Loading...
RC-000352-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 — 111191W Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000352-2016 Date Issued: Thursday, July 27, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000352-2016 has been completed. Tax Map Number: 309.14-1-44.2 Location: 9 RIVERSIDE DR Owner: Sara Pearsall,Adam Pearsall Applicant: Adam Pearsall This structure may be occupied as a:Residential Addition/Alteration 1st floor-260 s.£ By Order of Town Board 2nd floor--156 s.f. TOWN OF QUEENSBURY Deck 368 sq. ft. Cross Ref.Area Variance PZ-0107-2016 approved April 20,2016 by ZBA n /f Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, GGG Y Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 �- Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-000352-2016 Tax Map No: 309.14-1-44.2 Permission is hereby granted to: Hilltop Construction For property located at: 9 RIVERSIDE DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Sara Pearsall Single Family-Addition 586,000.00 Owner Address: 9 Riverside DR Total Value $86,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Hilltop Construction 51 Crowley RD Hudson Falls,NY 12839 Plans& Specifications Residential Addition/Alteration 1st floor--260 s.f. 2nd floor--156 s.f. Deck 368 sq. ft. Cross Ref.Area Variance PZ-0107-2016 approved April 20,2016 by ZBA S 160.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday,July 21,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ue ury; �hua 1, 2016 SIGNED BY: , for the Town of Queensbury. Director of Building&Code Enforcement Date: une Permit Na. Tax Map?D 23 - Permit Fee l �Qa.00, nW Zone Historic? _Yes No Ree Fee Subdivision Name Lot# Site Plan# Subdi inion# Project Location q '�r�r�S I _.,...� r��� "TOWN BD.RESOLUTION 86-2413: $854 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Pearso-i Address Phone/Email 5 e\ C ravlebVVI Applicant Address Phone/Email { _ CV Cf6(Y)e_ffl_+k1 ; vwl Contractor p . Address Phone/Email Contact Person for Building & Codes Compliance; �1 Phone TYPE OF CONSTRUCTION ,/Check all that apply New Addition Alteration 11,floor sf 2°d floor sf Total sf Height Single Family �Z / Two-Family Multi-Family (#of units Townhouse Business Office { Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Other L7eC.k w� 3 FSF Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Mcicw ' , Source of Heat(circle one) Gas it Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? _'_I4 20 Are there easements on the property? Site Information: a. Dimensions or acreage of lot 1 b. Is this a corner lot? Yes x No c. Will the grade be changed as a result of construction Yes '< No d. Public water or Private well (circle one) Public Privat e. Sewer or Private Septic System(circle one) Sewer rivat Value of all work to be performed (labor or materials) $ 'RU DQQ DECLARATION.• 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the I year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement I description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I 1 we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: DATE: SIGNATURE: �' ;;�,�,�, �avJ � 1� DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 7/13/16 Ref: Pearsall Project, 9 Riverside Drive,Queensbury NY 12804 The following notes shall be amended to the above referenced project: 1. Mechanical ventilation will be required per the New York State Building Code. The mechanical ventilation rate must be greater than 0.35 air changes per hour. To calculate the number of air changes per hour,the formula below can be used: L #of air changes/hour= unit ventilation rate (CFM)*60 minutes/volume of the room 1. The volume of the room is equal to 7,200 cubic feet a. Therefore the minimum CFM ventilation rate for the unit being purchased must be greater than 42 CFM. 2. Suggested manufactures and models could be: a. Life Breathe Residential Ventilation—HR, max series, 60-76 CFM b. E-Z Breathe Basement system, 138 CFM 2. Spray foam insulation will be utilized between the roof rafters instead of the fiberglass batt insulation. Approximately 9%" inches of foam insulation will be installed and will be expected to produce a R-value of 38. Saratoga Engineering & Design Douglas W.Adams PE 74 Rolling Hills Drive Gansevoort, NY 12831 nF NP P vbS w CO t JUL a 0 2016 9f7fi�SSl�J�A�k. • 6/25/16 Ref: Pearsall Project,9 Riverside Drive,Queensbury NY 12804 The following notes shall be amended to the above referenced project: 1. The REScheck document has been revised using R30 batt insulation. The REScheck document was generated using the entire house envelop due to the 10'x26'addition by itself would not meet the building code due to the high%of glass(new/existing)versus new wall area. 2. The ceiling insulation system has been changed from R-38 to R-30 batt insulation with a vapor barrier and proper vent. 3. Ice&water shield shall be applied to all eaves. This protective membrane shall extend from the eave's edge to a point at least 24"inside the exterior wall line of the building. 4. The maximum height of the deck of above the finished grade shall not be greater than 30". 5. The curb around the new loft area is not an open space. See attached sketch for details. 6. The new addition shall be air sealed. All cracks and penetrations shall be sealed against air infiltration into the building envelop. 7. All new lighting fixtures are to be LED or Compact Fluorescent fixtures. 8. The new loft area is included in the light and ventilation calculations for the great room. 9. vrle for the new addition windows&doors is attached. Light/ventilation and "gt o as been show on this document. 0 S E Do 74 Ro 'off � SSr Gansevoo , X _ � UJ O 4 ti 4WW _ X X c W � tiX3 9 p = M" CP = -f, L4 = ci > to O n N n Q @' r �. s NIT N @ p �i � � s Q n � � @ @ a 3 cn O ` '� o@ X� � Nd �l� NDN @ O LC QCJ N @- r 1 � o�A 4 VCS,\ �\, lIL CP 1 '' rNEER O-m3 0>- qt 29 a - w - a a u u - 0-4 I Biala REScheck Software Version 4.6.2 + Compliance Certificate Project Homo Addition Energy Code: 2010 New York Energy Conservation Location: Warren County, New York Construction Type: Single-family Project Type: Addition Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 9 Riverside Drive Adam &Sarah Pearsall Douglas W.Adams Queensbury, NY 12804 9 Riverside Drive Saratoga Engineering & Design Queensbury, NY 12804 74 Rolling Hills Drive Gansevoort, NY 12831 518-683-6899 saratogaengndesign@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 1.2%setter Than Code Maximum UA: 579 Your UA: 572 The%Better or worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont.Assembly or R-Value R-Value U-Factor UA Perimeter Basement Wall 1: Solid Concrete or Masonry 992 13.0 0.0 0.064 61 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Window 5:Vinyl/Fiberglass Frame:Double Pane with Low-E 46 0.360 17 Comment: bowman-kemp Floor 1: Slab-On-Grade:Unheated 85 7.5 0.708 60 Insulation depth: 4.0' Wall 1-South: Wood Frame, 16" o.c. 702 21.0 0.0 0.057 25 Window 1: Wood Frame:Double Pane with Low-E 266 0.300 80 Comment: all windows/sliding door with southern exposure Wall 2- East: Wood Frame, 16" o.c. 1,278 21.0 0.0 0.057 63 Window 2: Wood Frame:Double Pane with Low-E 156 0.300 47 Comment: all windows/sliding door with eastern exposure Door 1: Solid 21 0.340 7 Wall 3-West: Wood Frame, 16" o.c. 1,278 21.0 0.0 0.057 69 Comment: all windows with western exposure Window 3: Wood Frame:Double Pane with Low-E 76 0.300 23 Wall 4-North: Wood Frame, 16" o.c. 725 21.0 0.0 0.057 36 Comment: all windows with northern exposure Window 4: Wood Frame:Double Pane with Low-E 95 0.300 29 Ceiling 1: Cathedral Ceiling 945 38.0 0.0 0.027 26 Project Title: Home Addition Report date: 07/19/16 Data filename: CAAutoCad Drawings\Adam & Sara Pearsall\182-16 REScheck.rck Page 1 of 7 Gross Area Cavity Cent. Perimeter Ceiling 2: Flat Ceiling or Scissor Truss 964 38.0 0.0 0.030 29 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Douglas Adams Name-Title Signature Date Project Notes: Due to the high percentage on glass in the 10'x26' addition, the whole house must be used to show compliance to the NYS Energy Conservation code. FES SI00'`' Project Title: Home Addition Report date: 07/19/16 Data filename: C:1AutoCad Drawings\Adam & Sara Pearsail1182-16 REScheck.rck Page 2 of 7 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified & Req.111)# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions ID 103.2 :Construction drawings and ❑Complies [PRI]' (documentation sufficiently ❑Does Not demonstrates energy code ❑Not observable compliance for the building envelope. El Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR31' demonstrates energy code t compliance for lighting and [-]Not Observable mechanical systems. Systems ❑Nat Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. ` 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR211 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not £� on loads per ACCA Manual or g; g: ❑Not Observable Conlin Conlin other approved methods. Btu/hr Btu/hr ®Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier3) Project Title: Home Addition Report date: 07/19/16 Data filename: C:1AutoCad Drawings\Adam & Sara Pearsallt182-16 REScheck.rck Page 3 of 7 Section # Foundation Inspection Complies? Comments/Assumptions & Renl.11] 303.2.1 Exposed foundation insulation ❑Complies [FO11]2 protection. ❑Does Not ❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Home Addition Report dare: 07/19116 Data filename: C:1AutoCad DrawingslAdam & Sara Pearsal11182-16 REScheck.rck Page 4 of 7 Section plans Verified Field Verified # Framing/ Rough-in Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 I is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 j or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Nat Applicable limits. 402.4.5 IC-rated recessed lighting fixtures; ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate&It;= 2.0 cfm leafage at 75 Pa. ❑Not Observable . ❑Not Applicable 403.2.2 'All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes, and ❑Does Not .building cavities used as return ducts are sealed. ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Nat Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 4F are insulated to R-3. ❑Not Observable ❑Nat Applicable 403.4 Circulating service hot water R- R- ❑Complies [FR18]2 pipes are insulated to R-2. ❑Does Not 0) ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are; ❑Complies [FR19]2 installed on all outdoor air ❑Does Not 01 intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Horne Addition Report date: 07/19/16 Data filename: C:\AutoCad Drawings\Adam & Sara Pearsall1182-16 REScheck.rck Page 5 of 7 Section # insulation Inspection Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation labeled or ❑Complies [IN13]2 installed R-values provided. ❑Does Not u ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Home Addition Report date; 07/19/16 Data filename: CAAutoCad Drawings\Adam & Sara Pearsall1182-16 REScheck.rck Page 6 of 7 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .]D 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [F[17]1 of&lt;7 ACH at 50 Pa.This requirement may instead be met ❑Not Observable via visual inspection, in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm ;❑Complies [F]4]1 construction with maximum ;❑Does Not leakage of 8 cfm to outdoors, or 12 cfm across systems. For ;❑Not Observable ; rough-in tests,verification may ;❑Not Applicable need to occur during Framing Inspection, with maximum leakage of 6 cfm across systems and 4 cfm without air handier. 403.1.1 Programmable thermostats ❑Complies [F19]2 installed on forced air furnaces. '❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F[10]2 on heat pumps. ❑Does Not ❑Nat Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. []Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for - ❑Complies [FI18)3 mechanical and water heating ❑Does Not 61J equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Home Addition Report date: 07/19/16 Data filename: CAAutoCad Drawings\Adam & Sara PearsaN1182-16 REScheck.rck Page 7 of 7 9C - boD35Z- ZD1lo Alpine, an ITW Company 13723 Riverport Dr,Suite 200 Maryland Heights,MO 63043 (314)344-9121 Page l of Document ID:IVSP219-ZI626094300 ex�•�r 1,t•i -..--��-�.,� Truss Fabricator: S.R. Sloan Transmitted From: co 'q Job ,f j!r, �%• „M Job Identification; R454616 - Barrett / SRA / Greenway Y �" •'r:�' !k.�>t i, Model Code: IRC �• ^i teta =1,! y;• !:. ¢; Truss Criteria: nl`t°"�'�'" '•'7 '7: IRC2006/TPI-2002(STO) C Engineering SoRtvme: Alpine proprietary truss analysis software. Version 16.01. Truss Design Loads: Roof - 63.2 PSF @ 1.15 Duration t`� p�Ul,�• J? Floor - N/A p, Wind - 90 MPH (ASCE 7-05-Closed) S Notes: 1. Determination as to the suitability of these truss conponents for the 07/26/2 structure is the responsibility of the building designer/engineer of record, as defined in ANSI/TPI 1 2. As shown on attached drawings; the drawing number is preceded by: MOUSR219 Bruce Feldmann Details: BRCLBSUB- Submitted by BAF 09:42:55 07-26-2016 Reviewer: BAF Ref Description Drawing#_ Date 1 5621 -T01 28'7" Corawn 15208092 07/26/16