2014-037 TOWN OF QUEENSBURY 742 Bay Road,Qucensbur NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140037 Date Issued: Monday, June 30, 2014 This is to certify that work requested to be done as shown by Permit Number P20140037 has been completed. Location: 41 THUNDERBIRD Rd Tax Map Number: 523400-295-013-0001-012-000-0000 Owner: JOSEPH P GROSS Applicant: JOSEPH P GROSS This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property /J owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. 1 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140037 Application Number: A20140037 Tax Map No: 523400-295-013-0001-012-000-0000 Permission is hereby granted to: JOSEPH P GROSS For property located at: 41 THUNDERBIRD Rd in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH P GROSS Deck $30,000.00 27 SILVER Cir Total Value QUEENSBURY NY 12804-0000 $30,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency TOM MAHONEY 361-0628 NY 12804-0000 Plans&Specifications 2014-037 DECK 570 sq ft $57.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,March 10,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer • of the Town of Queensbury before the expiration date.) Dated at the Tow of Q nsb i , j t .rch 10,2014 SIGNF.D BY r t for the Town of Queensbury. Director of Building&Code Enforcement Town of Queensbury Building & Codes Office Use Only n4 r t-f' '1 1 21 ACCESSORY STRUCTURE APPLICATION Received: ri-�' A permit must be obtained before beginning construction Tax Map ID: �9 i3-/- 1J, Permit No.: 03 7 For any structure other than residential principal structure(house)to include, but Permit Fee: 5 t not limited to: garage, shed, dock deck, carport, pole barn, greenhouse, etc. Site Plan No.: Refer to Informational Brochure No.3 Accessory Structures—Sheds/Fences (� Date 07 //Obi Applicant -3-65.6111 t r JL o SJ Tax MapID •�;�G '3 _ 1 - I Address 421 J'L vd 1V C 1 G 5 , I � Zoning 265 Qu 66 05 h4 R i ). j .2 =1<"-/ Phone -`ia -L'b� Owner P11 0 V-6S- Contractor/Agent `1-1a.'5' E1f<%f 1` C Address ---0-11)N'De(Z 6)R. Address S• I U6.(� I�2'c Cq,c� �Sh�`R � Iv ����f auc 6,Libo( 4' /J '( (SLS a/ Phone —001Phone Contact Person for Building&Code Compliance: /1/1 i' r1 °U6 (11 Day Phone: 3C /" 06 Building Street Address: 'J / --f v\ f.c (1Q i 1r4 Subdivision Name: Lot#: Historic Site: Yes No Estimated cost of construction: $ 1/444:3 J Q 60(..3 Are there any other accessory structures on property? If yes,please list: Type of Construction: Check all that apply Please indicate measurements as required below 1st Floor sq.ft. 2nd Floor sq.ft. Total sq.ft. Height Boathouse Boathouse with Sundeck Deck i0: 5e :i Detached Garage(#of cars_) Dock Pole Barn Porch-Open **Porch-3 season,Covered, Enclosed Shed Other Accessory Structure(s) **Considered floor area&must comply with FAR(Floor area ratio) requirements if located in the Waterfront Residential zone. Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Please include two(2)sets of the following documentation with the application fee: 1 Accessory Structure Application 2 Plot plan drawn to scale with the use of a survey map, if possible [40 scale-1 inch=40 feet] a) Indicate proposed structure,showing setback dimensions from all surveyed property lines b) Show location of all existing structures on the property c) Show location of water supply(well or water lines) d) Show location and configuration of septic disposal system or sewer line 3. Structural Drawings to include: Floor Plan;Foundation Plan;Cross Sections; Elevations 4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations with construction costs over$20,000;Any commercial construction Other Notes: 1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are necessary]. 2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial application date. 3. Additional Review-All Applications are subject to Zoning Administrator, Code Compliance, and Structural plan review CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL) Residential Building Code • New driveway requirements for structures located over 300 feet from main road; • Spray foams are allowed to be exposed in rim joist box area only, must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements; • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps; • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles; • GFI protection for all other receptacles in kitchens, bathrooms,garages, and unfinished basements; • All receptacles must be tamper resistant; • Carbon Monoxide detectors must be located within 15 feet of sleeping area; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Energy Code Requirements • Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant; • Programmable thermostats required; • Lighting must be 50%energy saving light bulbs; • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit; • Res Check inspector's checklist must be available at time of insulation inspection Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. f �} ✓I have read and agree to the above Print Name: J S Cp it P s5- Signature: SSignature: • Date: I C'1 ._ Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Queensbury Building & Code Enforcement - Resident-Again- spection Office No. (518) 761-8256 Arrive: : e. .� a � epart: .tem Date Inspection request received: Inspector's Ini a . NAME: fiU S PE' IT#: /</ LOCATION: tt v r b r rd D 'E: IQ -z?--j'-\ TYPE OF STRUCTURE: I ( k, Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor!Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan c Arc Fault Breaker Habitable Spaces/Tamper Proof Receptaclesv�_ Flex Gas Pipe Bonding ,t J 'VT' • As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/O[Temporary/Permanent] L:1Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08;Revised 12/22/10, Revised 04/13/11 DEED REFERENCE: THOMAS C. HALL, 111 TO DAVID V. CLARKE SUSAN E. CLARKE DATED: AUGUST 21, 2001 BOOK 1228 PAGE 279 W Lu f LEGEND: ( I O, IPF = IRON PIPE FOUND - - W (r O CIRF =CAPPED IRON ROD FOUND W O CIRS =CAPPED IRON ROD SET/TO BESET ® =WELL � = UTILITY POLE = CHAIN LINK FENCE 0 =IRRIGATION CONTROL BOX ¢o ©=UNDERGROUND PROPANE TANK ry II \ { 90 \ \ VERTICAL DATUM: ASSUMED ^ CONTOUR INTERVAL= 1 FOOT 44 IJI 1 r LANDS N/F OF PETER LEONBRUNO 1166/284 i O w z �tcuzs S85°00'00"E \ +� .... q 102.04' \ { . e \ S85°00 00"E a I \ 206.90' m tit ICS; ` P4 , t 7 V, I �..1 0 i OO \ / \\ S37°31'00"W a m �j • r r(, ( \\ 73.76' F o q OC cr a TIE LINE ri o� o I " o - '' so Rrjp esz, S32 56 48 E v o 0 \� n I ryrooER Race y v 174.31 ' y E" C) °pe oPCK , LANDS N/F OF AR O ERTK RNIt ' z w 4109/302 M AREA �/ /� ' A, ^ `, p BRp o 40,2171 SQ. FT. HALFVVA OOK 0.92± ACRES M t, r 5TONE , i.wP1LCONCRM ¢ 20 OM . ..._,_ . i • ., - • -. ;•,...' 'O '� s S 3'� � g'4 a p s� * F3a ry?8��RU YoyC CRU5nED STONE sa •\ " POOL NOOSE k' .� > ! i v ¢ ! r 0 ,, 165.00'... N82 ° p5 00"4V _ 1 � IPF p ; J '•.. w ' _ N __...._... . - 143. ny, , m i LANDS N/F OF TERRY & CONNIE HO WK 881/252 TAX PARCEL: 295.13-1-12 OIFF r p O i z o Z `d cy 17 0 `U p m {a�� I pERMI__ r PLor' tnN � 1 HAVE PERSCULLY MEASURED THE Ul3`1A.NCE FROM THE PROPERTY LINES TO THE x PROPOSED STRUOT')RE(S) OR SIGIJ N(.') n SIGNATURE DATE Date' September 27, 2013 I Scale T-20' ,�✓b� S®1 F� 1) 11 2014 SHEET 1 OF 1 01860 DWG. NO. 1 3 1 1 6 o. ti U O oZ U � W cr V) W Lu f LEGEND: ( I O, IPF = IRON PIPE FOUND - - W (r O CIRF =CAPPED IRON ROD FOUND W O CIRS =CAPPED IRON ROD SET/TO BESET ® =WELL � = UTILITY POLE = CHAIN LINK FENCE 0 =IRRIGATION CONTROL BOX ¢o ©=UNDERGROUND PROPANE TANK ry II \ { 90 \ \ VERTICAL DATUM: ASSUMED ^ CONTOUR INTERVAL= 1 FOOT 44 IJI 1 r LANDS N/F OF PETER LEONBRUNO 1166/284 i O w z �tcuzs S85°00'00"E \ +� .... q 102.04' \ { . e \ S85°00 00"E a I \ 206.90' m tit ICS; ` P4 , t 7 V, I �..1 0 i OO \ / \\ S37°31'00"W a m �j • r r(, ( \\ 73.76' F o q OC cr a TIE LINE ri o� o I " o - '' so Rrjp esz, S32 56 48 E v o 0 \� n I ryrooER Race y v 174.31 ' y E" C) °pe oPCK , LANDS N/F OF AR O ERTK RNIt ' z w 4109/302 M AREA �/ /� ' A, ^ `, p BRp o 40,2171 SQ. FT. HALFVVA OOK 0.92± ACRES M t, r 5TONE , i.wP1LCONCRM ¢ 20 OM . ..._,_ . i • ., - • -. ;•,...' 'O '� s S 3'� � g'4 a p s� * F3a ry?8��RU YoyC CRU5nED STONE sa •\ " POOL NOOSE k' .� > ! i v ¢ ! r 0 ,, 165.00'... N82 ° p5 00"4V _ 1 � IPF p ; J '•.. w ' _ N __...._... . - 143. ny, , m i LANDS N/F OF TERRY & CONNIE HO WK 881/252 TAX PARCEL: 295.13-1-12 OIFF r p O i z o Z `d cy 17 0 `U p m {a�� I pERMI__ r PLor' tnN � 1 HAVE PERSCULLY MEASURED THE Ul3`1A.NCE FROM THE PROPERTY LINES TO THE x PROPOSED STRUOT')RE(S) OR SIGIJ N(.') n SIGNATURE DATE Date' September 27, 2013 I Scale T-20' ,�✓b� S®1 F� 1) 11 2014 SHEET 1 OF 1 01860 DWG. NO. 1 3 1 1 6 (Sh,3) C F U HSS6x6x: Below L (Sh.2) B (Sh.3) (Sh,2) A HSS6a6x3/6 Below x N HSS6x6x3/8 Beto�v 18 go. 3 Deck 1/t HSS6x6x3/© Below x N C v N 6' Nominal Concrete Thickness E 0 N EXIST, HOUSE 0 N POSTS y !'0P RAIL THK }, CLOSURE PLATE ' ALL AROUND D'cCK a� WIOa15 TYR 1 4 TO MOM THIS DRAWING AND/OR DESIGN IS THE PROPERTY OF TRU-ARC FABRICATION, ANY USE, REPRODUCTION, ETC,, WITHOUT WRITTEN PERMISION IS STRICTLY PROHIBITED, TITHE ❑uzsicle Deck 54 24° sq, LOx49 HSS8x8x3/8 TYP. DRAWINGS FOR: S�h,1 & Sh,2