Loading...
CC-000491-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 OL Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000491-2016 Date Issued: Tuesday, September 20, 2016 This is to certify that work requested to be done as shown by Permit Number CC-000491-2016 has been completed. Tax Map Number: 303.15-1-4 Location: 281 DIX AVE Owner: HZ Electric Supply Applicant: HZ Electric Supply This structure may be occupied as a: Commercial Alterations 875 s.f. By Order of Town Board TOWN OF QUEENSSBBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY _ 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 •ys ' — Community Development-Building&.Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000491-2016 Tax Map No: 303.15-1-4 Permission is hereby granted to: Rozell Industries Inc. For property located at: 281 DIX AVE In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvpe of Construction Owner Name: HZ Electric Supply Business Office-Alteration $0.00 Owner Address: 281 DIX AVE Total Value $0.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Rozell Industries Inc. 129 Park RD Queensbury,NY 12804 Plans&Specifications Commercial Alterations 875 s.f. $175.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,August 10,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queen�ueensb b before the ex atio date.) Dated at the Town of 10,2016 C J VvvVVV SIGNED BY: ---�� for the Town of Queensbury. Director of Building&Code Enforcement a.- •via i- v a a-v v a ---- �r n a ­x a.vs i 1/1111:6 UJG%-,YILIY Late: Ve Permit No. Cc.. b- Tax Map IDPermit Fee }'}j�E) Zone JA(e lIistoric? _Yes yN Rec Fee Ir}vv i u—, 8QZ . Subdivision Nance Lot# Site Plan# T Subdivision 4 Project Location 2$1 n)L Nr TOWN BO.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Address Phone/Email Applicant Address Phone/Email l �G _ OZ Contractor Address I ll ? ter---- Phone/Email GJ` Contact Person for Building &Codes Compliance: y�p,�,�„ Phone TYPE OF CONSTRUCTION 1/Check all that apply New Addition Alteration I'floor sf 2'floor sf Total sf Height Single Family Two-Family Multi-Family (#of units AL 27 2016 Townhouse Business Office �( 3 �/lL 4- Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business t„ 1 Proposed use of building or addition Source of Heat(circle one) G Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances&Chimneys Are there structures not shown on plot plan? OK Are there easements on the property? Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? Yes No c. Will the grade be changed as a result of construction Yes No d. Public water or Private well(circle one) Publi Private e. Sewer or Private Septic System(circle one) Sewer Private Value of all work to be performed(labor or materials) Is DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the,permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINTNAME: c►, �-- SIGNATURE: DATE: !,. _e 2016 For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski 'r Ethan Peter Hall 134 Dix Avenue �JL Glens Falls NY 12801 Voice 518 741-0268 Fax 518 741-0274 Email ephall@nycap.rr.com Transmittal Uig o 9 ��I To: John O'Brien —Town of Queensbury—Cade Enforcement From: Ethan Hall Date: 9 August, 2016 Re: HZ Electric—Wall Section Attached please find two (2) revised plans showing the requested wall section information. If there are any additional questions please let us know. FILE CQP`� 11RHA-FSlacadl1-IZ Efectriffransmittal-9 Aug 2016.doc FIRE MARSHAL'S OFFICE TOWn of Queensbury 742 Bay Road, Queensbury, NY 12804 " Hattie of Natitral Beauty ... A Good Place to Live " PLAN REVIEW F��� caPY HZ Electric Supply 281 Dix Ave C©-000491-2016 8/01/2016 The following comments are based on review of the submitted site plan: 1) Locks I latches shall comply with chapter 10 of the 2010 Fire Code of NYS. 2) Verify operation of exit / emergency lights; plan not provided so additional may be required. 3) Verify storage / ceiling heights. 4) Verify Fire Extinguisher locations. 7t� Deputy Fire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fire Marshal 's Office - Phone: 518-763-8206 - Fax. 518-745-4437 flretnarslutl@gtteensbitny.net ■ 1lrrcrtv.queetishuni.net FIDE WRSHAL"S OFFICE TozOrz of Qieensbunj 742 Bay Road, Queensbury, NY 12804 " Horne of Natural Beauty ... A Good Place to Live " PLAN REVIEW HZ Electric Supply FILE COPY 281 Dix Ave CO-000491-2016 8/01/2016 The following comments are based on review of the submitted site plan: 1) Locks / Iatches shall comply with chapter 10 of the 2010 Fire Code of NYS. 2) Verify operation of exit / emergency lights; plan not provided so additional may be required. 3) Verify storage 1 ceiling heights. 4) Verify Fire Extinguisher locations. Ail, 7 >� Deputy Fire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fi r e M a r s It a I 's Off i c e - P It o n e: 518-761-8206 - F a x: 518-745-4437 fzrerrurrslzal@gueensbitni.net - z0zvzv, ueeiesbunl.net cn a a _ s DEMOLITION NOTES REMOVE EXISTING CMU BLOCK a FOR NEW OVERHEAD DOORo _®--_---_ INDICATES EXISTING CONSTRUCTION TO BE REMOVED-CONTRACTOR SHALL REMOVE EXISTING WINDOW PROVIDE SUPPORT OF ALL STRUCTURAL , COMPONENTS PRIOR TO DEMOLITION Q) 0 1. REMOVE ALL EXISTING FINISHES THAT CONFLICT _ WITH FINISHES INDICATED ON THE FINISH PLANS. I PREPARE SURFACES AS REQUIRED FOR NEW I ; fl- MATERIALS. 0ADDED WALL SECTION 9 AUG 2016 0 I I I I EXISTING ROOF DECK/ 2. REMOVE EXISTING WALLS, PARTITIONS, DOORS,� Na. DESCRIPTION I DATE N REMOVE EXISTING DOORS I I I I REMOVE EXISTING WALLS / FRAMES, MILLWORK, FIXTURES, ETC. SHOWN ON REVISIONS THE PLAN WITH DASHED LINES. TURN ALL N & RE-USE FOR NEW II II SALVAGEABLE ITEMS OVER TO THE OWNER. SAVE OFFICE I �' I I I AND STORE ITEMS INDICATED ON DRAWINGS FOR00 I I I LATER INSTALLATION IN NEW CONSTRUCTION. II METAL SLIP JOINT3. REMOVE ALL OR ANY GENERAL, MECHANICAL, I I AND ELECTRICAL MATERIALS NOT NECESSARILY I I I I FIRE SAFING INSULATION _.i.�®._Io L__-.____ m L1 SHOWN, BUT REQUIRED TO BE REMOVED TO Z � ¢ v �- -®®� COMPLETE WORK. TURN ALL SALVAGEABLE ITEMS ? W ___ __m.___ _._.� __ 3-5/8" METAL STUD OVER TO THE OWNER. <0 Z N Q REMOVE ALL DROP CEILINGS �� o _ 4. REMOVE ALL OR ANY GENERAL ELECTRICAL a z U } AND LIGHTING IN THIS AREA " AND MECHANICAL OUTLETS AS REQUIRED. PATCH r U o 5/8 FIRE RATED GYP. BOARD PROVIDE FIRE CALKING Q _j V AT ALL JOINTS BETWEEN EXISTING WALL AS REQUIRED TO RECEIVE NEW U o a m —-- -' SLIP JOINT AND EXISITNG FINISHES IF REQUIRED. I (�' I I �'_m' —1 I ROOF DECK. 5. THE CONTRACTOR WILL BE REQUIRED TO SAW � J � o I I I I I CUT THE EXISTING CONCRETE SLAB AND REMOVEE i w it I I I I I I I WALL SECTION THE EXISTING CONCRETE SLAB FOR INSTALLATION I OF THE NEW PLUMBING PER THE MECHANICAL U 0 co � E a = o L_a..__�_ I I I I ( 1-1/2' = 1 —0' � 00 cora z = 0 DRAWINGS. FOLLOWING INSTALLATION OF _ ey N N a o F- m ______®' ___ I I I I I PLUMBING THE CONTRACTOR WILL REPAIR THE o v> �' J o H I I I I I CONCRETE SLAB TO MATCH AND BE LEVEL WITH _ } d U o z I I ; THE EXISTING CONCRETE. z c h C Q < 0 C I I I I I I 6. CONTRACTOR IS RESPONSIBLE TO VERIFY WITH (� - o u� 0 F= H I I I I I I THE BUILDING OWNER FOR ALL REMOVED DOORS ~ ¢ o L�J30" I®------------1�___®_____®.®® ®__._—__� WHETHER THEY SHOULD BE DEMO AND DISPOSED o � � � " 6 0 �-— Ao OF OR DEMO AND STORED WITH BUILDING OWNER. �'� �'�w 7. CONTRACTOR TO GRIND ADHESIVE OFF THE REMOVE EXISTING DOOR FLOOR WHERE IT EXISTS. WORK IS TO BE AS SHOWN & & RE-USE FOR NEW STEEL NOTED AND IN ACCORDANCE WITH MANUFACTURER'S FIRE RATED WALL ROOF JOIST RECOMMENDATIONS, TRADE 42'-0" GENERAL NOTES ASSOCIATION PUBLISHED r RECOMMENDATIONS AND GENERALLY ACCEPTED LOCAL ALL DOOR HARDWARE IS TO BE ADA COMPLIANT WITH LEVER HARDWARE. CONSTRUCTION INDUSTRY INTERIOR WALL & CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE WITH PRACTICES. ASTM E 84. FINISHES IN SHOWROOM AND BUSINESS OFFICE PORTION OF THE BUILDING ARE TO BE AS FOLLOWS: FINISH CLASSIFICATIONS ARE AS FOLLOWS: MATERIALS USED IN A CLASS A FINISH SHALL HAVE A FLAME SPREAD RATING OF 0-25 AND A SMOKE DEVELOPED RATING OF 0-450. MATERIALS USED IN A CLASS B FINISH SHALL HAVE A FLAME SPREAD RATING OF 26-75 AND A SMOKE DEVELOPED RATING OF 0-450. DEMOLITION PLAN MATERIALS USED IN A CLASS C FINISH SHALL HAVE A FLAME SPREAD RATING OF 76-200 AND A SMOKE DEVELOPED RATING OF 0-450. 3-5/8" METAL STUDS FLOOR FINISHES IN ALL AREAS SHALL BE NFPA 253 CLASS it OR GREATER. WITH 1/2- GYP BOARD ON EACH FACE NON-RATED WALL EXTEND TO ABOVE SUSPENDED CEILING SUSPENDED CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM ,r 5'_9" 12'-0" C635 AND ASTM C 636. NATURAL GAS TRANSMISSION AND DISTRIBUTION PIPING SHALL BE INSTALLED IN 00 ACCORDANCE WITH ASME 631.8. W8x28 W/3/8" PLATE TOWN OF QUEENSBURY BUILDING DEPARI-MENT ry NEW INSULATED OVER HEAD Based on our limited examination,compliance With our comments shall not be construed as DOOR UNIT FILE COPY indicating the plans and s pci6cltiorI3 are in � full compliance with the .Wilding Codes of New York State.sit r� RE—USE EXISTING o �+ OFFICE DOORS 00 DOOR SCHEDULE ° RE-USE EXISTING FIRE RATED DOOR _ DOOR FRAME REMARKS •�+ NUMBER TYPE MATERIAL WIDTH HEIGHT THICK. RATING HARDWARE SET TYPE MATERIAL r 7'-4" 11'-0" 8'-0" 1 A METAL 12'-0" 10'-0" - BY MFR. TRACK METAL INSULATED OVERHEAD DOOR 3 3jr 30" STEEL ROOF JOIST NEW RATED WALL 3-5/8" METAL STUDS — WITH 5/8" FIRE CODE GYP. BOARD FULL TOWN OF U E � , ' . �r 13 HEIGHT SEAL TO EXISTING ROOF STRUCTURE BUILDING D�v� W/METAL SLIP JOINT & FIRE SAPING INSULATION Reviewed By. .� _ i 42'-0" i 1 AUG U 9 291 CAD FILE NAME ACAD\HZ ELEC.\A-1 SCALE AS NOTED THE SEAL BELOW IS AN ORIGINAL SEAL DRAWN BY AND IS IN RED INK. ONLY SEALS IN RED INK NOTICE ORIGINALS �-- : SHALL BE CONSIDERED TRUE DRAWING TITLE FOAM INSULATION MUST BE TYPE "A" RED BY MINUTE SECTIONAL OVERHEAD DOOR DEMO PLAN CODE 01- Dm. THERMAL BARRIER , FLOOR PLAN FLOOR PLAN ��. 1/4's = 1'-0" NOTICE SCHEDULES / LEVER HANDLES REQUIRED ON ALL PASSAGE DOORS f .-; WHETHER INTERIOR OR NOTICE DETAILS KRAFT PAPER INSULATION EXTERIOR DOOMS :' DRAWING No. MUST BE COVERED BY NON-COM USTI LE BARRIER A- 1