Loading...
HPSC43546 L,_ ✓IC`JNL TO SHED `PIA LR NLI:SS UNDER /1 \ N� II✓r `SOIL B�iC l _L 1ES OAD`uvP'/5, RESIFORE ROAD'S AND 06/06/13 CURB � S AND LP�RC,EIR ' OFi1PP„ 11 D _ (FINAL PLAT & NYSDOH PERMITTING) r n NO CHANGES THIS SHEET) o, IL) / r,1JJil If D ROCTC,rZ JUC,IDI__ dA,ERTIGFiT ,'0"N1S (;YP.) r. ,Ii ,A A!A C ,.- ROADWAYS, 95% NvIODIFILD FRO(IiOf 09/29/11 �,� __ „�,-•, TC:.SID SI -.Fl) & MULCH NON r ,. AI✓L.D A.rRI_�.,, A FI II SHED GRADE 08/22/11 l lj REVISED PER TIDE COMMENTS & RE -SUBMITTED FOR SUBDIVISION REVIEW VlirllfJ IvOI`vL/Y'J iJ P LT I 'ERFA,-;NEI I Pi,PPKER (NO CHANGES THIS SHEET 03/23/11 A /-14 REVISED PER TIDE COMMENTS & RE -SUBMITTED FOR SUBDIVISION REVIEW I / 10/14/10 LG REVISED PER BOARD COMMENTS TAPE c" C -EP-- --- --.-c . r IIT FOR I V ,�, .. �, �E. Vi,.,� R RLC, A 1LNUE1� DEPTH 12" (v'',IIN.) �;F;:r I I: I �� (NO CHANGES THIS SHEET - - SQ_ PIPE, ,,STACII.F-- -�-, P' C -> .._L.. SUBMITTED FOR PRELIMINARY SUBDIVISION REVIEW AND AREA VARIANCES �— ,�.,.. ✓ 1 A 1� I', IH ,� - I; �� ✓ AS SHOWN ����, �H� C SEA I ... -AN (MIN 4-e BEDi) NG ,AROUND PIPE) ®� �. _� -1T� - - MA;<.IMUM 10% PASSING 200 SI -VC) I NLET (THIS SHEET NOT SUBMITTED 04/15/09 C\ SKETCH PLAN REVIEW (PLANNING BOARD & ZONING BOARD) -3 --- III D 15„ GRAVITY SEWER TRENCH NOTES: I, SOIL PIPI (BiJll_DII`JG TC) SEPTIC 11NK) - 9'T C('VER MIN 2) Elf' UEN F PIPE IN NON- TRAFFIC Ar E/VA. : -1' MIN COVER (9 25' RUN 1'-6" PAIN CO' /ER @ 25'-40' 2' MIN COVER @ 40'4+- 3) IN TRAFFIC AREAS PROVIDE 3' OF COVER CANNOT BE ACHIEVED THEN PROVIDE A PROTECTIVL CASING 4) IN TRAFFIC AREAS IF 4' OF COVER CANNOT BE ACHIEVED THEN PROVIDE 2" RIGID FOAM INSULATION & FASTEN SECURELY TO 'PIPE. '22 WASTEWATER GRAVITY SEWER TRENCH ✓ SCALE: N.T.S. TBFAII_D LUPiIBER PVIARKER ABOVE ALL BI_iRIE) COW NS; SE( LcI- JI-L %// GRADE PROVIDE ADJU �TABI F -VL 1----�DLVICL ON ACI1 OUTS) INLET T—,> nI / it zI 4' PVC CRAVITY SEWER FOR! MILLE' 4 3CX. -�3 , .�L . ,Qx. / : 1, r O.Si N SI GPE _ __ .....i z ._ 1SIL AS RLQUI \..L) HJR SAI ISR/ L� 24 DISTRIBUTION BOX SCALE: N.T.S. NATIME BACKFNIJ_ H-IOR01,)GIHI-Y CO APA"TED i FORI PIRECAST _ II( Ir` K U LQUIVAL F -NF 12 ( Iv I'N . ; -I--- CFUSHF-D STONE FJUtiDATICN `„"TERTIGrT MANHOLE FRAME COVER; i-SYBEACUSL CASTINGS :'1502 OR EQUIVALENT, Y _ - GRADI TO urvAIN /IV!„r T1�i.or,1 �ovl-_Fz / PRECAST I�UIJCRETE 2'-J"j--RISER AS REG'D If-LU I�I PIPE, INSTALL � A, 5f I I1�I�,.,.I. 1 GI PL4J 1 , OUTLET ---- 8" NON --SHRINK GROUT INV':N. 023 SEPTIC TANK DETAIL SCALE. I T S. END PLATE WITH ,., , AiLi'.i.A- 4" PVC EQ JAI IZA110iL1 PIPE 12" MIN. OF CI_EA I SIAND 5 OR PEA GRAVEL FOUNDATION CAL,_: N.T.S. MODEL_ A1300 -4x22 -'V'1-1335 RESI'DFNTIAL "ZABEL” FILTER OR EQUIVALENT 6" (MIN.) PROVIDE EXTENDED BASE FOR ANTI -FLOTATION PURPOSES OR EQUIVALENT AS REQUIRED UNDISTURBED NATIVE SOIL 11 CK C rG 'P1 IZER 24° IN ILIRAIION ('HAVIBERS A3 EFFECTIVE - l" �=Asc DI�TRIBo1orR FROM DISTRIBUTION BOX END PLATE WITH STANDARD INVERT GEiNERAI NOTES 0-1) CONSTRUCTION OF NEA/ PIPING, TANKS, AND l_EAC :IAIG SYS -7E.4 STALL BE IN CONFORMANCE WITr, T -IE NYS DEPT Or HEAITU SJASTE'�VA ER STANDARDS, AND DETAILS/ SPECS ON THESE DCCU"'IENT CONFLICTS S'HAL' BE BROUGHT HD ENGINEERS ATIINTION 'PRIOk TO COXSTIFIJCTION WASTEWATER SYSTEM USE: U-1) NEW VASTEV"A ER DISPOSAL SY 'EM IS DILS'GNED FOR DOI,IESTIC SANITARY WASTE ONLY AT A GENERATION RATE CIF- NO ti1ORE THAN 1 0 GAL ONS PEN -JAY P_. H_JROOM- LO'Ai F_CW N!�ATh FIXTUR-S (LE 1 G GAL/FLUSH TOILETS, ?--_4 GALLON PER `.. NU'E FF,J LTS AND SHO cn I_AD�, _TC.) `'�US� BE INS ALLED THROUv OUT THE RES IDENC\FACILITY. DRAINAGE FROM FLOOR DRAMS, FOOTING DRAMS, EAVE TROOCHS, AND B✓ICK4JASH NAT --P FROM SWIMMING POOLS, WHIRLPOOLS, JACUZZIS, WA- R SOFTF ERS AND 4IAFER TREATMENT SYSTEM FAUST B'. DISPOSED OF OTHERWISE AT THE DIRECTION OF FHE OWNER. SPECIFICATIONS: TANKS / STRUCTU<ES: T-1) PRECAST STRUCTURES SHALL BE AS SUPPLIED BY FORT MIi..FR CO NC., OR rQUiVALENT. R ERcNCES TO PEACE DUTY REFER IG -CRU _RCO.'E�IrI C FOR 11-20 LO DIN' F--2) THE LQGAlIOGS OF ALL D dED STRUCTIJ tL i THAI 3C CUCvI✓1CNTED BY INS A 'ATION G` , fit MAN MARKER(S) OVER CUV t(S), ADD MEA SIURENIENT TIES" 10 PERMANENT STRUCTURES SII0,,',N ON THE 'RECORD DR ,NINGS' (SEE GENERAL LI7 ) T--3) ALL TANKS SLI b LLaI SEASONALLY J. _ Y HIGH CR JNL I!rLz EcJF101N� SHALL HE w�r"H z D �Cr�� S13 L_ FI 0T �IIvN USII'., n�,LY DJI f TANKS vJ/ b F/, I. ADcD N'EGhAL 3hSES, L)r2 �Y a\v ATfERN\FVr Iv_ riJD APPROVED Br ENGINEER. T -4) TANKS\IRUC IU REFS SQA Es= SEAMLESS CONS IRIJ LION OF ` A1_t WNV WA ER'P i� OINTS (ASI.q L1227). V!✓+'.I. PENETRATIONS CHALL BE S _EV _';SI FF'F TO BE `SEALED 10 UiF A I- `NIT NON S KINK GRO,✓T, AND THE PIPE SEALED TO TI -I- SLEEVE �NlfH A _R;IGH1 REP: ENI RL -BER S_��L. �TANKS TO 6�BSIED TO DrLIJMENI WATER TIGHTNESS FSY METHOD APPROVED ByNG! EFP "-NG!NEER TO `'IITNCSS) I-5) I_ANKS/5T'RUCI' RES INSTALLED IN TRAI"I ANI -I'S SI-1ALL BE EXTRA HFAVY COINSiRUCI,GIJ DESIGNED FOR(H-20) U>HFEL LOADING. T-6) CONTRACTOR J `1STA_- TANKS/ APUCTURES TO (RFLATIvE) ELEVATIONS SHOWN; DOCJ RENT ELEVATIONS OF EXISTING FEATURES PRIOR TO START OF CONSTRUCTION. F-/; FOR EEPNc T NKS PL 1R Ti IN SERIES THE ZA.'BEL" I'_TEk SHALL BE LOCAL J ON I OJ LET OF HE DOr fISiRE✓A IANK ONLY. FRAVE AND COVER TO 3E PROVIDE: JV ? "ZABR" FILIFE3 AND P rtl',.NEv A 1,ARKERS OVER ALL OTHER TANK OPE", TNG S UNLESS OTHERWISE D F"TED BY OWNER. PIPING SPECIFICATIONS: P-1) ALL GRAVITY 'DIER SHS, -L BE PVC SD:IR 35, ASTIJ D3034; INSTAL_ IFI .ACCORDANCE V,I ASTM D2321. ALL GRAVID'( SETTER SHALL BE LEAKAGE TSTE.D BY A MF_THCD APPROVED BY ENGINEER. r,LL RAJ SEv;A,,F GRAVITY SLVJERS ARE TO BE P�SIALL E -J AT 2% ;L11NIMUN' SLOPE RTD ,ALL EF�LUENi �RA✓�IY PIPING S 10 BE INS`ALLED Al 17 MINIMUM SLOPE. LEACHING SYSTEM: L-1) LEACH MELD/3E7 SHALL 3E (INSTALL .. IN ACCORD ^' Viffll A FM F481 UNLESS OFHER%VISE DIRECTED HEREON. L--2) INSTALL LEACHING CHA✓IB'R UNITS PER VANUFACLJR RS RFCOW/--Iv'DATIONS UNLESS 0 HERIAPSE D RETED hLI,EQIN. L-3) CONTRACTOR TO VERIFY CONSISFNr S01 CONDITIONS IN AREA OF IFA(,HIVG AR.-, PRIOR TG CONSTRUCTION; ENGINEER AND/OR O /NE'R TO BF NOTIFIED IMMEDIATELY OF INr_C,NSISIENCIFS. L-4) IN NO CASE SnALL WILL ED EQUIPMENT, EXI_rT PLOWS 'laRE REQUIRED, BE ALIOA1D DIRECTLY ON INE NATIVE SCIS WITHIN 71FE LIAI"HING AREA FO.ITPP,,NT. TRACKED EQUIPMENT SIIAL.i_ 37 USED FOR INSTALLATION, AND HLRE FILL 14AIERAI IS REQJiRED, 11 SHALL BE PULPED AT THE EDGE OF `HE LEA :TNG AREA AND P 1SED IN PI ACE AHEAD Or T EIIUIP�b1E'NT. TRACKED E �' .-IIT SrA_L BL✓.R DIRECTLY ON L 0.1INIM'�M OF ILL MATERIAL AND NOT O'NI NATIVE SOIL. L-5) CONTRACTOR I) +NSTA!L 1_EACHINS SYSTEM TO (R LiV"VE) ELEVATIONS SHOWN; JOCUMC`1 ELEVATIONS OF EXISTING FEAilJRES PRIOR TO START OF CONSTRUCTION. No 'TRUCTI If SSUE-1 D FOR CO k,,/ Ao1q "DOCUMENTS PROVIDED IN SU PPOIAf OP TI ITS DESIGN NVIY BE QSED ONLY FOR THE USE SPEC IPIED R7'I HE "ISSUE/REVISION" BLOCK BELOW. THEY MAY NOT BE USED FOR ANY OTHER PURPOSE, NOR INCORPORA I'ED IN ANY SUBSEQUENT DESIGN WORT:, WITI LOUT TI IE WRI'1"FEN CONS EN'I'OF JARS. ET'F ENGI NE P RE, PLLC. ONLY DOCUMENTS LABELS AS "ISSUED FOR CO EST RUCFION I MAY BE USED FOR SAME. USER SHALL HOLO) JARRE'Pf ENGINEERS, PLLC IIARMLESS AND DEFEND JARRET"f ENGINEERS, PLLC FROM ANY UNAUTHORIZED USE." 03/24/14 /1 \ ISSUED FOR PLAT FILING & CONSTRUCTION - (NO CHANGES THIS SHEET) 06/06/13 _ (FINAL PLAT & NYSDOH PERMITTING) NO CHANGES THIS SHEET) 11/15/11 v REVISED PERTIDE & RE SUBMITTED FOR SUBDIVISION REVIEW THISCOMMENTS 09/29/11 �J REVISED PER TIDE COMMENTS & RE -SUBMITTED FOR SUBDIVISION REVIEW (NO CHANGES THIS SHEET) 08/22/11 l lj REVISED PER TIDE COMMENTS & RE -SUBMITTED FOR SUBDIVISION REVIEW (NO CHANGES THIS SHEET 03/23/11 A /-14 REVISED PER TIDE COMMENTS & RE -SUBMITTED FOR SUBDIVISION REVIEW NO CHANGES THIS SHEET) 10/14/10 LG REVISED PER BOARD COMMENTS NO CHANGES THIS SHEET) 08/16/10 REVISED PER TOWN ENGINEER/STAFF COMMENTS & NEW ZONING REQUIREMENTS (NO CHANGES THIS SHEET 03/15/10/E\ SUBMITTED FOR PRELIMINARY SUBDIVISION REVIEW AND AREA VARIANCES (NEW SHEET) 10/08/09 SKETCH PLAN REVIEW (PLANNING BOARD &ZONING BOARD) (THIS SHEET NOT SUBMITTED 04/15/09 C\ SKETCH PLAN REVIEW (PLANNING BOARD & ZONING BOARD) (THIS SHEET NOT SUBMITTED) 02/13/09 !B� SUBMITTED FOR ZONING BOARD DISCUSSION (THIS SHEET NOT SUBMITTED) 11/17/08 /A, SUBMITTED FOR PLANNING BOARD DISCUSSION (THIS SHEET NOT SUBMITTED) DATE REV # ISSUED / REVISIONS H. THOMAS JARRETT P.E. # 57509 COPYRIGHT O 2014 ONLY COPIES OF THIS DRAWING WITH A BLUE SEAL SHALL BE CONSIDERED IF -E AND VALID ALTERATION OF THIS DOCUEDIKEXCEFT BY A LICENSED ENGINEER IS UNLAWFUL. WASTEWATER DETAILS & SPECS RESIDENTIAL SUBDIVISION SICARD PROPERTIES GLEN LAKE ROAD TOWN OF QUEENSBURY, NEW YORK JARRETT Engineers, _'LLE Civil & Environmental Engineering is 12 EAST WASHINGTON STREET PHONE: (518) 792-2907 GLENS FALLS, N.Y. FAX: (518) 798-1864 MARCH 2014 PRO # 07-008 SHEET: 19 OF 25 BASESHEET: 22 x 34 PLOTTED/ REVISED:03/24/14 10:00 AM