Loading...
2006-097 QUEENSBURY TOWN OF 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20060097 Date Issued: Friday, June 09, 2006 This is to certify that work requested to be done as shown by Permit Number P20060097 has been completed. Tax Map Number: 523400-297-007-0001-006-000-0000 Location: 55 CHESTNUT RIDGE Rd Owner: ANN MC CANN Applicant: DAN & CASEY CONGEL This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the i property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. 0/64 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060097 Application Number: A20060097 Tax Map No: 523400-297-007-0001-006-000-0000 Permission is hereby granted to: DAN & CASEY CONGEL For property located at: 55 CHESTNUT RIDGE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ANN MC CANN Residential Addition $96,000.00 55 CHESTNUT RIDGE Rd Total value QUEENSBURY, NY 12804 $96,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency KREPPEIN CONSTRUCTION 49 IRIS Ave SOUTH GLENS FALLS.NY 12803-0000 Plans&Specifications 2006-097 2000 sq ft RESIDENTIAL ADDITION $240.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, April 06, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Q nsb To , s;•y, April 06, 2006 SIGNED BYfor the Town of Queensbury. Director of Building&Code En orcement Inner Office Monetary Release Form To be used in conjunction with Accounting Office&Dept. of Community Development,Town of Queensbury Name: if, l/�i 4� V„ File Number: 06 .-O77 Deposit Release 74' Certificate of Occupancy ❑ Temporary Sign Permit The Department of Community Development Office requests release of the following monetary deposit: X) $100 Temporary Certificate of Occupancy Our records indicate the applicant has complied to building &zoning codes. A Permanent Certificate of Occupancy has been issued on: [� $50 Temporary Sign Permit The temporary sign has been removed as the time frame for placement of the sign has expired. Please refund the deposit to: 00 C,C ) td(k10� J e kcj 61ishocy iuy Other Notes: Respectfully submitted, Community Dev. Staff Initial Date: Marilyn Ryba, Executive Director Dept. of Community Development MR/sh Department of Community Development-Building & Codes Office Town of Queensbury, 742 Bay Road, Queensbury, NY 12804 L:\Sue Hemingway\Building.Pemiit.PORMS\Rcicase Deposits form.doc • BLDG. PERMIT NO. :00 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; 55 cheb:+nu.c -�Ridge Road for the following uses: Reaiderz:;i.a,t Addi %ton Dr_25)„, A--k -4 ( DATE SIGNATURE OF APPLICANT TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby (' APPROVED ( )DISAPPROVED with the following conditions:. e/ .:4ccue. o{y occupancy-:-o be. .i.szueu. upon compfe- -on (-5L , 1 ; is. ci.:.Yic; TEMPORARY CERTIFICATE OF OCCUPANCY FE 0.00 PO IT: $li0.00 i:d t1I Z5. it 20C:o received on Date of Issuance Director of Bldg. & Code force ent THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES ,A; DAYS FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. OFFICE USE ONLY TAX MAP NO. PERMIT NO. 00 (.0-09 7 Date tS FEES: PERMIO, RECREATION ENGINEERING Stam (If applicable) P PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: / /I �fAi ev1', T' OWNER: VAN g cohl t ADDRESS: 11 if 'j /4-17 .• OF i'/ 1 / OSADDRESS: 55 ct-I `JL'r 1 �� PHONE NOS. g/'7' 37-to ' / ? ! 7 PHONE NOS. 67e).-193 ' 1-'2-622--- CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: - KKti-5 ,Rf-IONE: 57(0 17 9 7 . G. /` ; /r-- LOCATION OF PROPERTY: S5 1g Z7 11J1 ��£ / o4i , 7 /--6 l SUBDIVISION NAME: / q,4 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z o ct rz o d a LL PROJECT O Q O p • f w �=W ~ w JOS � � w % 0 = v Z < < `- O Zcv0 0u d1o2! SINGLE FAMILY /,ij-C90 P60 1 TWO-FAMILY j i MULTI-FAMILY (NO. of UNITS ) RECEIVED TOWNHOUSE MAR 0 7 2006 i BUSINESS OFFICE I TOWN U: ,,4,_,L-_LINStiURY Al II DING AND CODE RETAIL- ; MERCANTILE FACTORY OR INDUSTRIAL _ ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL- NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 9//,,�.f�/ud�Please complete a separate Application / j S/ for"Fuel Burning Appliances &Chimneys" HOW MANY FIREPLACE(S): / OODSTOVES(S): available in our office ZONING CATEGORY: t< ARE THERE WETLANDS ON THIS SITE? No IS THIS A HISTORIC SITE? NO PROPOSED USE OF BUILDING OR ADDITION: ge /per Ge ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 116 _.._:::, Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE EASEMENTS ON PROPERTY? No I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Sign iatWL.— IOW Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in .cpordance with said zoning aw&afl a Town of Queensbury. Application: APPROVED Ap.lication Fir�' 3 2006 AM& MIS BUI i G & CODES` APPROVAL ZONI G A" 'rii •ministrator TOWN OF QUEENSBURY OP DAT PAT DATE QUESTIONS ? CALL 761-8256 OR EMAIL codes(a,queensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 l � Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ec /p-r€quest received: Queensbury Building& Code Enforcement Arrive: VI • `) am/p , Wart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspectors nitials: /�— NAME: Co.)&' - PERMIT#: 69• --do?? LOCATION: CIAO TJUr2 i>C06-- INSPECT ON: IINI TYPE OF STRUCTURE: YN N/A COMMENTS Framing Jack Studs/Headers f ' Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L.\SueHemingway\Building.Codes.inspection.FORMS\Framing Firestopping Inspection Repon.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ectionquest received: Queensbury Building&Code Enforcement Arrive- b�0) am/p part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspe or's`Initials: NAME: Q-(31\-°-0 _ _ PERMIT#: _ 1 LOCATION: S C O± i (��`P INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 I/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bots 6 ft.or less on center ,Q�/� I nd water shield 24 inches from wall 4/ 1/01-- "�/V Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: C\e"c\ PERMIT #: 06-- M9 7 LOCATION: 5 ,� � � -�� INSPECT ON: �` /- O (p TYPE OF STRUCTURE: J l Y N N/A Ave.-7bi),)VC: R-1, R-2, R-3, R-4 Drain/Vents S��� /J Cast Iron, pper Drain/Vent/ Comm. Plu ' g Vent/Vents in Place fe.f/E S '4S ough Plumbing/Nail Plates Ij 1 '/Z inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction �) Water Supply Piping !" Cooper Commercial Cooper, CPVC,Pex One and Two-Family — Insulation/Residential Check/ Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report doe November 17,2003 Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ectio jquest received: Queensbury Building&Code Enforcement Arrive: / a epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector s Initial NAME: • , PERMIT#: 0 Co '09,7 LOCATION: ' _‘11._ -. .• . , ` r �0) INSPECT ON: 5 -/ CAp TYPE OF STRUCTURE: Y N NIA COMMENTS aming rin Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Ain Joist hangers Jack Posts/Main Beams ()) Exterior sheeting nailed properly 12"O.C. .�llGjl q// r(N7 l i`, A K6-7 Headroom 6 ft. 8 in. ,Q Stairwells 36 in. or more / /1-r Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate M®U l /7( Mr/ L A-LCC z75 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses G� Anchor Bolts 6 ft. or less on center C� pL< /2—� / Ice and water shield 24 inches from wall J v PS Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping ✓ /JA,r 0-4-6 Penetration sealed " 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ct oo quest received: Queensbury Building&Code Enforcement Arrive: ',,ti am/pm part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto s Initials: /y_ , . .7 NAME: pea,C-1.--O� PERMIT#: ✓Z(J LOCATION: C-6-57-AJJT Vq.1,D 6 C INSPECT ON: —© Cr 4 TYPE OF STRUCTURE: Y NAVA Framing 7 COMMENTS Attic Access 22"x 30"minimum 6(/1-1 g / 4 5 /4- Jack Studs/Headers Bracing/Bridging 77 i -5 c ,,/ 55e2 Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/a(w) 16 gauge(8) 16D nails each side • Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center lIce and water shield 24 inches from wall F. a separation 1,2, 3 hour ire wall 2, 3,4 hour _ . , / FirestoPPing I �' '�`PJ-7� 7 �iP . �.� G-t! . �_"Y �� LI � G�IJ� Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X ,-1 . ✓ Ceiling/wall V �\ I ") C/ 1/ -� Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: amtpr1 p depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �.J I LC/ NAME: (-_'!` e" PERMIT #: CV 3T7 LOCATION: n-c6 1 fok f ,e, t7� INSPECT ON: 5-P -IOCe TYPE OF STRUCTURE: / /Rough Y N/ N/A / _ ,�Plumbing / Nail Plates .4 S, -t(- ` `'¢0-5 Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum leanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head / fv. 5 P.S.I. or 10 ft. above highest connection for 15 minutes 4/1- ed;yeyor Pressure Test / Water Supply Piping J Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace fDuct work sealed properly / No duct tape [ COMMENTS: L:\Pam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspecti n re est'received: • Queensbury Building & Code Enforcement Arrive: m/ m part: am/p/i 742 Bay Road, Queensbury, NY 12804 Inspect is Initials NAME: �� PERMIT #: Q " LOCATION: ( _/(‘- 7;z4)-/-- INSPECT ON: TYPE OF STRUCTURE: Y i N N/A ? 4.5.43.4 / Nail Plates vt Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head l� 5 P.S.I. or 10 ft. above highest connection for 15 minutes 44�/16,MU Pressure Test Water Supply Piping Air / Head I50 P.S.I for 15 minutes nsulation / Residential Check / Commercial Chec ,kms ,/ 6* j> s/tl`a Proper Vent, Attic Vent Duct / Hot Water Piping Insulation Of5. If required unheated spaces �,,� , Combustion Air Supply for Furnace W/'U .S Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 4/04 Queensbury Building & Code Enforcement Arrive: am/ De art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial : NAME: Cer\qe-L-- _ PERMIT #: 7 LOCATION. � GG�� � INSPECT ON:. S I o . TYPE OF STRUCTURE: Y N N/A <,Rough Plum ' Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction 09-C�y A/q Pressure Test Drain / Vent ��/,�,�� Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head for 15 minutes Insulati D' Residential Check / Commercial Check ,.j9 71-L L Proper Vent, Attic Vent V ,44 Ak�c-1> Duct / Hot Water Piping Insulation If required unheated spaces .r— ` ���>�-`ire Combustion Air Supply for Furnace (� —/ Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\lnspection Forms'Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ctio, request received: 40°c Queensbury Building&Code Enforcement Arrive. - /' am/p am/pm , 742 Bay Road,Queensbury,NY 12804 Inspect° 's Ihitials: 1 L/ NAME: cofrl,eL ,.„ ,,, PERMIT#: � ~69L/ 7 LOCATION: v.40 +-..4— R(to I____--INSPECT ON: 0 TYPE OF STRUCTURE: W• 1A. `--,ICemgcrioloS Y N N/A COMMENTS Framin Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 `'A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour ire wall 2, 3,4 hour JFirestopping C 07.,- 6E-r' - ,44 AIC- -O�/> Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade - • Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: � pm D part: am/pm Date Inspection request received: _ Inspector's L1'/`— NAME: s •, PERMIT#: M(— 017 LOCATION: S `I' A` )�- DATE: S- Q-3- aP TYPE OF STRUCTURE: Comments Yes No /A / 5 Building Number/Address visible from road /1)6&(-7 b ti Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches t/ Roof Complete/Exterior Finish Complete V Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade �f�l� 6//Jl/tl Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers • 45m-(6— Grade away from foundation 6 inches with 10 feet 4A-A>6 inch clearance to sill plate b/g4-1 Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler _ Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%s"Gypsum Basement stairs closed rise>4 inches _ Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass E closur Final Electrical (/ r / Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final inspection J ,;Z Office No.(518)761-8256 Arrive: 1( ►i '(au''pm De art: am/pm Date Inspection request received: Inspector's Initials: . � NAME: Ces A)6 PERMIT#: _ -677 LOCATION: C-A-L6- A)7 p t p C-- DATE: S Z 7741 TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window _ Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site _ Oil Furnace shut-off at entrance to furnace area _ Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan _As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required0/1/1 / Flood Plain Certification,if required / 4 �T j L Okay to issue C/C or C/O [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection l Office No. (518)761-8256 Arrive: /), p i pian: am/pm Date Inspection request received: Inspectoi(s ials: NAME: C G' C PERMIT#: 0 ' ` 7 LOCATION: C-k4-57NJ l G�� a��� DATE: M9 • t' TYPE OF STRUCTURE: Comments Yesf No N/A Building Number/Address visible from road V Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches _ Roof Complete/Exterior Finish Complete ( '�h�_ (,�� 1 �� jJ I -j 11 Platform at all exterior doors " Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq. ft.vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s) installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched 0 T' 60 bvi- Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly /v �U� /p(A)c._ Gas Logs in Sealed or Glass Enclosure Final ElectricalkPLG�1 ( O /J Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if r..uire � ^�� Okay to issue C/C or C/ I [Temporary Permanent] i,J L:\Building&Codes Forms • • =• _ &Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc 1 L R l 6 - -C _..„.. Queensbury Building & Code Enforcement - Resident,al Final I, spection Office No.(518)761-8256 Arrive p art: am/pm Date Inspection request received: C-6 -06 Inspector's Initials: jZ/11 NAME: / PERMIT#: r 6j a1 LOCATION: sem" yi tl4iG{ _ DATE: _ j ��- TYPE OF STRUCTURE: lJ Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inche / s Roof Complete/Exterior Finish Complete ne56 _00./ 1E1'40 I C 1'1 0 Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more CIO Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inchesQ .`/4 Interior Handrails @ stairs 2 or more risers �CC— /C2�v/O 0 5 Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate _ Gas Valve shutoff exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazin&/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: • Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height),in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor,truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing 1%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical _ Final Survey Plot Plan As Built Septic Syste a.,ewer Dept.Inspe ' ker Site Plan /Variance qu 'd Flood Plain Certifica on,if -quired , Okay to issue C/C a C/0 emporary/Permanent1,/ L:\Building&Codes . ms :a ilding&C des\Insp tion Forms\Residential Final Inspection Form_revised_100405.doc , ':` Community Development Office - O `� ► `, 9 7 Town of Queensbury • 742 Bay Rd. ��• �- ''. ,:' ' Queensbury, New York •12804 PLOT PLAN IP Show all existing and proposed structures. Indicate the setbacks of all structures and buildings from all property lines. PROPERTY LINE a..fectrNur-tz,,,01,,,,„,,,,, _. . rg02141--- ,-.--,-,._,_ ,. , II , . • I l,- -1 I l, . . _ }_. : - 1 ! , , , 1 --, , i , 1 1 . —. + i 1 ,. _ 4 L-.- . II i r� { 71 . . _, iI F .--(9 • 1 - I 3 1 __ . i. . . . • 4jil i l ' Illi a ( Hill ' �4 1 I , i ; _ 1_ ;. • i 1 I I , , 73 i t -iCr I i ' O W ( 1 �„V( I CC 1_.._ .i._ _1 _ i J... { i j i + i r I 1 I I , , , , I i I 1 m W __ -_-'-- -- —a-_ CE 1 lallfl8 i i` ; ; i l 01.,; JN 1 I i 1 I , 11 { h�.•Qs � 1 l 2� 7 ;— _ i 1 1 3 �. -i - ---- .. __ _�_ .-I _ _ _-_i.. .. -1 k 1 , ; I i I L 1 I tiNr-or air Tro f? -/-1.44/,./ SIDE PROPERTY LINE /HO-.�itat'7'7E. IF '� /4e (-- - ivI1 SQUARE = 5— FT. / AZ-- // '21 AS I-11 - , I1H / AZ