Loading...
2006-105 TOWN OF QUEENSBURY 742 Ba Road Queensbury,NY 12804-5902 (518) 761-8201 �� Y ,Q �', Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060105 Date Issued: Monday, February 25, 2008 This is to certify that work requested to be done as shown by Permit Number P20060105 has been completed. Location: 5 REARDON Rd Tax Map Number. 523400-289-007-0001-006-000-0000 Owner RALPH & DEBORAH GRANT Applicant: RALPH & DEBORAH GRANT This structure may be occupied as a: Fireplace By Order of Town Board Residential Alteration TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060105 Application Number: A20060105 lax Map No: 523400-289-007-0001-006-000-0000 Permission is hereby granted to: RALPH& DEBORAH GRANT For property located at: 5 REARDON Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RALPH&DEBORAH GRANTPATResidential Alteration $200,000.00 BOX 82IA WARNER Total Value 5200,000.00 BOX 82 CLEVERDLAE,NY 12820-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans& Specifications 2006-105 2760 SQ FT RESIDENTIAL ALTERATION • $276.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, March 20, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow o ensb , s d`1 , March 20, 2006 for the Town of Queensbury. SIGNED BY Q ry Director of Building&Code Enforcement Building Permit No.: 2006-105 APPLICATION.FOR A TEMPORARY CERTIFICATE OF OCCUIPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at: 5 Reardon Rd For the following use(s): Single Family Dwelling I understand that if the conditions that follow are not met before the expiration date, the deposit is forfeited. ,, . -56?"-- tet-4--q- Sig fiat / e of A li / g pp icc�nt Date A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby fI APPROVED n DISAPPROVED with the following conditions: 1) Complete siding 2) Complete rails & guards 3) Complete rough grade 4) Complete insulation 5) Need fireplace final 6) Need final survey FEE: 0 $10.00 DEPOSIT: / $100 RECEIVED ON: 8/24/07 14 , . : A t2 Director of Building & Code Enforcement* Date of Issuance** *This Certificate is NOT VALID unless signed by the Director of Building &Code Enforcement or his designee **This TEMPORARY CERTIFICATE OF OCCUPANCY expires 60 days from the Date of Issuance Community Development Office ; OCT Town of Queensbury • 742 Bay Road • Queensbury, New York •12804 pate X06 Marilyn Ryba, Executive Director• David Hatin, �' L_ S3UN� y � Director of Building&Codes Tb EIJIi_�It.l;;,1IVCl CODs Craig Brown, Zoning Administrator•Michael J. Palmer, Fire Marshal -tr-- ----�___ r � APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building &Codes Office for the issuance of a Building & Use Permit pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE� TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED. j OWNER: l? ` if C7 r)/4 j �,I.NSTALLER/BUILDER: J/-�°7L: ADDRESS: , A.EI iµ, /15 14. L fl-l2� ADDRESS:J S F..- PHONE <PHONE NOS. kS&" 3 V b 376.-- 6H ; 6 PHONE NOS. 5-1.'fr LOCATION OF PROPERTY: 1 QTR? t�t) /fib �/ 42r Bp(VISION NAME: "�/ LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: � �Lrr4k 2) ,✓SwE. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: P421 pi/ L`8,01,4''7 PHONE: £'C/ r V(9 ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORINATION STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE (GARAGE ONLY) IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: r2Vyn5'61\1 MODEL NO. LISTED BY: NUMBER: QUESTIONS ? CALL 761-8205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK. STONE OR EMAIL: f remarshal(a�queensbury.net MASONRY`. CHECK ONE ✓ VISIT OUR WEBSITE 71LE STEEL SIZE IN FOR MORE INFORMATION / INCHES www.queensbury.net FLUE CHECK ONE ✓ DOUBLE TRIPLE WALL INSULATED DIRECT VENT CI=IIMNEY WALL LNER CHIMNEY MATERIAL CHECK ONE ✓ **IF NON-MASONRY, PLEASE PROVIDE: MANUFACTURER NAME: Ai 07— gin'los"." MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION &BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. OFFICE USE ONLY , e"''--' TAX MAP NO.___________PERMIT , ---- PERMIT NO. ' ' ; • PERMIT FEE ; APPROVALS: ZONING ; • TOWN CLERK ' ' '_______________________________________� ;........._..____..+._ APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT;• A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW PERMIT. � BEFORE ISSUANCE OF A VALID OWNER: oley .. /6"/4/?�,z. i2_. • INSTALLER: _ 2K 4'x 2 L gtrF Nl 2-6z� IADDRESS: =.. _.. - '�r. �? ADDRESS; (_t G se- 3,-/6 I PHONE NOS.(6° -) .��:j - ,.4; s6 PHONE NOS. LOCATION OF INSTALLATION: j / 6,24%v-,--e";-,i7 /e-e4.Q/ YEAR BUILT NO.OF X COMPUTATION= RESIDENCE INFORMATION: BEDROOMS _"................,..".. "'""""""'""~'~�'•• = TOTAL DAILY FLOW 1980 or older X 150 GARBAGE GRINDER --~-1-9-•-•••••-".."..."......... gallon per bedroom = 1981 -1991 X 130 gallon per bedroom, = INSTALLED? =i/s.' 1992-present """"""'"""'""_"'• SPA "..,..........."» Y X 110 gallon per bedroom mOR HOT TUB � � .7.74„....2_7.7............ " r�'�r"r "'" ~ SAO INSTALLED? (45.47 PARCEL INFORMATION:��' ✓ TOPOGRAPHY: FLAT ROLLING --.. L STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND ' LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? WHAT DEPTH? >6 ' BEDROCK/IMPERVIOUS MATERIAL: AT > 6 ✓ DOMESTIC WATER SUPLY: MUNICIPAL . WELL / (IF WELL: WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS>X00 FT ) ✓ PERCOLATION TEST: RATE IS / ' MIINUTE PER INCH COMPLETED BY A LICENSED PROFESSIONAL ENGIN EC ECR OR ARCHIT (TEST TO BE T) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANK: 77-5-6- GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH e- FT. ✓ TOTAL SYSTEM LENGTH:?>C FT, SEEPAGE PIT(S): HOW MANY? ✓ SIZE OF EACH / FT. X / 25 FT. - / '-?2f ,' Te BE uta ✓ SIZE OF STONE TO BE USED: # HA— /DEPTH OR THICKNESS /''q FT. ✓ BED SYSTEM SIZE: //4 X /1/// • ✓ ALTERNATIVE SYSTEM: ________ _______LENGTH AND/OR SIZE /''1 ✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: A`'4 /SIZE OF EACH A/4. ✓ GALLONS,/TOTAL CAPACITY:: /`A GAL. } NOTE: ALAHM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN 11 APPROVED ELECTRICAL INSPECTION AGENCY. „.............. �, ..,.,. . . PLEASE REVIEW LIST PROVIDED. For ............ .......... ................... ....... ..... ................:.................:.„.,..,,....,.,.,,,.....,..............,:...,.,.,.,.,,......,...,.y � your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by.or on behalf of an applicant, shall be void, I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 781.8258 OR EMAIL Queensbury Sanitary Sewage Disposal Ordinance. aodesoaueensbvrv.net ---.l -' VISIT OUR WEBSITE FOR MORE INFORMATION = ,h ��=. ?/2 C/ www.ctueensburv.net Signature of Person Responsible Date eaTown of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 OFFICE USE ONLY TAX MAP NO. PERMIT NO. 0 '/_.3)6 ; c 4 FEES: PERMITS".) RECREATION ENGINEERING 'SUR (If applicable) ItC�trCc .5 ndtvrt -� PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILD '4G ERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: gm 670.4N; OWNER: 4r-704 fl -PE-LW 11-N- t<2"4a ADDRESS: 7a k �z g 1-61-1641{ 11ADDRESS: Cekry5 PHONE NOS. 341.9 ?'V " 3L PHONE NOS. CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: CEA. 7- 6''U PDA-7) , Q�E z/ 34..Ry ReedSUBDIVISION NAME: 4icfio�'�- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p CJ o APPLY TO YOUR Z 1= O w cWn PROJECT R.0 < 0 OJ • w aO = v H o HF-: oO W 0 CW — Z Q Q r N Q O ►l. n. 2 o6 SINGLE FAMILY � r w ` / 3190/ 7Jl> l z,Z TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE ETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER , IF COMMERCIAL OR INDUSTRIAL— NAME OF BUSINESS: A ESTIMATED CONSTRUCTION COST: i~. Please complete a separate Application for"Fuel Burning Appliances&Chimneys" available in our office HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? I. I IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: E L v r. ' ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 11 ta Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 • l OFFICE USE ONLY • TAX MAP NO. . ` / — PERMIT NO. ..)_00(0—/(;) ; FEES: PERMITU, C'el :ECREATION ENGINEERING (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. l 1 Re (�� � APPLICANT/BUILDER: ra I �V1/J�A ie OWNER: 0-111C (� (Pot Bo x I _ ADDRESS: Cie ve l-c��z.(c� N/ /2 �20 ADDRESS: J . /nE PHONE NOS. -157?--(� lp-311PHONE NOS. Sa E_- &&(/)"2-21g, 44%3— Pa+ bth rve / CONTACT PERSON F UILDING & CODES COMPLIANCE: kl bra 04HONE: r� /of { ? LOCATION OF PROPERTY: Rea ic/z)n Vd; l L0'1- 4r I e N 11 ( a) S ur SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z APPLY TO YOUR z c p W LL PROJECT0 0 OJ • OLLI LL = _ W 0 J LL y 0 2 d I- I- cc W - Z < < r U) N U) LL- o_ SINGLE FAMILY ► `� I Cif"hi e5 ✓ 11-11,00 13ao, all00 Ifo 11 ht TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: NiA ESTIMATED CONSTRUCTION COST: \-• A'? 76j De° - Please complete a separate Application �St I for"Fuel Burning Appliances&Chimneys" HOW MANY FIREPLACE(S): A /OR WOODSTOVES(S): — available in our office ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? ;q0 IS THIS A HISTORIC SITE? 140 PROPOSED USE OF BUILDING OR ADDITION: I CCI a)I)l, feS(cE ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? D Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE EASEMENTS ON PROPERTY? N O I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed -- .�-GLh. J 1�ttc'A Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with sad zoning Laws of the Town of Queensbury. Application: /C N BUILDIN & ?0ES APPROVAL ZONING APPROVAL .3 n DAT DATE - QUESTIONS? CALL 761-8256 OR EMAIL codes@queensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net f °' Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury,NY 12804 3 roD Foundation Inspection Report 3 Office No. (518)761-8256 Date lnspgction request received: Queensbury Building&Code Enforcement Arrive: �j� i/ ip j� Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's ifiitIals• l�L NAME: _ �,t,� //JKe PERMIT#: LOCATION: S e,fac(e i _ INSPECT ON: TYPE OF STRUCTURE: Comments Cr�� \ Y N N/A Footings Piers / Monolithic Slab Reinforcement in Place The contractor is responsible f6r providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Reportdoc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. (518) 761-8256 Date Inspecti request received: Queensbury Building&Code Enforcement Arrive:// am/ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials/� � NAME: ( 'R.447— PERMIT#: O� —1° LOCATION: r1FP- ') R� INSPECT ON: ///2,8//e9-6 TYPE OF STRUCTURE: Comments / Y N N/A FootingsAAP T &.9- Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. (518)761-8256 Date Inspectionr�ec uest received: Queensbury Building&Code Enforcement Arrive://1/S am/pq/ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspec o s Initials: NAME: (�ie�9N% PERMIT#: LOCATION: — ReArPQD4-i RR INSPECT ON: ///2` 706, TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place Po ,AX / `- The contractor is responsible for providing protection from freezing for 48 hours following the placement ���� of the concrete. Materials for this purpose on site. Foundation/Wallpour R ' fo - a in Place Footin Dowels 'r Keyway in place 7 Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /0 --/2 1/ /2/,? Foundation Inspection Report Office No. (518)761-8256 Date Ins tin} uest received: Queensbury Building&Code Enforcement Arrive: / 6n/p`n ' � Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspect is Initials: , �' _ NAME: PERMIT#: a6.-/Ds- LOCATION: Tult#5510# S / r- yy INSPECT ON: TYPE OF STRUC Comments Y N N/A Footings Piers Mono1i hie Slab— Reinforcement in Plac� -contractor"is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour O 1 6 C"419 1( Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. (518)761-8256 Date Inspection r q est received: Queensbury Building&Code Enforcement Arrive:/2, /pm % Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector s Initials: ,)/1r NAME: C-- RA-A-1— PERMIT#: CY9 'tel 0 3 LOCATION: igE–���,a ) Rjz _ INSPECT ON: V241:310 Com' TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place1././ Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /-� - oma /z/( Foundation Inspection Report Office No. (518)761-8256 Date Inspectigtg request received: Queensbury Building&Code Enforcement Arrive: /. / V am/pm j)C_Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspectdr's Initials: (---\(' NAME: r��'�-�- PERMIT#: (/tj 'lO 3 LOCATION: 75—M?,r-k INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing �--6 til-pgly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 R. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspegpion_ nest received., Queensbury Building&Code Enforcement Arrive: II ,?j 7am/p rt: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: 67c�� I PERMIT#: 06' Ci, LOCATION: fe 'if/ t-' /C) , INSPECT ON: Ent C5 7 TYPE OF STRUCTURE: / Y N N/A COMMENTS Framing Attic Access 22"x 30" minimum -.(1.6- G/AI- y=0/Q 0 C Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 11/4(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inf.eco. request received: Queensbury Building&Code Enforcement Arrive: IF am/ Dart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto 's Initials: `! NAME: VRty, + PERMIT#: LOCATION: 7rO ti Pb INSPECT ON: .� TYPE OF STRUCTURE: Y N , N/A p COMMENTS / Framing r` Attic Access 22"x 30"minimum / C,IA` A? IL16-1 Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Insptsscfion,request received: Queensbury Building&Code Enforcement Arrive: (C. m-/p} epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:VI NAME: �� PERMIT#: LOCATION: 7 INSPECT ON: ® may-7 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses ` q An or Bolts 6 ft. or less on center ce and water shield 24 inches from wall . � 9 Fire separation 1, 2, 3 hour 1>(___C----1-6— A5 Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report 111'J.4) Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: /i /S am//pr�fi part: am/pm /� 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: V/ V NAME: ��A l PERMIT#: � ' __ /6., LOCATION: i-g- c-AJ itINSPECT ON: J®`' TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge(8) 1 6D nails each side Draft stopping 1,000 sq. ft. floor trusses 67 chor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall �c /3 .( 2 Fire separation 1, 2, 3 hour l� `�'l Fire wall 2, 3,4 hour Ni Firestopping (j��( � Z Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Insp ction r_Nuest received: Queensbury Building&Code Enforcement Arrive: S am/pi , pepart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector' Initials: 'ft' NAME: (b/EVA) PERMIT#: j 6✓ ` 1 1 LOCATION: ,€64ye O kj0 INSPECT ON: 4/11:0" TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Dra stopping 1,000 sq. ft. floor trusses Prnerl chor Bolts 6 ft. or less on center ce and water shield 24 inches from wall Fire separation 1, 2, 3 hour ent,— P.6/ C Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspectionrequest received: Queensbury Building&Code Enforcement Arrive: . '3( m/ m Depa : am/pm 742 Bay Road, Queensbury,NY 12804 Inspector"s Initials NAME: PERMIT#: C% `/0 LOCATION: /L-f 2 vis-?/0 INSPECT ON: .1/67 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '//(w) 16 gauge(8) 16D nails each side Draft topping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Tivir3 Foundation Inspection R port Office No. (518)761-8256 Date Ins tion request received: Queensbury Building&Code Enforcement Arrive:4am/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: � ,� PERMIT#: /OS— LOCATION: peay-d-T-„ Z 4 . INSPECT ON: TYPE OF STRUCTURE: Comments - Y7 N/A Footings Pi Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Bullding&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing/ Firestopping Inspection Report Office No. (518)761-8256 Date Inspecti95 requestreceived: (i0/0, Queensbury Building&Code Enforcement Arrive: vl am/ m Depart: am/pm V 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: ep20PERMIT#: oa / LOCATION: 5 R(9 / 12 q(,-/ INSPECT ON: 7 TYPE OF STRUCTURE: Y N N/A / 1g/7/7�2 Framing — — — COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center e and water shield 24 inches from wall V. Fire separation 1,2, 3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report /l/- Office No. (518)761-8256 Date InspectiIr quest received: Queensbury Building&Code Enforcement Arrive: Af p -5/1 Depart: amlpm 742 Bay Rd.,Queensbury,NY 12804 Inspector's itials: NAME: vIZ/1 N I PERMIT#: LOCATION: eRG,4 J vnJ vQ1- INSPECT ON: Cpl /C.) 2 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Septic Inspection Report Office No. (518) 761-8256 Date Ins jequest received: Queensbury Building &Code Enforcement Arrive: `� 0 am/phi pepart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: V NAME: r9/z,cN'r PERMIT NO.: ( J) LOCATION: I-C='A+2Q&4) 9(D INSPECT ON: ����iP RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. 5It rC- Cly/4- Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: - -�--- x Stone Size: Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y/ N/ Partial End Cap I Inlet/Outlet Pipes&Baffles __ Y N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built �...Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: , pA proved artial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 7-/7 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p Depart: '111117-am pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 6( 1 ,\JI PERMIT #: 06 — LOCATION: R--Rx/di-vv (Z-1) INSPECT ON: c TYPE OF STRUCTURE: VN N/A "Rough Plumbing Nail Plates Plumbing Vent - • '• ' ace 1 '/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction 4iressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (5l 8) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pr Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: "f NAME: (9j AAf-r PERMIT #: 696 — 40,E LOCATION: 2C--4,e,dv,J ko INSPECT ON: G z6 (7 TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2, R-3, R-4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place 1/4)G�,�u_ /vl Rough Plumbing/Nail Plates ✓ 1 '4 inch min. Drain Size PC--A11:—/- Washing Machine Drain 2 inch min. 0A-tL /rW�� 5 Head or Air Supply Test `7 Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes eanout every 100 feet/change of direction ater Supply Piping Cooper Commercial 7 Cooper, CPVC, Pex One and Two-Family Insulation/Residential Check/ Commercial Check _ Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape , COMMENTS: L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Repoit.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date IinspectioRrequest received: Queensbury Building&Code Enforcement Arrive: JL am/J(4\ epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: Ile_ e_ NAME: 04/0 r PERMIT#: 40` 71'ff- LOCATION: /c" -4Z0b.A.} INSPECT ON: " A;Yt`, TYPE OF STRUCTURE: / Y iyN/A COMMENTS Framing Attic Access 22"x 30"minimum rit)LL y ,�,, / i I /„f 66,,{ 5 Jack Studs/Headers /� I ' Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 ''A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour ire wall 2, 3,4 hour Firestopping 4.(&&-trQ P /4' ! Penetration sealed 16 inch insulation in cavity min. 012C— �O J�5 Garage Fire Separation ei1House side V2 inch or 5/8 inch Type X PLS lt Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: • S G Queensbury Building&Code Enforcement Arrive: am/pm Depart: Ili am/. 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: (tj... ç) 67 A-11\i PERMIT#: LOCATION: nr. tz I) INSPECT ON: ROW G TYPE OF STRUCTURE: VN NIA COMMENTS gaming Attic Access 22"x 30"minimum 4i:;ib 5`'%/4/v 4/131)./)`2 Jack Studs/Headers Bracing/Bridging /OA- = � ��1`5 Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'A(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses I� Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour 14"5° Firestopping p61 1' 6Yr Penetration sealed _ 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:/vvr-am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: /f ilk NAME: < n PERMIT #: 1°ZL. LOCATION: ') INSPECT ON: cJ TYPE OF STRUCTURE: Z.50 1 Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size _ Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check 1/ Proper Vent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: . 1‘)TUA5 4:3t 4 -4 1\41"- --41'R . /Alt__, $(4-e,e‘15‘ L:1Pam Whiting\l3uilding&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Ckinsat Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p epart: ` i am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: � � NAME: (2"[Ce_A-/--- m PERMIT #: � -`C"'C LOCATION: veil) Kehyteke3CeINSPECT ON: L. TYPE OF STRU a•RE: `6-6 i.; ,fccit), Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes _ . Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insula i Residential Check / Commercial Check Proper ent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace ,k4_ Duct work sealed properly / No duct tape VQVcL '(/ COMMENTS: L:1Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ art: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspecto s Initials: `� NAME: CD24A1 r PERMIT NO.: 061 - LOCATION: 61 -LOCATION: 2/4, � INSPECT ON: IW arr RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/ Clay Type of Water: Municipal/Well Water Waterline separation distance _ ft. _ Well separation distance ft. Other wells: .. . _._ .. . ft. Absorption Field: Total length ft. Length of each trench ft. � Depth of trenches _ .ft. , C CII,e, / oti Size of Stone Seepage Pits: Number Size: - ----- Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y/ N/ Partial End Cap Inlet/Outlet Pipes&Baffles —Y— N Location / Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan __Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: ?proved artial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 ?-/Z-L3. /0?- Mov-e/6.2A7 Town of Queensbury Fire Marshal 411111A 742 Bay Road 001Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Wood Burning Fireplace/ Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# 1,40-' Schedule Inspection 143* /Time — am m anytime Inspector frOA� Name /c, rG 1--- Address 5- LxrP(1`7 L,. I v' . Rough In,.-\*"."Final Appliance Manufacturer_ 6/54/7 Model# E�Y 36 749 Masonry Chimney Factory Built Chimney .( Flue Size Double Wall _Triple Wall Insulated___ Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) ../k/ regh.41 0e4z-16 Safety Strip Installation (fireplaces only) X er' !d '44" Firestop(s) Vertical Chase k Wall Penetration Chimney Clearances to Combustibles Chimney Termination t 3 feet above roof penetration; 2 feet above any combustible construction within 10 feet Combustion Air R b),42-.+ Hearth Extension rzza. pfile_— t sFireMantel (height above f/p opening) I5- Fireplace, place Doors I Screen (required) White—Building Dept. Yellow—Customer Pink—Fire Marshal Septic Inspection Report Office No. (518) 761-8256 Date Ins • n uest received: Queensbury Building &Code Enforcement Arrive: 1 4 am/pm ,)epart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: 1' — 06" -- 105 NAME: CO r PERMIT NO.: ) LOCATION: i4/QO �C�) INSPECT ON: 7/ �D'7 RECHECK: 6666 Comments and/or diagram Soil TypeSan / Loam/ C 14-6 Type of Water: Municipal/ Well Water / ' Waterline separation distan ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench _.._. ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x ---- Stone Size: f4-AJ(L &.4,C--&("t-C") Piping Size Type Building to tank a r Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y/ N/ Partial End Cap Inlet/Outlet Pipes&Baffles ____Y N Location/ Separations Foundation to tank /IA'r' rol-/LJ . ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan __Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Mi a Rear System Use Status: pproved artial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Wood Burning Fireplace/ Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance. No deviation from the manufacturer's instructions or specifications is allowed. 61( Permit# C—/ ' Schedule Inspection 7 J-3D/'t(. 7)rime 1� a,Cnm anytime Inspectorp Name (' 4PrT Address k Rough Ino Final Appliance Manufacturer Model# Masonry Chimney Factory Built Chimney Flue Size Double Wall Triple WallInsulated^ Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Safety Strip Installation (fireplaces only) Firestop(s) Vertical Chase_ Wall Penetration Chimney Clearances to Combustibles Chimney TerminationVdr,gIA (*(41 3 feet above roof penetration; 2 feet above any combustible construction within 10 feet Combustion Air Hearth Extension /2:1tiC*1-4 Mantel (height above f/p opening) )\-/ v) a'f4r14er Fireplace Doors /Screen (required) White—Building Dept. Yellow—Customer Pink—Fire Marshal i .-- 3 1,.)&ip..,,-Z1 . Septic Inspection Report Office No. (518) 761-8256 Date Inspecfi_'o9 request received: Queensbury Building &Code Enforcement Arrive: am/pm D art: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspect° s Initials: NAME: 6 r`_ PERMIT NO.: 0 ilik LOCATION: gi INSPECT ON: 7 ..-- r dar RECHECK: Comments and/or diagram Soil Type6and1Ll a Type of Water: Municipal Well Water Waterline separation distance ft. Well separation distance 7' ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches , ft. Size of Stone l� i i t-"f R&-(O& .3 r<i • Seepage Pits: Number Size: x Stone Size: _ Piping ly, TYpe/a Building to tank ,,�p/5' Tank to Distribution Box b H Za Distribution Boxt eld/ Pit ,' i( Opening Sealed:N/ Partial / End Cap ,,,/// /� ISA-<_k Pipes &Baffles Y vf( Location/ Separations Foundation to tank Z P ft. ,q K44) Foundation to absorption if ft. Separation of Pits ft. Conforms as per Plot Plan N Engineer Report and As-Built �,._.Y,N Location of System on Property: C Act ��K<<K rout Rear Left Side Right Side Middle Front Middle Rear System Use State . ______4pproved artial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 (7',.7r— _ ueensbury Building & Code Enforcement - esidential Final Inspection —1/ (� r Ciffice No. (518)761-8256 Arrive: -t. V am/pm Depart: am/ m Date Inspection request received: _ Inspector's Initials: „let...,L-' NAME: //'' � ��Y �1 PERMIT#: LOCATION: , PSP ie I.....— _— , _ DATE: =� TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road /1,kr G Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors DA Guards at stairs,decks,patios more than 30 inches above grade I - - 4-1 L� Guard at stairwell at 34 inches or more y/�C Guard at deck, .orches 36 inches or more Handrail Termination at Newell Post or Wall J E Interior/Exterior Railings 34 inches to 38 inches /4;4-z_�C�- Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 41111r //ti 64e ( (4 6 inch clearance to sill plate `t Gas Valve shut-off exposed/regulator 18 inches above grade ( -'-- Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: I) Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sq. ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched /7/ . Garage fireproofing/3/4 hour fire door/door closer 00,00d--1.0 �j q� K Duct work Sealed properly _ Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan 11/ As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Li Flood Plain Certification,if required j •1 0,,, Okay to issue C/C or C/0 [Temporary/Permanent] 0 , L L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc /0- 2 "725 e-s Z:yrt • Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: ILam/pm Depart: am/pm Date Inspection request received: Inspector's Initials: 3 R'/ NAME: _6ra uPERMIT#: LOCATION: iso .---3 • DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road C/O Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation _ Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer _ Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker _ Site Plan /Variance requiredf—rr Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent J L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc . 2-4. . kWre5dal . a-)E- _ Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive; r am/pgi Depart: am/pm Date Inspection request received: Inspector's Initials: Jj�(� NAME: PERMIT#: Q C l . LOCATION: �p49y-0491^ ,Rd, DATE: V-27-07. TYPE OF STRUCTURE: Comments Yee No NIA Building Number/Address visible from road , r 7:- Chimney Height/'B"Vent/Direct Vent Location / LA......, C/OFresh Air Intake ✓/ p 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete C,..x,,/3.67' ' �Z" ' Platform at all exterior doors ,p S Guards at stairs,decks,patios more than 30 inches above a •de A. �9YGh �C tht � Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet '`t Lbw 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing AkD 124,,,yA+f:7612 (r4-4e, .4 7-- Interior Smoke Detectors: kAAA* • 041-1-t ge i 1_5 Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures / // Foundation insulation /ti -titG� (�S.0 L Floor truss,draft stopping finished basement 1,000 s..ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area v Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 ..1- Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched of Garage fireproofing/3/4 hour fire door/door closer V Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure _ 4 Final Electrical ''/ed- f(4/4 - Lc_.G�- Final Survey Plot Plan U■ 6v841,l l ivAlle As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required ` Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building &Code Enforcement - Residential Final Inspection Office No. (518)761-st ?5 2//0`7 Arrive: �,b t6 am/pme, : am/pm Date Inspection request received: ' I( ( Inspector's Initials: Ch r•r" NAME: QG ly�Jtv t PERMIT#: 0 6 /6 LOCATION: 6 Gy, [-?_.6 AO' DATE: Y./-? 07 TYPE OF STRUCTURE:' Comments Yes. No N/AG1(• Building Number/Address visible from road 7 --pc-c4.<--pc-c4.< 6, - 1.5.14-5 Chimney Height/"B"Vent/Direct Vent Location lie Te--A,..0 R 4(L" •- dFresh Air Intake tv.hl {5L U--- (61 �‘ -- es( 3 inch Plumbing Vent through roof minimum 6 inches / Roof Complete/Exterior Finish Complete , %;� £P C to S ,;o 6 Platform at all exterior doors V Guards at stairs, decks,patios more than 30 inches above grade V Guard at stairwell at 34 inches or more ''''V-?t ow.PC6' RR t S Guard at deck,porches 36 inches or more / if Handrail Termination at Newell Post or Wall Y _- Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers NT Grade away from foundation 6 inches with 10 feet / ()Gay-,_pce-Td Rd,K_ &R A i7& 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches yr Bathroom/Kitchen watertight �/ Safety glazing/Window in stairwells safety glazing 1 Interior Smoke Detectors: Every level: Every Bedroom: ..f Outside every bedroom area: �` -Inter Connected: Battery backup: / Carbon Monoxide Detector t/! Attic access 30 inches x 22 inches x 30 inches(height)in accessible area j/ Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.fl. vents //// Bathroom Fans,if no window Plumbing fixtures VLOi IR` Foundation insulation (a`i,,,`pL&-l'6, Iio5l L Floor truss,draft stopping finished basement 1,000 sq. ft. i Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site ilij *ivy/ Oil Furnace shut-off at entrance to furnace area V Furnace/Hot Water Heater operating �j Low water shut-off boiler 1/ Relief Valve(s)installed/Heat Trap/Water Temp 110 ✓, Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches yir Garage Floor Pitched �/ Garage fireproofing/Y4 hour fire door/door closer if Duct work Sealed proper! __ZL4 Gas Logs in Sealed or Gla s Enc} sure 'd-0 6k'e-Pe• j-/,v'44- , Final Electrical g 2 /f'7 c( ,/� Final Survey Plot Plan [[[ .�Jc6p rpV ok- 52,/ev& ' As Built Septic System/Sewer DepttIInspection Sticker z/ Site Plan /Variance required /;-----;\ ` Flood Plain Certification,if reOred I _ / Okay to issue C/C or C/O Tempor y/Permanent I n 1)A1 L:\Building&Codes Forms\Buitd' g&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc • COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No. , ."/J5. Cert. N2 3787 Cut-in Card No Owner �t, )..WA? Location 5 ,r cAv242f7z7_. J2 Installation Consisting ofcy r1-A ,� � - IAk u&S,a. Installed By VIAvj ,,,,5A,,0 Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if its rules are violated,the Company shall have the right to revoke this certificate. Date ^ , r ....0 2 INSPECTOR„Qi ...... . . .. Member N.F.P.A.,I.A.E.I. Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 l �2(61 Arrive: L<<6am/pm _) : am/pm Date Inspection request received: 7 Inspector's Initials: e'�(�� NAME: G ' C PERMIT#: 06 - 16S LOCATION: S ( y(Aci,, RAAi)i) DATE: _5Lp-4,, TYPE OF STRUCTURE: Comments Yes. No N/A „ �i5 r c(<Building Number/Address visible from road "D�a•c ed � Chimney Height/'B”Vent/Direct Vent Location �/ TG-........p R Ai c..:5 •- �!� Fresh Air Intake t/// itAAW {5 - u-. 61A4-. - deA 3 inch Plumbing Vent through roof minimum 6 inches ,/ /;� Roof Complete/Exterior Finish Complete / I '' e-ta..4t �jb A 6 Platform at all exterior doors ✓ Guards at stairs,decks,patios more than 30 inches above grade V �./ jcio,.....,-r,_ 5 ,6&v l,s Guard at stairwell at 34 inches or moreRq e� Guard at deck,porches 36 inches or more / Handrail Termination at Newell Post or Wall Y ..--vp Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers /V Grade away from foundation 6 inches with 10 feet Sed:.,._p &TT Rd,K- &mA iC- 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches itsf- Bathroom/Kitchen watertight ✓✓ Safety glazing/Window in stairwells safety glazing ii Interior Smoke Detectors: Every level: Every Bedroom: / Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector // Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Y Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window 4 Plumbing fixtures 1/ �y tirp Foundation insulation I/ d.c`w..pt&rU {i'l 1)L Floor truss,draft stopping fmished basement 1,000 sq.ft. ✓ Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site j Oil Furnace shut-off at entrance to furnace area V Furnace/Hot Water Heater operating �j Low water shut-off boiler ,J Relief Valve(s)installed/Heat Trap/Water Temp 110 ✓, Enclosed Stairs Sheetrock Underside minimum'/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched f/ Garage fireproofing/3/a hour fire door/door closer s/ Duct work Sealed properl >f _1(; Gas Logs in Sealed or Gla s Enc sure �17 Kttec/C. I-/�2/9� o+ Final Electrical ' ” ri ( fj � / Final Survey Plot Plan ` 1/ Ad.c;-C;y r/n144_, 'Sti,euC-y As Built Septic System/Sewer Dept.Inspection Sticker VSite Plan /Variance required , , Flood Plain Certification,if ret ired Okay to issue C/C or C/O Tempo :, /Permanent] O Dpei L:\Building&Codes Forms\Bui .' g&Codes\Inspection Forms\Residential Final Inspection Form_revised 100405.doc Town of Queensbury Fire Marshal 742 Bay Road W3 Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Wood Burning Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# V 1 C Schedule Inspection(1 13i 16Time 1`JLC ,. pm anytime Inspector lin �� �� Name . htA� Addresso Rough In Final Appliance Manufacturer \jr..71 y� �^-1 Model# W (� 12- Masonry %Masonry Chimney •-)C Factory Built Chimney Flue Size Double Wall Triple Wall Insulated__,__ Yes No N/A Comments FIoor Protection Clearances to Combustibles (all sides) Safety Strip Installation (fireplaces only) Firestop(s) Vertical Chase L� Wall Penetration P' Chimney Clearances to Combustibles tic(f Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air Hearth Extension Mantel (height above f/p opening) Fireplace Doors / Screen (required) White—Building Dept. Yellow—Customer Pink—Fire Marshal Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive:/ am/p,ml e Depart: am/pm Date Inspection request received: Inspector's Initials: / --_ NAME: 6, 4/1/r PERMIT#: `‘' /6 LOCATION: q, ,,QBE _ DATE: ANEW. TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road C/ /y /� Chimney Height/"B"Vent/Direct Vent Location /6t/� /C✓ � (� , Fresh Air Intake ` 3 inch Plumbing Vent through roof minimum 6 inches �J<�/�L'D A% Roof Complete/Exterior Finish Complete Platform at all exterior doors MaO Guards at stairs,decks,patios more than 30 inches above grade / c., Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more o —' "" Handrail Termination at Newell Post or Wall �C�q-' 6"- 164 - Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers / ly �'C�/la4 �0 ,/� _ Grade away from foundation 6 inches with 10 feet �/ �()1 /��(/5 /��/� I• 6 inch clearance to sill plate 1 Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches 1(,,{6, rtsc.t.Ott)/n)(.. 11---6141k.Cj Bathroom/Kitchen watertight /����I> re) F3-=- "wc/ �C''� Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: eo —4/0;ir15 Ce' 1 Outside every bedroom area: ���/� Inter Connected: Battery backup: tj L1N 47 60(1 ye 5 Carbon Monoxide Detector (� Attic access 30 inches x 22 inches x 30 inches(height)in accessible area C)/e00611{ 6/01)(-% — ©K Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents / Bathroom Fans, if no window to(/-- ' Plumbing fixtures7 Foundation insulation ec 6,04-(Ike' 'r 0.F,„14,_._ -5,4/&(/ Floor truss,draft stopping nnished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical 7- ' Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required ' Flood Plain Certification, if required Okay to issue C/C or C/01 Temporary/Permanent} 7 L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection 3 Office No. (518)761-8256Arrive: ' "Jam/pm ,Depart: am/pm Date Inspection request received: _ Inspector's Initials: ,Sqi —_ NAME: LOCATION: ` DATE: #: D� 0 / T �Jlji TYPE OF STRUCTURE: / Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards t stairs, decks,patios more than 30 inches above grade Guar at stairwell at 34 inches or more G rd at deck,jorches 36 inches or more andrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq. ft. vents ithroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq. ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s) installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure ----- Final Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arriveq�''f am/pm Deepart: am/pm Date Inspection request received: — Inspectors Initials: 1' NAME: 64 /-Pr— PERMIT#: /� LOCATION: DATE: -2.�/ 2Z/d TYPE OF STRUCTURE: [[ Comments Yes No N/A Building Number/Address visible from road <G C h . Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs, decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @n,stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq. ft. vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq. ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area /l Furnace/Hot Water Heater operating , Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 C, Enclosed Stairs Sheetrock Underside minimum''Y2"Gypsum 1) 0 Basement stairs closed rise>4 inches ` i71 Garage Floor Pitched fitO C V Garage fireproofing/'/a hour fire door/door closer J Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc 1eviceo( Cini P" Ia er.it Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: PLAN NO. 2942-05 Report Date:04/02/07 Data filename: C:1Program Files\REScheck\REScheck12942-05 GRANT-5 REARDEN ROAD,QUEENSBURY.rck Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 17% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 5 REARDEN ROAD RALPH&DEBBIE GRANT&PATRICIA HARRY WILLIAMS QUEENSBURY,NY 12804 WARNER WILLIAMS&WILLIAMS DESIGNERS INC. 509 GLEN STREET GLENS FALLS,NY 12801 Compliance:Passes Maximum UA:658 Your Home UA:526-->20.1%Better Than Code(UA) Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or Door Perimeter U-Factor Ceiling 1: Flat Ceiling or Scissor Truss: 637 38.0 0.0 19 Ceiling 2:Cathedral Ceiling(no attic): 1535 38.0 0.0 41 Wall 1:Wood Frame, 16"o.c.: 1487 19.0 0.0 67 Window 1:Wood Frame:Double Pane with Low-E: 220 0.340 75 Door 1:Solid: 21 0.130 3 Door 2:Solid: 21 0.130 3 Door 3:Glass: 21 0.330 7 Door 4:Glass: 41 0.330 14 Door 5:Glass: 41 0.330 14 Wall 2:Wood Frame, 16"o.c.: 2157 19.0 0.0 113 Window 2:Wood Frame:Double Pane with Low-E: 282 0.340 96 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 341 19.0 0.0 16 Floor 2:All-Wood Joist/Truss:Over Unconditioned Space: 582 30.0 0.0 19 Crawl 1:Solid Concrete or Masonry: 585 19.0 0.0 39 Boiler 1:Gas-Fired Steam:87 AFUE The proposed •uildi g represented in this document is consistent with the building plans,specifications,and other calculations submitted wit t is •ermit application.The proposed systems have been designed to meet the New York State Energy Conservation •ns ction 4 o•e •• . -ments.When a Registered Design Professional has stamped and signed this page,they are attesting that t.the •1t of i•he k ow•dge,belief,and professional jud ment,such plans specifications are in compliance with this Code. / , ► 1 OiltiOW - OliktlIM,s (sic. s 4-11-o . '.• r►-signe Company Nam Date PLAN NO.2942-05 Page 1 of 4 REScheckctioSoftware Version 3.7Checklist.3 Inspen Date: 04/02/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: D Ceiling 2:Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.130 Comments: ❑ Door 2:Solid,U-factor:0.130 Comments: ❑ Door 3:Glass,U-factor:0.330 Comments: ❑ Door 4:Glass,U-factor:0.330 Comments: ❑ Door 5:Glass,U-factor:0.330 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: ❑ Floor 2:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Crawl Space Walls: ❑ Crawl 1:Solid Concrete or Masonry,7.0'ht/6.0'bgl4.5'insul,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: U Boiler 1:Gas-Fired Steam:87 AFUE or higher PLAN NO.2942-05 Page 2 of 4 Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on retum ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: LI Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. PLAN NO.2942-05 Page 3 of 4 Table 1:Minimum insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Insulation Thickness In Inches by Pipe Sizes Fluid Temp. Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) PLAN NO.2942-05 Page 4 of 4 D(e Permit Number RFScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code RES check Sofware Version 3.6 Release 2 Data filename: C:\Program Files\REScheck\REScheck\2942-05 GRANT-5 REARDEN ROAD, QUEENSBURY.rck PROJECT TITLE: PLAN NO. 2942-05 COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW /WALL RATIO: 0.14 DATE: 01/10/06 RECEIVED DATE OF PLANS: JANUARY 10, 2006 MAR 0 9?13J6 PROJECT DESCRIPTION: TOWN RALPH& DEBBIE GRANT & PATRICIA WARNER BU1LD1NG r,;p CODE 5 REARDEN ROAD QUEENSBURY, NEW YORK 12804 DESIGNER/CONTRACTOR: WILLIAMS & WILLIAMS DESIGNERS INC. 509 GLEN STREET GLENS FALLS, NEW YORK 12801 COMPLIANCE: Passes Maximum UA= 659 Your Home UA= 503 23.7%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor 1A Ceiling 1: Flat Ceiling or Scissor Truss 637 38.0 0.0 19 Ceiling 2: Cathedral Ceiling (no attic) 1535 38.0 0.0 41 Wall 1: Wood Frame, 16" o.c. 1487 19.0 0.0 72 Window 1: Wood Frame:Double Pane with Low-E 178 0.340 61 Door 1: Solid 21 0.130 3 Door 2: Solid 21 0.130 3 Door 3: Glass 21 0.330 7 Door 4: Glass 41 0.330 14 Wall 2: Wood Frame, 16" o.c. 2157 19.0 0.0 113 Window 2: Wood Frame:Double Pane with Low-E 240 0.340 82 Door 5: Glass 41 0.330 14 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 341 19.0 0.0 16 Floor 2: All-Wood Joist/Truss:Over Unconditioned Space 582 30.0 0.0 19 Crawl 1: Solid Concrete or Masonry 585 19.0 0.0 39 Wall height: 7.0' Depth below grade: 6.0' Insulation depth: 4.5' Boiler 1: Gas-Fired Steam, 87 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped d signed this p.:ethey are attesting that to the best of his/her knowledge, belief and professional judgment, uc plans or sp= .:.-ons are in compliance with this Code. Builder/Designer ;'r - �/i/j _A , , Date /—1 D–C69 REScheck Inspection Checklist New York State Energy Conservation Construction Code RES check Software Version 3.6 Release 2 DATE: 01/10/06 PROJECT TITLE: PLAN NO. 2942-05 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling(no attic), R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Wood Frame:Double Pane with Low-E, U-factor. 0.340 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 2. Window 2: Wood Frame:Double Pane with Low-E, U-factor. 0.340 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-tactor. 0.130 Comments: [ ] 2. Door 2: Solid, U-factor. 0.130 Comments: [ ] 3. Door 3: Glass, U-factor. 0.330 Comments: [ ] 4. Door 4: Glass, U-tactor. 0.330 Comments: [ ] 5. Door 5: Glass, U-factor 0.330 I Comments: -- -- - --- - - --- - -_ ___-- — Floors: [ ] 1. Floor l: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: [ ] 2. Floor 2: All-Wood Joist/Truss:Over Unconditioned Space, R-30.0 cavity insulation Comments: • • Crawl Space Walls: [ ] 1. Crawl 1: Solid Concrete or Masonry, 7.0' ht/6.0' bg/4.5' insul, R-19.0 cavity insulation Comments: Applies to walls ofunventilated crawl spaces. Heating and Cooling Equipment: [ ] 1. Boiler 1: Gas-Fired Steam, 87 AFUE or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufteturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fibric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The I-NAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] j Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions ofthe Building Code of New York State, the Residential Code of New York State or the New York Ciry Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part ofa circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for fzed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) TABLE 2 REQUIRED SEPARATION DISTANCES FROM WASTEWATER SYSTEM COMPONENTS wa40u Nus ,m. Le. o..ep. - l3�uantim la 1p p-tw In. W ICV IV- labe lee aa' la F lbfI lfl to be w n F Ia l4' Y.,^I,I no"hl Im n a }y r nIn los F ,a F eu" a 1 mI.I Iw'lal Sa n la' F Ccmxus • A. M' ia' la' lY Iw w' sa n F 11.1 wmnaw v.w, b' W' Ye la' le. NOTE: 1 1 W nen sews'. l,ealmen( aralem, are IOCalea in CCa,aa q,avel .1 .,,ad. and In he '•neral pall 0f tl41al. I. a well, the <I•fesl part •I lne naa,ment aralem anall be al leas, 20] I••, ,war ".. In. w.H. Ibl Mean hlpn wid r m.,x. (<1 Fu, all aralem,1-1.1n' m• Plafe-1 •1 fillmelena. aewnn•n dICIP .a mam e.a ed • In. I.. •f "b". •nee Ill. (it.. 11 Anr'ama, ,.rule. nna una.r p,eaaow Ile, 10Jid wala, aupplr mam. Muvnald a.,vlu rn., w.11 IC n.m oea."Id ae. lme) '.a'am <m.a -flin len I• •1 an, .,lbe n.ld: i..p.9. pn o, a.,, a', C6, man be manll.d mmaa a N„e, ,;,mala, wal.r maie I. p bC., n. "n"'. water mpPlr. Im ld , e I. able waur ao m IaF gnv'^ala.enbe .0 . Pressor t .p ei. an a. n.1 rvl<e I wa well1..i noufenob same. ill.) w. nq a ..a, h.11 bO1 alalled li. on.lull ,e ,-,,tare wafer ... GmOed,.n 8. M. a.we, W bam w f a d- I I r d W.,IbLlmmm aa.wa, s.<Toe fi..111.ant, R aaStandard.1 wl,a wo,4a man b•mlowed paaect.d d - 1-d 9 a 1 ,v. IO The mnmum a. par ata ea 1 b l an E d IH,, pyblk wale, supply well ,Foul, baP] hal D b 1 0 a absorption I 'I'li } I '. aCaled at Vmc10feetff-m mmu” ea r a r ,elcl mount be Iool la a foal 2W feet <ommu y Iro p bl' l•r rypP r w.II3. I' Re<ommenaetl aepa,anpn a'slan<ef LOCANON GROUND SURFACE STAKE � LOCATION STAKE MANHOLECONERI V 112.1 INSTALLATION OF DISPOSAL FIELDS 1. CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH ALL NYSDOH AND INFILTRATOR PROPRIETARY STANDARDS. 2. NO HEAVY EQUIPMENT SHALL BE ALLOWED WITHIN THE LIMITS OF THE DISPOSAL FIELD AFTER INSTALLATION. HAS BEGUN. 3. AFTER EXCAVATION TO THE REQUIRED DEPTH IS COMPLETED, THE FLOOR OF EACH RUN SHOULD BE RAKED TO ACHIEVE AN EVEN SURFACE AND TO LOOSEN ANY SMEARED AREAS. 4, ALL DISPOSAL FIELD AREAS SHALL BE GRADED TO SHED RAINFALL AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS AWAY FROM THE DISPOSAL FIELD. 5, REMOVE LEAVES, ROOTS, PLANTS, AND ORGANIC DEBRIS FROM THE DISPOSAL FIELD AREA. ( MINIMUM DISPOSAL FIELD REQUIREMENTS V NVERTOFINLETTABOVE # of Equalizer 24 runs I ° INVERTOF OVRET ET g LIQUID LEVEL Q4 D 0 t CAULKED JOINT a WALLTIICKNESSFOR 4a PULSES IN PLACE O CONCRETE } B SANITARY TEE �b D 1 `MAYBINLETE FILE 44 4 MAY BE USED INSTEAD USED `L d OF INLET SANITARY TEE a p BY MIN-GY MPX :!, d LIQUID DEPTH INSTALLATION OF DISPOSAL FIELDS 1. CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH ALL NYSDOH AND INFILTRATOR PROPRIETARY STANDARDS. 2. NO HEAVY EQUIPMENT SHALL BE ALLOWED WITHIN THE LIMITS OF THE DISPOSAL FIELD AFTER INSTALLATION. HAS BEGUN. 3. AFTER EXCAVATION TO THE REQUIRED DEPTH IS COMPLETED, THE FLOOR OF EACH RUN SHOULD BE RAKED TO ACHIEVE AN EVEN SURFACE AND TO LOOSEN ANY SMEARED AREAS. 4, ALL DISPOSAL FIELD AREAS SHALL BE GRADED TO SHED RAINFALL AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS AWAY FROM THE DISPOSAL FIELD. 5, REMOVE LEAVES, ROOTS, PLANTS, AND ORGANIC DEBRIS FROM THE DISPOSAL FIELD AREA. ( MINIMUM DISPOSAL FIELD REQUIREMENTS #BR Design Design Flow Rate (GPD) # of Equalizer 24 runs I Length of ea. Equalizer 24 run (Feet) _ Total Length (Feet) Design Basis (Min./Inch) g SANITARYTEE Q4 0 t WMINIMUM a WALLTIICKNESSFOR 4a MR,' SANITARY DISPOSAL SYSTEM House to septic tank: 4" PVC SCH 40 pipe, tightjoinis, min. slope 1/4" perfoot (2%). Septic tank to d -box: 4" PVC SDR 35 tight joints, min. slope 1/8" per foot (I %). - D -box to Equalizer 24 units: 4" PVC SDR 35 tight joints, min. slope 1/8" per foot(1%). 4� L- CAULKED JOINT 1a 12' B= 4-MIN.FORLD a 40- AND IB' MIN FOR LD 240' �c r MR,' SANITARY DISPOSAL SYSTEM House to septic tank: 4" PVC SCH 40 pipe, tightjoinis, min. slope 1/4" perfoot (2%). Septic tank to d -box: 4" PVC SDR 35 tight joints, min. slope 1/8" per foot (I %). - D -box to Equalizer 24 units: 4" PVC SDR 35 tight joints, min. slope 1/8" per foot(1%). 4� L- CAULKED JOINT 1a 12' B= 4-MIN.FORLD a 40- AND IB' MIN FOR LD 240' av g SANITARYTEE Q4 0 t WMINIMUM a WALLTIICKNESSFOR 4a PULSES IN PLACE p CONCRETE ob SEGTIONVIEW - - A. MIN. FOR LD 40 -AND Ib' MIR FOR LW 4V 12' B= 4-MIN.FORLD a 40- AND IB' MIN FOR LD 240' LD. LIQUID DEPTH ASPHALTIC4° �b `L INLET :!, FIND O OUTLET OCT .... 'ea .oP PVNWEW' TOOO•galTfowtoWo�3'bedrooms NOTE T3GQgolrforAbedrolo s- ellvg /%JO cJ4/7�=/n{ Ane,vm,m cl0'ol Neal an tlwpae9ravW.wS'Wweanea pra0l.yh Ya'1.V!-rhv0/R rlrvA, AFor hot tub/spa or garbage grinder,, SEPTIC TANK DETAIL add 250gallo s.—cO�N</o / 4, P , 17 r`- ;g eL fJavc 12 -MAX. /— REMOVABLE COVER INLET f2* FLE INVERT MIN. ELEVATION O O1 OUTLE f2 -MIN. NOTES: 1. PIPE JOINTS TO BE SEALED WITH ASPHALTIC MATERIAL OR EQUIVALENT. 2.INVERT ELEVATIONS OF ALL OUTLET PIPES MUST BE EQUAL USE OF SPEED LEVELING DEVICES IS RECOMMENDED, 3. THE SLOPE OF OUTLET PIPES BETWEEN THE DISTRIBUTION BOX AND DISTRIBUTOR LATERALS SHOULD BE AT LEAST i/32' PER FOOT. 4. BAFFLE REQUIRED FOR SIPHON OR AUTOMATIC DOSING OR IF INLET PIPE SLOPE EXCEEDS 112' PER FOOT. � n . pN A = < l 2' MIN. F I `MAIC L416ur &,4,,J GENERAL NOTES I. See NYSDOH's "Appendix 75-A, Wastewater Treatment Standards - Individual Household Systems" & "Individual Residential Wastewater TreatmentSystems-Design Ha ndbook" for additional design requirements. 2. This map is for septic system design purposes only. SOILS INFORMATION /l'k /7�/i�l' /f fr 9/111 X"; B- Sz^ > Y �-- {//ii /l i -♦. - G E - - o 'tel?ccX cA �j'O NOTE: DO NOT INSTALL IN 'NET SOIL INSTALL PARALLEL TO CONTOURS t� INSTALL AS SHALLOWAS POSSIBLE WHICH MEETS" nVOOIVEiNdTEO &t,I [,MUM DEPTHS:KF-ITH R. MANZ, '_P- IN e. 14 Norland Court / O� THE EQUALIZER 24 DETAIL TOVIIII UI i 'FURY aya opring3, NY r2ee6 BUILDING AHD CODE Final Survey Inspection Dept. of Community Development • _ Town of Queensbury 742 Bay Road Queensbury,NY 12804 ' • Date received: 2 ' 7-1 " II. t NAME: ant.Ul, _t_. LOCATION: f di it .-C t,C PERMIT#: 06 ---,A5------ Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of d Community Development. . Upon review thy survey ha .e 7 Crai: : ► , , oning Administrator Notes: r11111 n r • / r Ip .U - I ' . i 111 Ebb 2 2 2008 Ill TOWN OF QUEENSBURY L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc ii III MAP REFERENCE .MAP OF LANDS OF JAME5 M. RYAN GOMPR151NG LOT5 19-21 22-23, 11 24-25 AND 2G ON A MAP OF THE REARDON PROPERTY �) BYL LESLIE W. COULTER DATED, OCTOBER 25, 1949 Ill { LAST REVI50o OGOTBER 13. 1978 rr II' I I .I MR � ;11 ♦oma Y�� L p DRIVE F '•C(!f 0 \ is DECK AREA 48,997.33 sq. ft. HOU'5E 1.12 acres ' WELL . ED 0 z 0 O N i � k 30 � PECK Q k9 F� m 0 7 S w �yg2 pip LEGEND MRO= MAGNETIC REACTION IPFO= IRON PIPE FOUND °D.,= UTILITY POLE /--' i€ LANDS N/F OF PF 3"•.j �g'�'�� �. /) • j -. 000 BARBER rya CDC> D E C E 0\V IE fO,N;"j �-)F QUE'ENSBURY g BUeLDING &CODES tAND Date+ FEBRUARY 23, 2006 'UNAUn MILD AllFRAPgi ON ADDIMCN TO A SURVEY 1 '� MRP SEEN' A LICENSED LAND 9.RVEYCRS EEK IS A Map of a Survey made for Scate 1'=30' W 'D M>N NN EC DN 7209 EDD DIMSCN 4 DF ME ' NEW YAK STA IE EDUCATQV LAW.' I' pilY M ,pDy N& WVI ME N TINE SURVEY ®' MARKED Mllj M. O EMM E Ci ME ViUJ SURE OMS M S W nW CG190FAE0 IN BE VAIID 1AUE WITH ME' RALPH GRANT N T 1 ` FiS MICATED XEAEIX 9WIIFY MATMS \/i•.i�\, A WAS PREPARED W ACCGN B 1M , ME Laiad By ME NEW TFAK STAX SSi of u r v e ` j O g" S ° TM`'S,sa ND OV M „D„E IS ` RUN WA. 2 10/03/07 HOUSE LOCATION SHEEP 1 OF t E 1 FM EMI ME U'.Y. W N.EN D. MD ql MIS BFNAtf TO ME 1111E I LIST. WVFANMFN AND 169 Haviland Road Queensbury, New York 12804 o�iE„s°�'S' E�D"D;m ""° Town of Queensbury, Warren County, New York i 3/06/06 WELL/SEPTIC LOCATIONS GRANT G175G 518 792-8474 New York Lie. No. 50135 DING. NO. 06012 � ) N0. DATE DESCRIPTION -- 7- 1 i I'