 16 FOUNDERS Way Total Value QUEENSBURY,NY 12804-0000 $30,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency NELSON BATTIS NY 12804-0000 Plans&Specifications BP 2012-425 Due to fire damage in Apartment downstairs, interior residential alterations - floor joists. $60.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,August 30, 2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of ueen ry11ur st 30,2012 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement .3-63,,,& .)_VO OFFICE USE ONLY TAX MAP NO. PERMIT NO. Date FEES: PERMIT RECREATION ENGINEERING S (If applicable) � � PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: /`,.. j �,� ' ` � �� OWNER: �2Q/Y! 7,: /---- ADDRESS: /30 lee (Vo 1`✓' Pdfi-atm.....)ADDRESS: i PHONE NOS. 6578) 6g3- g 3 Z Li PHONE NOS. CONTACT PERSON FOR BUILDING & CODES COMPL NCE: A/401-14t PHONE: 6 g3-025i LOCATION OF PROPERTY: /5 I V`e i- r HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES ❑ NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z lY 0' o 1- PROJECT --.W -J W u✓ u) 0 Off; • O � W Q � _ _ W J o = o U U Z Q Q `- � N � Ou OF- � wZ 1- u_ a = 06 SINGLE FAMILY TWO-FAMIL//' l^ �'r/d -`rvr� 'u MULTI-FAMILY UNITY Gy /� Q l � (N0.of UNITS ) /�'QL TOWNHOUSE c - C '/ .v '_.!- / I BUSINESS OFFICE I Oj/ ci>-7 RETAIL- ,t{� MERCANTILE r;e1 FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—N9p11E OF BUSINESS: ESTIMATED CONSTRUCTION COST: (T). 1 a C) 6 FUEL TYPE: HEAT TYPE: *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THI SI E? I IS THIS A HISTORIC SITE? p\........ ,..., __..\., PROPOSED USE OF BUILDING OR ADDITION: *Please complete a separate Application for"Fuel Burning Appliances& Chimneys"available in our office B 3-LGL 11-05 Q: ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and ree to thea ove. Signecr / Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: L /4 1/f��/ BUILD f ' & CODES APROVAL ZONING APPROVAL (6 1-1 .Z V D TE DATE QUESTIONS? CALL 761-8256 OR EMAIL codesAqueensburv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: Yes No www.queensbury.net Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: A Queensbury Building & Code Enforcement - Residential F n •ection Office No. (518) 761-8256 Arrive: -' 3�✓� a /11 •• . ,....777-145 a /prr Date Inspection request received: Inspector's Initials: NAME: \.) ` _ PATMIT#: I Z—Lt LOCATION: _ 72 ^ ] Z TYPE OF STRUCTURE: Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors I main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer ` Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% /(C) Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding �f As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required \/:// Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codeslinspection Forms1Residential Final Inspection Form_revised 100405.doc;Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 0E-tht0 533. 2H- weg 3 Queensbury Building & Code Enforcement - Residential�a E spection Office No. (518) 761-8256 Arrive: \ 1 am/,• r ;! part: 1i'- j1) /pm Date Inspection request received: Inspecto s Initials: . . ,. s 1, NAME: A'I (f 4(� ' o �.0 PE1 r IT#: 1� �, LOCATION: 5 & ( ] l7 Lor- S-� D ( E: a —/3 TYPE OF STRUCTURE: e3 0-1 +— Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing I'/4 hour fire door/door closer Gas Logs in Sealed or Glass Enclosure * � Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles L -C V-\ Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/O[Temporary/Permanent] L:1Building&Codes Forms\Building&Codes1Inspection Fomts\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 I „ ,3 Inspection Form Town of Queensbury Fire Marshal Q Periodic InspectionDate: 3- 'ITime:: 742 Bay Road,Queensbury NY 12804 4111P Re-Inspection cA 518 761 8206/518 761 8205 o CO Inspection Permit#: / �. — 7 5 7arshals Representative J Palmer Business Name: Co! Location: 15- a (-K u Q,r {- _ GK Stillman Contact: I n () cc 'Ru Type of Inspection N/A Yes No EXITS: Exit Access FC 1014& FC1029 NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 Locks and latches FC1008& FC1029.2 Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3& FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025&FC1029.11 Secondary Aisle Width FC 1025& FC1029.11 FIRE EXTINGUISHER: Hung FC 906 / /("\f it'iP Inspection of extinguisher FC 906 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: ' Interior FC 1006.3&FC1029.8 I liiir )____, Exterior FC 1006.3 ONClearance to Electrical FC 605.3l i TElectric Wiring Enclosed/Labeled FC 605.3.1VVV Combustibles in Equipment Rooms FC315.2.3 F.D.Signage- FC 510 No Smoking Signs FC 310.3 Storage FC 315.2 Compressed Gas FC 3003 Vehicle Impact Protection FC 312.1 Interior Finishes FC 803-804 Smoke Detectors FC 907 CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315 .2.1 18" / 24" EVAC SIGNS IN Rooms FC 404.6(R1 &R2) Fuel Pump Warning Signs FC2205.6 Fuel Station Emer Procedures FC2204.3.5 Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATELY Vacant Buildings FC 311 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date • Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Kitchen Suppression Semi Annual Fuel Island Suppression Semi Annual Hood Cleaning 3-6 -Annual Knox Box:installed/checked FC506 Operating Permit, if required will be issued after Completion of Inspection Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date In:pectio .req" ► :• ed: Queensbury Building & Code Enforcement Arrive: %Z.•a _17 +� - : am/ 742 Bay Road, Queensbury, NY 12804 Inspector's lniti- sf / ' NAME: �F, i �- f PERMIT#: LOCATION: �5' , � moi?j INSPECT ON: TYPE OF STRUCTURE: f N NIA COMMENTS: Framing V Attic Access 22" x 30" minimum Jack Studs/ Headers V Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting�+ nailed properly 12" O.V. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing ' Headroom 6 ft. 8 in. • Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'fix(w) 16 gauge (8) 160 nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilin_ all Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf •rade L:\8uilding&Codes Forms-OLD\Duilding&Codes\Jnspect on FomnslFraming Firestopping Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Res ert (J X30 Office No. (518) 761-8256 Date In:.. = .'•n Flk Nk Queensbury Building&Code Enforcement Arrive: • ,: • : "$ 'i a 742 Bay Road, Queensbury, NY 12804 Inspector's InitI • — pest ../ NAME: R l Ouz_Pt I.._ MIT#: 1 : H {)G� LOCATION: 1'.F 7 \E_K INSPECT ON: • — — ' TYPE OF STRUCTURE: c(c83-- 37 1--11 c: deo -331-\ Y t� A COMMENTS: Framing _ Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging \o 7)e- Joist Ja Jackck Posts sts//Main Beams Exterior sheeting nailed properly , 1-�'Th 'stt• 12" O.C. Headroom 6 ft. 8 in. 7 k E 7 —c\ Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate EL-O � �� C_ � 1 %(w) 16 gauge (8) 16D Haus each side Draft stopping 1,000 sq. ft. floor trusses \o \ Anchor Bolts 6 ft. or less on center a7. Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour f--A\-1 Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. ,,`` // Garage Fire Separation C� �v v '� ``__�\ WD u \`L. House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:U3uilding&Codes Forms-OLDU3uIlding&CodesUnspedion Fom e&Framing Firestopping Inspection Report.doc Revised,January 7,2008