2006-104 . ` TOWN OF QUEENSBURY
FAT
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20060104 Date Issued: Tuesday, February 26, 2008
This is to certify that work requested to be done as shown by Permit Number P20060104
has been completed.
Location: 37 WINTERGREEN Rd
Tax Map Number. 523400-302-017-0001-040-000-0000
Owner. BABS WAY
Applicant: BABS WAY
This structure may be occupied as a:
Residential Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, (DavP 4 4115t.
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
1
011614 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
111
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20060104 Application Number: A20060104
Tax Map No: 523400-302-017-0001-040-000-0000
Permission is hereby granted to: BARS WAY
For property located at: 37 WINTERGREEN Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: BABS WAY
37 WINTERGREEN Rd Residential Alteration
Total Value
QUEENSBURY,NY 12804-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2006-104
RESIDENTIAL ALTERATION (HUD PROJECT)
50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, March 15, 2007
(lf a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To ueensb ; Wednesday, March 15, 2006
SIGNED BY for the Town of Queensbury.
Director of Building:IF od;\nforcement
•
OFFICE USE ONLY /�/�
TAX MAP NO. 2O�111- l L/c PERMIT NO 0L 06/ - 70 7
FEES: PERMIT RECREATION ENGINEERING
(If applicable)
)1
PRINCIPAL STRUCTURE: 0: RYv' _C'
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJE T TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. c_ __ s ( '�
APPLICANT/BUILDER: f 1
k I O h(5+i' d iict (i 06 OWNER: —2--:-• ,
ADDRESS: .) . _� . .A,. et , •ADDRESS: 3 7 Lt) 44-P�✓ r e.- e Rd
PHONE NOS. E 1 7.51c1.—, 93 HONE NOS. v I l 5 C5 ' '
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE" e 'e C PHONE:��,�..�rn�, � H NE. g5 ��-� ��3
LOCATION OF PROPERTY: 1 t V I+'•l:i .i'sire.(� j?(-) . (:)\- LliQ /i CI-
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
APPLY TO YOUR Z O cr Q o 1-
PROJECT ~ O co up 0 W 00L O � . Q a =V
LL w O
F- o
Z Q Q LIJ CI -J �i-- JD NGO 8L° � iii0
SINGLE FAMILY / U eef\-64.Jf., /,4.1
TWO-FAMILY
MULTI-FAMILY(NO. )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR -.
INDUSTRIAL
ATTACHED MAR 1 t ZOOS
GARAGE(1,2,3)
OTHER I —/ __
f ;,
Town of Queensbury• Community Development Office• 742 Say Road, Queensbury, NY 12804
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: Please complete a separate Application
for"Fuel Burning Appliances&Chimneys"
HOW MANY FIREPLACE(S) AND/OR WOODSTOVES(S): available in our office
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION:
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I
certify that the application, plans, and supporting materials are a true and complete
statement/description of the work proposed, that all work will be performed in accordance with the
NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain
a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by
a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of
occupancy.
I have read an agree to the above--,
Signed
i()• 5-://
Director of Building & Codes: 761-8256 (for questions QUESTIONS? CALL 761-8256 OR EMAIL
regarding Building Permits, construction codes or septic codesaqueensburv.net
systems)
VISIT OUR WEBSITE FOR MORE INFORMATION
Zoning Administrator: 761-8218 (for questions regarding www•queensbury.net
required permits, the permit process, application requirements or to
schedule an appointment)
This application / proposed action described Permission is hereby granted to the above
herein is found to be in accordance with the Applicant to erect or alter the building described
zoning Laws of the Town of Queensbury. herein in accordance with said Application:
/0,A1 /‘
ZONING APPROVAL DATE BUILDING& O.' APPROVAL D E
J
Qv
Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804
0 (0 - /o (1
ELECTRICAL
All work is to be performed in accordance with manufacturer's instructions, NYS Building Code,
Local Building Code and attached ELECTRICAL SPECIFICATIONS.
1. Kitchen REC r—11,
► Replace existing ceiling fan/light with new flush mount style.'
► Remove dimmer and replace with toggle switch controlling light. ) 0 9 ;,; 06
► Test countertop receptacles and GFI protect as necessary.
• Provide dedicated 20amp circuit for microwave. T
► Hardwire light above sink to wall switch.
► Light on back porch is switched in kitchen and isnot operating, determine cause
and repair or replace switch and light.
2. Bathroom RLECc .
► GFI protect receptacle at vanity.
3. Hall
► Supply and install hardwired smoke detector on lighting circuit.
4. All bedrooms, total of 4
► Provide and install hardwired smoke detector on lighting circuit in each room.
5. Stairs Hall
► Provide and install hardwired smoke detector on lighting circuit.
► Repair or replace 3-way switch at top of stairs.
6. Basement
► Provide and install hardwired smoke and CO detector on lighting circuit.
► Replace broken porcelain socket.
7. Front Porch
► Remove existing flood light and replace with new porch light, owners choice.
GUELN6i3uk7 ()EP,RIMENT
-sed or. ole axaminatu. ; ci '
.Impliance with our comments LIST PRICE HERE $ OZ J
,,ot be construed as indicating
)!ans and specifications are in n
compliance with tt. Building Cci. VINYL SIDING
All work is to be performed in accordance with manufacturer's instructions, NYS Building Code,
Local Building Code and attached SIDING SPECIFICATIONS.
1. Replace missing pieces of fascia at left and right gables. `'v
Where bathroom window has been replaced, fill in with siding to match or soffit material. 1,-CD
Wrap exterior new doors and windows in coil stock, built out as necessary
LIST PRICE HERE $
Way 37 Wintergreen Road / 6
ar Dre.Lm er#
/Jrat
%J?v�l� b fit C�ri 0(4,,e< �,r
L/ a?; "j l�
WINDOWS
All work is to be performed in accordance with manufacturer's instructions, NYS Building Code,
Local Building Code and attached WINDOW SPECIFICATIONS.
1. All existing windows are double sets of triple track storm windows that need to be
removed. New windows will require stops as necessary and interior casings. (See
General Repairs)
2. Install insulated white vinyl replacement windows in the following locations according to
manufacturer instructions and attached specifications. Window U factor must not be
greater than .35.
► Livingroom (DH) 3
► Kitchen (DH) 2
► Bedroom 1 (DH) 2
► Bedroom 2(DH) 2
► Bedroom 3 (DH) 1
► Bedroom 4 (DH) 1
► Basement (Hopper) 3
Total Windows 14 - l
LIST PRICE HERE $
DOORS
All work is to be performed in accordance with manufacturer's instructions, NYS Building Code,
Local Building Code and attached DOOR SPECIFICATIONS.
•
1. Kitchen
► Install new pre-hung insulated steel 9 lite door unit (Stanley or equivalent)
► Install new white vinyl clad, wood core storm door (Larson 296SX or equivalent)
► Provide new entry lockset and deadbolt (Weiser or equal) keyed alike with entry.
► Finish according to manufacturers specifications with quality latex paint.
2. Front Entry
► Install new pre-hung insulated steel 9 lite door unit (Stanley or equivalent)
► Install new white vinyl clad, wood core storm door(Larson 296SX or equivalent)
► Provide new entry lockset and deadbolt(Weiser or equal) keyed alike with kitchen.
► Finish according to manufacturers specifications with quality latex paint.
Total Entry Doors <2
Total Storm Doors C e)
LIST PRICE HERE $ fi201
Way 37 Wintergreen Road 7
GENERAL REPAIRS
All work is to be performed in accordance with manufacturer's instructions, NYS Building Code,
Local Building Code and attached SPECIFICATIONS.
1. Windows
► Install new stops and casings for windows, 2 1/4" ranch casing, prime and paint.
2. Bedroom 1
► Repair door hinge.
3. Basement
► Replace missing strike plate and stop for door leading into basement.
► Replace lockset.
► Remove basement stairs, install new PT stringers, treads and risers , open style.
► Add small section of handrail at top of stairs.
5. Front Porch
► Remove existing awning and wrought iron posts and rails.
► Create new gable rood, dormered into main roof, maintain consistent line at fascia.
► New porch roof shall cover same area as existing awning.
► Shingle new porch roof into main roof with ice and water shield at valley.
► Wrap porch fascia to match house, finish soffit and ceiling with vinyl.
► Install new PT 4" x 4" posts, railings for porch and steps with 2" x 2" balusters.
LIST PRICE HERE $ ea-v �+k''1�
Extras
1. Identify additional separate cost to install or remove additional items not mentioned in
specifications that may be necessary to comply with code and complete the job in a
satisfactory manner and list separately here.
2. Items not listed as additional are assumed to be included in contractors bid price.
LIST PRICE HERE $
.\ r�
I ;�
Way 37 Wintergreen Road 8
83/86/2086 21:32 7986681 PAGE 05
fisting asbestos mold lead consulting
ILEADSAFIE
e n v i r o.xi m e n t a l
r-.
FLOOR PLANS
37 Wintergreen Rd., Queensbury, NY
Bath
Kitchen 1 Bed#1
Bed#2 Stair Bed#3
Hall
1 1 1
Living Room
1 1 1
1
Street Side, Exterior Side #1 Second Floor
First Floor
Offices in CT and NY • 800-392-6468
29 Bank Street • Stamford, Connecticut 06901 • Fax: 203-'921-4145
47 Spring Street •Newington, Connecticut 06111 •Fax: 860-232-5703
2840 Broadway, Suite 323 • New York, NY .10025 • Fax: 845..566-6913
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: 07: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: b PERMIT #: 0���f4
LOCATION: ��1 . -,•("),(Y � � INSPECT ON: 3 --a?-0
TYPE OF STRUCTURE:
Y N N/A l D
PVC: R-1,R-2, R-3, R-4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 1/2 inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
)
oper, CPVC,Pex One and Two-Family
sulation/Residential Check/ Commercial Check '1,0
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L:1SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Repott.doc November 17,2003
)AAF1I
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: tr0 )(0
Queensbury Building&Code Enforcement Arrive: am/pin Depa- •m
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:0, L\rk, Z1
NAME: ( 645S S (,!/i PERMIT#: 0 / J V G
LOCATION: 3-I 1A,V\r\ k- C ri,��, INSPECT ON: MAK,
TYPE OF STRUCTURE: J
Comments
r u\-\_ T roc \ 2_ _ / k
Y N N/A t.I t . D
—
ootings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
COMMONMain Office 176 Doe Run WEALTH ELECTRICAL INSPECTION SERVICE,INC.
Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE
- ELECTRICAL APPROVAL
Panel Board No.,,.{vdk
Cert. �f
j'� 6 6 8 71 Cut-in C
Owner.... ld..If �?......
Card ..Q,�
Location... �l�' au•`f/4�' ............ ..... .................
............... ...
........................ ....
Installation Consisting1I� 'QV 144
.�-`=r.�'7f ...................... ....G... ..
rte << : �G............ai.... •7...5 i.�144.1,... . fit, { ............. .....
- r f -tl.F.;. T L
..... -rte
•
s
Installed B ... ...Lic........N.................. s
y.. ......... C.tic.,�ltsys� .......
iob-
The conditions following gkificl the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules are violated,the Company shall have the right to revoke this rtifi ate.
Date. fv. .fd. -
.... INSPECTOR „gc<:
.............................
•
Mem r N.F.P.A.,LA E.I.
Queensbury Building & Code Enforcement - Residential Final Inspection
1
Office No. (518)761-8256 Arrive: am/ d�, epart7 \7("c am/pm
Date Inspection request received: Inspector's Initials:
NAME: Pirt. PERMITh #: _ 0.4, " 0
LOCATION: ,`' (i N ' ee DATE:
TYPE OF STRUCTURE:
D-se....5 fill Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches 3// /O7
Roof Complete/Exterior Finish Complete
Platform at all exterior doors -- pc/I/itGuards at stairs,decks,patios more than 30 inches above gradeGuard at stairwell at 34 inches or more0.)0 i r /er
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall �� -3 // 44.7.
'
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet :. e 2- ' ® r Ce..
6 inch clearance to sill plate )`
Gas Valve shut-off exposed/regulator 18 inches above grade `� j /
/07
Interior privacy/trim/doors/main entrance 36 inches Q
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom: C-4,.‘7L'A'S'�Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector 7C0Q 1— 26-1
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq. fl.-150 sq.ft.ventsV Z\rr-"t
Bathroom Fans,if no window _ J
Plumbing fixtures Ft�,r '(�J� "�`/'a i Z '
Foundation insulation �
Floor truss,draft stopping finished basement 1,000 sq. ft. IK TSF- � ,F
Emergency egress below grade Vel ,s
Gas Furnace shut-off within 30 feet or within line of site �2,�`�i�,LL,M---
Oil Furnace shut-off at entrance to furnace areaMA
Furnace/Hot Water Heater operating Vic/4-1)
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110 e��%�` "�
Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched ek-' ��I ' S Rk''V4)413
Garage fireproofing/'/<hour fire door/door closer l
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure ?c-- ),_354C---6,-----'—
Final Electrical W-a) ` '
Final Survey Plot Plan ���i- �-/
As Built Septic System/Sewer Dept. Inspection Sticker /- J 1...514 {" �_% �7
Site Plan /Variance required "�'
Flood �_—
Plain Certification,if required
--5 o 9
Okay to issue C/C or C/O [Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc
Queensbury Building & Code Enforcement - Residential Final Inspection
r
Office No. (518)761-8256 Arrive: am/ptn Depart:tem/pm
Date Inspection request received: Inspector's Initials:
NAME: i tjPER #; 'I
LOCATION: ` _ DATE:
TYPE OF STRUCTU
Comments
Yes No NIA /i -/Building Number/Address visible from road
Chimne Hei ht/"B"Vent/Direct Vent Location
1/1/ f e ` /
Y g . r
Fresh Air Intake C "'
3 •
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete kikr 3A: 0-
Platform at all exterior doors / Q
Guards at stairs,decks,patios more than 30 inches above grade 2A_ !!F (�C� Se" [�`
Guard at stairwell at 34 inches or more ""NVV
Guard at deck,porches 36 inches or more (y/j
Handrail Termination at Newell Post or Wall (/-. d (� ]-
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate w. -
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors: FIX--4-5/0"Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup: 175 < Q �C�`
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area -�
1
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq. ft.vents ��
Bathroom Fans,if no window 4
Plumbing fixtures
Foundation insulation
Floor truss, draft stopping finished basement 1,000 sq. ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site OK)Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating FA4)46' i3?- 16‹—
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'A"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'/4 hour fire door/door closer
Duct work Sealed properly
Gas Lo si.s.maie4 or Glass Enclosure
Final Electrical
i of Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required `
Flood Plain Certification, if required
Okay to issue C/C or C/0 [Temporary/Permanent] _
L:\Building&Codes Fonns\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc
'f—f-ZA A-1(
Queensbury Building & Code Enforcement - Res': - r.ti. nal Inspection
Office No.(518)761-8256 Arrive: z„:46---- i_ ) epart: � pm
Date Inspection request received:
) Inspector's Initial, ,a v
NAME: 4-5y /
IT#: t:.-3' '' *
LOCATION: 37 VAtt IId I fZ�R KJ .)ATE:
TYPE OF STRUCTURE: IA c.r ) 17 _I A3
Comments
1 Yes No N/A
Building Number/Address visible from road
Chimney Height/'B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum I/2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/' hour fire door/door closer
Duct work Sealed properly ____
^.A 1gs in ealed o lass Enclosure _
i1 Final Electrical \///
'-y 'lot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required `
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
Queensbury Building & Code Enforcement - Residential 'nal Jos ection
Office No. (518) 761-8256 Arrive: a ; Cde am/pm
Date Inspection request received: Inspector's In't :`,/✓-
NAME: PERMIT#: 27
LOCATION: - t- 1 _��,�� rr' .t DATE:
TYPE OF STRUCTURE: ✓ '
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height I"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy I trim/doors I main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed I Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Perm•.-
L:1Building&Codes Forrns\Building&CodesUnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008